首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The indoor/outdoor air pollution exposure continuity relationships are considered in an attempt to define the major parameters determining the relation. The widely accepted hypothesis of a homeostatic balance between indoor and outdoor pollutant levels has been disclaimed using particulate lead as an index contaminant. A serial filtration collection technique was employed and analysis was performed by atomic absorption spectrophotometry. The results of this study demonstrate the importance of considering parameters other than outdoor pollutant levels in determining indoor air quality.  相似文献   

2.
As part of a larger program to investigate indoor sources of air pollution, an indoor/outdoor sampling program was carried out for NO, NO2, and CO In four private houses which had gas stoves. The four houses chosen for study represented different surrounding land use, life styles, and house age and layout. The pollutant gases were measured essentially simultaneously at three indoor locations and one outdoor location. The results of the program showed that indoor levels of NO and NO2 are directly related to stove use in the homes tested. Furthermore, these stoves often produced more NO2 than NO. In some instances, the levels of NO2 and CO in the kitchen exceeded the air quality standards for these pollutants if such outdoor standards were to be applied to indoors and the data for the sampling periods were typical of an entire year. A diffusion experiment conducted in one of the houses showed that the half-life for NO2 was less than one-third that for either NO or CO. Oxidation of NO to NO2 (based upon comparing the half-life of NO to CO) does not appear to occur to a significant degree indoors.  相似文献   

3.
ABSTRACT

A portion of a population is assumed to be at risk, with the mortality hazard varying with atmospheric conditions including total suspended particulates (TSP). This at-risk population is not observed and the hazard function is unknown; we wish to estimate these from mortality count and atmospheric variables. Consideration of population dynamics leads to a state-space representation, allowing the Kalman Filter (KF) to be used for estimation. A harvesting effect is thus implied; high mortality is followed by lower mortality until the population is replenished by new arrivals.

The model is applied to daily data for Philadelphia, PA, 1973-1990. The estimated hazard function rises with the level of TSP and at extremes of temperature and also reflects a positive interaction between TSP and temperature. The estimated at-risk population averages about 480 and varies seasonally. We find that lags of TSP are statistically significant, but the presence of negative coefficients suggests their role may be partially statistical rather than biological. In the population dynamics framework, the natural metric for health damage from air pollution is its impact on life expectancy. The range of hazard rates over the sample period is 0.07 to 0.085, corresponding to life expectancies of 14.3 and 11.8 days, respectively.  相似文献   

4.
Abstract

Despite the widespread application of photochemical air quality models (AQMs) in U.S. state implementation planning (SIP) for attainment of the ambient ozone standard, documentation for the reliability of projections has remained highly subjective. An “idealized” evaluation framework is proposed that provides a means for assessing reliability. Applied to 18 cases of regulatory modeling in the early 1990s in North America, a comparative review of these applications is reported. The intercomparisons suggest that more than two thirds of these AQM applications suffered from having inadequate air quality and meteorological databases. Emissions representations often were unreliable; uncertainties were too high. More than two thirds of the performance evaluation efforts were judged to be substandard compared with idealized goals. Meteorological conditions chosen according regulatory guidelines were limited to one or two cases and tended to be similar, thus limiting the extent to which public policy makers could be confident that the emission controls adopted would yield attainment for a broad range of adverse atmospheric conditions. More than half of the studies reviewed did not give sufficient attention to addressing the potential for compensating errors. Corroborative analyses were conducted in only one of the 18 studies reviewed. Insufficient attention was given to the estimation of model and/or input database errors, uncertainties, or variability in all of the cases examined. However, recent SIP and policy‐related regional modeling provides evidence of substantial improvements in the underlying science and available modeling systems used for regulatory decision making. Nevertheless, the availability of suitable databases to support increasingly sophisticated modeling continues to be a concern for many locations. Thus, AQM results may still be subject to significant uncertainties. The evaluative process used here provides a framework for modelers and public policy makers to assess the adequacy of contemporary and future modeling work.  相似文献   

5.
Four roadway intersection air pollution models were compared to experimental data and evaluated. The models included the recently developed Texas Intersection Model (TEXIN), The Intersection Midblock Model (IMM), the program MICRO and the Indirect Source Guidelines. Data obtained by Texas A&M University at two intersections in Texas and by CALTRANS at an intersection in California were used for the evaluation. The TEXIN Model performed best in all comparisons to the data. The IMM was almost as accurate as TEXIN but required an order of magnitude more input information and computer time. MICRO and the Indirect Source Guidelines performed poorly.  相似文献   

6.
室内空气污染与控制   总被引:8,自引:0,他引:8  
论述了造成室内空气污染的主要原因,分析了室内空气污染的特点及其危害,并结合房屋建筑过程以及人们日常生活的各个方面,提出了预防及控制室内空气污染的具体方法。  相似文献   

7.
ABSTRACT

The air quality in five Finnish ice arenas with different volumes, ventilation systems, and resurfacer power sources (propane, gasoline, electric) was monitored during a usual training evening and a standardized, simulated ice hockey game. The measurements included continuous recording of carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO2) concentrations, and sampling and analysis of volatile organic compounds (VOCs). Emissions from the ice resurfacers with combustion engines caused indoor air quality problems in all ice arenas. The highest 1-hour average CO and NO2 concentrations ranged from 20 to 33 mg/m3 (17 to 29 ppm) and 270 to 7440 µg/m3 (0.14 to 3.96 ppm), respectively. The 3-hour total VOC concentrations ranged from 150 to 1200 µg/m3. The highest CO and VOC levels were measured in the arena in which a gasoline-fueled resurfacer was used. The highest NO2 levels were measured in small ice arenas with propane-fueled ice resurfacers and insufficient ventilation.

In these arenas, the indoor NO2 levels were about 100 times the levels measured in ambient outdoor air, and the highest 1-hour concentrations were about 20 times the national and World Health Organization (WHO) health-based air quality guidelines. The air quality was fully acceptable only in the arena with an electric resurfacer. The present study showed that the air quality problems of indoor ice arenas may vary with the fuel type of resurfacer and the volume and ventilation of arena building. It also confirmed that there are severe air quality problems in Finnish ice arenas similar to those previously described in North America.  相似文献   

8.
Abstract

Personal 48-hr exposures of 15 randomly selected participants as well as microenvironment concentrations in each participant’s residence and workplace were measured for 16 carbonyl compounds during summer–fall 1997 as a part of the Air Pollution Exposure Distributions within Adult Urban Populations in Europe (EXPOLIS) study in Helsinki, Finland. When formaldehyde and acetaldehyde were excluded, geometric mean ambient air concentrations outside each participant’s residence were less than 1 ppb for all target compounds. Geometric mean residential indoor concentrations of carbonyls were systematically higher than geometric mean personal exposures and indoor workplace concentrations. Additionally, residential indoor/outdoor ratios indicated substantial indoor sources for most target compounds. Carbonyls in residential indoor air correlated significantly, suggesting similar mechanisms of entry into indoor environments. Overall, this study demonstrated the important role of non-traffic-related emissions in the personal exposures of participants in Helsinki and that comprehensive apportionment of population risk to air toxics should include exposure concentrations derived from product emissions and chemical formation in indoor air.  相似文献   

9.
Abstract

A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes ~1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 107 yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octachlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Qf) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Qf/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases ≤90%.  相似文献   

10.
We studied the indoor penetration of ambient air malodorous sulfur compounds released by pulp mills. The indoor and outdoor concentrations were simultaneously measured with automatic SO2 analyzers. The filtering effect of three different materials connected to a gaseous filter unit was tested during six study periods. The tested materials were Sorbixofil® based on gypsum impregnated by KMnO4 Purafil® based on Al2O3, both absorbing sulfur compounds by oxidation, and carbonized tissue. The periods lasted from 14 to 88 days. The results indicated that malodorous sulfur air pollutants penetrated indoors effectively, but after some delay because the dilution was slow. In a comparison of different filter materials, Purafil® was the most effective, producing low indoor concentrations. The study concludes that people living near pulp mills are exposed to substantial amounts of malodorous air pollutants, both indoors and outdoors. This exposure can be reduced by using gaseous sulfur sensitive filter materials connected to a controlled ventilation system.  相似文献   

11.
Urea-formaldehyde resin bonded partlcleboard, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present In almost every office, home and public building. If large quantities of these products are used In poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make It possible to predict the performance of UF-bonded pressed wood materials If use conditions and environmental parameters are known. Recent modifications In adhesive and board manufacturing parameters have made It possible to reduce formaldehyde emission significantly, and UF-bonded wood products are now capable of meeting indoor air quality standard levels of 0.1 ppm under almost all customary loading conditions.  相似文献   

12.
13.
ABSTRACT

A low-flow rate, sharp cut point inertial impaction sampler was developed in 1986 that has been widely used in PM exposure studies in the United States and several other countries. Although sold commercially as the MS&T Area Sampler, this sampler is widely referred to as the Harvard Impactor, since the initial use was at the Harvard School of Public Health. Impactor nozzles for this sampler have been designed and characterized for flows of 4,10, 20, and 23 L/min and cut points of 1, 2, 5, and 10 |im. An improved method for determining the actual collecting efficiency curve was developed and used for the recent impactor calibrations reported here. It consists of placing a multiplet reduction impactor inline just downstream of the vibrating orifice aerosol generator to remove the multiplets, thus allowing only the singlet particle s to penetrate through to the impactor being calibrated.

This paper documents the techniques and results of recent nozzle calibrations for this sampler and compares it with other size-selective inertial impactors. In general, the impactors were found to have sharp cutoff characteristics. Particle interstage losses for all of the impactors were very low, with the exception of the 10-|im cut size 20 L/ min impactor, which had greater losses due to the higher flow rate. All of the cut nozzle laboratory calibrations compare favorably to the U.S. Environmental Protection Agency (EPA) WINS-96 fine particle mass (PM2 5) impactor calibration data.  相似文献   

14.
Ozone concentrations were measured both inside and outside the Sainsbury Centre for Visual Arts, near a small city in rural eastern England, during a three-week period in summer. The inside concentration was typically 70 ± 10% of the outside concentration during the period of expected maximum outside levels. During the period of observation the maximum outside ozone levels ranged up to 60 ppb, although there have been periods at this location where outside ozone levels have been well in excess of 120 ppb. The relatively high indoor/outdoor ozone ratio is a function of the Centre’s design, its internal geometry, and its ventilation system. Conventional art galleries and museums experience much lower indoor ozone exposure. The measured indoor ozone levels imply deleterious effects on the gallery exhibits and an enhanced ozone exposure may have to be considered in the design of modern galleries and museums.  相似文献   

15.
Simultaneous measurements were made of the concentrations of NO, NO2, and CO inside and outside of a building. The building is located in the Los Angeles area, which is heavily polluted by photochemical smog, and the experiments were conducted at a time of the year when the pollutants in question tend to be high. The results shows that there is a direct relationship between the inside and outside concentrations, and that the phase lag between the concentrations depends principally on the ratio of the building volume to the ventilation rate. Although the outside concentrations of the pollutants in question did not follow the same pattern every day, peak concentrations seemed to be related to “rush-hour” traffic. By reducing ventilation rates during these periods, it may be possible to reduce the concentration peaks inside of the building. The building involved in the current study was not located in the immediate vicinity of heavy traffic, and the indoor concentrations of NO, NO2, and CO did not appear to be very severe when compared to those defined by present air quality standards. Finally, the results support the belief that NO and O3 do not co-exist indoors except in very small quantities.  相似文献   

16.
Evaluation of Indoor air pollution problems requires an understanding of the relationship between sources, air movement, and outdoor air exchange. Research is underway to investigate these relationships. A three-phase program is being implemented: 1) Environmental chambers are used to provide source emission factors for specific indoor pollutants; 2) An IAQ (Indoor Air Quality) model has been developed to calculate indoor pollutant concentrations based on chamber emissions data and the air exchange and air movement within the indoor environment; and 3) An IAQ test house is used to conduct experiments to evaluate the model results. Examples are provided to show how this coordinated approach can be used to evaluate specific sources of indoor air pollution. Two sources are examined: 1) para-dichlorobenzene emissions from solid moth repellant; and 2) particle emissions from unvented kerosene heaters.

The evaluation process for both sources followed the three-phase approach discussed above. Para-dichlorobenzene emission factors were determined by small chamber testing at EPA’s Air and Energy Engineering Research Laboratory. Particle emission factors for the kerosene heaters were developed In large chambers at the J. B. Pierce Foundation Laboratory. Both sources were subsequently evaluated in EPA’s IAQ test house. The IAQ model predictions showed good agreement with the test house measurements when appropriate values were provided for source emissions, outside air exchange, in-house air movement, and deposition on “sink” surfaces.  相似文献   

17.
ABSTRACT

The time-series correlation between ambient levels, indoor levels, and personal exposure to PM2.5 was assessed in panels of elderly subjects with cardiovascular disease in Amsterdam, the Netherlands, and Helsinki, Finland. Subjects were followed for 6 months with biweekly clinical visits. Each subject's indoor and personal exposure to PM2.5 was measured biweekly, during the 24-hr period preceding the clinical visits. Outdoor PM2.5 concentrations were measured at fixed sites. The absorption coefficients of all PM2.5 filters were measured as a marker for elemental carbon (EC). Regression analyses were conducted for each subject separately, and the distribution of the individual regression and correlation coefficients was investigated. Personal, indoor, and ambient concentrations were highly correlated within subjects over time. Median Pearson's R between personal and outdoor PM2.5 was 0.79 in Amsterdam and 0.76 in Helsinki. For absorption, these values were 0.93 and 0.81 for Amsterdam and Helsinki, respectively. The findings of this study provide further support for using fixed-site measurements as a measure of exposure to PM2.5 in epidemiological time-series studies.  相似文献   

18.
室内空气污染分析及防治措施   总被引:2,自引:0,他引:2  
简述了室内空气污染的种类和特点,多角度论述了室内空气污染的防治措施。  相似文献   

19.
介绍了室内空气污染的来源及其危害,采用常见花木来监测室内的空气污染,并可用常见盆栽植物来防治室内的空气污染.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号