首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A conventional impactor for a particle speciation sampler was developed and validated through laboratory and field tests. The speciation sampler consists of the following components: a PM2.5 conventional impactor that removes particles larger than 2.5 microns, an all-glass, coated honeycomb diffusion denuder, and a 47-mm filter pack. The speciation sampler can operate at two different sampling rates: 10 and 16.7 L/min. An experimental characterization of the impactor's performance was conducted. The impactor's collection efficiency was examined as a function of critical design parameters such as Reynolds number, the distance from the nozzle exit to the impaction plate, and the impaction substrate coating method. The bounce of particles larger than the cut point was successfully minimized by using a greased surface as the impaction substrate. Additionally, a series of field intercomparison experiments were conducted at both 10 and 16.7 L/min airflow. PM2.5 mass and SO4(2-) concentrations were measured and compared with the Federal Reference Method (FRM) and found to be in good agreement. Results of the laboratory chamber tests also indicated that the impactor's performance was in good agreement with the FRM.  相似文献   

2.
The replacement of the Desert Research Institute (DRI) model 2001 with model 2015 thermal/optical analyzers (TOAs) results in continuity of the long-term organic carbon (OC) and elemental carbon (EC) database, and it adds optical information with no additional carbon analysis effort. The value of multiwavelength light attenuation is that light absorption due to black carbon (BC) can be separated from that of brown carbon (BrC), with subsequent attribution to known sources such as biomass burning and secondary organic aerosols. There is evidence of filter loading effects for the 25% of all samples with the highest EC concentrations based on the ratio of light attenuation to EC. Loading corrections similar to those used for the seven-wavelength aethalometer need to be investigated. On average, nonurban Interagency Monitoring of PROtected Visual Environments (IMPROVE) samples show higher BrC fractions of short-wavelength absorption than urban Chemical Speciation Network (CSN) samples, owing to greater influence from biomass burning and aged aerosols, as well as to higher primary BC contributions from engine exhaust at urban sites. Sequential samples taken during an Everglades National Park wildfire demonstrate the evolution from flaming to smoldering combustion, with the BrC fraction increasing as smoldering begins to dominate the fire event.

Implications: The inclusion of seven wavelengths in thermal/optical carbon analysis of speciated PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) samples allows contributions from biomass burning and secondary organic aerosols to be estimated. This separation is useful for evaluating control strategy effectiveness, identifying exceptional events, and determining natural visibility conditions.  相似文献   


3.
Multi-layer perceptron (MLP) artificial neural network (ANN) models are compared with traditional multiple regression (MLR) models for daily maximum and average O3 and particulate matter (PM10 and PM2.5) forecasting. MLP particulate forecasting models show little if any improvement over MLR models and exhibit less skill than do O3 forecasting models. Meteorological variables (precipitation, wind, and temperature), persistence, and co-pollutant data are shown to be useful PM predictors. If MLP approaches are adopted for PM forecasting, training methods that improve extreme value prediction are recommended.  相似文献   

4.
关于PM2.5的综述   总被引:3,自引:0,他引:3  
综述了大气PM25的来源,样品采集分析,化学组成,病毒机理,对人类健康和大气能见度的影响,以及国内外的研究进展.  相似文献   

5.
Aeolian dust episodes (ADEs) have been an emergency disaster in the Kaoping River Valley during the rainy season (May-September), which can severely deteriorate ambient particulate air quality in the region surrounding the Kaoping River. Thus, this study aims to characterize the metallic fingerprint of Aeolian dust (AD) and investigate the effects of ADEs on ambient particulate air quality along the Kaoping River Valley. Four manual sampling sites adjacent to the riverside were selected to collect fine (PM2.5) and coarse (PM2.5–10) aerosol samples during and after the ADEs in the periods of six events. A total of 13 metallic elements were analyzed using an inductively coupled plasma-atomic emission spectrometer. With metallic elements analysis and nonparametric statistical methods of Wilcoxon rank-sum test and Kruskal-Wallis test, this study successfully derived the metallic indicators of ADEs. The mass ratios of crustal elements (Fe, Ca, or Al) to reference element (Cd) obtained during the ADEs were much higher than those obtained after the ADEs. High mass ratios of Fe/Cd, Ca/Cd, and Al/Cd in PM2.5-10 were observed on the influenced areas of ADEs. Among them, (Fe/Cd)2.5-10 was proven as the best indicator which can be applied to effectively validate the existence of ADEs and evaluate their influences on ambient air quality. Moreover, PM2.5 concentrations during the ADEs were 3-3.6 fold higher than those after the ADEs. PM2.5 should be a contributor to AD, even though the mass ratios of PM2.5/PM10 ranged from 0.05 to 0.20 during the ADEs. Our findings provide valuable information regarding the characteristics of the AD during the ADEs in the Kaoping River.

Implications: Indicators of (Fe/Cd)2.5-10 are approximately applied to observe the effects of ADEs. Local governments could realize the mechanisms of S- and NW-type aeolian dust episodes (ADEs). They can cause deterioration in different ways for the regional air quality surrounding Kaoping River Valley. Residents who have been living in the influenced areas can take precautions to prevent damage from aeolian dust. Strategies for curbing ADEs must reduce the area of bare lands by artificial measures in the long period of the sunny days during the rainy season. Future research should examine physical conditions of topsoils and other chemical composition in aeolian dust.  相似文献   


6.
Fine particles in urban atmospheres contain substantial quantities of semi-volatile material [e.g., NH4NO3 and semi-volatile organic compounds (SVOCs)] that are lost from particles during collection on a filter. Several diffusion denuder samplers have been developed for the determination of both NO3- and organic semi-volatile fine particulate components. The combination of technology used in the BOSS diffusion denuder sampler and the Harvard particle concentrator has resulted in the Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) for the 24-hr (or less) integrated collection of PM2.5, including NH4NO3 and semi-volatile organic material. Modification of the BOSS sampler allows for the weekly determination of these same species. Combination of BOSS denuder and tapered element oscillating microbalance (TEOM) monitor technology has resulted in the real-time ambient mass sampler (RAMS) for the continuous measurement of PM2.5, including the semi-volatile components. Comparison of the results obtained with the BOSS and with each of the newly developed modifications of the BOSS indicates that the modified versions can be used for the continuous, daily, or weekly monitoring of PM2.5, including semi-volatile species, as appropriate to the design of each sampler.  相似文献   

7.
The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degrees C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degrees C and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degrees C and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 microg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

8.
In this paper, we describe the development and laboratory and field evaluation of a continuous coarse (2.5-10 microm) particle mass (PM) monitor that can provide reliable measurements of the coarse mass (CM) concentrations in time intervals as short as 5-10 min. The operating principle of the monitor is based on enriching CM concentrations by a factor of approximately 25 by means of a 2.5-microm cut point round nozzle virtual impactor while maintaining fine mass (FM)--that is, the mass of PM2.5 at ambient concentrations. The aerosol mixture is subsequently drawn through a standard tapered element oscillating microbalance (TEOM), the response of which is dominated by the contributions of the CM, due to concentration enrichment. Findings from the field study ascertain that a TEOM coupled with a PM10 inlet followed by a 2.5-microm cut point round nozzle virtual impactor can be used successfully for continuous CM concentration measurements. The average concentration-enriched CM concentrations measured by the TEOM were 26-27 times higher than those measured by the time-integrated PM10 samplers [the micro-orifice uniform deposit impactor (MOUDI) and the Partisol] and were highly correlated. CM concentrations measured by the concentration-enriched TEOM were independent of the ambient FM-to-CM concentration ratio, due to the decrease in ambient coarse particle mass median diameter with an increasing FM-to-CM concentration ratio. Finally, our results illustrate one of the main problems associated with the use of real impactors to sample particles at relative humidity (RH) values less than 40%. While PM10 concentrations obtained by means of the MOUDI and Partisol were in excellent agreement, CM concentrations measured by the MOUDI were low by 20%, and FM concentrations were high by a factor of 5, together suggesting particle bounce at low RH.  相似文献   

9.
Abstract

The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods1 (Document 2.12) requires conditioning of PM2.5 filters at 20-23 °C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed ±2 °C and ±5% RH during the conditioning period. The quality assurance team at EPA Region 2’s regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements.

The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA’s Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, ±0.2 °C and ±0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 μg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

10.
Arsenic is a toxic element that affects human health and is widely distributed in the environment. In the area of study, the main Spanish and second largest European industrial ceramic cluster, the main source of arsenic aerosol is related to the impurities in some boracic minerals used in the ceramic process. Epidemiological studies on cancer occurrence in Spain points out the study region as one with the greater risk of cancer. Concentrations of particulate matter and arsenic content in PM10 and PM2.5 were measured and characterized by ICP-MS in the area of study during the years 2005–2010. Concentrations of PM10 and its arsenic content range from 27 to 46 μg/m3 and from 0.7 to 6 ng/m3 in the industrial area, respectively, and from 25 to 40 μg/m3 and from 0.7 to 2.8 ng/m3 in the urban area, respectively. Concentrations of PM2.5 and its arsenic content range from 12 to 14 μg/m3 and from 0.5 to 1.4 ng/m3 in the urban background area, respectively. Most of the arsenic content is present in the fine fraction, with ratios of PM2.5/PM10 in the range of 0.65–0.87. PM10, PM2.5, and its arsenic content show a sharp decrease in recent years associated with the economic downturn, which severely hit the production of ceramic materials in the area under study. The sharp production decrease due to the economic crisis combined with several technological improvements in recent years such as substitution of boron, which contains As impurities as raw material, have reduced the concentrations of PM10, PM2.5, and As in air to an extent that currently meets the existing European regulations.  相似文献   

11.
ABSTRACT

Mobile sources are significant contributors to ambient PM2 5, accounting for 50% or more of the total observed levels in some locations. One of the important methods for resolving the mobile source contribution is through chemical mass balance (CMB) receptor modeling. CMB requires chemically speciated source profiles with known uncertainty to ensure accurate source contribution estimates. Mobile source PM profiles are available from various sources and are generally in the form of weight fraction by chemical species. The weight fraction format is commonly used, since it is required for input into the CMB receptor model. This paper examines the similarities and differences in mobile source PM2.5 profiles that contain data for elements, ions, elemental carbon (EC) and organic carbon (OC), and in some cases speciated organics (e.g., polycyclic aromatic hydrocarbons [PAHs]), drawn from four different sources.

Notable characteristics of the mass fraction data include variability (relative contributions of elements and ions) among supposedly similar sources and a wide range of average EC:OC ratios (0.60 ± 0.53 to 1.42 ± 2.99) for light-duty gasoline vehicles (LDGVs), indicating significant EC emissions from LDGVs in some cases. For diesel vehicles, average EC:OC ratios range from 1.09 ± 2.66 to 3.54 ± 3.07. That different populations of the same class of emitters can show considerable variability suggests caution should be exercised when selecting and using profiles in source apportionment studies.  相似文献   

12.
针对目前家居环境净化PM2.5的要求,在现有空气过滤材料的基础上,探讨一种适合于家居环境移动式空气净化装置用低阻、高效和长寿命的过滤材料。采用实验研究的方法对常用玻纤滤纸以及驻极体空气过滤材料进行了过滤特性、电镜、孔径测试的对比实验研究。结果表明,当过滤风速为5 cm/s时,3种驻极体滤料对粒径≤4.5 μm的颗粒物的分级过滤效率要高于玻纤滤纸且都在90%以上,其过滤阻力在4.9~6.4 Pa之间,而高效滤纸的过滤阻力在57.8~78.6 Pa之间;在实验风速条件下,驻极体滤料对PM2.5的过滤效率和过滤阻力分别高于和低于高效玻纤滤纸;对驻极体滤料进行蒸馏水洗涤后,其对颗粒物的过滤效率下降,驻极体滤料静电效应具有不稳定特性;电镜测试发现,玻纤滤纸纤维层排布致密,纤维存在断裂现象,而驻极体滤料较为蓬松,无纤维断裂现象;孔径实验表明,驻极体滤料的平均孔径为玻纤滤纸的11.9~14.7倍,驻极体滤料具有良好的透气和容尘特性。  相似文献   

13.
Recent advances in the development of receptor-oriented source apportionment techniques (models) have provided a new approach to evaluating the performance of particulate dispersion models. Rather than limiting performance evaluations to comparisons of particulate mass, receptor model estimates of source impacts can be used to open new opportunities for in-depth analysis of dispersion model performance. Recent experiences in the joint application of receptor and dispersion models have proven valuable in developing increased confidence in source impact projections used for control strategy development. Airshed studies that have followed this approach have identified major errors in emission inventory data bases and provided technical support for modeling assumptions.

This paper focuses on the joint application of dispersion and receptor models to particulate source impact analysis and dispersion model performance and evaluation. The limitations and advantages of each form of modeling are reviewed and case studies are examined. The paper is offered to provide several new perspectives into the model evaluation process in the hope that they may prove useful to those that manage our nation’s air resources.  相似文献   

14.
The U.S. Environmental Protection Agency (EPA), state and local agencies have focused their efforts in assessing secondary fine particulate matter (aerodynamic diameter ≤2.5 µm; PM2.5) formation in prevention of significant deterioration (PSD) air dispersion modeling. The National Association of Clean Air Agencies (NACAA) developed a method to account for secondary PM2.5 formation by using sulfur dioxide (SO2) and nitrogen oxides (NOx) offset ratios. These ratios are used to estimate the secondary formation of sulfate and nitrate PM2.5. These ratios were first introduced by the EPA for nonattainment areas in the Implementation of the New Source Review (NSR) Program for Particulate Matter Less than 2.5 Micrometers (PM2.5), 73 FR 28321, to offset emission increases of direct PM2.5 emissions with reductions of PM2.5 precursors and vice versa. Some regulatory agencies such as the Minnesota Pollution Control Agency (MPCA) have developed area-specific offset ratios for SO2 and NOx based on Comprehensive Air Quality Model with Extensions (CAMx) evaluations for air dispersion modeling analyses. The current study evaluates the effect on American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) predicted concentrations from the use of EPA and MPCA developed ratios. The study assesses the effect of these ratios on an electric generating utility (EGU), taconite mine, food processing plant, and a pulp and paper mill. The inputs used for these four scenarios are based on common stack parameters and emissions based on available data. The effect of background concentrations also evaluates these scenarios by presenting results based on uniform annual PM2.5 background values. This evaluation study helps assess the viability of the offset ratio method developed by NACAA in estimating primary and secondary PM2.5 concentrations. An alternative Tier 2 approach to combine modeled and monitored concentrations is also presented.

Implications:

On January 4, 2012, the EPA committed to engage in rulemaking to evaluate updates to the Guideline on Air Quality Models (Appendix W of 40 CFR 51) and, as appropriate, incorporate new analytical techniques or models for secondary PM2.5. As a result, the National Association of Clean Air Agencies (NACAA) developed a screening method involving offset ratios to account for secondary PM2.5 formation. The use of this method is promising to evaluate total (direct and indirect) PM2.5 impacts for permitting purposes. Therefore, the evaluation of this method is important to determine its viability for widespread use.  相似文献   


15.
This study investigates the use of a small passive sampler for aerosol particles to determine particulate matter (PM)10-2.5 concentrations in outdoor air. The passive sampler collects particles by gravity, diffusion, and convective diffusion onto a glass coverslip that is then examined with an optical microscope; digital images are processed with free software and the resultant PM10-2.5 concentrations determined. Both the samplers and the analyses are relatively inexpensive. Passive samplers were collocated with Federal Reference Method (FRM) samplers in Chapel Hill, NC; Phoenix, AZ; and Birmingham, AL; for periods from 5 to 15 days. Particles consisted primarily of inorganic dusts at some sites and a mix of industrial and inorganic materials at other sites. Measured concentrations ranged from < 10 microg/m3 to approximately 40 microg/m3. Overall, PM10-2.5 concentrations measured with the passive samplers were within approximately 1 standard deviation of concentrations measured with the FRM samplers. Concentrations determined with passive samplers depend on assumptions about particle density and shape factors and may also depend somewhat on local wind speed and turbulence; accurate values for these parameters may not be known. The degree of agreement between passive and FRM concentrations measured here suggests that passive measurements may not be overly dependent on accurate knowledge of these parameters.  相似文献   

16.
17.
It will be many years before the recently deployed network of fine particulate matter with an aerodynamic diameter less than 2.5 microm (PM2.5) Federal Reference Method (FRM) samplers produces information on nonattainment areas, trends, and source impacts. However, data on PM2.5 and its major constituents have been routinely collected in California for the past 20 years. The California Air Resources Board operated as many as 20 dichotomous (dichot) samplers for PM2.5 and coarse PM (PM10-2.5). The California Acid Deposition Monitoring Program (CADMP) collected 12-h-average PM2.5 and PM10 from 1988 to 1995 at ten urban and rural sites and 24-h-average PM2.5 at five urban sites since 1995. Beginning in 1994, the Children's Health Study collected 2-week averages of PM2.5 in 12 communities in southern California using the Two-Week Sampler (TWS). Comparisons of collocated samples establish relationships between the dichot, CADMP, and TWS samplers and the 82-site network of PM2.5 FRM samplers deployed since 1999 in California. PM mass data from the different monitoring programs have modest to high correlation to FRM mass data, fairly small systematic biases and negative proportional biases ranging from 7 to 22%. If the biases are taken into account, all of the programs should be considered comparable with the FRM program. Thus, historical data can be used to develop long-term PM trends in California.  相似文献   

18.
Environmental Science and Pollution Research - Exposure to fine particulate matter can easily lead to health issues. PM2.5 concentrations are associated with various spatiotemporal factors, which...  相似文献   

19.
Time-resolved data is needed for public notification of unhealthful air quality and to develop an understanding of atmospheric chemistry, including insights important to control strategies. In this research, continuous fine particulate matter (PM2.5) mass concentrations were measured with tapered element oscillating microbalances (TEOMs) across New Jersey from July 1997 to June 1998. Data features indicating the influence of local sources and long-distance transport are examined, as well as differences between 1-hr maxima and 24-hr average concentrations that might be relevant to acute health effects. Continuous mass concentrations were not significantly different from filter-collected gravimetric mass concentrations with 95% confidence intervals during any season. Annual mean PM2.5 concentrations from July 1997 to June 1998 were 17.3, 16.4, 14.1, and 15.3 micrograms/m3 at Newark, Elizabeth, New Brunswick, and Camden, NJ, respectively. Monthly averaged 24- and 1-hr daily maximum PM2.5 concentrations suggest the existence of a high PM2.5 (May-October) and a low PM2.5 (November-April) season. PM2.5 magnitudes and temporal trends were very similar across the state during high PM2.5 events. In fact, the between-site coefficients of determination (R2) for daily PM2.5 measurements were 84-98% for June and July. Additionally, during the most pronounced PM2.5 episode, PM2.5 concentrations closely tracked the daily maximum 1-hr O3 concentrations. These observations suggest the importance of transport and atmospheric chemistry (i.e., secondary formation) to PM2.5 episodes in New Jersey. The influence of local sources was observed in diurnal concentration profiles and annual average between-site differences. Urban wintertime data illustrate that high 1-hr maximum PM2.5 concentrations can occur on low 24-hr PM2.5 days.  相似文献   

20.
使用β射线法在线监测仪连续监测了贵阳市白云区PM_(10)和PM_(2.5)浓度,分析了2014年6月1日—12月31日7个月内PM_(10)、PM_(2.5)的浓度水平、时变规律和PM_(2.5)/PM_(10)的变化情况。结果表明,监测时段内PM_(10)和PM_(2.5)的日均浓度平均值分别为76.8μg/m~3和40.0μg/m~3,均达到国家二级标准;浓度超标的天数占总观测天数的5.1%和9.3%,属污染轻微的地区。PM_(2.5)/PM_(10)在25.3%~78.8%之间周期性波动,平均值为52.1%。PM_(10)和PM_(2.5)的浓度变化具有很好的正相关性(r=0.919 8,p0.000 1);日均值在7个月中呈现明显的周期性变化,各月相对稳定,12月的PM_(10)和PM_(2.5)浓度最高且变化最为剧烈,6月最为平缓。PM_(10)和PM_(2.5)浓度小时变化总体上呈双峰型分布,最高值出现在出现在09:00—10:00和19:00—21:00前后,最低值出现在14:00—17:00之间。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号