共查询到20条相似文献,搜索用时 15 毫秒
1.
Yannick Chapuis Danilo Klvana Jitka Kirchnerova 《Journal of the Air & Waste Management Association (1995)》2013,63(7):845-854
Abstract Photocatalytic oxidation (PCO) of volatile organic compounds (VOCs) is a highly attractive alternative technology for purification and deodorization of indoor air. The main objectives of this study were to demonstrate that a common fluorescent visible light (FVL) lamp can be used to effectively remove by PCO low concentrations of VOCs from slightly contaminated air and to provide some fundamental and technical details on the process. The target VOC was n-butanol, which is a standard reference odorant. Its PCO was studied under a long residence time in a 3.7-L cylindrical reactor with commercial titanium dioxide (TiO2) as the reference photocatalyst and using mostly FVL for illumination. For comparison only, a UV (black) light lamp was used. The gas-phase products were detected and quantified online by gas chromatography (GC). The effects of reactor residence time, of inlet concentration, and of the relative light intensity on the efficiency of the process were also evaluated. At a high n-butanol concentration (0.1 vol %), butanal and propanal were identified as the intermediate products of the process; ethanal appeared when the initial concentration was <850 ppmv. This indicates that PCO leading to CO2 and H2O is relatively slow and proceeds in a stepwise manner. Although the efficiency of the process with an FVL lamp was significantly lower than when using a UV black light, complete PCO of low concentrations was achieved for 100 ppmv. In a search for a material with photoactivation extended to higher wavelengths or increased photo-activity, several samples of transition metal- or silver ion-doped (2 atomic %) TiO2 as well as SrTi1xFexO3 (x = 0.1 and 0.15) perovskites were included in the study. None of these materials was more active than pure TiO2. The results of this study open new horizons in the area of indoor air quality (IAQ) control. 相似文献
2.
Kuo-Pin Yu Grace Whei-May Lee Wei-Ming Huang Chih-Cheng Wu Chia-ling Lou Shinhao Yang 《Journal of the Air & Waste Management Association (1995)》2013,63(5):666-674
Abstract Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photo-catalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr?1, and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and form-aldehyde found in this study ranged from 0.381 to 1.01 hr?1 under different total air change rates, from 0.34 to 0.433 hr?1 under different RH, and from 0.381 to 0.433 hr?1 for different photocatalytic filters. 相似文献
3.
Michael Kosusko Carlos M. Nunez 《Journal of the Air & Waste Management Association (1995)》2013,63(2):254-259
Catalytic oxidation is an air pollution control technique in which volatile organic compounds (VOCs) and vapor-phase air toxics in an air emission stream are oxidized with the help of a catalyst Design of catalytic systems for control of point source emissions is based on stream-specific characteristics and desired control efficiency. This paper discusses the key emission stream characteristics and VOC characteristics that affect the applicability of catalytic oxidation. The application of catalytic oxidation technology to four types of air emission sources is discussed: (1) groundwater stripping operations; (2) graphic arts facilities; (3) flexographic printing plants; and (4) latex monomer production. The characteristics of each of these emissions are discussed along with the catalytic technology used to control these emissions. 相似文献
4.
有机废气吸附净化处理的新型工艺研究 总被引:2,自引:0,他引:2
简要介绍了挥发性有机废气的来源、分类及其对人体和环境的危害,以及盐城市部分企业近年来的产生和排放状况。较详细地论述了吸附净化处理技术用于废气中挥发性有机化合物的去除和回收研究工艺与特点,阐明了目前有机废气的净化处理方向。 相似文献
5.
Marek Krzymien Michael Day Kathleen Shaw Lillian Zaremba 《Journal of the Air & Waste Management Association (1995)》2013,63(7):804-813
ABSTRACT The emissions of odors and volatile organic compounds produced from a commercial composting operation have been studied using a laboratory-scale composting system. The composting activity of a typical commercial compost feed was followed by monitoring the composting temperature, as well as the respiratory rate. Using a controlled aeration system, the gaseous volatiles produced were tested for odors using the "dilution-to-threshold" method, as well as gas composition, as determined by gas chromatography-mass spectrometry. The results indicated that while there may be a reasonable correlation between the release of volatile organic compounds (VOCs) and odors, care has to be taken when trying to identify offensive odors with specific chemical species. However, the data obtained suggests that offensive odors formed during commercial composting may be due to sulfurous and nitrogenous compounds, although their concentrations in the compost gases may not be very high. The major release of VOCs occurred during the first two weeks of composting, after which the gaseous releases fell dramatically as the composting process proceeded and temperatures started to fall. 相似文献
6.
W.V. Kirstine I.E. Galbally 《Journal of the Air & Waste Management Association (1995)》2013,63(10):1299-1311
Abstract Grass, and particularly cut grass, recently has been shown to emit significant amounts of volatile organic compounds (VOCs) into the atmosphere. Some components of these emissions are highly reactive and may contribute to photochemical smog in urban areas. A simple model for estimating the VOC emissions from grass and for grass cutting that allows these processes to be included in urban/regional emissions inventories is presented here. Using previous work and recent literature values, estimates are made of these biogenic volatile organic compound (BVOC) emissions for two typical urban airsheds, those including the cities of Sydney and Melbourne in Australia. Grass and cut grass could contribute ~2% for Sydney and 3% for Melbourne of the total VOCs emitted into these urban atmospheres annually. These contributions could rise to 4 and 5%, respectively, during the weekends of the summer growing season and, thus, could contribute to weekday/weekend ozone differences. It is recommended that the emissions of BVOCs from grass and cut grass be included in urban and global emissions inventories so that more accurate predictions of smog chemistry can be determined. 相似文献
7.
C. K. Varshney Pratap Kumar Padhy 《Journal of the Air & Waste Management Association (1995)》2013,63(5):448-453
ABSTRACT Total volatile organic compounds (TVOCs) in the urban ambient environment of Delhi were monitored from November 1994 to June 1995 at 13 sites using an inexpensive and a manual-labor-intensive sample collection procedure in want of sophisticated equipment. The results of the study show appreciable levels of TVOCs in the ambient environment of Delhi. The amount of TVOCs in the ambient environment was found to vary between 3 and 42 ppmv and exhibited wide temporal and seasonal variations. On a diurnal cycle, TVOC levels mostly peaked at 9:00 a.m., which coincided with the peak traffic hour. TVOC buildup in the urban atmosphere has serious implications for air quality through the formation of highly toxic oxidants. The results of this preliminary study make out a strong case for a regular monitoring of TVOCs in the urban environment of Delhi. 相似文献
8.
Dilsad Akal Mihriban Yılmaz Civan Gürdal Tuncel Hülya Yavuz Ersan 《Environmental Forensics》2015,16(2):173-185
A total of 34 volatile organic compounds (VOCs) were measured in the indoor of laboratories, offices and classrooms of the Chemical Engineering Department of Hacettepe University in Ankara in 2 week-day passive sampling campaigns. The average concentrations ranged from 0.77 to 265 μg m?3 at the different indoor sites, with the most abundant VOC found to be toluene (119.6 μg m?3), followed by styrene (21.24 μg m?3), 2-ethyltoluene (17.11 μg m?3), n-hexane (10.21 μg m?3) and benzene (9.42 μg m?3). According to the factor analysis, the evaporation of solvents used in the laboratories was found to be the dominant source. 相似文献
9.
Jun-Hong Lin 《Journal of the Air & Waste Management Association (1995)》2013,63(8):1083-1090
Abstract The Henry’s law constant is important in the gas-liquid mass transfer process. Apparent dimensionless Henry’s law constant, or the gas-liquid partition coefficient (K’ H), for both hydrophilic (methanol, isopropyl alcohol, and acetone) and hydrophobic (toluene and p-xylene) organic compounds in deionized (DI) water, a wastewater with a maximum total dissolved organic carbon (DOC) content of 700 mg/L, and DI water mixed with a maximum activated sludge suspended solid (SS) concentration of 40,000 mg/L were measured using the single equilibrium technique at 293 K. Experimental results demonstrate that the K’ H of any of the test volatile organic compounds varied among three situations. First, the K’H of the hydrophilic compounds in mixed liquor with the maximum SS concentration was 9–21% higher than those in DI water. Second, those for toluene and p-xylene were 77% and 93% lower, respectively, in the mixed liquor with the maximum SS concentration. Third, the K’H values of all of the test compounds in the wastewater were only 10% lower than those in DI water. A model was developed to relate K’ H with wastewater DOC and the SS concentration in the activated sludge using an organic carbon-water partition coefficient and activated sludge-water partition coefficient as model parameters. The model was verified and model parameters for test compounds estimated. 相似文献
10.
Steven S. Cox Alfred T. Hodgson 《Journal of the Air & Waste Management Association (1995)》2013,63(8):1195-1201
ABSTRACT The initial solid-phase concentration of volatile organic compounds (VOCs) is a key parameter influencing the emission characteristics of many indoor materials. Solid-phase measurements are typically made using solvent extraction or thermal headspace analysis. The high temperatures and chemical solvents associated with these methods can modify the physical structure of polymeric materials and, consequently, affect mass transfer characteristics. To measure solid-phase concentrations under conditions resembling those in which the material would be installed in an indoor environment, a new technique was developed for measuring VOC concentrations in vinyl flooring (VF) and similar materials. A 0.09-m2 section of new VF was punched randomly to produce ~200 0.78-cm2 disks. The disks were milled to a powder at -140 °C to simultaneously homogenize the material and reduce the diffusion path length without loss of VOCs. VOCs were extracted from the VF particles at room temperature by fluidized-bed desorption (FBD) and by direct thermal desorption (DTD) at elevated temperatures. The VOCs in the extraction gas from FBD and DTD were collected on sorbent tubes and analyzed by gas chromatog-raphy/mass spectrometry (GC/MS). Seven VOCs emitted by VF were quantified. Concentration measurements by FBD ranged from 5.1 |ig/g VF for n-hexadecane to 130 |Jg/g VF for phenol. Concentrations measured by DTD were higher than concentrations measured by FBD. Differences between FBD and DTD results may be explained using free-volume and dual-mobility sorption theory, but further research is necessary to more completely characterize the complex nature of a diffusant in a polymer matrix. 相似文献
11.
分析了机动车尾气挥发性有机物(VOCs)的排放特征,发现尾气VOCs排放具有明显的日变化和季节变化特征。不同区域不同车型机动车尾气VOCs成分谱略有差异,轻型汽油车尾气VOCs中芳香烃和烷烃含量较高,柴油车烷烃含量较高。尾气排放受机动车保有量、行驶里程、维护保养水平、行驶速度和燃油标准、排放标准等因素影响。从优先控制汽油车、加快机动车更新、采取本地化减排措施、加强多元管理措施、提高科研水平等方面提出了针对性的减排措施。 相似文献
12.
D. Bruce Henschel Roy C. Fortmann Nancy F. Roache Xiaoyu Liu 《Journal of the Air & Waste Management Association (1995)》2013,63(5):708-717
ABSTRACT A laboratory thermal desorption apparatus was used to measure emissions from a number of nominally identical photocopier toners—manufactured to meet the specifications of one specific model copier—when these toners were heated to fuser temperature (180-200 °C). The objective was to assess how potential volatile organic compound (VOC) emissions from the toner for a given copier can vary, depending upon the production run and the supplier. Tests were performed on a series of toner (and associated raw polymer feedstock) samples obtained directly from a toner manufacturer, representing two production runs using a nonvented extrusion process, and on toner cartridges purchased from two local retailers, representing three different production lots (histories unknown). The results showed that the retailer toners consistently had up to 350% higher emissions of some major compounds (expressed as |ig of compound emit-ted/g of toner), and up to 100% lower emissions of others, relative to the manufacturer toners (p ≤ 0.01). The manufacturer toners from one production run had emissions of certain compounds, and of total VOCs, that were modestly higher (13-18%) than those from the other run (p ≤ 0.01). The emission differences between the retailer and manufacturer toners are probably due to differences 相似文献
13.
《Journal of the Air & Waste Management Association (1995)》2013,63(9):1112-1122
Abstract Photocatalytic oxidation (PCO) was investigated in a bench-scale reactor for the abatement of two airborne organic contaminants: toluene and ethanol. A mathematical model that includes the impacts of light intensity, initial contaminant concentration, catalyst thickness, and relative humidity (RH) on the degradation of organic contaminants in a photocatalytic reactor was developed to describe this process. The commercially available catalyst Degussa-PtTiO2 was selected to compare with the MTU-PtTiO2-350 catalyst, which was synthesized by the sol-gel process, platinized, and calcined at 350 °C. For toluene removal using the MTU-PtTiO2-350 catalyst, the degradation rate increased with increases in light intensity from 0.2 to 2.2 mW/cm2 and in catalyst thickness from 0.00037 to 0.00361 cm. However, further increases in light intensity and catalyst thickness had only slight effect on the toluene degradation rate. Increasing the initial concentration from 6.29 to 127.9 μg/L and the RH from 10 to 85% resulted in decreases in the toluene degradation rate. For ethanol removal using the MTU-PtTiO2- 350 catalyst, the degradation rate increased more rapidly with an increase in RH from 17 to 56%; the RH had little effect on the ethanol degradation rate while it further increased from 56% to 82%. We discuss applicability of the model to estimate the influence of process variables and to evaluate photocatalyst performance. 相似文献
14.
George M. Russwurm Robert H. Kagann Orman A. Simpson William A. McClenny William F. Herget 《Journal of the Air & Waste Management Association (1995)》2013,63(8):1062-1066
A long-path Fourier transform spectrometer was used to make measurements of volatile organic compounds in an industrial complex in New Castle, Delaware as part of the Superfund Innovative Technology Evaluation (SITE) program. These data are compared to data taken with a whole-air canister technique. To provide an effective comparison the canisters were transported along the path for a 32-min period. For each FTIR spectrum, 256 interferograms were co-added over a 4-mln period. Eight individual spectra were then co-added to obtain the comparison data. 相似文献
15.
Wang Qingeng Han Zhiwei Wang Tijian Higano Yoshiro 《Environmental science and pollution research international》2007,14(1):69-75
Background and Aim An accurate estimation of biogenic emissions of VOC (volatile organic compounds) is necessary for better understanding a series
of current environmental problems such as summertime smong and global climate change. However, very limited studies have been
reported on such emissions in China. The aim of this paper is to present an estimate of biogenic VOC emissions during summertime
in China, and discuss its uncertainties and potential areas for further investigations.
Materials and Methods This study was mainly based on field data and related research available so far in China and abroad, including distributions
of land use and vegetations, biomass densities and emission potentials. VOC were grouped into isoprene, monoterpenes and other
VOC (OVOC). Emission potentials of forests were determined for 22 genera or species, and then assigned to 33 forest ecosystems.
The NCEP/NCAR reanalysis database was used as standard environmental conditions. A typical summertime of July 1999 was chosen
for detailed calculations.
Results and Discussion The biogenic VOC emissions in China in July were estimated to be 2.3×1012gC, with 42% as isoprene, 19% as monoterpenes and 39% as OVOC. About 77.3% of the emissions are generated-from forests and
woodlands. The averaged emission intensity was 4.11 mgC m−2 hr−1 for forests and 1.12 mgC m−2 hr−1 for all types of vegetations in China during the summertime. The uncertainty in the results arose from both the data and
the assumptions used in the extrapolations. Generally, uncertainty in the field measurements is relatively small. A large
part of the uncertainty mainly comes from the taxonomic method to assign emission potentials to unmeasured species, while
the ARGR method serves to estimate leaf biomass and the emission algorithms to describe light and temperature dependence.
Conclusions This study describes a picture of the biogenic VOC emissions during summertime in China. Due to the uneven spatial and temporal
distributions, biogenic VOC emissions may play an important role in the tropospheric chemistry during summertime.
Recommendations and Perspectives Further investigations are needed to reduce uncertainties involved in the related factors such as emission potentials, leaf
biomass, species distribution as well as the mechanisms of the emission activities. Besides ground measurements, attention
should also be placed on other techniques such as remotesensing and dynamic modeling. These new approaches, combined with
ground measurements as basic database for calibration and evaluation, can hopefully provide more comprehensive information
in the research of this field.
Submission Editor: Prof. Dr. Gerhard Lammel (lammel@recetox.muni.cz) 相似文献
16.
L. Alonso N. Durana M. Navazo J.A. García J.L. Ilardia 《Journal of the Air & Waste Management Association (1995)》2013,63(8):916-924
ABSTRACT During a preliminary field campaign of volatile organic compound (VOC) measurements carried out in an urban area, two complementary analysis techniques were applied to establish the technical and scientific bases for a strategy to monitor and control VOCs and photochemical oxidants in the Autonomous Community of the Basque Country. Integrated sampling was conducted using Tenax sorbent tubes and laboratory analysis by gas chromatography, and grab sampling and in situ analysis also were conducted using a portable gas chromatograph. With the first technique, monocyclic aromatic hydrocarbons appeared as the compounds with the higher mean concentrations. The second technique allowed the systematic analysis of eight chlorinated and aromatic hydrocarbons. Results of comparing both techniques, as well as the additional information obtained with the second technique, are included. 相似文献
17.
18.
Alfred T. Hodgson Joan M. Daisey Richard A. Grot 《Journal of the Air & Waste Management Association (1995)》2013,63(11):1461-1468
This study was conducted at a newly constructed federal office building in Portland, Oregon. The primary objectives were to identify the major sources of volatile organic compounds (VOC) in the building and to measure both long-term (one year) and short-term (several day) variations in concentrations and source strengths. Samples for VOC were collected on four occasions over a period of 14 months starting with the first month of occupancy. During the final sampling period, samples were collected over four days (Friday - Monday). The samples were analyzed for individual compounds and for total VOC (TVOC). The results were expressed as specific source strengths, as well as concentrations, to facilitate comparisons of measurements made under different ventilation conditions. The primary source of VOC in the building was identified as liquid-process photocopiers and plotters which emitted a characteristic mixture of C10-Cn isoparaffinic hydrocarbons. The specific source strength of TVOC, which was dominated by the emissions from these office machines, remained relatively constant over the course of the study. Motor vehicles in the below-ground parking garage were implicated as another major source of hydrocarbons in the building. Over the final four-day sampling period, the specific source strength of TVOC varied by about a factor of five, predominantly reflecting occupant use of office machines. 相似文献
19.
Martin A. Cohen P. Barry Ryan Yukio Yanagisawa S. Katharine Hammond 《Journal of the Air & Waste Management Association (1995)》2013,63(7):993-997
Abstract Volatile organlcs compounds (VOCs) are ubiquitous in the air we breathe. The use of passive samplers to measure these concentrations can be an effective technique. When exposed for long durations, a passive sampler may be a good tool for investigating chronic exposures to chemicals in the environment. A passive sampler that was designed for occupational exposures can be used as such a tool. Laboratory validation under as many conditions as possible needs to be accomplished so as to characterize the sampler with known parameters. This paper describes the methods and results of an investigation into the validity of using a passive monitor to sample VOCs for a three-week period. Two concentration levels, two relative humidities, and five VOCs were studied. Results indicate that the samplers work best under conditions of high concentration with low relative humidity and low concentration with high relative humidity. For the passive sampler, excluding chloroform, percent deviations from the predicted values varied between ?41 and +22 percent; while the values between the passive and the active samplers varied between ?27 and +24 percent. Benzene, heptane, and perchloroethylene were sampled with equal precision and accuracy. 相似文献