首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Controlled bench-scale laboratory experiments were conducted to evaluate the recovery of ammonia (NH3) and hydrogen sulfide (H2S) from dynamic isolation flux chambers. H2S (80-4000 ppb) and NH3 (5000-40,000 ppb) samples were diffused through the flux chamber to simulate ground level area source emissions while measuring the inlet and outlet flux chamber concentrations simultaneously. Results showed that the recovery of H2S during a 30-min sampling time was almost complete for concentrations >2000 ppb. At the lowest concentration of 80 ppb, 92.55% of the H2S could be recovered during the given sampling period. NH3 emissions exhibited similar behavior between concentrations of 5000-40,000 ppb. Within the 30-min sampling period, 92.62% of the 5000-ppb NH3 sample could be recovered. Complete recovery was achieved for concentrations >40,000 ppb. Predictive equations were developed for gas adsorption. From these equations, the maximum difference between chamber inlet and outlet concentrations of NH3 or H2S was predicted to be 7.5% at the lowest concentration used for either gas. In the calculation of emission factors for NH3 and H2S, no adsorption correction factor is recommended for concentrations >37,500 ppb and 2100 ppb for NH3 and H2S, respectively. The reported differences in outlet and inlet concentration above these ranges are outside the fullscale sensitivity of the gas sensing equipment. The use of 46-90 m of Teflon tubing with the flux chambers has apparently no effect on gas adsorption, because recovery was completed almost instantaneously at the beginning of the tests.  相似文献   

2.
Biotreatment of various ratios of H2S and NH3 gas mixtures was studied using the biofilters, packed with co-immobilized cells (Arthrobacter oxydans CH8 for NH3 and Pseudomonas putida CH11 for H2S). Extensive tests to determine removal characteristics, removal efficiency, removal kinetics, and pressure drops of the biofilters were performed. To estimate the largest allowable inlet concentration, a prediction model was also employed. Greater than 95% and 90% removal efficiencies were observed for NH3 and H2S, respectively, irrespective of the ratios of H2S and NH3 gas mixtures. The results showed that H2S removal of the biofilter was significantly affected by high inlet concentrations of H2S and NH3. As high H2S concentration was an inhibitory substrate for the growth of heterotrophic sulfur-oxidizing bacteria, the activity of H2S oxidation was thus inhibited. In the case of high NH3 concentration, the poor H2S removal efficiency might be attributed to the acidification of the biofilter. The phenomenon was caused by acidic metabolite accumulation of NH3. Through kinetic analysis, the presence of NH3 did not hinder the NH3 removal, but a high H2S concentration would result in low removal efficiency. Conversely, H2S of adequate concentrations would favor the removal of incoming NH3. The results also indicated that maximum inlet concentrations (model-estimated) agreed well with the experimental values for space velocities of 50–150 h−1. Hence, the results would be used as the guideline for the design and operation of biofilters.  相似文献   

3.
The study reported by this paper involves the use of the Controlled Condensation System (Goksoyr/Ross Coil) for flue gas S03 measurements in both the laboratory and the field, under low and high mass loadings. The Controlled Condensation System cools the flue gas to below the dewpoint of H2S04 but above the H20 dewpoint. The resulting aerosol is collected either on the coil walls or on the back-up glass frit. The laboratory recovery of the H2S04 in streams of varying S02, H20, and H2S04 content was found to be 95 ± 6%. A new quartz filter holder was designed to meet the filtration problems encountered in collecting S03 from particle laden flue gas streams. This quartz system, when heated to above 250°C, quantitatively passed the H2S04 into the condensation coil. Later studies with this filter system preloaded with fly ash equivalent to a mass loading of 1.3 g/m3 yielded a 80-85% recovery of H2S04. The laboratory system was simultaneously tested at a 150 megawatt, pulverized coal-fired power plant prior to and after a wet limestone FGD. The inlet grain loading to the FGD ranged from 0.06 g/m3 to 11.4 g/m3 with S02 concentrations as high as 4000 ppm. The average inlet H2S04 value was 8.3 ppm and the outlet from the FGD was 3.1 ppm. The source fluctuation value was determined to be ±65%.  相似文献   

4.
The kinetics of H2S oxidation in a biofilter were evaluated and the reaction rates determined to be first-order at low concentrations (<200 ppm), zero-order at high concentrations (>400 ppm), and fractional-order in the intermediate concentration range for H2S in the inlet waste gas. The overall performance of the biofilter system and changes in compost properties were investigated for 200 days of operation. The compost biofiiter showed good buffering capacities to variations in gas flow rate and pollutant (H2S) loading impacts. Hydrogen sulfide removal efficiencies exceeding 99.9% were consistently observed. System acidification and sulfate accumulation were identified as inhibitors of required biological activity. Routine washing of the compost effectively mitigated these deficiencies. System upset was determined to be caused by compost dry-out or system overloading. Methods were developed to provide for recovery of contaminated filter material.  相似文献   

5.
Abstract

The objective of this study was to obtain diurnal variation profiles of odor and gas (ammonia [NH3], hydrogen sulfide [H2S], carbon dioxide [CO2]) concentrations and emission rate (OGCER) from confined swine grower/finisher rooms under three typical weather conditions (warm, mild, and cold weather) in a year. Two grower/finisher rooms, one with a fully slatted floor and the other with partially slatted floors, were measured for 2 consecutive days under each weather condition. The results revealed that the diurnal OGCER in the room with a fully slatted floor was 9.2–39.4% higher than that with a partially slatted floor; however, no significant differences in the diurnal OGCER were found between these two rooms, except for the NH3 concentrations in August, the NH3 and H2S concentrations and emissions in October, and odor concentrations and emissions in February (p > 0.05). The OGCER variations presented different diurnal patterns as affected by time of day, season, type of floor, ventilation rate, animal growth cycles, in-house manure storage, and weather conditions. Significant diurnal fluctuations in the OGCER (except for the odor concentrations and H2S emissions) were observed in August (p < 0.05); all of the gas emissions in October and the CO2 concentrations and emissions in February also showed significant diurnal variations (p < 0.05). These significant diurnal variations indicated that the OGCER during different periods of a day should be monitored when quantifying OGCER concentrations and emissions; for example, source emission data used in air dispersion modeling to decrease the great incertitude of setback determination using randomly measured data.  相似文献   

6.
Abstract

Simultaneous removal of NH3 and H2S was investigated using two types of biofilters—one packed with wood chips and the other with granular activated carbon (GAC). Experimental tests and measurements included analyses of removal efficiency (RE), metabolic products, and results of long-term operation (around 240 days). The REs for NH3 and H2S were 92 and 99.9%, respectively, before deactivation. After deactivation, the RE for NH3 and H2S were decreased to 30–50% and 75%, respectively. The activity of nitrifying bacteria was inhibited by high concentrations of H2S (over 200 ppm) but recovered gradually after H2S addition was ceased. However, the Thiobacillus thioparus as sulfur oxidizing bacteria did not show inhibition at the NH3 concentration under 150-ppm conditions. The deactivation of the biofilter was caused by metabolic products [elemental sulfur and (NH4)2SO4] ac-cumulating on the packing materials during the extended operation. The removal capacities for NH3 and H2S were 6.0–8.0 and 45–75 mg N, S/L/hr, respectively.  相似文献   

7.
The objective of the study was to quantify the concentration and emission levels of sulfuric odorous compounds emitted from pig-feeding operations. Five types of pig-housing rooms were studied: gestation, farrowing, nursery, growing and fattening rooms. The concentration range of sulfuric odorous compounds in these pig-housing rooms were 30–200 ppb for hydrogen sulfide (H2S), 2.5–20 ppb for methyl mercaptan (CH3SH), 1.5–12 ppb for dimethyl sulfide (DMS; CH3SCH3) and 0.5–7 ppb for dimethyl disulfide (DMDS; CH3S2CH3), respectively. The emission rates of H2S, CH3SH, DMS and DMDS were estimated by multiplying the average concentration (mg m−3) measured near the air outlet by the mean ventilation rate (m3 h−1) and expressed either per area (mg m−2 h−1) or animal unit (AU; liveweight of the pig, 500 kg) (mg pig−1 h−1). As a result, the emission rates of H2S, CH3SH, DMS and DMDS in the pig-housing rooms were 14–64, 0.8–7.3, 0.4–3.4 and 0.2–1.9 mg m−2 h−1, respectively, based on pig's activity space and 310–723, 18–80, 9–39 and 5–22 mg AU−1 h−1, respectively, based on pig's liveweight, which indicates that their emission rates were similar, whether based upon the pig's activity space or liveweight. In conclusion, the concentrations and emission rates of H2S were highest in the fattening room followed by the growing, nursery, farrowing and gestation rooms whereas those of CH3SH, DMS and DMDS concentrations were largest in the growing room followed by the nursery, gestation and farrowing rooms.  相似文献   

8.
Individual leaves of Phaseolus vulgaris L. were exposed for 9 h in a leaf chamber to different NH3 concentrations at different light intensities. The rates of NH3-uptake, transpiration and photosynthesis were measured simultaneously. The flux density of NH3 increased linearly with concentration in the range of 4–400μg m−3. Flux densities also increased with light intensity. Resistance analysis indicated that NH3 transport into the leaf is via the stomata: transport via the cuticle is negligible under the experimental conditions. There is no internal resistance against NH3 transport. The NH3 flux was found not to influence the photosynthesis.  相似文献   

9.
Measurements of ammonia and particulate ammonium were made in the daytime (1200–1500) at a urban site in Yokohama during the 5-year period, 1982–1986. Diurnal NH3 concentrations showed a distinct seasonal trend with a maximum in summer. The diurnal monthly average concentrations were above 10 ppb during the late spring and summer months, while the concentrations during the winter months were between 1 and 5 ppb. The seasonal variation was found to be very similar to that of the average air temperature and showed a periodic pattern over 1 year. A good correlation was observed between diurnal NH3 concentrations and average air temperatures during the 5-year period. The annual mean concentrations were in the range of 6.6–7.6 ppb with only a minor deviation. The diurnal monthly average concentrations of particulate NH4+ were between 1 and 4 μg m−3 and no significant seasonal variations were seen. As a short-term study, simultaneous measurements of NH3, HNO3 and particulate NO3 were made. The diurnal mean concentrations of NH3 and HNO3 were 7.6 and 0.8 ppb, respectively. The concentration of particulate NO3 ranged from 0.3 to 6μg−3. Both HNO3 and particulate NO3 concentrations were relatively low and constant. Thus, NH3 and HNO3 levels did not agree with the concentrations predicted from the NH4NO3 equilibrium constant.  相似文献   

10.
Media depth (MD) and moisture content (MC) are two important factors that greatly influence biofilter performance. The purpose of this study was to investigate the combined effect of MC and MD on removing ammonia (NH3), hydrogen sulfide (H2S), and nitrous oxide (N2O) from swine barns. Biofiltration performance of different MDs and MCs in combination based on a mixed medium of wood chips and compost was monitored. A 3 × 3 factorial design was adopted, which included three levels of the two factors (MC: 45%, 55%, and 67% [wet basis]; MD: 0.17, 0.33, and 0.50 m). Results indicated that high MC and MD could improve NH3 removal efficiency, but increase outlet N2O concentration. When MC was 67%, the average NH3 removal efficiency of three MDs (0.17, 0.33, and, 0.50 m) ranged from 77.4% to 78.7%; the range of average H2S removal efficiency dropped from 68.1–90.0% (1–34 days of the test period) to 36.8–63.7% (35–58 days of the test period); and the average outlet N2O concentration increased by 25.5–60.1%. When MC was 55%, the average removal efficiency of NH3, H2S, and N2O for treatment with 0.33 m MD was 72.8 ± 5.9%, 70.9 ± 13.3%, and –18.9 ± 8.1%, respectively; and the average removal efficiency of NH3, H2S, and N2O for treatment with 0.50 m MD was 77.7 ± 4.2%, 65.8 ± 13.7%, and –24.5 ±12.1%, respectively. When MC was 45%, the highest average NH3 reduction efficiency among three MDs was 60.7% for 0.5 m MD, and the average N2O removal efficiency for three MDs ranged from –18.8% to –12.7%. In addition, the pressure drop of 0.33 m MD was significantly lower than that of 0.50 m MD (p < 0.05). To obtain high mitigation of NH3 and H2S and avoid elevated emission of N2O and large pressure drop, 0.33 m MD at 55% MC is recommended.

Implications: The performances of biofilters with three different media depths (0.17, 0.33, and 0.50 m) and three different media moisture contents (45%, 55%, and 67% [wet basis]) were compared to remove gases from a swine barn. Using wood chips and compost mixture as the biofilters media, the combination of 0.33 m media depth and 55% media moisture content is recommended to obtain good reduction of NH3 and H2S, and to simultaneously prevent elevated emission of N2O and large pressure drop across the media.  相似文献   


11.
Abstract

This paper introduces a predictive mechanism for elemental mercury (Hg0) oxidation on selective catalytic reduction (SCR) catalysts in coal-fired utility gas cleaning systems, given the ammonia (NH3)/nitric oxide (NO) ratio and concentrations of Hg0 and HCl at the monolith inlet, the monolith pitch and channel shape, and the SCR temperature and space velocity. A simple premise connects the established mechanism for catalytic NO reduction to the Hg0 oxidation behavior on SCRs: that hydrochloric acid (HCl) competes for surface sites with NH3 and that Hg0 contacts these chlorinated sites either from the gas phase or as a weakly adsorbed species. This mechanism explicitly accounts for the inhibition of Hg0 oxidation by NH3, so that the monolith sustains two chemically distinct regions. In the inlet region, strong NH3 adsorption minimizes the coverage of chlorinated surface sites, so NO reduction inhibits Hg0 oxidation. But once NH3 has been consumed, the Hg0 oxidation rate rapidly accelerates, even while the HCl concentration in the gas phase is uniform. Factors that shorten the length of the NO reduction region, such as smaller channel pitches and converting from square to circular channels, and factors that enhance surface chlorination, such as higher inlet HCl concentrations and lower NH3/NO ratios, promote Hg0 oxidation.

This mechanism accurately interprets the reported tendencies for greater extents of Hg0 oxidation on honeycomb monoliths with smaller channel pitches and hotter temperatures and the tendency for lower extents of Hg0 oxidation for hotter temperatures on plate monoliths. The mechanism also depicts the inhibition of Hg0 oxidation by NH3 for NH3/NO ratios from zero to 0.9. Perhaps most important for practical applications, the mechanism reproduces the reported extents of Hg0 oxidation on a single catalyst for four coals that generated HCl concentrations from 8 to 241 ppm, which covers the entire range encountered in the U.S. utility industry. Similar performance is also demonstrated for full-scale SCRs with diverse coal types and operating conditions.  相似文献   

12.
The biochar derived from rice hull was evaluated for its abilities to remove hydrogen sulfide (H2S) from gas phase. The surface area and pH of the biochar were compared. The biochar derived from rice hull was evaluated for its abilities to remove hydrogen sulfide (H2S) from gas phase. The surface area and pH of the biochar were compared. The different pyrolysis temperature has great influence on the adsorption of H2S. At the different pyrolysis temperature, the H2S removal efficiency of rice hull-derived biochar was different. The adsorption capacities of biochar were 2.09 mg·g–1, 2.65 mg·g–1, 16.30 mg·g–1, 20.80 mg·g–1, and 382.70 mg·g–1, which their pyrolysis temperatures were 100 °C, 200 °C, 300 °C, 400 °C and 500 °C respectively. Based on the Yoon-Nelson model, it analyzed the mass transfer mechanism of hydrogen sulfide adsorption by biochar.

Implications: The paper focuses on the biochar derived from rice hull–removed hydrogen sulfide (H2S) from gas phase. The surface area and pH of the biochar were compared. The different pyrolysis temperatures have great influence on the adsorption of H2S. At the different pyrolysis temperatures, the H2S removal efficiency of rice hull–derived biohar was different. The adsorption capacities of biochar were 2.09, 2.65, 16.30, 20.80, and 382.70 mg·g?1, and their pyrolysis temperatures were 100, 200, 300, 400, and 500 °C, respectively. Based on the Yoon-Nelson model, the mass transfer mechanism of hydrogen sulfide adsorption by biochar was analyzed.  相似文献   

13.
Abstract

Hydrogen sulfide (H2S) generation in construction and demolition (C&D) debris landfills has been associated with the biodegradation of gypsum drywall. Laboratory research was conducted to observe H2S generation when drywall was codisposed with different C&D debris constituents. Two experiments were conducted using simulated landfill columns. Experiment 1 consisted of various combinations of drywall, wood, and concrete to determine the impact of different waste constituents and combinations on H2S generation. Experiment 2 was designed to examine the effect of concrete on H2S generation and migration. The results indicate that decaying drywall, even alone, leached enough sulfate ions and organic matter for sulfate-reducing bacteria (SRB) to generate large H2S concentrations as high as 63,000 ppmv. The codis-posed wastes show some effect on H2S generation. At the end of experiment 1, the wood/drywall and drywall alone columns possessed H2S concentrations >40,000 ppmv. Conversely, H2S concentrations were <1 ppmv in those columns containing concrete. Concrete plays a role in decreasing H2S by increasing pH out of the range for SRB growth and by reacting with H2S. This study also showed that wood lowered H2S concentrations initially by decreasing leachate pH values. Based on the results, two possible control mechanisms to mitigate H2S generation in C&D debris landfills are suggested.  相似文献   

14.
ABSTRACT

In this study, granular activated carbon (GAC) was used as an adsorbent for biogas desulfurization. Biogas containing 932–2,350 ppm of H2S was collected from an anaerobic digester to treat the wastewater from a dairy farm with about 200 cows. An adsorption test was performed by introducing the biogas to a column that was packed with approximately 50 L of commercial GAC. The operation ceased if the effluent gas had an H2S concentration of over 100 ppm. The GAC was replaced by a given weight of new GAC in a subsequent test. According to the results, for H2S concentrations in the range of 932–1,560 ppm (average±SD = 1,260 ± 256 ppm), 1 kg of the GAC yielded biogas treatment capacities of 568 ± 112 m3 and H2S adsorption capacities of 979 ± 235 g. For the higher influent H2S concentrations of 2,110 ± 219 ppm, the biogas treatment and H2S-adsorption capacities decreased to 229 ± 18 m3 and 668 ± 47 g, respectively. An estimation indicated a requisite cost of US$16.5 for the purification of 1,000 m3 of biogas containing 2,110 ppm of H2S. This cost is approximately 5% of US$330, the value of 1,000 m3 of biogas.  相似文献   

15.
Removal of volatile sulphur compounds from livestock waste air by biological air filtration may be enhanced by application of packing materials with reactive properties. In this study, light expanded clay aggregates (Leca®) was tested with respect to sorption and potential chemical degradation of H2S, Methanethiol (MT) and Dimethyl sulphide (DMS). Leca was selected due to its content of minerals, including iron, and due to its high specific surface area. The performance of Leca was evaluated based on breakthrough curves and by comparing the difference between the inlet and outlet gas concentrations. Whereas DMS did not appear to be removed by Leca, both H2S and MT were removed with variable efficiency depending on the specific conditions. Dimethyl disulphide (DMDS) and dimethyl trisulphide (DMTS) were demonstrated to be produced during the degradation process in relatively high yields. A comparison between ambient air and nitrogen gas conditions showed that the chemisorption of H2S and MT did not necessarily need oxygen to be present. X-ray analysis of Leca showed an abundance of Fe2O3. It is therefore hypothesized that Fe2O3 in Leca can remove H2S and MT by chemisorption. Both air velocity and moisture content clearly affected the capacity of Leca for removal of H2S and MT. Lower removal is seen at higher air velocities, whereas higher moisture content enhances removal. However, chemisorption of MT by Leca appears to be limited above a threshold moisture level. Potential reaction mechanisms are discussed in relation to the observed effects. The results implicate that Leca can be used as a filter material with reactive properties provided that moisture content is controlled and that an adequate air velocity is used.  相似文献   

16.
ABSTRACT

The purpose of this research was to determine the efficiency of a polymer biocover for the abatement of H2S and NH3 emissions from an east-central Missouri swine lagoon with a total surface area of 7800 m2. The flux rate of NH3, H2S, and CH4 was monitored continuously from two adjacent, circular (d = 66 m) control and treatment plots using a nonintrusive, micrometeorological method during three independent sampling periods that ranged between 52 and 149 hr. Abatement rates were observed to undergo a temporal acclimation event in which NH3 abatement efficiency improved from 17 to 54% (p = <0.0001 to 0.0005) and H2S abatement efficiency improved from 23 to 58% (p < 0.0001) over a 3-month period. The increase in abatement efficiency for NH3 and H2S over the sampling period was correlated with the development of a stable anaerobic floc layer on the bottom surface of the biocover that reduced mass transfer of NH3 and H2S across the surface. Analysis of methanogenesis activity showed that the biocover enhanced the rate of anaerobic digestion by 25% when compared with the control. The biocover-enhanced anaerobic digestion process was shown to represent an effective mechanism to counteract the accumulation of methanogenic substrates in the biocovered lagoon.  相似文献   

17.
In order to remove high concentrations of hydrogen sulfide (H2S) gas from anaerobic wastewater treatments in livestock farming, a novel process was evaluated for H2S gas abatement involving the combination of chemical absorption and biological oxidation processes. In this study, the extensive experiments evaluating the removal efficiency, capacity, and removal characteristics of H2S gas by the chemical absorption reactor were conducted in a continuous operation. In addition, the effects of initial Fe2 + concentrations, pH, and glucose concentrations on Fe2 + oxidation by Thiobacillus ferrooxidans CP9 were also examined. The results showed that the chemical process exhibited high removal efficiencies with H2S concentrations up to 300 ppm, and nearly no acclimation time was required. The limitation of mass‐transfer was verified as the rate‐determining step in the chemical reaction through model validation. The Fe2 + production rate was clearly affected by the inlet gas concentration as well as flow rate and a prediction equation of ferrous production was established. The optimal operating conditions for the biological oxidation process were below pH 2.3 and 35°C in which more than 90% Fe3 + formation ratio was achieved. Interestingly, the optimal glucose concentration in the medium was 0.1%, which favored Fe2 + oxidation and the growth of T. ferrooxidans CP9.  相似文献   

18.
Bench-scale experiments have been conducted to evaluate a series of titania-supported Pt-Pd (as oxides) catalysts in the presence and absence of MoO3 and Fe2O3 additives for their effectiveness in the complete catalytic oxidation of volatile organic compounds (VOCs) in air likely to be found in waste gases. Under oxidizing conditions, all of the catalysts promoted the complete oxidation of VOCs to CO2 and H2O. 99 % Conversion was achieved with a C2H4-C2H6 gas mixture in air at temperatures between about 160–450 °C and at a space velocity of 20,000 h?1. Oxidation activity for the titania supported catalysts were found to decrease in the order Pt-Pd-Mo-Fe > Pt-Pd-Mo > Pt-Pd-Fe > Pt-Pd. However, the addition of MoO3 and Fe2O3 increase the catalyst activity and reduce the reaction temperature for the complete destruction. Ageing was also performed in order to study the stability of the most active catalyst. Pt-Pd-Mo-Fe (as oxides) on titania catalyst is effective in oxidizing a wide range of volatile organic compounds at relatively low temperatures (220–405 °C) and and at a space velocity of 40,000 h?1 and is resistant to poisoning by halogenated and amine volatile organic compounds.  相似文献   

19.
Waste oil fly ash (OFA) collected from disposal of power generation plants was treated by physicochemical activation technique to improve the surface properties of OFA. This synthesized material was further used for potential hydrogen sulfide (H2S) adsorption from synthetic natural gas. The raw OFA was basically modified with a mixture of acids (20% nitric acid [HNO3] and 80% phosphoric acid [H3PO4]), and it was further treated with 2 M potassium hydroxide (KOH) to enhance the surface affinity as well as surface area of synthesized activated carbon. Correspondingly, it enhanced the adsorption of H2S. Crystallinity, surface morphology, and pore volume distribution of prepared activated carbon were investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM), and Brunauer-Emmett-Teller (BET) analyses. Fourier transform infrared (FTIR) study was also performed to identify the functional groups during different synthesis stages of modified activated carbon. The Langmuir, Freundlich, Sips, and dual-site Langmuir (DSL) models were used to study the kinetic and breakthrough behavior of H2S adsorption over alkali-modified activated carbon. Modeling results of isotherms indicated that OFA has dual sites with high and low affinity for H2S adsorption. The Clark model, Thomas model, and Yoon-Nelson model were used to examine the effects of flow rate and inlet concentration on the adsorption of H2S. Maximum uptake capacity of 8.5 mg/g was achieved at 100 ppm inlet concentration and flow rate of 0.2 L/min.

Implications: Utilization of worthless oil fly ash from power plant is important not only for cleaning the environment but also for solid waste minimization. This research scope is to eradicate one pollutant by using another pollutant (waste ash) as a raw material. Chemical functionalization of synthesized activated carbon from oil fly ash would lead to attachment of functional groups of basic nature to attract the acidic H2S. Such type of treatment can enhance the uptake capacity of sorbent several times.  相似文献   


20.
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods of at least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0 ± 1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.

Implications: Passive samplers are very attractive tools to experimentally tackle a number of air pollution problems, especially those related to odor impact. Their small size and cost permit a denser sampling design and thus a more detailed spatial characterization than other techniques. On the other hand, the large inherent variability in passive sampler measures requires an uncertainty analysis of the chemical species and analytical procedures used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号