首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

An improved design for an odor emission hood was examined in the laboratory using ammonia emission from a water surface. The experimental ammonia convective mass transfer coefficients from a diluted ammonia solution were determined at velocities of 0.3 m/s to 0.8 m/s using the odor emission hood. The theoretical ammonia convective mass transfer coefficients were also predicted by boundary layer theory under laminar flow conditions. It was found that experimental data were only 10% below theoretical predictions at an air velocity of 0.3 m/s to 0.6 m/s. The maximum velocity was limited to 0.6 m/s by the geometric size, shape and aerodynamic stability of the hood. At 0.33 m/s, the smallest variation of mass transfer coefficients was measured. The odor emission rate was found to be a function of air velocity to the power 0.5 in accordance with boundary layer theory. An odor sampling system based upon the odor emission hood provides a way to quantify the potential odor emission strength in sewage treatment plants, for odor dispersion modeling and odor control.  相似文献   

2.
Abstract

In recent years, the utility industry has turned to bag-houses as an alternative technology for particulate emission control from pulverized-coal–fired power plants. One of the more significant issues is to improve poor gas distribution that causes bag failures in baghouse operation. Bag failures during operation are almost impossible to prevent, but proper flow design can help in their prevention. This study investigated vertical velocity profiles below the bags in a baghouse (the hopper region) to determine whether flow could be improved with the installation of flow distributors in the hopper region. Three types of flow distributors were used to improve flow distribution and were compared with the original baghouse without flow distributors. Velocity profiles were measured by a hot-wire anemometer at an inlet velocity of 18 m/sec. Uniformity of flow distribution was calculated by the uniformity value U for the velocity profile of each flow distributor. Experimental results showed that the velocity profile of the empty configuration (without flow distributors) was poor because the uniformity value was 2.048. The uniformity values of type 1 (flow distributor with three vertical vanes), type 2 (flow distributor with one vertical and one inclined vane), and type 3 (flow distributor with two inclined vanes) configurations were reduced to 1.051, 0.617, and 0.526, respectively. These results indicate that the flow distributors designed in this study made significant improvements in the velocity profile of a baghouse, with the type 3 configuration having the best performance.  相似文献   

3.
ABSTRACT

To obtain annual odor emission profiles from intensive swine operations, odor concentrations and emission rates were measured monthly from swine nursery, farrowing, and gestation rooms for a year. Large annual variations in odor concentrations and emissions were found in all the rooms and the impact of the seasonal factor (month) was significant (P < 0.05). Odor concentration was low in summer when ventilation rate was high but high in winter when ventilation rate was low, ranging from 362 (farrowing room in July) to 8934 (nursery room in December) olfactory unit (OU) m?3. This indicates that the air quality regarding odor was significantly better in summer than that in winter. Odor emission rate did not show obvious seasonal pattern as odor concentration did, ranging from 2 (gestation room in November) to 90 (nursery room in April) OU m?2 sec?1; this explains why the odor complaints for swine barns have occurred all year round. The annual geometric mean odor concentration and emission rate of the nursery room was significantly higher than the other rooms (P < 0.05). In order to obtain the representative annual emission rate, measurements have to be taken at least monthly, and then the geometric mean of the monthly values will represent the annual emission rate. Incorporating odor control technologies in the nursery area will be the most efficient in reducing odor emission from the farm considering its emission rate was 2 to 3 times of the other areas. The swine grower-finisher area was the major odor source contributing 53% of odor emission of the farm and should also be targeted for odor control. Relatively positive correlations between odor concentration and both H2S and CO2 concentrations (R 2 = 0.58) means that high level of these two gases might likely indicate high odor concentration in swine barns.

IMPLICATIONS The emissions of air pollutants including odors, greenhouse gases, and toxic gases have become a major environmental issue facing animal farms in the U.S.A. and Canada. To ensure the air quality in the vicinity of intensive livestock farms, air dispersion models have been used to determine setback distances between livestock facilities and neighboring residences based on certain air quality requirement on odor and gases. Due to the limited odor emission data available, none of the existing models can take account of seasonal variations of odor emissions, which may result in great uncertainties in setback distance calculations. Therefore, the obtained seasonal odor and gas emission rates by this study can be used by the government regulatory organizations and researchers in air dispersion modeling to get improved calculation of setback distances.  相似文献   

4.
ABSTRACT

Setback distance has been used as an effective tool to avoid odor nuisance from livestock operations. Many setback distances were guidelines that were determined by empirical methods that are considered to be lack of science base. Air dispersion models have been used to determine setback distances; however, these models do not consider the short-time fluctuations of odor. A livestock odor dispersion model (LODM) was developed to consider the short-time variations of odor and predict occurrence frequency for certain levels of odor. In this study, this model was used to predict the occurrence frequency for various levels of odor in the vicinity (10 km) of a swine farm. Using selected odor criteria, setback distances between the swine farm and nearby communities were defined. Results indicate that the LODM can be used as an effective tool to determine setback distances.

IMPLICATIONS One of the more important applications of odor dispersion models is to determine setback distances for major odor sources, such as intensive livestock operations, from nearby communities. This study provided a case study in determining directional setback distances from a typical swine farm using a newly developed livestock odor dispersion model (LODM). It is also the first study in using hourly odor frequency to determine setback distances.  相似文献   

5.
ABSTRACT

Long-path averaging instruments measure the average velocity or concentration of a substance or substances over an averaging path. These measurements are then often used for calculation of the average concentration and mass flow rate of the substance. The purpose of this paper is to describe some of the limitations of these instruments and to suggest ways in which these limitations can be minimized. Two limitations were examined: measuring concentration in a single dimension (e.g., ignoring the variation in concentration over the width of the sample plane), and deriving an average concentration without considering velocity effects. The resultant errors will be application-specific.

Estimates of the second source of error can be obtained from the covariance of concentration and velocity profiles over the path length. Unfortunately, suitable field data were not available, and to illustrate the method, estimates of the error were obtained for a range of possible concentration and velocity profiles. Errors of 50% or greater in the mass flow were incurred for the concentration and velocity profiles considered. This error was reduced to a negligible level by segmenting the averaging path length. It is recommended that velocity and concentration profiles be obtained for a broad range of applications to enable the importance of covariance errors to be better assessed.  相似文献   

6.
ABSTRACT

The possibility of using electronic noses (ENs) to measure odor intensity was investigated in this study. Two commercially available ENs, an Aromascan A32S with conducting polymer sensors and an Alpha M.O.S. Fox 3000 with metal oxide sensors, as well as an experimental EN made of Taguchi-type tin oxide sensors, were used in the experiments. Odor intensity measurement by sensory analysis and EN sensor response were obtained for samples of odorous compounds (n-butanol, CH3COCH3, and C2H5SH) and for binary mixtures of odorous compounds (n-butanol and CH3COCH3). Linear regression analysis and artificial neural networks (ANN) were used to establish a relationship between odor intensity and EN sensor responses.

The results suggest that large differences in sensor response to samples of equivalent odor intensity exist and that sensitivity to odorous compounds varies according to the type of sensors. A linear relationship between odor intensity and averaged sensor response was found to be appropriate for the EN based on conducting polymer sensors with a correlation coefficient (r) of 0.94 between calculated and measured odor intensity. However, the linear regression approach was shown to be inadequate for both ENs, which included metal oxide-type sensors. Very strong correlation (r = 0.99) between measured odor intensity and calculated odor intensity using the ANN developed were obtained for both commercial ENs. A weaker correlation (r = 0.84) was found for the experimental instrument, suggesting an insufficient number of sensors and/or not enough diversity in sensor responses. The results demonstrated the ability of ENs to measure odor intensity associated with simple mixtures of odorous compounds and suggest that ANN are appropriate to model the relationship between odor intensity measurement and EN sensor response.  相似文献   

7.
8.
9.
ABSTRACT

Intensity and threshold dilution ratio are two important indices for odor control of swine buildings. Although odor threshold dilution ratio is a widely used index to describe an odor, it should be related to intensity to be more useful. A method was proposed to measure both indices simultaneously by using a dynamic forced-choice olfacto-meter. Four air samples were taken from each of four swine rooms including farrowing, finisher, gestation, and nursery. A panel of eight people was used to evaluate odor intensity. Odor threshold dilution ratios were calculated according to the American Society for Testing and Materials (ASTM) Standard Practice E679-91 to be 333, 424, 25, and 221 for samples collected from farrowing, finisher, gestation, and nursery rooms, respectively. After the samples were diluted 14.7 times, the odor intensities were evaluated to be 3.79, 3.46, 0.48, and 4.0 for the above-mentioned rooms, respectively. The data collected were used to develop a mathematical model.  相似文献   

10.
Abstract

Odor intensity reveals a dose-effect relationship between inhaled odor and perceived odor sensation by the receptors, while odor concentration reflects the odor strength at the emission sources. The study reports significant improvements in experimental procedures in establishing the odor concentration-intensity (OCI) relationships using a newly developed digital olfactometer. The improvements in experimental procedures have been made to meet the requirements of both the VDI guideline 3882.1 and the European standard (EN13725). Several areas which could affect the reliability of the results have been identified in some similar studies. The latest digital olfactometer was calibrated automatically to ensure accurate and repeatable dilution ratios. Cross contamination has been eliminated through the instrument design and extensive cleaning procedures, making random presentation possible. Stringent panelist screening and continuous performance monitoring ensures consistent sensitivity of the panel. The extension of odor intensity category to temperature sensation gives a reference to assist judgments of perceived odor sensation. The Dyna-Scent calculation method has simplified odor intensity calculation and can be applied to many odor samples. A total of 38 odor samples from three alumina refinery sites and two sewage treatment plants were collected for analysis. The results have confirmed the efficiency of the olfactometer. Distinct Odor Concentrations (DOCs) were calculated for each sample using both VDI and DynaScent methods. A student t test on two major odor types confirmed that there are no significant differences between two methods. The study has shown the DOCs for refinery odor and wastewater odor are in the range of 3.8-15.4 and 4.2-15.6 odor unit (OU)/m3 respectively. The study demonstrated that the improvements are critical in achieving reliable odor intensity measurement. This can lead to the setup of quantitative odor impact criteria for different industries and sites.  相似文献   

11.
The emissions from five commonly used building products were studied in small-scale test chambers over a period of 50 days. The odor intensity was assessed by a sensory panel and the concentrations of selected volatile organic compounds (VOCs) of concern for the indoor air quality were measured. The building products were three floor coverings: PVC, floor varnish on beechwood parquet and nylon carpet on a latex foam backing; an acrylic sealant, and a waterborne wall paint on gypsum board. The impacts of the VOC concentration in the air and the air velocity over the building products on the odor intensity and on the emission rate of VOCs were studied. The emission from each building product was studied under two or three different area-specific ventilation rates, i.e. different ratios of ventilation rate of the test chamber and building product area in the test chamber. The air velocity over the building product samples was adjusted to different levels between 0.1 and 0.3 m s-1. The origin of the emitted VOCs was assessed in order to distinguish between primary and secondary emissions. The results show that it is reasonable after an initial period of up to 14 days to consider the emission rate of VOCs of primary origin from most building products as being independent of the concentration and of the air velocity. However, if the building product surface is sensitive to oxidative degradation, increased air velocity may result in increased secondary emissions. The odor intensity of the emissions from the building products only decayed modestly over time. Consequently, it is recommended to use building products which have a low impact on the perceived air quality from the moment they are applied. The odor indices (i.e. concentration divided by odor threshold) of primary VOCs decayed markedly faster than the corresponding odor intensities. This indicates that the secondary emissions rather than the primary emissions, are likely to affect the perceived air quality in the long run. Some of the building products continued to affect the perceived air quality despite the concentrations of the selected VOCs resulted in odor indices less than 0.1. Therefore, odor indices less than 0.1 as an accept criterion cannot guarantee that a building product has no impact on the perceived air quality.  相似文献   

12.
ABSTRACT

The following models of odor intensity for swine units were evaluated: the Weber-Fechner law model, the power law model, the Stevens model, and the Beidler model. Data were collected from four swine rooms (farrowing, finisher, gestation, and nursery) and odor threshold dilution ratios were measured by a panel using a dynamic forced-choice olfactometer. Odor intensity scales were determined by eight panelists using a six-point category scale method. A nonlinear parameter estimation method was used to estimate the parameters in each of the models. The widely used Weber-Fechner law did not adequately fit the data of odor intensity and threshold. Both the power law and the Beidler models described the data effectively, but the Beidler model showed the best fit of the data and was used as the model to represent the relationship between odor intensity and threshold dilution ratio for swine buildings.  相似文献   

13.
Abstract

Anaerobic lagoons are a major source of odor at concentrated animal feeding operations. Seven different kinds of artificial (geotextile and polyethylene foam) and natural (straw and redwood) permeable lagoon covers were evaluated for their potential to reduce odorous emissions generated by anaerobic waste lagoons. A novel floating sampling raft was constructed and used to simultaneously evaluate the effectiveness of lagoon covers on an operating swine waste lagoon. The air collected from the raft was evaluated for odor, total reduced sulfur (TRS) compounds, ammonia, total hydrocarbons, dimethyldisulfide, and trimethylamine. The emission rates from the lagoon were highly variable both temporally and spatially. All of the lagoon covers substantially reduced TRS emissions and odor. Geotextile fabric and a recycled foam cover exhibited the greatest reduction in total hydrocarbon emissions; natural covers were less effective. Because of consistently low emission rates of ammonia, no statistically significant reduction of ammonia emissions were observed from any of the lagoon covers.  相似文献   

14.
Abstract

The objective of this study was to obtain diurnal variation profiles of odor and gas (ammonia [NH3], hydrogen sulfide [H2S], carbon dioxide [CO2]) concentrations and emission rate (OGCER) from confined swine grower/finisher rooms under three typical weather conditions (warm, mild, and cold weather) in a year. Two grower/finisher rooms, one with a fully slatted floor and the other with partially slatted floors, were measured for 2 consecutive days under each weather condition. The results revealed that the diurnal OGCER in the room with a fully slatted floor was 9.2–39.4% higher than that with a partially slatted floor; however, no significant differences in the diurnal OGCER were found between these two rooms, except for the NH3 concentrations in August, the NH3 and H2S concentrations and emissions in October, and odor concentrations and emissions in February (p > 0.05). The OGCER variations presented different diurnal patterns as affected by time of day, season, type of floor, ventilation rate, animal growth cycles, in-house manure storage, and weather conditions. Significant diurnal fluctuations in the OGCER (except for the odor concentrations and H2S emissions) were observed in August (p < 0.05); all of the gas emissions in October and the CO2 concentrations and emissions in February also showed significant diurnal variations (p < 0.05). These significant diurnal variations indicated that the OGCER during different periods of a day should be monitored when quantifying OGCER concentrations and emissions; for example, source emission data used in air dispersion modeling to decrease the great incertitude of setback determination using randomly measured data.  相似文献   

15.
Source-separating urine from other domestic wastewaters promotes a more sustainable municipal wastewater treatment system. This study investigated the feasibility and potential issues of applying a urine source-separation system in tropical urban settings. The results showed that source-separated urine underwent rapid urea-hydrolysis (ureolysis) at temperatures between 34–40oC, stale/fresh urine ratios greater than 40%, and/or with slight fecal cross-contamination. Undiluted (or low-diluted) urine favored ureolysis; this can be monitored by measuring conductivity as a reliable and efficient indicator. The optimized parameters demonstrated that an effective urine source-separation system is achievable in tropical urban areas. On the other hand, the initial release of CO2 and NH3 led to an elevated pressure in the headspace of the collection reservoir, which then dropped to a negative value, primarily due to oxygen depletion by the microbial activity in the gradually alkalized urine. Another potential odor source during the ureolysis process was derived from the high production of volatile fatty acids (VFA), which were mainly acetic, propanoic, and butyric acids. Health concerns related to odor issues might limit the application of source separation systems in urban areas; it is therefore vital to systematically monitor and control the odor emissions from a source separation system. As such, an enhanced ureolysis process can attenuate the odor emissions.

Implications: Urine source separation is promising to improve the management of domestic wastewater in a more sustainable way. The work demonstrates the achievability of an effective urine source-separation system in tropical urban areas. The installation of urine-stabilization tanks beneath high-rise buildings lowers the risk of pipe clogging. Conductivity measurement can be utilized as a reliable process indicator for an automated system. However, urine hydrolysis raises a strong potential of odor emission (both inorganic and organic), which might limit the application of source separation systems in urban areas. An enhanced ureolysis process could shorten and attenuate the odor emissions.  相似文献   

16.
Abstract

This paper reports on research designed to investigate the capacities of different highly characterized peats to remove odorous compounds from liquid swine manure (LSM). Peat types representing a wide range of properties were tested in order to establish which chemical and physical properties might be most indicative of their capacities to remediate odors produced by LSM. Eight percent slurries (of peat/LSM) were measured for odor changes after 24 hours using odor panel and GC/MS‐Solid‐phase microextraction (GC/MS‐SPME) analysis.

The GC/MS‐SPME and odor panel results indicated that, although all peats tested in this study were found to be effective at removing odor‐causing compounds found in LSM, some peats tended to work better than others. Overall, the peats that were the most effective at removing odor‐causing compounds tended to have lower bulk densities, ash contents, fulvic acids contents, and guaiacyl lignins contents,and higher water holding capacities, hydraulic conductivities, “total other lignins”; contents, hydrogen contents, carbon contents, and total cellulose contents.

GC/MS‐SPME analysis was found to be a reasonably inexpensive and efficient way of conducting this type of research. It allows one to identify a large number of the odor‐causing compounds found in LSM, and more importantly, to detect with some precision specific differences in the amounts of these compounds between peat types.  相似文献   

17.
A computational fluid dynamics (CFD) methodology for simulating the combustion process has been validated with experimental results. Three different types of experimental setups were used to validate the CFD model. These setups include an industrial-scale flare setups and two lab-scale flames. The CFD study also involved three different fuels: C3H6/CH4/Air/N2, C2H4/O2/Ar, and CH4/Air. In the first setup, flare efficiency data from the Texas Commission on Environmental Quality (TCEQ) 2010 field tests were used to validate the CFD model. In the second setup, a McKenna burner with flat flames was simulated. Temperature and mass fractions of important species were compared with the experimental data. Finally, results of an experimental study done at Sandia National Laboratories to generate a lifted jet flame were used for the purpose of validation. The reduced 50 species mechanism, LU 1.1, the realizable k-? turbulence model, and the EDC turbulence–chemistry interaction model were used for this work. Flare efficiency, axial profiles of temperature, and mass fractions of various intermediate species obtained in the simulation were compared with experimental data and a good agreement between the profiles was clearly observed. In particular, the simulation match with the TCEQ 2010 flare tests has been significantly improved (within 5% of the data) compared to the results reported by Singh et al. in 2012. Validation of the speciated flat flame data supports the view that flares can be a primary source of formaldehyde emission.
ImplicationsValidated computational fluid dynamics (CFD) models can be a useful tool to predict destruction and removal efficiency (DRE) and combustion efficiency (CE) under steam/air assist conditions in the face of many other flare operating variables such as fuel composition, exit jet velocity, and crosswind. Augmented with rigorous combustion chemistry, CFD is also a powerful tool to predict flare emissions such as formaldehyde. In fact, this study implicates flares emissions as a primary source of formaldehyde emissions. The rigorous CFD simulations, together with available controlled flare test data, can be fitted into simple response surface models for quick engineering use.  相似文献   

18.
In recent years, the utility industry has turned to baghouses as an alternative technology for particulate emission control from pulverized-coal-fired power plants. One of the more significant issues is to improve poor gas distribution that causes bag failures in baghouse operation. Bag failures during operation are almost impossible to prevent, but proper flow design can help in their prevention. This study investigated vertical velocity profiles below the bags in a baghouse (the hopper region) to determine whether flow could be improved with the installation of flow distributors in the hopper region. Three types of flow distributors were used to improve flow distribution and were compared with the original baghouse without flow distributors. Velocity profiles were measured by a hot-wire anemometer at an inlet velocity of 18 m/sec. Uniformity of flow distribution was calculated by the uniformity value U for the velocity profile of each flow distributor. Experimental results showed that the velocity profile of the empty configuration (without flow distributors) was poor because the uniformity value was 2.048. The uniformity values of type 1 (flow distributor with three vertical vanes), type 2 (flow distributor with one vertical and one inclined vane), and type 3 (flow distributor with two inclined vanes) configurations were reduced to 1.051, 0.617, and 0.526, respectively. These results indicate that the flow distributors designed in this study made significant improvements in the velocity profile of a baghouse, with the type 3 configuration having the best performance.  相似文献   

19.
To correlate the odor strength of natural gas with its sulfur analysis, the recognition odor thresholds of 18 sulfur compounds were determined using an untrained panel of 35 peopie. For each test a series of odor concentrations graduated in increments of 100.2 was presented to the panel in random order over a range of concentrations above and below the olfactory thresholds of all panelists. Each odor was tested on at least three different days. Desired odor concentrations were produced by dynamic blending of gaseous mixtures of the odorous compounds with air. All testing was done out-of-doors during clement weather when no ambient odors were apparent. The range of olfactory response was found to be much greater for certain compounds than for others. Branching of the hydro-carbon chain increased odor strength. Certain compounds appeared to evoke anomalous responses.  相似文献   

20.
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods of at least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0 ± 1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.

Implications: Passive samplers are very attractive tools to experimentally tackle a number of air pollution problems, especially those related to odor impact. Their small size and cost permit a denser sampling design and thus a more detailed spatial characterization than other techniques. On the other hand, the large inherent variability in passive sampler measures requires an uncertainty analysis of the chemical species and analytical procedures used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号