首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Statistically significant downward trends in measured UK annual mean PM10 concentrations have been observed at eight out of the nine urban background monitoring sites between the start of monitoring in 1992 or 1993 and 2000.Site-specific projections of the individual components of measured PM10 concentrations have been derived for the period 1992–2000 at three monitoring sites from receptor modelling results for 1999 monitoring data. Measured annual average PM10 concentrations declined to between 71% and 66% of the 1992 values during this period at the sites studied. The largest contributions to the decline in total PM10 are from secondary particles at London Bloomsbury (40%, 3.4 μg m−3, tapered element oscillating microbalance (TEOM)), stationary sources at Belfast Centre (53%, 4.6 μg m−3, TEOM) and roadside traffic emissions at Bury Roadside (49%, 5.0 μg m−3, TEOM). The good agreement between the projected total PM10 concentrations and measured values for the years 1992–2000 indicate that the combination of the receptor model and the site-specific projections provide a suitably robust method for predicting future PM10 concentrations and the quantification of the impact of possible future policy measures to reduce PM10 concentrations. The good agreement between the projections and measured concentration also provides a useful verification of the trends in emissions inventory estimates for the 1990s.Projections of estimated PM10 concentrations have also been calculated for the London Bloomsbury site for the period from 1970 to 1991. Annual mean concentrations are predicted to have been in the range from 30 to 35 μg m−3, TEOM from 1977 to 1991 but much higher at values between 39 and 46 μg m−3, TEOM in the early 1970s.  相似文献   

2.
A modelling method has been developed to map PM10 and PM2.5 concentrations across the UK at background and roadside locations. Separate models have been calibrated using gravimetric measurements and Tapered Element Oscillating Microbalance instruments (TEOM) using source apportionments appropriate to the size fractions and sampling methods. Maps have been prepared for a base year of 2004 and predictions have been calculated for 2010 and 2020 on the basis of current policies. Comparisons of the modelling results with air quality regulations suggest that exceedences of the EU Daughter Directive stage 1 24-h limit value for PM10 at the roadside in 2004 will be largely eliminated by 2020. The concentration cap of 25 μg m−3 for PM2.5 proposed within the CAFÉ Directive is expected to be met at all locations. Projections for 2010 and 2020 suggest that the proposed exposure reduction (ER) target is likely to be considerably more stringent and require additional measures beyond current policies. Thus the model results suggest that the balance between the stringency of the concentration cap and the ER target in the proposed directive is appropriate. Measures to achieve greater reductions should therefore have the maximum public health benefit and air quality policy is not driven by the need to reduce concentrations at isolated ‘hotspots’.  相似文献   

3.
Air quality in Cyprus is influenced by both local and transported pollution, including desert dust storms. We examined PM10 concentration data collected in Nicosia (urban representative) from April 1, 1993, through December 11, 2008, and in Ayia Marina (rural background representative) from January 1, 1999, through December 31, 2008. Measurements were conducted using a Tapered Element Oscillating Micro-balance (TEOM). PM10 concentrations, meteorological records, and satellite data were used to identify dust storm days. We investigated long-term trends using a Generalized Additive Model (GAM) after controlling for day of week, month, temperature, wind speed, and relative humidity. In Nicosia, annual PM10 concentrations ranged from 50.4 to 63.8 μg/m3 and exceeded the EU annual standard limit enacted in 2005 of 40 μg/m3 every year. A large, statistically significant impact of urban sources (defined as the difference between urban and background levels) was seen in Nicosia over the period 2000–2008, and was highest during traffic hours, weekdays, cold months, and low wind conditions. Our estimate of the mean (standard error) contribution of urban sources to the daily ambient PM10 was 24.0 (0.4) μg/m3. The study of yearly trends showed that PM10 levels in Nicosia decreased from 59.4 μg/m3 in 1993 to 49.0 μg/m3 in 2008, probably in part as a result of traffic emission control policies in Cyprus. In Ayia Marina, annual concentrations ranged from 27.3 to 35.6 μg/m3, and no obvious time trends were observed. The levels measured at the Cyprus background site are comparable to background concentrations reported in other Eastern Mediterranean countries. Average daily PM10 concentrations during desert dust storms were around 100 μg/m3 since 2000 and much higher in earlier years. Despite the large impact of dust storms and their increasing frequency over time, dust storms were responsible for a small fraction of the exceedances of the daily PM10 limit.
ImplicationsThis paper examines PM10 concentrations in Nicosia, Cyprus, from 1993 to 2008. The decrease in PM10 levels in Nicosia suggests that the implementation of traffic emission control policies in Cyprus has been effective. However, particle levels still exceeded the European Union annual standard, and dust storms were responsible for a small fraction of the daily PM10 limit exceedances. Other natural particles that are not assessed in this study, such as resuspended soil and sea salt, may be responsible in part for the high particle levels.  相似文献   

4.
Abstract

In 1997, Maryland had no available ambient Federal Reference Method data on particulate matter less than 2.5 μm in aerodynamic diameter (PM2.5), but did have annual ambient data for PM smaller than 10 μm (PM10) at 24 sites. The PM10 data were analyzed in conjunction with local annual and seasonal zip-code-level emission inventories and with speciated PM2.5 data from four nearby monitors in the IMPROVE network (located in the national parks, wildlife refuges, and wilderness areas) in an effort to estimate annual average and seasonal high PM2.5 concentrations at the 24 PM10 monitor sites operating from 1992 to 1996. All seasonal high concentrations were estimated to be below the 24-hr PM2.5 National Ambient Air Quality Standards (NAAQS) at the sites operating in Maryland between 1992 and 1996. The estimates also indicated that 12 monitor sites might exceed the 3-year annual average PM2.5 NAAQS of 15 ug/m3, but Maryland’s air quality shows signs that it has been improving since 1992. The estimates also were compared with actual measurements after the PM2.5 monitor network was installed. The estimates were adequate for describing the chemical composition of the PM2.5, forecasting compliance status with the 24-hr and annual standards, and determining the spatial variations in PM2.5 across central Maryland.  相似文献   

5.
Inhalation of particulate pollutants below 10 μm in size (PM10) is associated with adverse health effects. Here we use magnetic remanence measurements of roadside tree leaves to examine levels of vehicle-derived PM around Lancaster, UK. Leaf saturation remanence (SIRM) values exhibit strong correlation with both the SIRM and particulate mass of co-located, pumped-air samples, indicating that these leaf magnetic values are an effective proxy for ambient PM10 concentrations. Biomagnetic monitoring using tree leaves can thus provide high spatial resolution data sets for assessment of particulate pollution levels at pedestrian-relevant heights. Leaf SIRM values not only increase with proximity to roads with higher traffic volumes, but are also ~100% higher at 0.3 m than at ~1.5–2 m height. Magnetic and SEM data indicate that the particle populations are dominated by spherical, iron-rich particles ~0.1–1 μm in diameter, with fewer larger, more angular, silica-rich particles. Comparison of the roadside leaf-calculated PM10 concentrations with PM10 concentrations predicted by a widely-used atmospheric dispersion model indicates some agreement between them. However, the model under-predicts PM10 concentrations at ‘urban hotspots’ such as major–minor road junctions and traffic lights. Conversely, the model over-predicts PM10 concentrations with distance from the road wherever one tree is screened by another, indicating the filtering/protective effect of roadside trees in leaf.  相似文献   

6.
Personal measurements of exposure to particulate air pollution (PM10, PM2.5, PM1) were simultaneously made during walking and in-car journeys on two suburban routes in Northampton, UK, during the winter of 1999/2000. Comparisons were made between concentrations found in each transport mode by particle fraction, between different particle fractions by transport mode, and between transport microenvironments and a fixed-site monitor located within the study area. High levels of correlation were seen between walking and in-car concentrations for each of the particle fractions (PM10: r2=0.82; PM2.5: r2=0.98; PM1: r2=0.99). On an average, PM10 concentrations were 16% higher inside the car than for the walker, but there were no difference in average PM2.5 and PM1 concentrations between the two modes. High PM2.5:PM10 ratios (0.6–0.73) were found to be associated with elevated sulphate levels. The PM2.5:PM10 and PM1:PM2.5 ratios were shown to be similar between walking and in-car concentrations. Concentrations of PM10 were found to be more closely related between transport mode than either mode was with concentrations recorded at the fixed-site (roadside) monitor. The fixed-site monitor was shown to be a poor marker for PM10 concentrations recorded during walking and in-car on a route over 1 km away.  相似文献   

7.
ABSTRACT

In December 1994, the South Coast Air Quality Management District (SCAQMD) initiated a comprehensive program, the PM10 Technical Enhancement Program (PTEP), to characterize fine PM in the South Coast Air Basin (SCAB). A 1-year special particulate monitoring project was conducted from January 1995 to February 1996 as part of the PTEP. Under this enhanced monitoring, HNO3, NH3, and speciated PM10 and PM2.5 concentrations were measured at five stations (Anaheim, downtown Los Angeles, Diamond Bar, Fontana, and Rubidoux) in the SCAB and at one background station at San Nicolas Island. PM2.5 and PM10 mass and 43 individual species were analyzed for a full chemical speciation of the particle data. The PTEP data indicate that the most abundant chemical components of PM10 and PM25 in the SCAB are NH4+ (8-9% of PM10 and 14-17% of PM25), NO3 - (23-26% of PM10 and 28-41% of PM25), SO4= (6-11% of PM10 and 9-18% of PM2 5), organic carbon (OC) (15-19% of PM10 and 18-26% of PM2.5), and elemental carbon (EC) (5-8% of PM10 and 8-13% of PM25). On an annual average basis, PM25 comprises 52-59% of the SCAB PM10. Annual average PM10 and PM2.5 concentrations showed strong spatial variations, low at coastal sites and high at inland sites. Annual average PM10 concentrations varied from 40.8 ug/m3 at Anaheim to 76.8 ug/m3 at Rubidoux, while annual average PM2.5 concentrations varied from 21.7 ug/m3 at Anaheim to 39.8 ug/m3 at Rubidoux. The chemical characterizations of the PM2.5 and PM10 concentrations, as well as their spatial variations, were examined; the important findings are summarized in this paper, and the temporal variations are discussed in the companion paper.1  相似文献   

8.
In 2007, the European limit values for annual average nitrogen dioxide (NO2) concentration and for daily average particulate matter (PM10) concentration were exceeded along motorways and city streets in the Netherlands. While the road length along which the exceedance occurred is uncertain, model calculations show that the NO2 concentration was likely to have been exceeded (chance >66%) along about 300 km and PM10 concentration along about 75 km. In addition, the limit values were exceeded ‘about as likely as not’ (chance 33–66%) along a total of 1000 km for NO2 and 1600 km for PM10. PM10 and NO2 concentrations must be below the limit values everywhere in Europe, ultimately by 2011 and 2015, respectively. Since estimates of future local concentrations have an uncertainty of about 15–20%, no absolute statements can be made whether concentrations will be below the limit values within the specified time. Model calculations accounting for the effects of current and proposed national and European legislation, and using average meteorology for large-scale and local traffic contributions show strong decreases in likely limit value exceedances in the Netherlands. However, limit value exceedances are still possible (chance >33%) along about 350 km for PM10 by 2011, and about 150 km for NO2, by 2015. These possible exceedances depend not only on the uncertainties and on national and European policies and their effectiveness, but also on contributions by specific additional local measures. The Netherlands Government has proposed a plan, which includes local measures to meet the limit values everywhere, in time. Although not assessed here due to their specific character, such local measures could reduce exceedances. As the effects of local measures and estimates of concentrations are uncertain, continuous monitoring – possibly together with additional measures – will be needed to adhere to the limit values.  相似文献   

9.
The Detroit Exposure and Aerosol Research Study (DEARS) provided data to compare outdoor residential coarse particulate matter (PM10–2.5) concentrations in six different areas of Detroit with data from a central monitoring site. Daily and seasonal influences on the spatial distribution of PM10–2.5 during Summer 2006 and Winter 2007 were investigated using data collected with the newly developed coarse particle exposure monitor (CPEM). These data allowed the representativeness of the community monitoring site to be assessed for the greater Detroit metro area. Multiple CPEMs collocated with a dichotomous sampler determined the precision and accuracy of the CPEM PM10–2.5 and PM2.5 data.CPEM PM2.5 concentrations agreed well with the dichotomous sampler data. The slope was 0.97 and the R2 was 0.91. CPEM concentrations had an average 23% negative bias and R2 of 0.81. The directional nature of the CPEM sampling efficiency due to bluff body effects probably caused the negative CPEM concentration bias.PM10–2.5 was observed to vary spatially and temporally across Detroit, reflecting the seasonal impact of local sources. Summer PM10–2.5 was 5 μg m?3 higher in the two industrial areas near downtown than the average concentrations in other areas of Detroit. An area impacted by vehicular traffic had concentrations 8 μg m?3 higher than the average concentrations in other parts of Detroit in the winter due to the suspected suspension of road salt. PM10–2.5 Pearson Correlation Coefficients between monitoring locations varied from 0.03 to 0.76. All summer PM10–2.5 correlations were greater than 0.28 and statistically significant (p-value < 0.05). Winter PM10–2.5 correlations greater than 0.33 were statistically significant (p-value < 0.05). The PM10–2.5 correlations found to be insignificant were associated with the area impacted by mobile sources during the winter. The suspected suspension of road salt from the Southfield Freeway, combined with a very stable atmosphere, caused concentrations to be greater in this area compared to other areas of Detroit. These findings indicated that PM10–2.5, although correlated in some instances, varies sufficiently across a complex urban airshed that that a central monitoring site may not adequately represent the population's exposure to PM10–2.5.  相似文献   

10.
A new personal PM10 sampling head has been developed by the Institute of Occupational Medicine (IOM), Edinburgh. The purpose of this study was to compare its performance in the field with the accepted fixed-location PM10 sampler, the tapered element oscillating microbalance (TEOM). The comparisons were carried out on three separate occasions during 1997 at each of two city centre locations in the UK. On each occasion two personal IOM PM10 sampling heads were located adjacent to a TEOM monitor and four successive sets of 24-h filter samples were collected. The data was compared with 24-h average TEOM concentrations, calculated as the arithmetic mean of the recorded hourly averages. There was a statistically significant linear relationship between the two types of monitor, although the concentrations from the IOM PM10 samplers were consistently higher than the TEOM data. It is therefore possible to use the regression equations presented in this paper to correct ambient PM10 concentrations measured by either method to equivalent values. Further research is needed to properly understand the reason for the difference between the TEOM and filter samplers.  相似文献   

11.
The models HARM and ELMO are used to investigate the importance of different source categories contributing to total PM10 (SIA, SOA and primary particulate matter) across the UK and the impact of uncertainties on both present day and future concentration estimates. Modelled concentrations of SIA (secondary inorganic aerosol) are compared against data from the UK's Nitric Acid and Aerosol Network and SOA (secondary organic aerosol) against measurements made at the Bush Estate, Edinburgh. These data indicate that the HARM/ELMO modelling approach comes close to achieving mass closure. Comparison with national maps of total PM10 indicate that the models underestimate particulate matter concentrations around large conurbations, probably due to the localised nature of emissions of primary particulates in these areas and model scale. The models are used to attribute particulate matter to different source and size categories, assessing the relative importance of primaries, SIA and SOA; the contributions of anthropogenic and biogenic precursors of SOA; the relative importance of PMcoarse (PM10–PM2.5) and PMfine (PM2.5) and UK vs. other EMEP area sources. The implications of these attributions for emissions control policies are discussed. The impact of uncertainties in emissions of the sources of primaries, SIA and SOA are explored. For primary PM10 and SOA this has been achieved through emissions scaling and for SIA using the GLUE (Generalised Likelihood Uncertainty Estimation) approach. The selection of acceptable model parameter sets has been based on the need to retain the capability to model deposition of S and N species. The impact of uncertainty on estimates of present day SIA concentrations is illustrated for sites in the Nitric Acid and Aerosol Network. A more limited assessment for 2010 has been carried out at the national scale, illustrating that inclusion of uncertainty can change modelled concentrations from no exceedance of current air quality objectives, to one of exceedance over large areas of south and east England.  相似文献   

12.
This paper synthesizes data on aerosol (particulate matter, PM) physical and chemical characteristics, which were obtained over the past decade in aerosol research and monitoring activities at more than 60 natural background, rural, near-city, urban, and kerbside sites across Europe. The data include simultaneously measured PM10 and/or PM2.5 mass on the one hand, and aerosol particle number concentrations or PM chemistry on the other hand. The aerosol data presented in our previous works (Van Dingenen et al., 2004, Putaud et al., 2004) were updated and merged to those collected in the framework of the EU supported European Cooperation in the field of Scientific and Technical action COST633 (Particulate matter: Properties related to health effects). A number of conclusions from our previous studies were confirmed. There is no single ratio between PM2.5 and PM10 mass concentrations valid for all sites, although fairly constant ratios ranging from 0.5 to 0.9 are observed at most individual sites. There is no general correlation between PM mass and particle number concentrations, although particle number concentrations increase with PM2.5 levels at most sites. The main constituents of both PM10 and PM2.5 are generally organic matter, sulfate and nitrate. Mineral dust can also be a major constituent of PM10 at kerbside sites and in Southern Europe. There is a clear decreasing gradient in SO42? and NO3? contribution to PM10 when moving from rural to urban to kerbside sites. In contrast, the total carbon/PM10 ratio increases from rural to kerbside sites. Some new conclusions were also drawn from this work: the ratio between ultrafine particle and total particle number concentration decreases with PM2.5 concentration at all sites but one, and significant gradients in PM chemistry are observed when moving from Northwestern, to Southern to Central Europe. Compiling an even larger number of data sets would have further increased the significance of our conclusions, but collecting all the aerosol data sets obtained also through research projects remains a tedious task.  相似文献   

13.
ABSTRACT

The South Coast Air Quality Management District (SCAQMD) conducted a 1-year special particulate monitoring study from January 1995 to February 1996. This monitoring data indicates that high PM10 and PM2 5 concentrations were observed in the fall (October, November, and December), with November concentrations being the highest. During the rest of the year, PM2.5 and PM10 masses gradually increased from January to September. Monthly PM10 mass varied from 20 to 120 |ig/m3, and monthly PM25 mass varied from 13 to 63 |j.g/m3. The PM2.5-to-PM10 ratio varied daily and ranged between 22 and 96%. Two types of high-PM days were observed. The first type was observed under fall stagnation conditions, which lead to high secondary species concentrations. The second type was observed under high wind conditions, which lead to high primary coarse particles of crustal components. The highest 24-hr average PM10 concentration (226.3 |ig/m3) was observed at the Fontana station, while the highest PM25 concentration (129.3 |ig/m3) was observed at the Diamond Bar station.  相似文献   

14.
Vertical profiling with point samplers is an accepted method for quantifying the fluxes of PM10 from non-point fugitive dust sources, but is limited by uncertainty in estimates of the actual height of the dust plume, especially for plumes that exceed the highest sampling height. Agricultural land preparation operations in the San Joaquin Valley were monitored using upwind–downwind vertical PM10 profiles and data collected during the first successful experiment to include light detection and ranging (lidar), in 1998, were analyzed to provide modeling criteria for the 1996 and 1997 data. A series of six comprehensive PM10 tests with concurrent lidar data was examined to: (a) develop a framework for analyzing upwind–downwind point PM10 concentration profiles of land preparation operations (disking, listing, root cutting, and ripping) and (b) identify conditions under which the field sampling strategies affect the reproducibility of PM10 concentration measurements. Lidar data were used to verify that the plume heights and shapes extrapolated from the point sampler vertical profiles adequately described the plumes. The shortcomings of the vertical profiling technique and lidar methods are discussed in the light of developing efficient robust methods for accurate PM10 emissions quantification from complex non-point sources.  相似文献   

15.
This study analyzed time-series data of air pollutants, O3 and PM10, to determine the division of air-quality basins in Taiwan by employing multivariate statistical methods, Varimax rotational method and cluster analysis. The databases of air pollutants, daily maximum 1-h O3 and daily mean PM10 concentrations, were obtained from the ROC Environmental Protection Administration (ROC EPA) for the period from 1 July 1993 to 30 June 1998. The Varimax rotational method allowed us to delineate five homogenous PM10 subregions that cumulatively accounted for 85.6% of the total variance. The time-series analysis of rotated component scores associated with the PM10 subregions revealed that all divided subregions presented a strong seasonal cycle. Four of five subregions had higher component scores and PM10 concentrations from November to January. One subregion experienced higher values from March to May. The use of Varimax approach and cluster analysis on the O3 and PM10 confirmed that O3 was more demonstrative of the air-quality basins in Taiwan. Both the Varimax rotational method and the cluster analysis have specific advantages for the division of air-quality basins. This study also proposes a delineation of five air-quality basins having homogenous O3 features as an alternative assignment of atmospheric carrying capacity control regions.  相似文献   

16.
In many European cities mass concentrations of PM10 (particles less than 10 μm in size) are still exceeding air quality standards as set by the European Commission in 1999. As a consequence, many cities introduced low emission zones (LEZs) to improve air quality and to meet the limit values. In Germany currently 48 LEZs are in operation. By means of dispersion modeling, PM10 concentrations were estimated to decrease up to 10%. Analysis of PM10 levels conducted for Cologne, Berlin, and Munich some time after the LEZs were introduced showed reduction of PM10 mass concentration in the estimated range. The PM10 particle fraction is, however, composed of particles with varying toxicity, of which diesel soot is highly health relevant. An evaluation of air quality data conducted in Berlin showed that in 2010 traffic-related soot concentrations measured along major roads decreased by 52% compared to 2007. Diesel particle emissions in Berlin were reduced in 2012 by 63% compared to a business-as-usual scenario (reference year 2007). A strong reduction of the traffic-related particle fraction of PM2.5 was also reported for Munich. Therefore, it is likely that the effects of LEZs are considerably more significant to human health than was anticipated when only considering the reduction of PM10 mass concentrations.
Implications: The implementation of low emission zones in German cities might result in a reduction of PM10 levels concentrations by up to 10%. However, it is difficult to show a reduction of PM10 annual averages in this order of magnitude as meteorology has a large impact on the year-to-year variation of PM mass concentrations. Monitoring of other PM metrics such as black smoke (BS) or elemental carbon (EC) might be a better strategy for evaluating LEZs effects. The benefit of low emission zones on human health is far greater than is presently visible from routine measurements of PM10.  相似文献   

17.
ABSTRACT

Time-resolved data is needed for public notification of unhealthful air quality and to develop an understanding of atmospheric chemistry, including insights important to control strategies. In this research, continuous fine particulate matter (PM2.5) mass concentrations were measured with tapered element oscillating microbalances (TEOMs) across New Jersey from July 1997 to June 1998. Data features indicating the influence of local sources and long-distance transport are examined, as well as differences between 1-hr maxima and 24-hr average concentrations that might be relevant to acute health effects. Continuous mass concentrations were not significantly different from filter-collected gravimetric mass concentrations with 95% confidence intervals during any season. Annual mean PM2.5 concentrations from July 1997 to June 1998 were 17.3, 16.4, 14.1, and 15.3 μg/m3 at Newark, Elizabeth, New Brunswick, and Camden, NJ, respectively. Monthly averaged 24- and 1-hr daily maximum PM2.5 concentrations suggest the existence of a high PM2.5 (May-October) and a low PM2.5 (November-April) season.

PM2.5 magnitudes and temporal trends were very similar across the state during high PM2.5 events. In fact, the between-site coefficients of determination (R2) for daily PM2.5 measurements were 84-98% for June and July. Additionally, during the most pronounced PM2.5 episode, PM2.5 concentrations closely tracked the daily maximum 1-hr O3 concentrations. These observations suggest the importance of transport and atmospheric chemistry (i.e., secondary formation) to PM2.5 episodes in New Jersey. The influence of local sources was observed in diurnal concentration profiles and annual average between-site differences. Urban wintertime data illustrate that high 1-hr maximum PM2.5 concentrations can occur on low 24-hr PM2.5 days.  相似文献   

18.
重庆市春季大气颗粒物浓度的对比监测分析   总被引:2,自引:1,他引:1  
通过2012年春季在重庆大气超级站进行的PM10和PM2.5手工采样与自动仪器的对比监测,分析了自动监测与手工监测的一致性及造成偏差的原因,并对PM2.5与PM10浓度的比值关系进行了分析。结果表明:MP101M型颗粒物自动监测仪用于监测PM10时系统性误差偏高,仪器初始精密度存在负偏差;用于监测PM2.5时系统性误差在允许范围之内,仪器初始精密度存在较大负偏差;PM10和PM2.5的手工采样和自动仪器监测值之变化趋势具有非常高的一致性;PM2.5与PM10浓度比值范围在56.5%~90.4%,平均比值为(73.8±7.4)%。  相似文献   

19.
ABSTRACT

The chemical mass balance (CMB) model was applied to winter (November through January) 1991–1996 PM2.5 and PM10 data from the Sacramento 13th and T Streets site in order to identify the contributions from major source categories to peak 24-hr ambient PM2.5 and PM10 levels. The average monthly PM10 monitoring data for the nine-year period in Sacramento County indicate that elevated concentrations are typical in the winter months. Concentrations on days of highest PM10 are dominated by the PM2.5 fraction. One factor contributing to increased PM2.5 concentrations in the winter is meteorology (cool temperatures, low wind speeds, low inversion layers, and more humid conditions) that favors the formation of secondary nitrate and sulfate aerosols. Residential wood burning also elevates fine particulate concentrations in the Sacramento area.

The results of the CMB analysis highlight three key points. First, the source apportionment results indicate that primary motor vehicle exhaust and wood smoke are significant sources of both PM2.5 and PM10 in winter. Second, nitrates, secondarily formed as a result of motor-vehicle and other sources of nitrogen oxide (NOx), are another principal cause of the high PM2.5 and PM10 levels during the winter months. Third, fugitive dust, whether it is resuspended soil and dust or agricultural tillage, is not the major contributor to peak winter PM2.5 and PM10 levels in the Sacramento area.  相似文献   

20.
An analysis is presented of continuous simultaneous measurement data for PM10 and PM2.5 using TEOM instruments from five sites in the United Kingdom. The results are analysed specifically in relation to the sources and processes influencing the coarse particle fraction (2.5–10 μm). The data show a generally strong correlation between fine and coarse particle concentrations at all sites, with a generally higher proportion of coarse particles in the dryer months of the year. The one rural site shows a notably lower proportion of coarse particles than the urban and suburban sites. Whilst it is possible to disaggregate the coarse particle concentrations into a component which is diluted by increasing windspeed and a component which increases with windspeed and is hence possibly attributable to wind-induced resuspension processes, the latter is only a minor proportion of the total coarse particle concentration. There are appreciable weekday-to-weekend and day-to-night differences between coarse particle concentrations which are most marked at the urban sites indicative of anthropogenic activities being a source of coarse particles. The clearest indication of the likely predominant source of coarse particles arises from an analysis of a data set derived from an urban street canyon site after subtraction of measurements from a nearby urban background location. The data indicate strong relationships of both fine and coarse incremental particle concentrations in the street canyon with incremental NOx. If incremental fine particles and coarse particles are attributed to exhaust emissions and vehicle-induced resuspension, respectively, then it may be concluded that vehicle-induced resuspension provides a source strength approximately equal to that of exhaust emissions. An analysis of the coarse particle concentration data suggest that episodes of elevated coarse particle concentrations alone very rarely lead to exceedence of the UK air quality standard for PM10 of 50 μg m−3 measured as a 24-h running mean.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号