首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 µm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38–99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1–1 µm. In this size range, ESP and baghouse collection efficiencies are 85.79–98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

2.
Abstract

Municipal Solid Waste incinerator residues produced in two types of facilities were exhaustively characterized: granulometry, mineralogy, chemical composition, leaching behavior, and elemental distribution as a function of particle size. Air Pollution Control (APC) residues coming from a semi-dry scrubber have shown higher solubility than fly ashes originating in an Electrostatic Precipitator (ESP), as well as higher contents in volatile metals (Cd, Hg). Different metal speciation and distribution as a function of particle size have been found in fly ashes (ESP residues) and APC residues. In APC residues, heavy metals (with the exception of Hg) show a parabolic distribution with maxima in the smallest and largest particles, following the same profile as soluble salts. Metal distribution for APC residues exhibits that metals generally are not associated with silicate aluminate matrix. Results show the effect of adding lime to APC residues in metal speciation and distribution.  相似文献   

3.
In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 microm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 microm. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

4.
ABSTRACT

Correct assessment of fine particulate carbonaceous material as a function of particle size is, in part, dependent on the determination of semi-volatile compounds, which can be lost from particles during sampling. This study gives results obtained for the collection of fine particulate carbonaceous material at three eastern U.S. sampling sites [Philadelphia, PA; Shenandoah National Park, VA; and Research Triangle Park (RTP), NC] using diffusion denuder technology. The diffusion denuder samplers allow for the determination of fine particulate organic material with no artifacts, due to the loss of semi-volatile organic particulate compounds, or collection of gas-phase organic compounds by the quartz filter during sampling. The results show that an average of 41, 43, and 59% of fine particulate organic material was lost as volatilized semi-volatile organic material during collection of particles on a filter at Philadelphia, RTP, and Shenandoah, respectively. The particle size distribution of carbonaceous material retained by a filter and lost from a filter during sampling was obtained for the samples collected at Philadelphia and Shenandoah. The carbonaceous material retained by the particles during sampling was found predominantly in particles smaller than 0.4 μm in aerodynamic diameter. In contrast, the semi-volatile organic material lost from the particles during sampling had a mass median diameter of ~0.5 μm.  相似文献   

5.
6.
To remove particles in corrosive gases generated by semiconductor industries, we have developed a novel non-metallic, two-stage electrostatic precipitator (ESP). Carbon brush electrodes and grounded carbon fiber-reinforced polymer (CFRP) form the ionization stage, and polyvinyl chloride collection plates are used in the collection stage of the ESP The collection performance of the ESP downstream of a wet scrubber was evaluated with KC1, silica, and mist particles (0.01-10 pm), changing design and operation parameters such as the ESP length, voltage, and flow rate. A long-term and regeneration performance (12-hr) test was conducted at the maximum operation conditions of the scrubber and ESP and the performance was then demonstrated for 1 month with exhaust gases from wet scrubbers at the rooftop of a semiconductor manufacturing plant in Korea. The results showed that the electrical and collection performance of the ESP (16 channels, 400x400 mm2) was maintained with different grounded plate materials (stainless steel and CFRP) and different lengths of the ionization stage. The collection efficiency of the ESP at high air velocity was enhanced with increases in applied voltages and collection plate lengths. The ESP (16 channels with 100 mm length, 400x400 mm2x540 mm with a 10-mm gap) removed more than 90% of silica and mistparticles with 10 and 12 kV applied to the ESPat the air velocity of 2 m/s and liquid-to-gas ratio of 3.6 L/m3. Decreased performance after 13 hours ofcontinuous operation was recovered to the initial performance level by 5 min of water washing. Moreover during the 1-month operation at the demonstration site, the ESP showed average collection efficiencies of 97% based on particle number and 92% based on total particle mass, which were achieved with a much smaller specific corona power of 0.28 W/m3/hr compared with conventional ESPs.  相似文献   

7.
Abstract

Particle emissions of modern diesel engines are of a particular interest because of their negative health effects. The special interest is in nanosized solid particles. The effect of an open channel filter on particle emissions of a modern heavy-duty diesel engine (MAN D2066 LF31, model year 2006) was studied. Here, the authors show that the open channel filter made from metal screen efficiently reduced the number of the smallest particles and, notably, the number and mass concentration of soot particles. The filter used in this study reached 78% particle mass reduction over the European Steady Cycle. Considering the size-segregated number concentration reduction, the collection efficiency was over 95% for particles smaller than 10 nm. The diffusion is the dominant collection mechanism in small particle sizes, thus the collection efficiency decreased as particle size increased, attaining 50% at 100 nm. The overall particle number reduction was 66–99%, and for accumulation-mode particles the number concentration reduction was 62–69%, both depending on the engine load.  相似文献   

8.
A novel two-stage wet electrostatic precipitator (ESP) has been developed using a carbon brush pre-charger and collection plates with a thin water film. The electrical and particle collection performance was evaluated for submicrometer particles smaller than 0.01- 0.5 micrometer in diameter by varying the voltages applied to the pre-charger and collection plates as well as the polarity of the voltage. The collection efficiency was compared with that calculated by the theoretical models. The long-term performances of the ESP with and without water films were also compared in tests using Japanese Industrial Standards dust. The experimental results show that the carbon brush pre-charger of the two-stage wet ESP had approximately 10% particle capture, while producing ozone concentrations of less than 30 ppb. The produced amounts of ozone are significantly lower than the current limits set by international agencies. The ESP also achieved a high collection rate performance, averaging 90% for ultrafine particles, as based on the particle number concentration at an average velocity of 1 m/sec corresponding to a residence time of 0.17 sec. Higher particle collection efficiency for the ESP can be achieved by increasing the voltages applied to the pre-charger and the collection plates. The decreased collection efficiency that occurred during dust loading without water films was completely avoided by forming a thin water film on the collection plates at a water flow rate of 6.5 L/min/m(2).  相似文献   

9.
This paper describes the evaluation of the performance of ESPs operating downstream of spray dryers in high- and medium-sulfur coal flue gas streams. Tests were conducted at the TV A10 MW Spray Dryer/ESP Pilot Plant and the EPRI High Sulfur Test Center. The results of the analysis of particle characteristics, spray dryer operating parameters, and ESP operating variables identify the occurrence of severe particle reentrainment due to the low resistivity (108 ohm-cm and lower) of the sorbent/flyash mixtures at low approach-tosaturation temperatures. The reentrainment has a significant impact on the collection efficiency of ESPs which could represent a fundamental limitation on their ability to adequately perform in this environment. Although this program has been focused on spray dryer applications, because of the similarities of the gas and particle characteristics produced from spray drying and other dry scrubbing processes, the results also have implications to duct slurry injection, dry sorbent injection with humidification, and processes involving furnace sorbent injection with humidification.

The performance characteristics of the ESPs are presented under both baseline and spray dryer conditions. The results are analyzed and the Southern Research Institute ESP Computer Model was used to evaluate the data. Special techniques for measuring particle resistivity at these conditions are described. A theoretical examination of particle reentrainment was undertaken which indicated that at low-resistivity levels the electrostatic forces reverse and tend to pull the particles off the plates with a force proportional to the square of the electric field. This repulsion of particles from the plates at spray dryer conditions was confirmed by laboratory experiments. Chloride content of the coal was found to be an important parameter effecting the performance of the ESP. Implications of the results of this evaluation relative to ESP upgrades are presented.  相似文献   

10.
Abstract

A novel photonic decontamination method was developed for removal of pollutants from material surfaces. Such a method relies on the ability of a high-energy laser beam to ablate materials from a contaminated surface layer, thus producing airborne particles. In this paper, the authors presented the results obtained using a scanning mobility particle sizer (SMPS) system and an aerosol particle sizer (APS). Particles generated by laser ablation from the surfaces of cement, chromium-embedded cement, and alumina were experimentally investigated. Broad particle distributions from nanometer to micrometer in size were measured. For stainless steel, virtually no particle >500 nm in aerodynamic size was detected. The generated particle number concentrations of all three of the materials were increased as the 266-nm laser fluence (millijoules per square centimeter) increased. Among the three materials tested, cement was found to be the most favorable for particle removal, alumina next, and stainless steel the least. Chromium (dropped in cement) showed almost no effects on particle production. For all of the materials tested except for stainless steel, bimodal size distributions were observed; a smaller mode peaked at ~50–70 nm was detected by SMPS and a larger mode (peaked at ~0.70–0.85 µm) by APS. Based on transmission electron microscopy observations, the authors concluded that particles in the range of 50–70 nm were aggregates of primary particles, and those of size larger than a few hundred nanometers were produced by different mechanisms, for example, massive object ejection from the material surfaces.  相似文献   

11.
Abstract

Motor vehicle emissions usually constitute the most significant source of ultrafine particles (diameter <0.1 μm) in an urban environment, yet little is known about the concentration and size distribution of ultrafine particles in the vicinity of major highways. In the present study, particle number concentration and size distribution in the size range from 6 to 220 nm were measured by a condensation particle counter (CPC) and a scanning mobility particle sizer (SMPS), respectively. Measurements were taken 30, 60, 90, 150, and 300 m downwind, and 300 m upwind, from Interstate 405 at the Los Angeles National Cemetery. At each sampling location, concentrations of CO, black carbon (BC), and particle mass were also measured by a Dasibi CO monitor, an aethalometer, and a DataRam, respectively. The range of average concentration of CO, BC, total particle number, and mass concentration at 30 m was 1.7?2.2 ppm, 3.4?10.0 μg/m3, 1.3?2.0 × 105/cm3, and 30.2?64.6 μ/m3, respectively.

For the conditions of these measurements, relative concentrations of CO, BC, and particle number tracked each other well as distance from the freeway increased. Particle number concentration (6–220 nm) decreased exponentially with downwind distance from the freeway. Data showed that both atmospheric dispersion and coagulation contributed to the rapid decrease in particle number concentration and change in particle size distribution with increasing distance from the freeway. Average traffic flow during the sampling periods was 13,900 vehicles/hr. Ninety-three percent of vehicles were gasoline-powered cars or light trucks. The measured number concentration tracked traffic flow well. Thirty meters downwind from the freeway, three distinct ultrafine modes were observed with geometric mean diameters of 13, 27, and 65 nm. The smallest mode, with a peak concentration of 1.6 × 105/cm3, disappeared at distances greater than 90 m from the freeway. Ultrafine particle number concentration measured 300 m downwind from the freeway was indistinguishable from upwind background concentration. These data may be used to estimate exposure to ultrafine particles in the vicinity of major highways.  相似文献   

12.
Abstract

Aerosol size distributions from ferrous foundry cupola furnaces vary depending on semicontinuous process dynamics, time along the tap-to-tap cycle, dilution ratio, and the physical and chemical nature of the charge and fuel. All of these factors result in a highly time-dependent emission of particulate matter (PM) 2.5 µm or less in aerodynamic diameter (PM2.5)—even on a mass concentration basis. Control measures are frequently taken on the basis of low-reliability parameters such as emission factors and loosely established mass ratios of PM2.5 to PM 10 µm or less in aerodynamic diameter (PM10). The new environmental requirements could entail unexpected and undesired drawbacks and uncertainties in the meaning and effectiveness of process improvement measures. The development of process-integrated and flue-gas cleaning measures for reduction of particle emissions requires a better knowledge of generation mechanisms during melting. Available aerosol analyzers expand the range of control issues to be tackled and contribute to greatly reduce the uncertainty of engineering decisions on trace pollutant control. This approach combines real-time size distribution monitoring and cascade impactors as preseparators for chemical or morphological analysis. The results allow for establishing a design rationale and performance requirement for control devices. A number size distribution below 10 µm in aerodynamic equivalent diameter was chosen as the main indicator of charge influence and filter performance. Size distribution is trimodal, with a coarse mode more than 12 µm that contributes up to 30% of the total mass. A temporal series for these data leads to identification of the most relevant size ranges for a specific furnace (e.g., the most penetrating size range). In this cupola, this size range is between 0.32 and 0.77 µm of aerodynamic equivalent diameter and defines the pollution control strategy for metals concentrating within this size range. Scrap quality effect is best monitored at less than 0.2 µm in aerodynamic equivalent diameter and has been confirmed as strongly dependent on the physical state of the charge.  相似文献   

13.
Abstract

This article is the first of a two-part series dealing with the effects of sorbent injection processes on particulate properties. Part I reviews the effects on particulate properties of low-temperature sorbent injection processes (those processes that treat flue gas at temperatures near 300 °F). Part II reviews the effects on particulate properties of high-temperature sorbent injection processes (those processes that involve sorbent injection into the combustion or economizer sections of a boiler). In this article, we review what is currently known about the effects of the low-temperature sorbent injection processes on electrical resistivity, particulate mass loading, particulate size distribution, particulate morphology and cohesivity.

Mixtures of ash and sorbent produced by low-temperature sorbent injection processes are typically less cohesive than most types of fly ash. At temperatures within 30 °F of the water dew point, the combination of low cohesivity and low electrical resistivity of the ash and sorbent mixtures can cause electrical reentrainment in electrostatic precipitators. Deliquescent additives such as calcium chloride cause the water to be retained on the particle surface, thereby increasing cohesivity.

Sorbent injection has been reported to increase the particulate mass loading by a factor of 1.8 to 10, depending upon the reagent ratio and the coal sulfur content. Conventional and in-duct spray drying processes tend to shift the particle size distribution toward larger particles, while dry injection processes tend to shift the particle size distribution toward smaller particles.  相似文献   

14.
物料下落过程中可吸入颗粒物产生特性及控制技术   总被引:1,自引:0,他引:1  
利用实验室新设计开发的一套装置,研究物料自由下落过程影响可吸入颗粒物产生的因素.通过实验分别测定不同物料、质量流量、含水量、粒径组成和下垫面5个因素对可吸入颗粒物产生的影响.实验结果表明,不同物料可吸入颗粒物产生率不同;随着质量流量和物料含水量的增加,可吸入颗粒物产生率减小,加水是减少可吸入颗粒物排放的最有效方法之一;不同粒径组成和不同下垫面对可吸入颗粒物产生也有影响,但作用并不显著.  相似文献   

15.
Abstract

The GRIMM model 1.107 monitor is designed to measure particle size distribution and particulate mass based on a light scattering measurement of individual particles in the sampled air. The design and operation of the instrument are described. Protocols used to convert the measured size number distribution to a mass concentration consistent with U.S. Environmental Protection Agency protocols for measuring particulate matter (PM) less than 10 μm (PM10) and less than 2.5 μm (PM2.5) in aerodynamic diameter are described. The performance of the resulting continuous monitor has been evaluated by comparing GRIMM monitor PM2.5 measurements with results obtained by the Rupprecht and Patashnick Co. (R&P) filter dynamic measurement system (FDMS). Data were obtained during month-long studies in Rubidoux, CA, in July 2003 and in Fresno, CA, in December 2003. The results indicate that the GRIMM monitor does respond to total PM2.5 mass, including the semi-volatile components, giving results comparable to the FDMS. The data also indicate that the monitor can be used to estimate water content of the fine particles. However, if the inlet to the monitor is heated, then the instrument measures only the nonvolatile material, more comparable to results obtained with a conventional heated filter tapered element oscillating microbalance (TEOM) monitor. A recent modification of the model 180, with a Nafion dryer at the inlet, measures total PM2.5 including the nonvolatile and semi-volatile components, but excluding fine particulate water. Model 180 was in agreement with FDMS data obtained in Lindon, UT, during January through February 2007  相似文献   

16.
Electrostatic precipitation is considered as an effective technology for fine particle removal. A lab-scale wet electrostatic precipitator (ESP) with wire-to-plate configuration was developed to study particle migration and collection. The performance of the wet ESP was evaluated in terms of the corona discharge characteristics, total removal efficiency and fractional removal efficiency. The corona discharge characteristics and particle removal abilities of the wet ESP were investigated and compared with dry ESP. Particle removal efficiency was influenced by discharge electrode type, SO2 concentration, specific collection area (SCA) and particle/droplet interaction. Results showed that the particle removal efficiency of wet ESP was elevated to 97.86% from 93.75% of dry ESP. Three types of discharge electrodes were investigated. Higher particle removal efficiency and larger migration velocity could be obtained with fishbone electrode. Particle removal efficiency decreased by 2.87% when SO2 concentration increased from 0 ppm to 43 ppm as a result of the suppression of corona discharge and particle charging. The removal efficiency increased with higher SCA, but it changed by only 0.71% with the SCA increasing from 25.0 m2/(m3/s) to 32.5 m2/(m3/s). Meanwhile, the increasing of particle and droplet concentration was favorable to the particle aggregation and improved particle removal efficiency.

Implications: This work tends to study the particle migration and collection under spraying condition. The performance of a wet electrostatic precipitator (ESP) is evaluated in terms of the corona discharge characteristics, total particle removal efficiency, and fractional particle removal efficiency. The effects of water droplets on particle removal, especially on removal of particles with different sizes, is investigated. The optimization work was done to determine appropriate water consumption, discharge electrode type, and specific collection area, which can provide a basis for wet ESP design and application.  相似文献   


17.
ABSTRACT

Measurements collected using five real-time continuous airborne particle monitors were compared to measurements made using reference filter-based samplers at Bakers-field, CA, between December 2, 1998, and January 31, 1999. The purpose of this analysis was to evaluate the suitability of each instrument for use in a real-time continuous monitoring network designed to measure the mass of airborne particles with an aerodynamic diam less than 2.5 μm (PM2.5) under wintertime conditions in the southern San Joaquin Valley. Measurements of airborne particulate mass made with a beta attenuation monitor (BAM), an integrating nephelometer, and a continuous aerosol mass monitor (CAMM) were found to correlate well with reference measurements made with a filter-based sampler. A Dusttrak aerosol sampler overestimated airborne particle concentrations by a factor of ~3 throughout the study. Measurements of airborne particulate matter made with a tapered element oscillating microbalance (TEOM) were found to be lower than the reference filter-based measurements by an amount approximately equal to the concentration of NH4NO3 observed to be present in the airborne particles. The performance of the Dusttrak sampler and the integrating nephelometer was affected by the size distribution of airborne particulate matter. The performance of the BAM, the integrating nephelometer, the CAMM, the Dusttrak sampler, and the TEOM was not strongly affected by temperature, relative humidity, wind speed, or wind direction within the range of conditions encountered in the current study. Based on instrument performance, the BAM, the integrating nephelometer, and the CAMM appear to be suitable candidates for deployment in a real-time continuous PM2.5 monitoring network in central California for the range of winter conditions and aerosol composition encountered during the study.  相似文献   

18.
Exhaust gas particle and ion size distributions were measured from an off-road diesel engine complying with the European Stage IIIB emission standard. The measurements were performed at idling and low load conditions on an engine dynamometer. Nucleation-mode particles dominated the diesel exhaust particle number emissions at idle load. The nonvolatile nucleation-mode geometric mean diameter was detected at 10 nm or below. The nonvolatile nucleation-mode charge state implied that it has evolved through a highly ionizing environment before emission from the engine. The determined charging probabilities were 10.0 ± 2.2% for negative and 8.0 ± 2.0% for positive polarity particles. The nonvolatile nucleation particle concentration and size was also shown to be dependent on the lubricant oil composition. The particle emissions were efficiently controlled with a partial filter or with partial filter + selective catalytic reduction (SCR) combination. The particle number removal efficiencies of the aftertreatment systems were over 95% for wet total particle number (>3nm) and over 85% for dry particle total number. Nevertheless, the aftertreatment systems’ efficiencies were around 50% for the soot-mode particles. The low-load nonvolatile nucleation particle emissions were also dependent on the engine load, speed, and fuel injection pressure. The low load particle number emissions followed the soot-core trade-off, similar to medium or high operating loads.
Implications:Idling and low-load diesel engine exhaust emissions affect harmfully the ambient air quality. The low-load particle number emissions are here shown to peak in the 10-nm size range for a modern off-road engine. The particles are electrically charged and nonvolatile and they originate from the combustion process. Tailpipe particle control by open channel filter can remove more than 85% of the nonvolatile 10-nm particles and about 50% of the soot-mode particles, while the fuel injection pressure increase can lead to particle number increase. The study provides a new viewpoint for low-load particle emissions and control.  相似文献   

19.
ABSTRACT

Day- and nighttime total suspended particulate matter was collected inside and outside Emperor Qin's Terra-Cotta Museum in winter and summer 2008. The purpose was to characterize the winter and summer differences of indoor airborne particles in two display halls with different architectural and ventilation conditions, namely the Exhibition Hall and Pit No. 1. The morphology and elemental composition of two season samples were investigated using scanning electron microscopy and energy dispersive X-ray spectrometry. It is found that the particle size, particle mass concentration, and particle type were associated with the visitor numbers in the Exhibition Hall and with the natural ventilation in Pit No. 1 in both winter and summer. Evident winter and summer changes in the composition and physicochemical properties of the indoor suspended particulate matters were related to the source emission and the meteorological conditions. Particle mass concentrations in both halls were higher in winter than in summer. In winter, the size of the most abundant particles at the three sites were all between 0.5 and 1.0 μm, whereas in summer the peaks were all located at less than 0.5 μm. The fraction of sulfur-containing particles was 2–7 times higher in winter than in summer. In addition to the potential soiling hazard, the formation and deposition of sulfur-containing particles in winter may lead to the chemical and physical weathering of the surfaces of the terra-cotta statues.

IMPLICATIONS Relatively few microanalyses of indoor airborne particles inside museums in China have been performed. The mass concentrations of winter and summer indoor total suspended particulate (TSP) are presented for the Emperor Qin's Terra-Cotta Museum along with the characterization of individual particles via computerized scanning electron microscopy and an energy dispersive X-ray spectrometry. The results indicate that both the high level of particle mass concentrations in winter and the predominant fine particles in summer were responsible for the soiling of the statues over a long period of time. The irreplaceable statues were also facing with weathering hazards posed by abundant sulfur-containing particles, especially in winter. Data provided in this study suggested that mechanical ventilation, air filtration, and air conditioning systems should be installed in Pit No. 1 display hall and proper display strategy should be adopted in Exhibition Hall.  相似文献   

20.
粉尘对电除尘器气流分布影响仿真研究   总被引:4,自引:3,他引:1  
为了更加精确地研究电除尘器入口气流分布特征, 论文采用欧拉-拉格朗日多相流模型,对电除尘器内部气流分布进行了数值仿真。由于在进入除尘器的气流中引入了粉尘粒子,不仅可获得粉尘及粉尘颗粒粒径大小对气流分布均匀性的影响,而且这种模拟更加接近除尘器的气流实际情况。提出的模拟方法为电除尘器的气流分析提供了一条新的途径。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏