1.
A method for removal of CO from exhaust gas using pulsed corona discharge   总被引:2,自引:0,他引:2  
An experimental study of the oxidation of CO in exhaust gas from a motorcycle has been carried out using plasma chemical reactions in a pulsed corona discharge. In the process, some main parameters, such as the initial CO concentration, amplitude and frequency of pulses, residence time, reactor volume, and relative humidity (RH), as well as their effects on CO removal characteristics, were investigated. O3, which is beneficial to reducing CO, was produced during CO removal. When the exhaust gas was at ambient temperature, more than 80% CO removal efficiency was realized at an initial concentration of 288 ppm in a suitable range of the parameters.  相似文献   

2.
Abstract

In this study, experiments were performed with a bench-scale tube-type wet electrostatic precipitator (wESPs) to investigate its effectiveness for the removal of mass- and number-based diesel particulate matter (DPM), hydrocarbons (HCs), carbon monoxide (CO), and oxides of nitrogen (NOx) from diesel exhaust emissions. The concentration of ozone (O3) present in the exhaust that underwent a nonthermal plasma treatment process inside the wESP was also measured. A nonroad diesel generator operating at varying load conditions was used as a stationary diesel emission source. The DPM mass analysis was conducted by means of isokinetic sampling and the DPM mass concentration was determined by a gravimetric method. An electrical low-pressure impactor (ELPI) was used to quantify the DPM number concentration. The HC compounds, n-alkanes, and polycyclic aromatic hydrocarbons (PAHs) were collected on a moisture-free quartz filter together with a PUF/XAD/PUF cartridge and extracted in dichloromethane with sonication. Gas chromatography (GC)/mass spectroscopy (MS) was used to determine HC concentrations in the extracted solution. A calibrated gas combustion analyzer (Testo 350) and an O3 analyzer were used for quantifying the inlet and outlet concentrations of CO and NOx (nitric oxide [NO] + nitrogen dioxide [NO2]), and O3 in the diesel exhaust stream. The wESP was capable of removing approximately 67–86% of mass- and number-based DPM at a 100% exhaust volumetric flow rate generated from 0- to 75-kW engine loads. At 75-kW engine load, increasing gas residence time from approximately 0.1 to 0.4 sec led to a significant increase of DPM removal efficiency from approximately 67 to more than 90%. The removal of n-alkanes, 16 PAHs, and CO in the wESP ranged from 31 to 57% and 5 to 38%, respectively. The use of the wESP did not significantly affect NOx concentration in diesel exhaust. The O3 concentration in diesel exhaust was measured to be less than 1 ppm. The main mechanisms responsible for the removal of these pollutants from diesel exhaust are discussed.  相似文献   

3.
ABSTRACT

The investigation of an appropriate organic solvent removal apparatus for installation in a newly reconstructed print shop as a countermeasure for preventing the exhaust of organic solvents was conducted.

The selection of an organic solvent removal apparatus was made after bench-scale tests of the activated carbon adsorption method and the catalytic oxidation method, both of which are effective for the removal of organic solvents, were performed on the actual exhaust gas at the print shop. The results showed that both methods were efficient enough to be applied to the removal of organic solvents, but the activated carbon adsorption method had many drawbacks, such as the need for frequent replacement of activated carbon and complex maintenance. For the catalytic oxidation method, running costs are high, but there are many merits, such as that the catalysts do not have to be replaced as often and maintenance is simple. After considering these factors, a catalytic oxidation removal apparatus was installed at the new print shop. In the results of the substantiation test on the actual apparatus using mixed catalysts of platinum and manganese plus copper, the removal efficiency was 97.998.7% and the concentration of the outlet exhaust gas was about 10 ppm (the average concentration of the inlet exhaust gas was 528 ppm) at a space velocity of 30,000 hr-1 and a reaction temperature of 200 °C. The results of this study were substantiated.  相似文献   

4.
Abstract

A novel process for removal of nitrogen oxides (NOx) from flue gases with iron filings reduction following complex absorption in iron-ethylenediaminetetraacetic acid aqueous solution is proposed. The reaction mechanism involved in the process is discussed briefly. The parameters influencing the process, including the concentration of ferrous chelates, initial pH, amount of iron filings, temperature, flow rate of the flue gas, and inlet nitric oxide concentration and oxygen content of the flue gas, are researched in detail. The optimal NOx removal conditions are established. The regeneration and circular utilization of the absorption solution also is studied.  相似文献   

5.
ABSTRACT

This article presents the results of an industrial-scale study (on 400 MWe lignite fired unit) of simultaneous NOx, SO2, and HgT removal in FGD absorber with oxidant injection (NaClO2) into flue gas. It was confirmed that the injection of sodium chlorite upstream the FGD (Flue Gas Desulfurization) absorber oxidize NO to NO2, Hg0 to Hg2+, and enhancing NOx and HgT removal efficiency from exhaust gas in FGD absorber. Mercury removal efficiency grows with the rise of degree of oxidation NO to NO2 and was limited by the phenomenon of re-emission. For NOx removal the most critical parameters is slurry pH and temperature. There was no negative effect on sulfur dioxide removal efficiency caused by oxidant injection in tested FGD absorber. Based on the data provided, NOx and HgT emissions can be reduced by adjusting the FGD absorber operating parameters combined with oxidant injection.  相似文献   

6.
Abstract

An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 μm, the removal efficiency is greater than 80–90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is ~15.4 ± 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 μm.  相似文献   

7.
ABSTRACT

A colorimetxic method for the quantitative determination of CO by diffuse reflectance is described. This method is based on the reduction by CO of Mo (VI) from the indicator reagent molybdosilicic acid (H8Si[Mo2O7]6). The reduction yielded a change of color from clear yellow to dark green on white disk filter chart paper wetted with reagent indicator solution. The gaseous mixture containing CO was forced to pass through this chart paper, initiating the reaction. The intensity of the color produced, measured by diffuse reflectance, was proportional to the CO concentration present in exhaust gases in the range from 0.02 to 12% volume/volume (v/v). A 650-nm light-emitting diode was used as a light source. A two-fiber-optic system carried the light from the source to the detection system, which was composed of a photodiode, an amplification circuit, and a digital display. The method was applied with success in field measurements for automobiles in the Otto cycle. In a previous paper, this method was used for the quantitative determination of exhaust emissions from diesel-fueled vehicles.1  相似文献   

8.
根据滑动弧放电等离子体适于降解高浓度有机物废气的特性,结合活性炭吸附法,提出了吸附器的吸附浓缩和热脱附-等离子体氧化净化有机废气的方法。在活性炭吸附过程中,最初2 h内甲苯净化率达到100%,随着时间的增加净化率下降;在热脱附滑动弧放电等离子体净化过程中,甲苯降解效率最高为97.3%。将滑动弧放电等离子体反应器出口气相产物收集进行FT-IR检测,发现放电后有CO2、CO、H2O和NO2产生,并分析了甲苯的降解机理。  相似文献   

9.
In this study, polyvinyl alcohol (PVA) and titania (TiO2) Degussa P-25 were mixed to generate TiO2 nonwoven filters using electrospinning. The wires of titanium dioxide and the nonwoven binding titania nanofibers were formed using 14 kV voltage and a distance of 15 cm. A single-factor experimental method was used to investigate the effects of parameters such as initial concentration, retention time, and light source on acetone removal by nonwoven binding titania nanofibers. Furthermore, the effects of parameters such as gas pressure, particle size, initial concentration, and retention time on the removal of particulates were also assessed. The results showed that the degradation efficiency increased with decreasing initial concentrations and increasing retention time. The best operational conditions during this study for the removal of acetone using the TiO2 nonwoven filters were a retention time of 100 sec, initial acetone concentration of 250 ppm, and ultraviolet (UV) light source of 254 nm. Under those conditions, 99% acetone removal efficiency was obtained. In addition, 90% particulate matter removal efficiency was reached when the particulate size was greater than 200 nm and the reaction time was longer than 5 minutes. The prepared TiO2/nanofiber has good performance for volatile organic compounds (VOCs) and particulate removal at the same time.

Implications: In this study, polyvinyl alcohol (PVA) and titania (TiO2) Degussa P-25 were mixed to generate TiO2 nonwoven filters using electrospinning. The results showed that the optimum operating conditions for the removal of acetone using the TiO2 nonwoven filters were a retention time of 100 sec, initial acetone concentration of 250 ppm, and UV light source of 254 nm. Under those conditions, 99% acetone removal efficiency was obtained.  相似文献   


10.
Abstract

The removal system for the absorption of CO2 with amines and NH3 is an advanced air pollution control device to reduce greenhouse gas emissions. Absorption of CO2 by amines and NH3 solutions was performed in this study to derive the reaction kinetics. The absorption of CO2 as encountered in flue gases into aqueous solutions of monoethanolamine (MEA), diethanolamine (DEA), and NH3 was carried out using a stirred vessel with a plane gas-liquid interface at 50 °C. Various operating parameters were tested to determine the effect of these variables on the absorption kinetics of the reactants in both gas and liquid phases and the effect of competitions between various reactants on the mass-transfer rate.

The observed absorption rate increases with increasing gas-liquid concentration, solvent concentration, temperature, and gas flow rate, but changes with the O2 concentration and pH value. The absorption efficiency of MEA is better than that of NH3 and DEA, but the absorption capacity of NH3 is the best. The active energies of the MEA and NH3 with CO2 are 33.19 and 40.09 kJ/mol, respectively.  相似文献   

11.
Incineration flue gas contains polycyclic aromatic hydrocarbons (PAHs) and sulfur dioxide (SO2). The effects of SO2 concentration (0, 350, 750, and 1000 ppm), reaction temperature (160, 200, and 280 °C), and the type of activated carbon fibers (ACFs) on the removal of SO2 and PAHs by ACFs were examined in this study. A fluidized bed incinerator was used to simulate practical incineration flue gas. It was found that the presence of SO2 in the incineration flue gas could drastically decrease removal of PAHs because of competitive adsorption. The effect of rise in the reaction temperature from 160 to 280 °C on removal of PAHs was greater than that on SO2 removal at an SO2 concentration of 750 ppm. Among the three ACFs studied, ACF-B, with the highest microporous volume, highest O content, and the tightest structure, was the best adsorbent for removing SO2 and PAHs when these gases coexisted in the incineration flue gas.
ImplicationsSimultaneous adsorption of sulfur dioxide (SO2) and polycyclic aromatic hydrocarbons (PAHs) emitted from incineration flue gas onto activated carbon fibers (ACFs) meant to devise a new technique showed that the presence of SO2 in the incineration flue gas leads to a drastic decrease in removal of PAHs because of competitive adsorption. Reaction temperature had a greater influence on PAHs removal than on SO2 removal. ACF-B, with the highest microporous volume, highest O content, and tightest structure among the three studied ACFs, was found to be the best adsorbent for removing SO2 and PAHs.  相似文献   

12.
In this study, experiments were performed with a bench-scale tube-type wet electrostatic precipitator (wESPs) to investigate its effectiveness for the removal of mass- and number-based diesel particulate matter (DPM), hydrocarbons (HCs), carbon monoxide (CO), and oxides of nitrogen (NOx) from diesel exhaust emissions. The concentration of ozone (O3) present in the exhaust that underwent a nonthermal plasma treatment process inside the wESP was also measured. A nonroad diesel generator operating at varying load conditions was used as a stationary diesel emission source. The DPM mass analysis was conducted by means of isokinetic sampling and the DPM mass concentration was determined by a gravimetric method. An electrical low-pressure impactor (ELPI) was used to quantify the DPM number concentration. The HC compounds, n-alkanes, and polycyclic aromatic hydrocarbons (PAHs) were collected on a moisture-free quartz filter together with a PUF/XAD/PUF cartridge and extracted in dichloromethane with sonication. Gas chromatography (GC)/mass spectroscopy (MS) was used to determine HC concentrations in the extracted solution. A calibrated gas combustion analyzer (Testo 350) and an O3 analyzer were used for quantifying the inlet and outlet concentrations of CO and NOx (nitric oxide [NO] + nitrogen dioxide [NO2]), and O3 in the diesel exhaust stream. The wESP was capable of removing approximately 67-86% of mass- and number-based DPM at a 100% exhaust volumetric flow rate generated from 0- to 75-kW engine loads. At 75-kW engine load, increasing gas residence time from approximately 0.1 to 0.4 sec led to a significant increase of DPM removal efficiency from approximately 67 to more than 90%. The removal of n-alkanes, 16 PAHs, and CO in the wESP ranged from 31 to 57% and 5 to 38%, respectively. The use of the wESP did not significantly affect NOx concentration in diesel exhaust. The O3 concentration in diesel exhaust was measured to be less than 1 ppm. The main mechanisms responsible for the removal of these pollutants from diesel exhaust are discussed.  相似文献   

13.
Abstract

A semi-industrial scale test was conducted to thermally treat mixtures of spent oil and askarels at a concentration of 50,000 ppm and 100,000 ppm of polychlorinated biphenyls (PCBs) under a reductive atmosphere. In average, the dry-basis composition of the synthesis gas (syngas) obtained from the gasification process was: hydrogen 46%, CO 34%, CO2 18%, and CH4 0.8%. PCBs, polychlorinated dibenzo-p-dioxins, and polychlorinated dibenzofurans (PCDDs/PCDFs) in the gas stream were analyzed by high-resolution gas chromatography (GC)-mass spec-trometry. The coplanar PCBs congeners 77, 105, 118, 156/157, and 167 were detected in the syngas at concentrations <2 ×10?7 mg/m3 (at 298 K, 1 atm, dry basis, 7% O2). The chlorine released in the destruction of the PCBs was transformed to hydrogen chloride and separated from the gas by an alkaline wet scrubber. The concentration of PCBs in the water leaving the scrubber was below the detection limit of 0.002 mg/L, whereas the destruction and removal efficiency was >99.9999% for both tests conducted. The concentration of PCDDs/PCDFs in the syngas were 8.1 ×10?6 ng-toxic equivalent (TEQ)/m3 and 7.1 × 10?6 ng-TEQ/m3 (at 298 K, 1 atm, dry basis, 7% O2) for the tests at 50,000 ppm and 100,000 ppm PCBs, respectively. The only PCDD/F congener detected in the gas was the octachloro-dibenzo-p-dioxin, which has a toxic equivalent factor of 0.001. The results obtained for other pollutants (e.g., metals and particulate matter) meet the maximum allowed emission limits according to Mexican, U.S., and European regulations for the thermal treatment of hazardous waste (excluding CO, which is a major component of the syngas, and total hydrocarbons, which mainly represent the presence of CH4).  相似文献   

14.
Abstract

In Mexico City, the use and composition of fuels determine that carbon monoxide (CO) comes mostly from mobile sources, and sulfur dioxide (SO2) from fixed and mobile sources. By simultaneously measuring hydrocarbons (HC), CO, and SO2 in the atmosphere of Mexico City, the relative amounts coming from different sources can be estimated. Assuming that some HC are emitted proportionally to CO emissions, we can establish that [HC]1= m1? [CO], where the proportionality constant ml corresponds to the ratio of emissions factor for HC and CO in mobile sources. Similarly for fuels containing sulfur, it can be assumed that [HC]2 = m2 ? [SO2]. In this way, the total HC are [HC]total=[HC]0+ ml ? [CO]+ m2 ? [SO2], where [HC]0 corresponds mainly to other sources like solvent evaporation, gas consumption, and natural emissions. In this way, it can be estimated that in Mexico City 75% of average HC comes from mobile sources, 5% from sulfur-related sources, and 19% from natural sources and solvent evaporation. Compared with the HC/CO ratio measured in the exhaust pipe of vehicles, we estimated that 70% of HC emitted from mobile sources are evaporative losses, and only 30% come through the exhaust system.  相似文献   

15.
The photo-Fenton reaction was applied as a novel method for the removal of volatile organic compounds (VOCs) in the gas phase, and its effectiveness was experimentally examined. In conventional VOCs removal methods using a photocatalyst or ozone, VOCs are oxidized in the gas phase. Therefore, incompletely oxidized intermediates, which may have adverse effects on health, are likely to contaminate the treated air. On the other hand, in the VOCs removal method developed in this study, because the VOCs are oxidized in the liquid phase by the photo-Fenton reaction, any incompletely oxidized intermediates produced are confined to the liquid phase. As a result, the contamination of the treated air by these harmful intermediates can be prevented. Using a semi-batch process, it was found that the removal efficiency for toluene in a one-pass test (residence time of 17 s) was 61%, for an inlet toluene gas concentration of 930 ppbv, an initial iron ion concentration of 20 mg L−1, and an initial hydrogen peroxide concentration of 630 mg L−1. The removal efficiency was almost constant as long as H2O2 was present in the solution. Proton transfer reaction mass spectrometry analysis confirmed the absence of any incompletely oxidized intermediates in the treated air.  相似文献   

16.
Abstract

Dichloromethane (DCM, also known as methylene chloride [CH2Cl2]) is often present in industrial waste gas and is a valuable chemical product in the chemical industry. This study addresses the oxidation of airstreams that contain CH2Cl2 by catalytic oxidation in a tubular fixed-bed reactor over perovskite-type oxide catalysts. This work also considers how the concentration of influent CH2Cl2 (Co = 500-1000 ppm), the space velocity (GHSV = 5000-48,000 1/hr), the relative humidity (RH = 10-70%) and the concentration of oxygen (O2 = 5-21%) influence the operational stability and capacity for the removal of CH2Cl2.

The surface area of lanthanum (La)-cobalt (Co) composite catalyst was the greatest of the five perovskite-type catalysts prepared in various composites of La, strontium, and Co metal oxides. Approximately 99.5% CH2Cl2 reduction was achieved by the catalytic oxidation over La-CoO3-based perovskite catalyst at 600 °C. Furthermore, the effect of the initial concentration and reaction temperature on the removal of CH2Cl2 in the gaseous phase was also monitored. This study also provides information that a higher humidity corresponds to a lower conversion. Carbon dioxide and hydrogen chloride were the two main products of the oxidation process at a relative humidity of 70%.  相似文献   

17.
ABSTRACT

The effectiveness of a new emission control system in the ice resurfacer was tested in an exhaust gas emission laboratory, and the improvement of the air quality in a small, enclosed ice arena was demonstrated in a 4.5-month follow-up study. The emission control system consisted of a lambda sensor-controlled fuel supply and a three-way metallic catalyst that were applied to a propane-fueled resurfacer. In the laboratory tests, the engine emissions of carbon monoxide (CO), hydrocarbons (HC), and nitrogen oxides (NO ) reduced simultaneously by 91, 90, and 96%, respectively. During the air quality follow-up the median 1-hour average nitrogen dioxide (N02) concentration inside the ice arena decreased from 430 ug/m3 (230ppb) to 58 ug/m3 (31 ppb), and that of CO decreased from 4.4 mg/m3 (3.8 ppm) to 1.5 mg/m3 (1.3 ppm). The new emission control system proved to be a feasible, reliable, and effective means to improve the indoor air quality in the ice arena. However, continuous mechanical ventilation was necessary during all business hours in order to achieve and maintain a fully acceptable air quality with this technology.  相似文献   

18.
旋转填料床/柠檬酸盐法吸收-解吸SO2   总被引:1,自引:1,他引:0  
提出采用旋转填料床结合柠檬酸盐法脱除烟气中SO2的方法,考察了旋转填料床转子转速、液气比、初始柠檬酸根浓度和初始pH值等因素对脱硫效率的影响。结果表明,采用超重力法超重机转子转速为1 000 r/min、液气比为7L/m3、初始柠檬酸根浓度为1.5 mol/L、吸收液的初始pH值为5.0,脱硫效率稳定在99%左右。研究了水蒸气汽提法解吸SO2时初始柠檬酸根浓度、初始pH值、SO2浓度、富液流量和水蒸气流量对解吸效率的影响,得出了影响SO2解吸率的基本规律,并进行了分析。通过实验证明该方法在技术上是可行的,具有良好的应用前景。  相似文献   

19.
Abstract

Based on exhaust gas analyses from the combustion of five different types of gasoline in a passenger car operated on a chassis dynamometer, box model simulations of the irradiation of exhaust/NOx /air mixtures using an established chemical mechanism for a standardized photo-smog scenario were performed. The fuel matrix used covered wide fractional ranges for paraffinic, olefinic, and aromatic hydrocarbons. Two fuels also contained methyl tertiary butyl ether (MTBE). The different O3 profiles calculated for each run were compared and interpreted. The O3 levels obtained were strongly influenced by the exhaust gas concentrations of aromatic and olefinic hydro-carbons. The higher exhaust content of these compounds caused higher O3 production in the smog system investigated. The conclusion of the present study is that the composition of gasoline cannot be taken directly for the estimation of the emissions’ O3 creation potential from its combustion. Variation of the dilution in the different calculations showed evidence for an additional influence of transport effects. Accordingly, further detailed exhaust gas analyses followed by more complex modeling studies are necessary for a proper characterization of the relationship between fuel blend and gasoline combustion products.  相似文献   

20.
The concentrations of fine particles and selected gas pollutants in the flue gas entering the stack were measured under several common operation modes in an operating coal power plant producing electricity. Particle size distributions in a diameter range from 10 nm to 20 μm were measured by a scanning mobility particle sizer (SMPS), and the flue gas temperature and concentrations of CO2 and SO2 were monitored by a continuous emission monitoring system (CEMS). During the test campaign, five plant operating modes were studied: soot blowing, bypass of flue-gas desulfurization (FGD), reheat burner operating at 0% (turned off), 27%, and 42% (normal condition) of its full capacity. For wet and dry aerosols, the measured mode sizes were both around 40 nm, but remarkable differences were observed in the number concentrations (#/cm3, count per square centimeter). A prototype photoionizer enhanced electrostatic precipitator (ESP) showed improved removal efficiency of wet particles at voltages above +11.0 kV. Soot blowing and FGD bypass both increased the total particle number concentration in the flue gas. The temperature was slightly increased by the FGD bypass mode and varied significantly as the rating of reheat burner changed. The variations of CO2 and SO2 emissions showed correlations with the trend of total particle number concentration possibly due to the transitions between gas and particle phases. The results are useful in developing coal-fired power plant operation strategies to control fine particle emissions and developing amine-based CO2 capture technologies without operating and environmental concerns associated with volatile amine emissions.

Implications: The measurement of the fine particle size distributions in the exhaust gas under several common operating conditions of a coal-fired power plant revealed different response relations between aerosol number concentration and the operating condition. A photo-ionizer enhanced ESP was demonstrated to capture fine particles with higher efficiency compared to conventional ESPs, and the removal efficiency increased with the applied voltage. The characteristic information of aerosols and main gaseous pollutants in the exhaust gas is extremely important for developing and deploying CO2 scrubbers, whose amine emissions and operating effectiveness depends greatly on the upstream concentrations of fine particles, SO2, from the power plant.  相似文献   