首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

This paper describes a statistical method to assess site redundancy of urban air monitoring networks in reporting daily Pollutant Standards Index (PSI), average concentrations, and the number of exceedances. Such a statistical method has identified significant redundancy in monitoring sites for one-year measurements of two air monitoring networks in Taiwan. There are five redundant sites out of 15 monitoring sites in the Taipei area and eight redundant sites out of 18 monitoring sites in the Kaohsiung area. By using the statistical method presented in this paper to downsize the monitoring networks, we can determine not only the number of redundant sites but also the priority of site removals. The derived sub-networks can maintain consistency in reporting air quality without significant changes in the spatial variations of air measurements for an existing air monitoring network.  相似文献   

2.
Abstract

This study investigated the relationships between meteorological data, pollution sources, and receptors over northern Taiwan. During the intensive sampling period in summer 1992, the weather was controlled predominantly by a Pacific subtropical high and by Typhoon Mark. During the other intensive sampling period in winter 1993, while a cold frontal system approached Taiwan, the northeasterly winds prevailed most of the time. The local circulation such as land-sea breeze only developed under weak synoptic environment. Particle concentrations and element composition in winter were higher than in summer. This can be attributed to the high convection of air mass, which leads to the vertical dispersion of pollutants in summer. In addition to the subtropical high pressure, typhoons are frequently accompanied with high-wind speeds and unstable weather conditions that also dilute and eliminate the pollutants. In winter, the prevailing northeasterlies might carry pollutants from Midland China. Furthermore, the anticyclone system develops a stagnant condition that easily leads to pollutant accumulation. In this case, the wind direction affected the source contribution of the receptor and the PM10 displays a higher correlation with coarse and fine particulate than meteorological parameters in summer. In addition, the mixing height shows a high correlation with PM10 in winter.  相似文献   

3.
This paper presents an overview on air pollution assessments of new fossil energy technologies for baseload electric generating plants. The discussion is oriented towards those who must understand the broad issues affecting the design and performance of such power plants. It is motivated by the potential air pollution problems caused by the near doubling of coal use projected for the next 15 years.

The paper first reviews the applicable emissions performance standards for these plants, as well as predictions of likely future standards needed to protect the environment. The conclusion is reached that significantly tighter emissions standards will apply in the future.

Next, the cost, emissions performance, and development status of the three major technology groups for coal fired baseload plants are reviewed. It is observed that while all of the technologies can meet the current standards, only the Baseline plant with Advanced Control Technology can meet future standards, without unreasonable increases in electrical generation costs. Furthermore, since Advanced Direct Combustion Technologies and Fuel Conversion Technologies are in very early stages of development, only the Baseline plant with Advanced Control Technology will be available to the utilities in the near term. This is because it will be evolved from the current commercial Baseline Technology.

Hence, it is concluded that the utilities will use mainly the Baseline coal fired plant with Advanced Control Technology to protect the environment for the next 15-20 years.  相似文献   

4.
ABSTRACT

Indoor air quality has become a critical issue because people spend most of their time in the indoor environment. The factors that influence indoor air quality are very important to environmental sanitation and air quality improvement. This study focuses on monitoring air quality, colony counts, and bacteria species of the indoor air of a nursing care institution. The regular colony counts in two different wards range from 55 to 600 cfu m?3. Regression analysis results indicate that the bacterial colony counts have close correlation with relative humidity or carbon dioxide (CO2) but not with carbon monoxide (CO) or ozone (O3). Real-time PCR was used to quantify the bacterial pathogens of nosocomial infection, including Acinetobacter baumannii, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, and methicillin-sensitive Staphylococcus aureus. The most abundant bacteria species in the air of the nursing care institution is E. coli.
IMPLICATIONS Indoor temperature, humidity, ventilation, accumulation of biological pollutants, and potential infection problems will seriously affect the indoor environments. Studying these factors is important to indoor environmental sanitation and air quality improvements. Results of using real-time PCR to evaluate the bacterial pathogens of nosocomial infection for a nursing care institution in Taiwan reveal that the main bacteria species existing in the indoor air is E. coli.  相似文献   

5.
This overview represents much of the discussion and summarizes many of the concerns emerging from the recent APCA Specialty Conference, “In-Situ Air Quality Monitoring from Moving Platforms.”

Users of mobile air quality monitoring systems have been hampered in their attempts to generate dependable data because of a lack of suitable instrumentation. Most equipment used in mobile systems was designed for laboratory or stationary monitoring applications and cannot cope well with the harsh environment encountered in aircraft or other mobile platforms. Only through innovative modifications have investigators been able to utilize off-the-shelf equipment. The technology exists, however, for manufacturers to build a much higher quality product if only a market incentive could be created.

This paper outlines problem areas which need to be addressed in the production of reliable “mobile quality” instrumentation, and suggests some market incentives.  相似文献   

6.
Abstract

The ambient air quality standards (AAQS) of twenty-one nations for eight commonly regulated substances are presented. Many countries are adding a receptor-based component to their air quality management, which traditionally have been emission oriented. Automation of air quality monitoring stations has meant that local air quality evaluation can now be more easily achieved. However, a majority of countries have no active air quality standards (emission or receptor-based) or ambient air quality monitoring. One possible monitoring procedure is outlined and the variation in international standards is discussed.  相似文献   

7.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

8.
Abstract

A huge amount of volatile organic compounds (VOCs) is produced and emitted with waste gases from semiconductor manufacturing processes, such as cleaning, etching, and developing. VOC emissions from semiconductor factories located at Science-Based Industrial Park, Hsin-chu, Taiwan, were measured and characterized in this study. A total of nine typical semiconductor fabricators (fabs) were monitored over a 12-month period (October 2000-September 2001). A flame ionization analyzer was employed to measure the VOC emission rate continuously in a real-time fashion. The amount of chemical use was adopted from the data that were reported to the Environmental Protection Bureau in Hsin-chu County as per the regulation of the Taiwan Environmental Protection Administration. The VOC emission factor, defined as the emission rate (kg/month) divided by the amount of chemical use (L/month), was determined to be 0.038 ± 0.016 kg/L. A linear regression equation is proposed to fit the data with the correlation coefficient (R2) = 0.863. The emission profiles of VOCs, which were drawn using the gas chromatograph/mass spectrometer analysis method, show that isopropyl alcohol is the dominant compound in most of the fabs.  相似文献   

9.
ABSTRACT

A comprehensive indoor particle characterization study was conducted in nine Boston-area homes in 1998 in order to characterize sources of PM in indoor environments. State-of-the-art sampling methodologies were used to obtain continuous PM2.5 concentration and size distribution particulate data for both indoor and outdoor air. Study homes, five of which were sampled during two seasons, were monitored over week-long periods. Among other data collected during the extensive monitoring efforts were 24hr elemental/organic carbon (EC/OC) particulate data as well as semi-continuous air exchange rates and time-activity information.

This rich data set shows that indoor particle events tend to be brief, intermittent, and highly variable, thus requiring the use of continuous instrumentation for their characterization. In addition to dramatically increasing indoor PM25 concentrations, these data demonstrate that indoor particle events can significantly alter the size distribution and composition of indoor particles. Source event data demonstrate that the impacts of indoor activities are especially pronounced in the ultrafine (da < 0.1 um) and coarse (2.5 < da < 10 |um) modes. Among the sources of ultrafine particles characterized in this study are indoor ozone/terpene reactions. Furthermore, EC/OC data suggest that organic carbon is a major constituent of particles emitted during indoor source events. Whether exposures to indoor-generated particles, particularly from large short-term peak events, may be associated with adverse health effects will become clearer when biological mechanisms are better known.  相似文献   

10.
Abstract

Combinations of total reactive organic gas (ROG) and nitrogen oxide (NOx) emissions that do not exceed the National Ambient Air Quality Standard (NAAQS) for ozone for the meteorological conditions of the August 26-28, 1987 SCAQS episode, have been determined using the California Institute of Technology (CIT) photochemical air quality model. The sensitivity of these combinations to pollutant boundary conditions is examined.  相似文献   

11.
ABSTRACT

Non-methane organic carbon (NMOC) is a measure of total organic carbon in an air emission, excluding that from methane. Thus, it measures the total amount of carbon, irrespective of the structure and functional groups in the molecule. The U.S. Environmental Protection Agency (EPA) Method 25 is used for quantification of NMOC in emission sources and in ambient air. This method involves laboratory analysis of collected air samples and cannot be used for real-time measurements. It is prone to interferences from CO2, CH4, and CO, as well as moisture. In this paper, a novel method for continuous, on-line monitoring of NMOC in air emissions and ambient air is presented. Detection limits are at ppb levels, and interference of permanent gases have been eliminated.  相似文献   

12.
This study used pollution roses to assess sulfur dioxide (SO2) pollution in a township downwind of a large petrochemical complex based on data collected from a single air quality monitoring station. The pollution roses summarized hourly SO2 concentrations at the Taishi air quality monitoring station, located approximately 7.8–13.0 km south of the No. 6 Naphtha Cracking Complex in Taiwan, according to 36 sectors of wind direction during the preoperational period (1995–1999) and two postoperational periods (2000–2004 and 2005–2009). The 99th percentile of hourly SO2 concentrations 350? downwind from the complex increased from 28.9 ppb in the preoperational period to 86.2–324.2 ppb in the two postoperational periods. Downwind SO2 concentrations were particularly high during 2005–2009 at wind speeds of 6–8 m/sec. Hourly SO2 levels exceeded the U.S. Environmental Protection Agency (EPA) health-based standard of 75 ppb only in the postoperational periods, with 65 exceedances from 0–10? and 330–350? downwind directions during 2001–2009. This study concluded that pollution roses based on a single monitoring station can be used to investigate source contributions to air pollution surrounding industrial complexes, and that it is useful to combine such directional methods with analyses of how pollution varies between different wind speeds, times of day, and periods of industrial development.

Implications: The pollution roses summarize SO2 concentrations by wind direction and to investigate source contribution to air quality. Percentile statistics can catch pollution episodes occurring in a very short time at specific wind directions and speeds. The downwind areas have already exceeded regulated 1-hr SO2 standard since the operation of the complex.  相似文献   

13.
ABSTRACT

In order to evaluate the spatial variation of aerosol (particulate matter with aerodynamic diameter ≤10 μm [PM10]) and ozone (O3) concentrations and characterize the atmospheric conditions that lead to O3 and PM10-rich episodes in southern Italy during summer 2007, an intensive sampling campaign was simultaneously performed, from middle of July to the end of August, at three ground-based sites (marine, urban, and high-altitude monitoring stations) in Calabria region. A cluster analysis, based on the prevailing air mass backward trajectories, was performed, allowing to discriminate the contribution of different air masses origin and paths. Results showed that both PM10 and O3 levels reached similar high values when air masses originated from the industrialized continental Europe as well as under the influence of wildfire emissions. Among natural sources, dust intrusion and wildfire events seem to involve a marked impact on the recorded data. Typical fair weather of Mediterranean summer and persisting anticyclone system at synoptic scale were indeed favorable conditions to the arrival of heavily dust-loaded air masses over three periods of consecutive days and more than half of the observed PM10 daily exceedances have been attributed to Saharan dust events. During the identified dust outbreaks, a consistent increase in PM10 levels with a concurrent decrease in O3 values was also observed and discussed.

IMPLICATIONS In the summertime, the central-southern Mediterranean Basin is heavily affected by Saharan dust outbreaks and wildfire events. A focus on their significant influence on either oxidizing capacity of the atmosphere and air quality over Calabria, southern Italy, was here presented. Similar studies for most regions surrounding the Mediterranean Basin are needed to implement effective emission reduction measures, to prevent apparent air quality parameter exceedances and to define an appropriate health alert system. Because the frequency of these events is expected to increase due to climate change, these studies could even be a valid effort to better understand and characterize such atmospheric variations.  相似文献   

14.
Abstract

The patented Carver-Greenfield (C-G) Process®, a combination of dehydration and solvent extraction treatment technologies, has a wide range of uses in separating hydrocarbon solvent-soluble hazardous organic contaminants (indigenous oil) from sludges, soils, and industrial wastes. As a result of this treatment, the products from a C-G Process facility are: ? Clean, dry solids which are typically suitable for disposal in nonhazardous landfills;

? Water which is treatable in an industrial or Publicly Owned Treatment Works (POTW) wastewater treatment facility;

? Extracted indigenous oil containing hydrocarbon soluble contaminants which may be recycled or reused or disposed of at less cost because its volume is smaller than the original waste feed.

The C-G Process was demonstrated on spent oily drilling fluids as part of the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation (SITE) Program. This paper summarizes the use of the C-G Process for economical treatment and minimization of hazardous refinery wastes, reviews the SITE program results, and describes extending the C-G Process technology to treatment of other wastes. Estimated treatment costs are presented.  相似文献   

15.
Abstract

Air pollution directional risk (APDR) is an essential factor to be assessed when selecting an appropriate landfill site. Because air pollutants generated from a landfill are diffused and transported by wind in different directions and speeds, areas surrounding the landfill will be subject to different associated risks, depending on their relative position from the landfill. This study assesses potential APDRs imposed from a candidate landfill site on its adjacent areas on the basis of the pollutant distribution simulated by a dispersion model, wind directions and speeds from meteorological monitoring data, and population density. A pollutant distribution map layer was created using a geographic information system and layered onto a population density map to obtain an APDR map layer. The risk map layer was then used in this study to evaluate the suitability of a candidate site for placing a landfill. The efficacy of the proposed procedure was demonstrated for a siting problem in central Taiwan, Republic of China.  相似文献   

16.
Abstract

Transit traffic through the Austrian Alps is of major concern in government policy. Pollutant burdens resulting from such traffic are discussed widely in Austrian politics and have already led to measures to restrict traffic on transit routes. In the course of an environmental assessment study, comprehensive measurements were performed. These included air quality observations using passive samplers, a differential optical absorption spectroscopy system, a mobile and a fixed air quality monitoring station, and meteorological observations. As was evident from several previous studies, dispersion modeling in such areas of complex terrain and, moreover, with frequent calm wind conditions, is difficult to handle. Further, in the case presented here, different pollutant sources had to be treated simultaneously (e.g., road networks, exhaust chimneys from road tunnels, and road tunnel portals). No appropriate system for modeling all these factors has so far appeared in the literature. A prognostic wind field model coupled with a Lagrangian dispersion model is thus presented here and is designed to treat all these factors. A comparison of the modeling system with results from passive samplers and from a fixed air quality monitoring station proved the ability of the model to provide reasonable figures for concentration distributions along the A10.  相似文献   

17.
Abstract

The Coordinating Research Council convened two Real-Time PM Measurement Workshops in December 2008 and March 2009 to take an intensive look at the current status and future directions of combustion aerosol measurement. The purpose was to examine the implications of parallel rapid developments over the past decade in ambient aerosol science, engine aftertreatment technology, and aerosol measurement methodology, which provide bene?ts and challenges to the stakeholders in air quality management. The workshops were organized into sessions targeting key issues in ambient and source combustion particulate matter (PM). These include (1) metrics to characterize and quantify PM, (2) the need to reconcile ambient and source measurements, (3) the role of atmospheric transformations on modeling emissions and exposures, (4) the impact of sampling conditions on PM measurement, and (5) the potential bene?ts of novel PM instrumentation. This paper distills the material presented by subject experts and the insights derived from the in-depth discussions that formed the core of each session. The paper’s objectives are to identify areas of consensus that allow wider practical application of the past decade’s advances in combustion aerosol measurement to improve emissions and air quality modeling, develop emissions reduction strategies, and to recommend directions for progress on issues in which uncertainties remain.  相似文献   

18.
Abstract

Range gas consumption in households tends to follow an annual cycle resembling a sinusoid, with peak consumption during the winter. When outdoor NO2 concentrations have a constant or small impact, the resulting indoor NO2 concentrations also tend to resemble an annual sinusoid. Optimal monitoring strategies can be designed to take advantage of this knowledge to obtain a better estimate of the true annual average gas consumption or indoor NO2 concentration. Gas consumption data, together with measured outdoor concentrations, house volumes, sampled emission rates, air exchange rates, and NO2 decay rates, are used to model weekly indoor NO2 concentrations throughout the year. Based on the modeling results, various monitoring strategies are evaluated for their accuracy in estimating the annual mean. Analysis of the results indicates that greater accuracy is attained using samples equally spaced throughout the year. In addition, the expected error for various monitoring strategies and various numbers of equally spaced samples is quantified, and their ability to classify homes into correct concentration categories is assessed.  相似文献   

19.
Abstract

The present work focuses on the characterization of air quality and the identification of pollutant origin at a former mining site in the city of Lavrion, Greece. A historical metallurgy complex is reused for establishing the Lavrion Technology and Cultural Park (LTCP). A serious problem with this is the severe soil contamination that resulted from intensive mining and metallurgical activities that has taken place in the greater area for the past 3000 years. Among other consequences, surface-polluted depositions, rich in heavy and toxic metals, are loose and easily wind-eroded, resulting in transportation of particu-late matter (PM) in the surrounding atmosphere. On the other hand, there are a number of industries relatively close to the site that are potential sources of PM air pollution. The current study deals with the collection and analysis of PM10 samples with respect to their concentration in heavy metals, such as Pb, Cd, Cu, Fe, Zn, Mn, Cr, and Ni. Though not a heavy metal, As also is included. Furthermore, the source of these elements is verified using statistical correlation and by calculating enrichment factors (EFs), considering that some substances are certainly of contaminated soil origin. Results show that PM10 and element concentrations are relatively low during winter but significantly increase during summer. Fe, Pb, Zn, Mn, and Cu may be considered of contaminated soil origin, while As, Ni, Cd, and Cr are very much enriched with respect to contaminated soil, indicating another possible source attributed to the adjacent industrial plants.  相似文献   

20.
This study investigated the indoor air quality (IAQ) conditions of carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), formaldehyde (HCHO), total volatile organic compounds (TVOCs), and bio-aerosols (bacteria and fungi) in a respiratory type of medical facility in Chia-Yi County in southern Taiwan. Among those IAQ conditions, the concentrations of CO, O3, and HCHO exceeded the regulation values of the Taiwan Environmental Protection Administration (EPA) mostly in the morning. The concentrations of bacteria and fungi did not exceed the regulation values but still posed potential health and environment problems for workers, patients, and visitors. Therefore, self-made silver-coated zeolite (AgZ) was used as a filter material in air cleaners to remove bio-aerosols in the respiratory care ward (RCW), and the removals were still effective after 120 hr. The cumulative bio-aerosol removals for bacteria and fungi were 900 and 1,088 colony-forming units (CFU) g?1 after 24 hr and were above 3,100 and 2,700 CFU g?1 after 120 hr. From the research results, it is suggested that AgZ filtering could be used as a feasible engineering measure for hospitals to control their bacteria and fungi parameters in IAQ management. Hospitals should maintain their environmental management and monitoring programs and use different engineering measures to improve different IAQ parameters.

Implications: This study investigated the IAQ conditions in the field at a hospital in Chia-Yi County in southern Taiwan. Although concentrations of most parameters were still within the regulation values, the concentrations of CO, O3, and HCHO were partially exceeded. We propose a method using an air cleaner with silver-coated zeolite (AgZ) as a possible engineering measure, and there were effective reductions of bacteria and fungi to lower levels with antibacterial effects after 120 hr. Furthermore, this study implies that hospitals should continuously maintain environmental monitoring programs and adopt optimal engineering measures for different needs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号