首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A case of aortic atresia with insufficiency of mitral valve diagnosed prenatally at 33 weeks of gestation is presented. An accurate diagnosis of this fetal cardiovascular malformation was possible by application of Doppler colour flow mapping, which demonstrated (a) the absence of forward flow in the hypoplastic ascending aorta, (b) reverse flow of blood from the ductus arteriosus into the severely hypoplastic ascending aorta in the late systole, (c) pansystolic mitral valve regurgitation, and (d) absent flow across the foramen ovale as a result of premature closure of the foramen ovale.  相似文献   

2.
Effective screening for major aneuploidies can be provided in the first trimester of pregnancy. Screening by a combination of fetal nuchal translucency and maternal serum free-β-human chorionic gonadotrophin and pregnancy-associated plasma protein-A can identify about 90% of fetuses with trisomy 21 and other major aneuploidies for a false-positive rate of 5%. Improvement in the performance of first-trimester screening can be achieved by firstly, inclusion in the ultrasound examination assessment of the nasal bone and flow in the ductus venosus, hepatic artery and across the tricuspid valve, and secondly, carrying out the biochemical test at 9 to 10 weeks and the ultrasound scan at 12 weeks. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
In this overview the current knowledge of the relationship between an increased nuchal translucency (NT) measurement and fetal heart structure and function in chromosomally normal fetuses is reviewed. Relevant pathophysiological theories behind the increased NT are discussed. Fetuses with an increased NT have an increased risk for congenital heart disease (CHD) with no particular bias for one form of CHD over another. This risk increases with increasing NT measurement. Although the NT measurement is only a modestly effective screening tool for all CHD when used alone, it may indeed be effective in identifying specific CHD “likely to benefit” from prenatal diagnosis. The combination of an increased NT, tricuspid regurgitation and an abnormal ductus venosus (DV) Doppler flow profile, is a strong marker for CHD. A fetal echocardiogram should be performed at 20 weeks' gestation in fetuses with an NT ≥ 95th percentile but < 99th percentile. When the NT measurement is ≥ 99th percentile, or when tricuspid regurgitation and/or an abnormal DV flow pattern is found along with the increased NT, an earlier echocardiogram is indicated, followed by a repeat scan at around 20 weeks' gestation. The resultant increased demand for early fetal echocardiography and sonographers with this special expertise needs to be planned and provided for. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
We report on the ultrasound features and natural history of trisomy 10. At 12 weeks' gestation in a routine scan examination, the fetus presented with increased nuchal translucency thickness, mild skin oedema, bilateral pleural effusion, marked micrognathia, cardiomegaly, unilateral talipes and reversed A-wave in the ductus venosus blood flow. Karyotyping on chorionic villus sampling (CVS) led to the diagnosis of trisomy 10, which was confirmed by fetal blood sampling at 22 weeks' gestation. As the parents opted to continue with the pregnancy, the natural history and following ultrasound features are described. This is the third case of trisomy 10 in the literature reporting on the physical features. The most frequent ultrasound findings presented in trisomy 10 are increased nuchal translucency, micrognathia, renal agenesis, facial cleft, limbabnormalities, cardiac defects and early severe growth retardation. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Assessment of the fetal cerebral circulation provides important information on the hemodynamic changes associated with chronic hypoxia and intrauterine growth restriction. Despite the incorporation of new US parameters, the landmark for the fetal brain hemodynamic evaluation is still the middle cerebral artery. However, new vascular territories, such as the anterior and posterior cerebral arteries, might provide additional information on the onset of the brain sparing effect. The fractional moving blood volume estimation and three-dimensional power Doppler ultrasound indices are new techniques that seem to be promising in indentifying cases at earlier stages of vascular deterioration; still, they are not available for clinical application and more information is needed on the reproducibility and advantages of three-dimensional power Doppler ultrasound blood flow indices. In the past, the brain sparing effect was considered as a protective mechanism; however, recent information challenges this concept. There is growing evidence of an association between brain sparing effect and increased risk of abnormal neurodevelopment after birth. Even in mild late-onset intrauterine growth restriction affected fetuses with normal umbilical artery blood flow, increased cerebral blood perfusion can be associated with a substantial risk of abnormal neuroadaptation and neurodevelopment during childhood. © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Doppler flow velocity waveform recording in the fetal ductus venosus and umbilical artery as well as maternal blood sampling for serum alpha-fetoprotein (MSAFP) was performed before and after transabdominal chorion villus sampling (TACVS) in 36 women of advanced maternal age (≥ 36 years). Gestational age ranged between 11 and 13 weeks. No chromosomal anomaly was detected. No statistically significant difference was observed in ductus venosus velocity parameters or in the umbilical artery pulsatility index (PI) before and after CVS in 35 women with a normal pregnancy outcome. One case resulted in fetal loss. Post-CVS median MSAFP levels at 12 weeks (25 kIU/1) and 13 weeks (35 kIU/1) were significantly higher than pre-CVS levels. In three cases, post-CVS MSAFP levels were higher than 600 kIU/1, correlating with feto-maternal transfusions of approximately 1.0–1.4 ml, i.e., of around 40 per cent of feto-placental blood volume. One of these cases displayed absence of fetal peripheral blood flow velocities and fetal bradycardia following TACVS, resulting in fetal loss 1 week later. The remaining two cases had a normal pregnancy outcome, but showed a more than 50 per cent reduction in ductus venosus velocity after TACVS, whereas umbilical artery PI remained unchanged. However, similar velocity changes were associated with only small feto-maternal transfusions. Umbilical artery PI values remained unchanged.  相似文献   

7.
First trimester sonographic markers are the only markers achieving detection rates above 50% in the prenatal detection of fetal aneuploidy. Although potentially they are the best markers, some concerns have arisen about its clinical application. Pitfalls may be due to inability to examine the markers, incorrect assessment, or incorrect interpretation of the findings. Markers may be unable to be examined due to maternal (maternal body habitus, previous surgery) or fetal reasons (incompatible fetal position or fetal movements). Causes of incorrect interpretation may be insufficient image magnification, incorrect caliper placement (nuchal translucency), incorrect insonation angle (nasal bone), venous contamination (ductus venosus), or arterial contamination (tricuspid regurgitation), among others. Venous contamination in ductus venosus waveforms may mimic an abnormal blood flow when it is normal, and the opposite can also occur. Finally, incorrect interpretation of a substantially increased nuchal translucency may lead to a false impression of an ominous fetal prognosis or may be confounded with a cystic hygroma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
Fetal cardiac function is increasingly recognized as a marker of disease severity and prognosis in selected fetal conditions. Magnetic resonance imaging (MRI) has been used in experimental (animal) fetal cardiology but the lack of a noninvasive fetal electrocardiogram (ECG) to trigger image acquisition remains a major limiting factor precluding its application in humans. Fetal medicine specialists are therefore limited to ultrasound to evaluate human fetal cardiac function. In this review, we aim to provide a complete overview of the different ultrasound techniques that can be used for fetal cardiac function assessment and we discuss their (theoretical) strengths and shortcomings. Conventional methods include M-mode assessment of ventricular contractility and Doppler assessment of the precordial veins and cardiac output (CO). More recent techniques such as the measurement of the myocardial performance index (MPI), myocardial motion analysis with tissue Doppler, speckle tracking and three-dimensional (3D) ultrasound techniques are also discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Colour Doppler flow mapping of the renal arteries and subsequent pulsed Doppler measurement of impedance to flow in these vessels were attempted in 33 fetuses with postnatally confirmed renal pathology. The majority presented with unilateral or bilateral hydronephro-sis (n = 21) and bilateral renal agenesis (n = 8). Renal artery blood flow could be visualized in all, except for the eight cases of bilateral renal agenesis. Bilateral flow velocity recordings were collected in six out of 12 cases of bilateral hydronephrosis and in five out of nine cases of unilateral hydronephrosis. The pulsatility index (PI), as a measure of downstream impedance, was in the normal range in 16 out of 18 kidneys (88 per cent) in bilateral hydronephrosis and in 12 out of 14 kidneys (85 per cent) in unilateral hydronephrosis. The PI was significantly higher in severe hydronephrosis compared with mild hydronephrosis. In four cases of unilateral multicystic kidney, the PI was always higher on the affected side. Colour Doppler flow mapping and pulsed Doppler evaluation may be helpful in our understanding of renal vascularization in renal pathology and in confirming the diagnosis of renal agenesis.  相似文献   

10.
Accumulating data on the human fetal circulation shows the similarity to the experimental animal physiology, but with important differences. The human fetus seems to circulate less blood through the placenta, shunt less through the ductus venosus and foramen ovale, but direct more blood through the lungs than the fetal sheep. However, there are substantial individual variations and the pattern changes with gestational age. The normalised umbilical blood flow decreases with gestational age, and, at 28 to 32 weeks, a new level of development seems to be reached. At this stage, the shunting through the ductus venosus and the foramen ovale reaches a minimum, and the flow through the lungs a maximum. The ductus venosus and foramen ovale are functionally closely related and represent an important distributional unit for the venous return. The left portal branch represents a venous watershed, and, similarly, the isthmus aorta an arterial watershed. Thus, the fetal central circulation is a very flexible and adaptive circulatory system. The responses to increased afterload, hypoxaemia and acidaemia in the human fetus are equivalent to those found in animal studies: increased ductus venosus and foramen ovale shunting, increased impedance in the lungs, reduced impedance in the brain, increasingly reversed flow in the aortic isthmus and a more prominent coronary blood flow. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

11.
A prenatal diagnosis of right atrial isomerism is often inferred through the recognition of a constellation of cardiac anomalies on the four-chamber view or by the detection of visceral heterotaxy and asplenia. However, the actual occurrence of discordance between the arrangement of the atria and thoracic and abdominal organs makes the identification of the morphology of both atrial appendages the only reliable way to make a final diagnosis of atrial isomerism. Three cases of right atrial isomerism with visceral heterotaxy and a complex cardiac defect, diagnosed in utero by cross-sectional and colour flow Doppler echocardiography, are reported. In all the patients, the right atrial isomerism was associated with an atrioventricular septal defect, a single aortic outlet from the right ventricle, and total anomalous venous return. The diagnosis of right atrial isomerism, always confirmed by neonatal re-evaluation and/or by post-mortem examination, was made through identifying two pyramidal atrial appendages in an echocardiographic transverse plane at the level of the atria and of the origin of the great arteries. This report demonstrates that a final intrauterine diagnosis of atrial isomerism is possible, whatever the visceral situs is.  相似文献   

12.
We report a case of fetal hydrocephalus secondary to a third ventricle choroid plexus papilloma detected by ultrasound at 33 weeks' gestation. The prenatal sonographic and colour flow Doppler findings of this rare fetal intracranial tumour are discussed.  相似文献   

13.
Experience with three prenatally diagnosed pregnancies complicated by an acardiac twin reveals that ultrasonography and echocardiography are helpful in detecting early signs of in-utero congestive heart failure in the normal twin. The use of Doppler blood flow analysis to determine direction of blood flow, post-mortem placental and fetal angiography, and umbilical cord blood gas determination provided proof that retrograde arterial perfusion occurs in the acardiac fetus. In a fourth pregnancy, an experimental approach to occlude the acardiac twin's umbilical cord was attempted, but was unsuccessful.  相似文献   

14.
One hundred and fifty fetuses between 16 and 38 weeks of gestation were studied by fetal echocardiography using colour-coded two-dimensional Doppler echocardiography. Two-dimensional, M-mode, and Doppler spectral analyses were also performed. In 14 fetuses, structural and/or functional abnormalities were detected. Abnormalities were correctly ruled out in all the other fetuses. The advantages of two-dimensional Doppler echocardiography are (1) rapid screening for flow abnormalities in the fetal heart, and thus shortening of the Doppler examination time; (2) rapid diagnosis of valvular regurgitation, valvular stenosis, and abnormal shunting of blood across the interatrial and interventricular septa; and (3) facilitation of the diagnosis of complex congenital heart defects which in certain cases is possible only by using two-dimensional Doppler echocardiography.  相似文献   

15.
A possible association of limb reduction defects with chorionic villus sampling (CVS) may be related to compromised umbilical blood flow from the trauma of the procedure. We hypothesized that because CVS may disrupt or compromise umbilical blood flow to the fetus, either by vasoconstriction, bradycardia, or emboli, we would detect these changes using Doppler velocimetry. A cohort of 21 consecutive consenting patients undergoing first-trimester elective CVS for prenatal diagnosis were entered into a prospective longitudinal study. Colour flow Doppler velocimetry was performed on fetal umbilical arterial blood flow immediately before and after CVS to measure the pulsatility index, fetal heart rate, per cent flow time, and maximum flow velocity. Measurements were obtained from three consecutive cardiac cycles in three different umbilical segments and averaged. Potentially confounding variables also recorded included gestational age, method of CVS, number of passes, number of aspirations, placental location, tissue sample size, and operator. Umbilical velocimetry values before and after CVS were compared using the paired t-test and showed no statistically significant differences. No differences were found when data were analysed by gestational age, sample size, method, number of aspirations, placental location, or operator. We were unable to detect any significant change in fetal umbilical arterial blood flow velocimetry or heart rate after performing CVS. Umbilical blood flow does not appear to be routinely compromised by CVS.  相似文献   

16.
The objective of this study was to evaluate the effect of fetal blood sampling on cardiac flow velocity waveforms. Flow velocity waveforms were measured from the ascending aorta and pulmonary artery immediately before and after fetal blood sampling in 29 normally grown and 12 growth-retarded fetuses. The latter group was characterized by abnormal Doppler indices in the umbilical artery and middle cerebral artery suggestive of uteroplacental insufficiency as the causative factor of the impaired growth. The flow velocity parameters studied were the peak velocity, the time to peak velocity, and the left and right cardiac output and their ratio. In normally grown fetuses, the peak velocity and right and left cardiac output values increased significantly after fetal blood sampling, while no significant changes were observed in the other indices considered. The gestational age at the time of the procedure was positively related to the amplitude of these changes. In growth-retarded fetuses, fetal blood sampling did not induce any significant increase in cardiac output or peak velocities, while in more than 50 per cent of the fetuses these Doppler indices decreased. The amplitude of the decrease was significantly related to the severity of acidosis in the umbilical vein. In conclusion, the cardiac haemodynamic response to fetal blood sampling differs between normally grown and growth-retarded fetuses. This difference may explain the higher rate of complications occurring in the latter group of fetuses after blood sampling.  相似文献   

17.
The ductus venosus (DV) is a tiny vessel leading oxygenated blood from the placenta to the fetal heart and its flow assessment has been used as an indicator of fetal acidemia. At 11 to 14 weeks, the fetuses with increased nuchal translucency also showing an abnormal DV blood flow were consistently found to be aneuploid. Early cardiac dysfunction, signaled by abnormal DV blood flow, was suggested as the underlying cause of increased nuchal translucency. Detection rates for aneuploidy with the use of DV blood flow studies range from 59 to 93% with 2 to 21% false-positive rates. In fetuses with normal karyotype, an abnormal DV flow pattern signals cardiac defects or adverse perinatal outcome. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
Rapid advances in graphics computing and micro-engineering have offered new techniques for prenatal cardiac imaging. Some of them can be non-invasively applied to both clinical and laboratory settings, including dynamic three-dimensional echocardiography, myocardial Doppler imaging, harmonic ultrasound imaging, and B-flow sonography. With clinical constraints, a few others have been mainly used in laboratories, such as endoscopic ultrasound, magnetic resonance imaging and biomicroscopy. Appropriate use and co-use of these new tools will not only provide unique information for better clinical assessment of fetal cardiac disease but also offer new ways to improved understanding of cardiovascular development and pathogenesis. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

19.
Congenital heart defects (CHDs), the most commonly occurring congenital malformations, cause significant mortality and morbidity. With the recognition of early markers for CHD and the development of better ultrasound resolution, interest has turned toward performing a screening anomaly scan, including the heart, together with the nuchal scan. It is also possible, with adequate skill and training, to competently perform an echocardiogram <16 weeks' gestation. This article reviews the detection of major CHD in the first trimester and early second trimester including specific markers that help to identify high-risk groups for early fetal echocardiography (EFEC). CHD detection during first-trimester screening is low (2.3–56%) depending on the center's experience and the population studied. An increased nuchal translucency, abnormal ductus venosus flow, and tricuspid regurgitation in the first trimester are associated with an increased CHD risk and can be used together to identify high-risk fetuses for EFEC. EFEC requires skilled scanning and the expertise of a fetal echocardiographer. In high-risk populations, it is 78.5% sensitive with a 74.5% concordance between the EFEC and the mid-gestational echocardiogram. The availability of qualified personnel and diagnostic accuracy are prerequisites before EFEC can be introduced into management protocols. The limitations of EFEC should be recognized, and a later confirmatory echocardiogram is recommended. © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
In a case of fetal heart failure caused by endocardial fibroelastosis, prenatal echocardiography clearly demonstrated; a thickened endocardium. We therefore suggest that an abnormal endocardium may be detected in utero by ultrasound, thus representing an important clue in the differential diagnosis of fetal nonimmune hydrops and in the evaluation of pregnancies at risk for endocardial fibroelastosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号