首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
叙述了MicrosoftWordforWindows软件在编写环境质量报告书中的应用内容。  相似文献   

2.
An air sampling method for simultaneous determination of organic acid anhydrides and isocyanates is presented. Air samples are collected in impinger flasks filled with 0.01 M di-n-butylamine (DBA) in a mixture of toluene-acetonitrile (7:3, v/v) with a 13 millimetre glass fibre filter in series. The amount of anhydrides and isocyanates are determined as their amide and urea derivatives using LC-MS. Four anhydrides, maleic anhydride (MA), phthalic anhydride (PA), tetrahydrophthalic anhydride (TA) and cis-hexahydrophthalic anhydride (HA) and 11 isocyanates could be separated in 9 minutes using gradient elution. Anhydride-DBA derivatives in standard solutions were quantified using LC with chemiluminescent nitrogen detection (CLND). Anhydride-DBA derivatives were found to be stable for at least two months when stored in acetonitrile or toluene in the freezer. The yield of DBA derivatives of anhydrides in the 0.01 M DBA in toluene-acetonitrile (7:3, v/v) was in the range of 70->95%. Using MS and negative electrospray ionisation (ES-) linear calibrations curves were obtained for the anhydrides with correlation coefficients ranging from 0.9970-0.9997. The instrumental detection limit for the anhydrides ranged from 10-30 fmol, based on a signal to noise root mean square (RMS) ratio of 3. Monitoring positive and negative ions simultaneously, both isocyanates and anhydrides could be determined as their DBA derivatives in the same chromatographic run. When air samples were collected during thermal degradation of different coated metal sheets both anhydrides and isocyanates were present in the same samples and all the studied anhydrides were found.  相似文献   

3.
4.
Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent from the filter surface. In this paper, this drawback has been overcome by changing the filter material to the less polar polystyrene divinyl benzene (SDB). A series of experiments was performed to compare the analyte uptake on the two filter materials for different sampling periods and analyte concentrations at both low and high RH conditions. Additionally, the materials were investigated as well for passive sampling of ethyl (EIC) and phenyl isocyanate (PhIC) with NBDPZ and 1-(2-methoxyphenyl) piperazine (2-MP) as an alternative derivatising agent. Using 2-MP, the mean GF/SDB response ratios were determined to be 1.02 for MIC (RSD: 6.1%) and 1.03 for EIC (RSD: 6.8%), whereas PhIC could only be determined on SDB filters. Using NBDPZ as reagent, the negative influence of high humidity disappeared when SDB filters were used instead of GF filters. Even at low RH conditions, sampling with SDB material generally resulted in a higher analyte uptake than with GF filters. The GF/SDB response ratios were independent of sampling time or analyte concentration and were determined to be 0.70 (RSD: 4.7%) for MIC, 0.84 (RSD: 4.5%) for EIC and 0.95 (RSD 5.4%) for PhIC, meaning that the NBDPZ diffusive sampler based on SDB can be used at all humidity conditions without any restrictions.  相似文献   

5.
环境监测生物安全防护是对生态环境监测中的全过程防护,在实践中,实验室内的生物安全防护研究较多,而关于现场采样人员的防护研究较少,缺乏具体可行的操作规程,若防护不当,极易对人员造成安全风险.本文对现场监测和采样中的生物安全防护问题进行了初步研究,提出了不同环境监测对象和风险条件的个人防护对策及建议,为环境监测采样过程中的...  相似文献   

6.
As a complement to traditional exposure assessment, monitoring deposition of aerosols can be a simple and quick screening method for identifying deposited aerosols. In this presentation examples of screening studies, based on wipe sampling in combination with adequate analytical techniques, are described. These screening methods are rapid, simple and easy to carry out. The examples given in this presentation show a broad applicability and the methods are proven useful for assessing aerosol distribution in the workplace as well as to identify target spots for more extensive assessment of a worker's exposure situation.  相似文献   

7.
While polyurethane foam (PUF) disk passive air samplers are employed increasingly to monitor persistent organic pollutants in indoor air, they essentially sample only the vapour phase. As a previous investigation of the vapour : particle phase partitioning of hexabromocyclododecanes HBCDs in (outdoor) air reported them to be present largely in the particulate phase, we monitored three offices using active air samplers. In each, approximately 65% of HBCDs were present in the vapour phase, suggesting PUF disk passive samplers are suitable for monitoring HBCDs in indoor air. Concentrations in the three offices (239-359 pg Sigma HBCD m(-3)) exceed substantially those reported in outdoor air from the United States (2.1-11 pg Sigma HBCD m(-3)), but are in line with outdoor air from Stockholm. The relative abundance of the three principal diastereomers in office air was closer to that found in technical HBCD formulations (i.e. predominantly gamma-HBCD) than in most US outdoor air samples. Time integrated air concentrations of alpha-, beta-, and gamma-HBCD were obtained for an office using a low volume sampler operated over a 50 d period alongside PUF disk samplers. This calibration exercise yielded the following passive air sampling rates for both a fully- and part-sheltered PUF disk sampler design: for alpha-, beta-, and gamma-HBCD, 0.87, 0.89, and 0.91 m3 d(-1) respectively (fully-sheltered) and 1.38, 1.54, and 1.55 m3 d(-1) respectively (part-sheltered). Deployment of the part-sheltered configuration yielded concentrations approximately 35% lower than those obtained using a high volume sampler, consistent with PUF disk samplers measuring primarily the vapour phase.  相似文献   

8.
A composite random sampling design was used to estimate the concentrations of hydrocarbons in sediments from two near-shore areas of Scotland (Firth of Clyde and Firth of Forth). The aim of this work was to estimate a mean value for each parameter in these areas, and to determine whether this can be done with more thorough coverage (better representation), better precision and less variance at lower analytical cost through a composite random sampling scheme rather than a simple random sampling scheme, and thereby contribute to the re-design of the UK National Marine Monitoring Programme (NMMP), re-named the UK Clean Seas Environmental Monitoring Programme (CSEMP) in 2006. Samples were collected using a simple random sampling design during 2005. All sediment samples were analysed for their particle size distribution and total organic carbon (TOC). All sediments were analysed for polycyclic aromatic hydrocarbons (PAHs) and n-alkanes. The concentrations of PAHs and n-alkanes in the study areas are described, and sources of PAHs were investigated through the PAH distributions and n-alkane profiles. Individual sediment samples from each area were combined to give a series of composite sub-samples, each comprised of 5 individual sediment samples. These composite samples were re-analysed for the same parameters as the individual samples. Mean total PAH (2- to 6-ring parent and branched) concentrations, based on the individual original sediment samples collected through simple random sampling, were 1858 microg kg(-1) dry weight (SE = 196 microg kg(-1) dry weight, n = 25) and 532.4 microg kg(-1) dry weight (SE = 59 microg kg(-1) dry weight, n = 25) in the Clyde and Forth, respectively. Mean total PAH concentrations of the composite samples were 1745 microg kg(-1) dry weight (SE = 121.0 microg kg(-1) dry weight, n = 5) in the Clyde and 511.6 microg kg(-1) dry weight (SE = 37.4 microg kg(-1) dry weight, n = 5) in the Forth. No significant differences were found between the mean PAH concentrations from the two sampling designs. This study demonstrated that the composite random sampling design gave a mean value with less variance than the simple random sampling design, at significantly reduced analytical effort (and cost).  相似文献   

9.
The need to collect data representative of overall urban pollution is all-important in order to monitor the population exposure. High spatial resolution monitoring using diffusive samplers allows studying of the urban pollutant distribution, thus enabling deeper investigation of their generation and diffusion mechanisms. Nevertheless, such a monitoring campaign has a certain cost. In this study we point out how to find the best compromise between the number of necessary measurements and the affordable costs for monitoring campaigns. We also describe an innovative method for the proper design of a fixed urban monitoring network by means of preliminary high spatial resolution campaigns using diffusive samplers. Four European capital cities (Dublin, Madrid, Paris and Rome) were monitored six times, each time for seven days. Benzene, toluene, ethylbenzene, xylenes (BTEX) and NO(2) concentrations were measured at 146 sites in Dublin, 293 in Madrid, 339 in Paris and 290 in Rome. Multiscale grids have been drawn which ranged in mesh size from 500 m to 2 km. The statistical processing of data produced a twofold result: the creation of isoconcentration maps with geostatistical procedures, and an algorithm aimed at locating the minimum number of sampling sites where the fixed monitoring stations should be placed. Average urban levels estimated on the basis of these selected sites differ by less than 8% from those calculated on the whole populations of the sampled points. The aim of this work is to investigate how far the resolution of a monitoring campaign of urban pollution by diffusive sampling can be reduced, thus making the monitoring less expensive in terms of human and financial resources, while preserving the same quality of the results that could be achieved with a higher resolution. We found that there is no significant loss of information when the resolution of the monitoring grid for BTEX is lowered to a mesh size of 1.85 km, that is a sampling site each 3.4 km(2), and that the minimum number of sampling sites to be used is N = 0.29 A, where A is the urban surface to be monitored (in km(2)). As the spatial distribution of NO(2) is less sensitive to the distance from the emission source than that of BTEX, this relationship could be retained as a valid lower limit for the mesh grid size also for NO(2) monitoring.  相似文献   

10.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

11.
An air sampling method for the determination of isocyanates, aminoisocyanates and amines formed during the thermal degradation of polyurethane (PUR) is presented. The method is based on the collection of air samples using impinger flasks containing di-n-butylamine (DBA) in toluene with a glass fibre filter in series. Isocyanates are derivatized with DBA to urea derivatives, and amines are derivatized in a subsequent work-up procedure with ethyl chloroformate (ET) to carbamate esters. Amine, aminoisocyanate and isocyanate derivatives were characterized using liquid chromatography-time of flight mass spectrometry (LC-TOFMS) and liquid chromatography-chemiluminescent nitrogen detection (LC-CLND). Quantification was performed by LC-MS, monitoring molecular ions [MH]+ in the electrospray mode. The instrumental detection limits for amines, aminoisocyanates and isocyanates were in the ranges 30-40, 2-3 and 3-70 fmol, respectively. Thermal degradation products of PUR were observed in high concentrations during welding in district heating pipes and PUR-coated metal sheets. Eleven isocyanates, three amines and five aminoisocyanates were identified. The concentrations of isocyanates, aminoisocyanates and amines in samples collected in the smoke close to the welding spot were in the ranges 150-650, 4-290 and 1-70 ppb, respectively. In samples collected in the breathing zone, isocyanates and aminoisocyanates were observed in the ranges 9-120 and 4-19 ppb, respectively. The compounds were present in both gas and particle phases. Volatile compounds dominated in the gas phase, whereas less volatile compounds dominated in the particle phase. The method presented makes it possible to sample and determine amines and aminoisocyanates, in addition to isocyanates. The need to monitor these compounds is clearly illustrated by the high concentrations found during the thermal degradation of PUR.  相似文献   

12.
Assessment of environmental and occupational exposure to chemicals can be performed with environmental monitoring (EM) and biological monitoring (BM). Biological monitoring was for a long time considered as a method complementary to environmental monitoring. At present this attitude is changing and in certain areas biological monitoring is applied as the method of choice for exposure and health-risk assessment. This paper examines advantages and disadvantages of those two approaches. In occupational settings environmental monitoring of exposure to VOCs seems to be superior to biological monitoring (possibility of simultaneous determination of components of mixtures, simple interpretation, possibility of evaluation of short-term exposure to local irritants). In the case of this group of compounds BM can be useful in selected cases such as evaluation of dermal absorption or efficiency of protective measures. In the case of metals both forms of monitoring can be used depending on the available methods for interpretation of results. BM of exposure may be considered as superior for evaluating the effects of exposure to lead, cadmium and mercury. However, quantitative evaluation of cancer risk after exposure to arsenic or chromium is possible only on the basis of determination in the air and the use of unit risk values. Both environmental and biological monitoring are useful for evaluation of occupational and environmental exposure to polycyclic aromatic hydrocarbons (PAHs). In certain areas such as evaluation of exposure to external tobacco smoking, cytostatic drugs, and pesticides, biological monitoring is the method of choice used for individual exposure assessment or tracing the trends of environmental exposure.  相似文献   

13.
The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.  相似文献   

14.
环境空气质量自动监测系统管理   总被引:5,自引:1,他引:5  
针对目前我国监测站环境空气自动监测的发展和管理现状,建立健全城市环境空气自动监测的管理制度和相应的技术档案十分必要。  相似文献   

15.
A new method for multi-objective optimization of air quality monitoring systems based on satellite remote sensing of the troposphere is described in this work. The technique uses atmospheric turbidity as surrogate for air pollution loading. Through inverse chemical modeling and ancillary information the respective patterns of primary gaseous and particle pollutants are inferred. The optimization algorithm uses the resulting maps of ambient air pollution as input. It focuses on the gain of information with regard to human exposure to high pollution, potential impact on cultural heritage, compliance to ambient air quality standards, monitoring key point and area source emissions, as well as on the associated cost. Application of the method in Brescia, Italy showed its significant potential for improving the cost-effectiveness of air quality monitoring networks at the urban and regional scales.  相似文献   

16.
Aqueous triethanolamine (TEA) solutions are widely used as sorption medium for passive sampling of ambient NO2, with NO2 trapped and accumulated as nitrite ion. The results of test measurements of ambient NO2 concentrations using passive sampling method showed that the simple approach commonly used to describe passive sampling process might lead to substantial systematic errors. Presented in the article is a new physicochemical model of the process of passive sampling of gaseous NO2, with aqueous TEA solution used as a trapping medium. The model is based on the available results of experimental studies of interaction of gaseous NO2 with TEA/water solutions. The key principles underlying the model are: (1) when absorbed by a trapping solution, NO2 forms nitrite ion only on the condition that TEA is hydrated; (2) coefficient of conversion of NO2 to NO 2 ? is equal to one when reacting with hydrated TEA; and (3) the fraction of hydrated TEA molecules depends on air humidity at the moment of measurement. Validation of the model was made using the data of the field measurements carried out in the Middle Urals in 2007–2009. The new model was used to calculate average NO2 concentrations. Concentrations calculated agreed well with the results obtained by reference methods. The difference between the datasets was statistically insignificant.  相似文献   

17.
A novel, low-cost passive sampling procedure for monitoring of volcanogenic hydrogen sulfide is reported. The technique is based on absorption of H2S onto treated sections of photographic paper, which are housed in plastic film canisters during exposure. The H2S reacts with silver halide in the photographic paper, causing a colour-change reaction from white, through brown, to black, depending on concentration of atmospheric H2S. The sampler is sensitive to < 30 ppb to approximately 1000 ppb of H2S. Here we present results from a series of optimization and quantification experiments. An active sampling procedure for rapid H2S measurement is also reported, based on absorption of H2S onto Whatman No. 41 cellulose filters treated with silver nitrate, and was shown to be quantitative using a single filter at flow rates <1.0 L min(-1) for collection of <200 microg of sulfide (as H2S). Determination of sulfide collected on the substrates was performed using a rapid flow-injection technique based on the fluorescence quenching of fluorescein mercuric acetate (FMA) by sulfide. This was optimized at a FMA concentration of 8 mg L(-1), at which 100% quenching was obtained at a solution sulfide concentration of 3 mg L(-1).  相似文献   

18.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

19.
介绍大气采样泵的高性能技术要求、生产和使用现状及高性能旋转式气泵的研制。  相似文献   

20.
Passive sampling of glycol ethers and their acetates in indoor air   总被引:1,自引:0,他引:1  
This study examined the performances of a thermal desorbable radial diffusive sampler for the weekly measurement of eight glycol ethers in indoor air and described the results of an application of this method carried out as part of HABIT'AIR Nord - Pas de Calais program for the air monitoring of these compounds in sixty homes located in northern France. The target compounds were the four glycol ethers banned from sale to the public in France since the 1990s (i.e. 2-methoxy ethanol, 2-ethoxy ethanol and their acetates) and four other glycol ethers derivatives of which the use have increased considerably (i.e. 1-methoxy-2-propanol, 2-butoxy ethanol and their acetates).A test program was carried out with the aim of validating the passive sampling method. It allowed the estimation of all the parameters of a method for each compound (calibration, analytical precision, desorption efficiency, sampling rate in standard conditions, detection limit and stability of sample before and after exposure), the examination of the influence of environmental factors on the sampling rate by some exposure chamber experiments and the assessment of the uncertainty of the measurements.The results of this evaluation demonstrated that the method has turned out to be suitable for six out of eight glycol ethers tested. The effect of the environmental factors on the sampling rates was the main source of measurement uncertainty. The measurements done in sixty homes revealed a relative abundance of 1-methoxy-2-propanol that was found in more than two thirds of homes at concentration levels of 4.5 microg m(-3) on average (a maximum value of 28 microg m(-3)). 1-methoxy-2-propanol acetate and 2-butoxy ethanol were also detected, but less frequently (in 19% of homes) and with the concentrations below 12 microg m(-3). The highest levels of these glycol ethers appear to be in relation to the emissions occurring at the time of cleaning tasks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号