首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The value of measuring the separate sub-units of human chorionic gonadotrophin (free α-hCG and free β-hCG) instead of total hCG together with alpha-fetoprotein (AFP) and unconjugated oestriol (uE3) was examined to determine the effect on the performance of serum screening for Down's syndrome between 15 and 22 weeks of pregnancy. The study was based on stored serum samples relating to 75 singleton pregnancies with fetal Down's syndrome and 367 unaffected singleton pregnancies, matched for maternal age, gestational age, and duration of storage of the serum sample, supplemented by data from 970 white women with unaffected pregnancies. Using the four serum markers AFP, uE3, free β-hCG, and free α-hCG, in addition to maternal age, 65 per cent of Down's syndrome pregnancies were detected for a 5 per cent false-positive rate compared with 59 per cent with the conventional triple test (AFP, uE3, total hCG with maternal age). If gestation was based on an ultrasound scan examination, the detection rate was 72 per cent using the four serum markers compared with 67 per cent with the triple test. As an alternative illustration, if the detection rate was kept at 60 per cent and gestation was estimated by an ultrasound scan examination the four-marker test reduced the false-positive rate by one-third from 3 per cent using the triple test to 2 per cent with the four-marker test. Screening performance was hardly affected by adjusting marker levels for maternal weight. The four-marker test is, both from a medical and from a financial perspective, the most effective method of prenatal screening for Down's syndrome suitable for routine use.  相似文献   

2.
The effect of repeat testing in maternal serum multiple marker screening for Down's syndrome was estimated using samples stored in an antenatal serum bank. Human chorionic gonadotropin (hCG) and unconjugated oestriol (uE3) levels were determined in 142 pairs of routinely collected samples which had already been tested for alpha-fetoprotein (AFP). For each marker, about two-thirds of the pairs of values were within 20 per cent of each other and most were within 40 per cent. A multivariate Gaussian model was used to estimate the detection and false-positive rates for different repeat testing policies. A policy of repeat testing those with a high risk of a Down's syndrome term pregnancy given age and marker levels would reduce the false-positive rate but there would also be a reduction in the detection rate. For example, using all three markers and a 1 in 250 cut-off risk, the estimated false-positive rate would fall from 5·3 to 3·8 per cent but the detection rate would decrease from 58 to 55 per cent. A policy of repeating those with either high or borderline risks would produce a modest improvement in screening efficiency. Repeating the 11 per cent with a risk exceeding 1 in 500 yields an estimated false-positive rate of 5·0 per cent and a detection rate of 60 per cent. A policy of selective repeat testing is not recommended as it would not substantially improve screening efficiency. Nonetheless, if a repeat test has been performed, the parameters given in this paper will enable an unbiased estimate of the Down's syndrome risk to be calculated for individual women.  相似文献   

3.
Over a 2-year period from January 1991 to December 1992, second-trimester maternal serum screening for Down's syndrome using alpha-fetoprotein (aFP), human chorionic gonadotrophin (hCG), and unconjugated oestriol (uE3) was made available to five health districts in East Anglia, with a total population of 1·2 million. Amniocentesis was offered when the risk of Down's syndrome at term was 1:200 or greater. 25359 singleton pregnancies were screened, representing an uptake of 77 per cent. The recall rate for the 24 per cent of women who had not had a dating scan prior to the test was 9·4 per cent compared with 3·9 per cent for those who had been scanned (P<0·0005). Seventy-five per cent (36/48) of Down's syndrome pregnancies were detected for a false-positive rate of 4·0 per cent. Twenty-five out of 36 of detected Down's syndrome pregnancies were dated by scan prior to sampling, and in the 11 remaining cases, the dates were confirmed by scan after a high-risk result was obtained. The exclusion of uE3 from the screening protocol would have reduced the detection rate to 52 per cent (25/48) for the same false-positive rate. Eighty-five per cent of women identified at high risk accepted the offer of an amniocentesis. Other fetal abnormalities detected were trisomy 18 (3), trisomy 13 (2), 45,X (6), 69,XXX (5), other chromosome abnormalities (9), open neural tube defects (26), hydrocephalus (7), abdominal wall defects (4), and steroid sulphatase deficiency (6).  相似文献   

4.
Human chorionic gonadotrophin (hCG) levels were assayed retrospectively in stored maternal serum samples from 78 chromosomally abnormal pregnancies and 410 controls matched for gestation and maternal age. The median serum hCG concentration in 49 pregnancies with Down's syndrome was significantly elevated, at 2.18 multiples of the normal median. Significantly reduced hCG concentrations were found in a group of four trisomy 18 pregnancies (all less than 0.4 multiples of the median). Eight cases of unbalanced chromosome rearrangements appeared to show some lowering of hCG levels, while there was no significant difference in the levels in the cases of trisomy 13, balanced translocations, and sex chromosome abnormalities. Maternal serum hCG alone is a better indicator of Down's syndrome pregnancies than maternal age or maternal serum alpha-fetoprotein (AFP), either individually or in combination, and provides a further virtually independent measure of risk. On the basis of our findings, screening for Down's syndrome using hCG and AFP results combined with maternal age risks is predicted to result in a higher detection rate (57 per cent) for a lower false-positive rate (5.0 per cent) than would be attainable by combined AFP and age screening (37 per cent detection at a 6.6 per cent false-positive rate).  相似文献   

5.
To determine the effect of routine repeat testing in serum screening for Down's syndrome, we compared estimates of the detection and false-positive rates. Five serum markers were measured-alpha-fetoprotein (AFP), unconjugated oestriol (uE3), human chorionic gonadotrophin (hCG), and its two subunits, free α and free β-hCG. First and repeat test marker levels were available from 142 women whose samples had been routinely collected and stored in an antenatal serum bank. Different repeat testing policies were compared for various combinations of the markers. If all women had repeat tests using the four markers AFP, uE3, and free α and free β-hCG, the detection rate for a 5 per cent false-positive rate was 69 per cent compared with 65 per cent if no women were repeated. Policies of repeating selected women gave similar results. The small gain in screening performance with repeat testing performed routinely is not worthwhile. If a woman does happen to have a repeat test, her risk estimate should, however, be based on both results, not just the second.  相似文献   

6.
A new method is described for calculating maternal serum marker distribution parameters which will improve risk estimation when screening for Down's syndrome. The approach is to calculate parameters using data from the local screened population and data obtained by meta-analysis from all published studies. The local data are used to derive the variance and covariance in unaffected pregnancies. The meta-analysis is used for the mean level in Down's syndrome pregnancies together with the differences in variance and covariance between affected and unaffected pregnancies. Forty-four published studies were analysed. The mean level for Down's syndrome in multiples of the normal median was 0·73 for alpha-fetoprotein (AFP) in total of 1140 pregnancies, 0·73 for unconjugated oestriol (uE3) in 613, 2·02 for human chorionic gonadotropin (hCG) in 850, and 2·30 for free β-hCG in 477. For all four markers, the variance in Down's syndrome was higher than in unaffected pregnancies; for AFP and uE3, the covariances were also higher in Down's syndrome, but for the other markers they were lower. The method was illustrated using data from 6387 pregnancies screened in Leeds.  相似文献   

7.
The effectiveness and costs of prenatal screening programmes for Down's syndrome using maternal serum markers will vary significantly depending on the biological cut-off values chosen in order to select women, at each maternal age, who will be sent for amniocentesis. On the basis of the first French prospective study of human chorionic gonadotropin (hCG) measurement in maternal serum, this paper shows that the screening protocol currently used in France, where hCG cut-off values are defined in order to offer amniocentesis to women of all ages with a 1 percent fetal risk of Down's syndrome, would detect 64·06 per cent of all cases of trisomy 21 at birth and would be highly profitable for the French social security system. On the basis of a representative sample of 100 000 pregnant women, the total costs of screening would reach $8 302 000 but would generate net potential savings of $32 186 000 in terms of life-long costs of care for trisomic 21 children which would be ‘avoided’ by termination of pregnancy following a positive diagnosis of Down's syndrome. Economic assessment shows that cost-benefit analysis would justify lower hCG cut-off values and a higher detection rate of fetal Down's syndrome (74·45 per cent) than the current French protocol. This paper concludes that it is ethical and value-laden issues, such as the consequences for women and couples of false positives and false negatives of screening, rather than economic and financial arguments that may set limits to the utilization of screening for Down's syndrome using maternal serum markers like hCG.  相似文献   

8.
Second-trimester distributions of the free beta human chorionic gonadotrophin (hCG) and alpha-fetoprotein (AFP) levels in 420 twin and 19 triplet pregnancies were measured and compared with the distributions in 6661 singleton pregnancies. On average, the levels of both analytes were twice as high in twins and over three times as high in triplets. Eight sets of twins discordant for Down's syndrome showed elevated levels of free beta hCG and reduced levels of AFP after correction of the multiple of the median for the presence of a twin pregnancy. Screening for Down's syndrome using the twin correction of the multiple of the median is expected to achieve a 51 per cent detection rate at a 5 per cent false-positive rate using these two markers.  相似文献   

9.
The levels of the maternal serum markers alpha-fetoprotein (AFP), human chorionic gonadotrophin (hCG), and unconjugated oestriol (uE3) in 35 pregnant women with early second-trimester oligohydramnios differed from those in a reference population of 1699 singleton pregnancies. Maternal serum AFP levels above the 95th centile of the population distribution were observed in 80 per cent (16/20) of oligohydramnios cases with a normal fetus and in only 20 per cent (3/15) of the cases with a fetus displaying urogenital tract malformations. Elevated levels of hCG (above the 95th centile) and decreased levels of uE3 (below the fifth centile) were encountered in 26 per cent (9/35) and 17 per cent (6/35) of the women, irrespective of the fetal condition. The abnormal profile of the serum markers in early second-trimester oligohydramnios resulted in 57 per cent (20 out of 35) of screen-positive cases for either fetal Down's syndrome or neural tube defects, compared with 8·4 per cent (143 out of 1699) in the reference population.  相似文献   

10.
The aim of this study was to determine the maternal population, pregnancy, serum alpha-fetoprotein (AFP) and free β subunit of human chorionic gonadotrophin (FβhCG) parameters in a large series of women attending prenatal clinics before 15 weeks' gestation and to assess the practical problems of population screening for Down's syndrome in the first trimester using these markers. Serum samples were collected from 8600 women attending prenatal clinic booking visits. Maternal serum AFP and FβhCG medians were calculated for each day of gestation (49–104 days), using both dates and ultrasound estimates of gestation. The effects of maternal weight, twin pregnancies, and threatened abortion on AFP and FβhCG levels were analysed. The median age of the population was 27.1 years and the median weight 62.1 kg. Twenty-six per cent of samples were collected before 70 days and 50 per cent before 78 days' gestation. Eighty-nine per cent of all samples had gestational estimates by dates, 60 per cent by ultrasound and 52 per cent by both dates and ultrasound. The AFP median was 5 kU/1 at 49 days, 5.9 kU/1 at 70 days, and 17.9 kU/1 at 100 days. The peak median FβhCG level was 66.4 ng/ml at 64 days, falling to 20.6 ng/ml at 100 days' gestation. Both AFP and FβhCG levels showed log Gaussian distributions but the standard deviation for AFP was 20 per cent greater than that found in the second trimester. AFP and FβhCG levels showed an inverse relationship with maternal weight and were increased in twin pregnancies (1.68 and 1.97 multiples of the median, respectively). AFP and FβhCG can be readily measured in a large screening population in the first trimester. Down's syndrome screening protocols based on these markers could be refined by the use of gestations in individual days but AFP is likely to be a less effective marker and detection rates are likely to be lower than in the second trimester. To realize the potential of first-trimester screening, more women should be encouraged to attend the prenatal clinic in early pregnancy and ultrasound dating should be carried out for all pregnancies at this stage.  相似文献   

11.
Risks appropriate for mid-trimester prenatal screening for autosomal trisomies have been estimated from a combination of maternal age and maternal serum (MS) alpha-fetoprotein (AFP) levels at 16–20 weeks gestation. Published data on the frequency of Down's syndrome births relative to maternal age were modified to include the additional age-related frequency of trisomy 18 and trisomy 13 cases to provide an overall risk for an autosomal trisomy at midtrimester. MSAFP results from a retrospective study of 142 affected (114 trisomy 21, 19 trisomy 18, and 9 trisomy 13)and 113 000 unaffected pregnancies were converted to multiples of the appropriate gestational median (MOM). The AFP levels in the autosomal trisomy pregnancies were found to be significantly reduced at 0.72 MOM of the unaffected pregnancies. Risks (likelihood ratios) were derived from the overlapping log Gaussian distributions for affected and unaffected pregnancies and combined with maternal age risks to give the overall odds of an affected pregnancy. A mid-trimester cut-off risk of 1:280 gave an estimated 37 per cent detection rate for autosomal trisomies in the west of Scotland population for a follow-up (false-positive) rate of 6.6 per cent. These figures compare with a 30 per cent detection and 6.7 per cent false-positive rate if age 35 years and over is used as the sole criterion for selection of at-risk pregnancies.  相似文献   

12.
While second-trimester prenatal screening programmes for Down's syndrome have become established in prenatal care, it would be advantageous to be able to offer screening in earlier preganancy. To this end, we have evaluated a new potential maternal serum marker, dimeric inhibin A, as a possible first-trimester marker. Dimeric inhibin A was measured in propsectively collected maternal serum from 23 cases of Down's syndrome and matched chromosomally normal controls, at 11–13 weeks' gestation. Levels of this protein were significantly elevated in the Down's pregnancies compared with the control pregnancies. The median multiple of the normal median (MOM) for the Down's samples was 2.46 (95 per cent confidence interval: 2.11–3.26, P<0.0001 vs. controls). These results suggest that dimeric inhibin A is a useful discriminator of Down's-affected pregnancies from normal pregnancies in the first trimester and that sensitive screening in combination with maternal age and other possible markers may be practicable in the first trimester.  相似文献   

13.
We have examined the possibility of using multiple markers in maternal urine rather than serum in order to screen for Down's syndrome. Urine samples were available from 36 cases (24 Down's syndrome, five Edwards' syndrome, three Turner's syndrome, one Klinefelter's syndrome, one triploidy, one triple-X, one twin discordant for Down's syndrome) and 294 controls, including three twins. Three markers were tested: the β-core fragment of human chorionic gonadotrophin (hCG), total oestrogen (tE) and the free a subunit of hCG. Levels were corrected for creatinine excretion and expressed as multiples of the gestation-specific median (MOM) level from the singleton controls. The median value for the singleton Down's syndrome cases was 6.02, 0.74, and 1.08 MOM for β-core-hCG, tE, and a-hCG, respectively. The increases in β-core-hCG and the reduction in tE levels were highly significant (P<0.0001 and 0.005, respectively; Wilcoxon rank sum test) but the increase in free a-hCG was not (P=0.40). On the basis of a mathematical model, the expected detection rate for a 5 per cent false-positive rate was 79.6 per cent for β-core-hCG alone, which increased to 82.3 per cent when combined with tE. Aneuploidies other than Down's syndrome were characterized by low levels of tE and either low or high β-core-hCG.  相似文献   

14.
A prenatal screening programme for Down's syndrome potentially detecting 76 per cent of affected pregnancies in the South Australian general population at an amniocentesis rate of 3.9 per cent was designed following analysis of mid-trimester serum samples from 57 women who carried an affected fetus. This equates to one affected pregnancy being detected for 41 chromosomal analyses performed. For the experimental series, 75.4 per cent of affected pregnancies were detected, while 4.1 per cent of control specimens produced estimated risk odds consistent with further action. A maternal risk odds of birth of a Down's syndrome fetus of 1:420 was taken as the decision value, which is the prevalence of Down's syndrome births to 35-year-old mothers in South Australia. This screening performance was achieved by investigating combinations of serum analytes not previously reported and by refining the calculation of maternal risk odds to include selective weighting of indicator analytes. Combination of the measurements of free α-subunits and β-subunits of chorionic gonadotrophin, α-fetoprotein, unconjugated oestriol, and placental lactogen was found to be most effective in indicating Down's syndrome fetuses. In all combinations of analytes tested, replacing the measurements of free α-subunits and free β-subunits of chorionic gonadotrophin with the measurement of intact chorionic gonadotropin produced a less effective screen.  相似文献   

15.
The median maternal serum free beta human chorionic gonadotropin (hCG) multiple of the median (MOM) of 480 Down syndrome cases in the second trimester was 2·64, significantly greater than the reported median MOM of intact hCG (p<0·0001). In 234 of these cases from retrospective and prospective studies, the effectiveness of maternal serum free beta hCG was evaluated in combination with alpha-fetoprotein (AFP) and maternal age in second-trimester Down syndrome screening. Down syndrome detection in the gestational age range of 14–16 weeks was 82 per cent. In all gestational weeks (14–22), a 77·7 per cent Down syndrome detection rate was achieved. In prospective screening of 44 272 patients under the age of 35 years, 69 per cent of Down syndrome cases were detected (73 per cent in gestational weeks 14–16). The false-positive rate for the prospective study was 3·8 per cent. The use of free beta hCG combined with maternal serum AFP and maternal age-related risk for Down syndrome in a screening population (i.e., women under 35 years) yields an improved detection efficiency over other protocols.  相似文献   

16.
The relative effectiveness of cytogenetic prenatal diagnosis in the Mersey Region and North Wales is presented by estimating the percentage detection rates of Down's syndrome annually following amniocentesis from 1978–1984 inclusive. Tables indicating the percentage of screened pregnancies, types of chromosomal aberrations detected and the occurrence of Down's syndrome in mothers in age groups of five-year intervals are also presented. The average prenatal detection rate for Down's syndrome (estimated at the time of birth) was 15–15 per cent over the years 1978–1984 and was above 22 per cent for the last two years when 44–13 per cent of all pregnancies to mothers of 35 years and over were investigated.  相似文献   

17.
Total human chorionic gonadotropin (hCG) levels have been shown in one previous small study to vary with gravidity. In order to establish if maternal serum free beta hCG was similarly affected, approximately 4500 pregnancies of varying gravidity were analysed. The results indicated that there was a 6 per cent higher median MOM in primigravid compared with multigravid women. The impact of such elevation in Down's syndrome screening programmes will be minimal.  相似文献   

18.
We measured immunoreactive inhibin in the maternal serum of 80 pregnancies with a chromosomally normal fetus and ten Down's syndrome pregnancies in the second trimester. The inhibin level in all Down's syndrome pregnancies was above the normal median; the multiple of the normal median (MoM) was 1.9. We found a statistically significant difference between the levels of inhibin in unaffected and affected pregnancies (Kolmogorov–Smirnov test: p <0.002). Using an arbitrarily chosen cut-off of 2.4 MoM, 40 per cent of Down's syndrome and 5 per cent of the normal pregnancies were found. We conclude that immunoreactive inhibin may be useful as a marker for fetal Down's syndrome.  相似文献   

19.
Human chorionic gonadotrophin (hCG) is the most discriminatory maternal serum marker of Down's syndrome. We have carried out a study to establish whether urinary β-core-hCG, a major metabolic product of hCG, might be an even better marker. Urine samples were available from seven singleton pregnancies with Down's syndrome, and one each of Edwards' syndrome, triploidy, and twins discordant for Down's syndrome. β-Core-hCG levels were corrected for creatinine and expressed as multiples of the normal gestation-specific median (MOM) level derived from 67 singleton controls. There was a highly statistically significant elevation in level among the singleton Down's syndrome cases (P<0·0005; Wilcoxon rank sum test). All had levels exceeding 2 MOM with a median of 6·11 MOM (95 per cent confidence interval 3·7–10·0). The levels were extremely low in Edwards' syndrome (0·08 MOM) and triploidy (0·02 MOM), but the twin pregnancy discordant for Down's syndrome did not have a raised β-core-hCG level (0·64 MOM). The findings are sufficiently encouraging to investigate the possibility of urinalysis as a routine modality in the prenatal screening for Down's syndrome and other common serious aneuploidies.  相似文献   

20.
Two series of pregnancies were studied to investigate the relationship between maternal smoking and the risk of fetal Down' s syndrome. In the first series, ascertained in the 1960s, in which smoking habits were determined after the outcome of pregnancy was known, the proportion of smokers (47 per cent) among the 461 women whose pregnancies ended in the birth of an infant with Down' s syndrome was similar to that in the 461 controls (46 per cent) who had pregnancies affected by other congenital disorders. In the second series, ascertained between 1973 and 1984, smoking habits were determined by measurement of cotinine in antenatal serum samples that were routinely collected and stored or, if a serum sample was not available, from information in the antenatal notes. In this series, the proportion of smokers (14 per cent) among the 91 women who had pregnancies associated with Down' s syndrome was lower than that among 413 controls (19 per cent), though this was not statistically significant. Collectively, our results provide no evidence for an association between fetal Down' s syndrome and smoking. Other published studies found a deficit of smokers among women who had pregnancies associated with Down' s syndrome. This may be partly due to some studies not taking adequate account of maternal age (older women are more likely to have had a Down' s syndrome pregnancy but are less likely to be smokers) and partly due to the greater tendency for positive findings to be published than negative ones.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号