首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
Phoenix Services, Inc., owns and operates the Baltimore Regional Medical Waste Incinerator in Baltimore, MD. New regulations for dioxins and furans imposed a limit that was considerably below historical emission levels. To determine a method to comply with the new dioxin/furan regulations, Phoenix Services performed trials with powdered activated carbon (PAC). Although the results with carbon were acceptable, Phoenix Services decided to replace their woven fiberglass filter bags with catalytic filters that simultaneously destroy dioxins and furans and collect particulate matter (PM). The catalytic filter system offered several advantages to Phoenix Services, including destruction of dioxins and furans instead of adsorption on carbon. The catalytic filters also offered a passive solution that did not require new carbon injection equipment. In January 2000, a campaign to measure dioxins/furans and PM was undertaken. The measurements allowed the catalytic filter system to be evaluated. Some of the key findings of this investigation are The dioxin/furan emission was less than 0.1 ng toxicity equivalents (TEQ)/Nm3 at 11% O2. This concentration is approximately 2 orders of magnitude less than historical averages and it is well below the new regulatory limits, for both existing and new sources of this type; the amount of dioxin/furans destroyed by the catalytic filters was approximately 1.73 ng TEQ/Nm3 at 11% O2; and the particulate emission was 12-17 times less than the regulatory limit.  相似文献   

2.
ABSTRACT

Phoenix Services, Inc., owns and operates the Baltimore Regional Medical Waste Incinerator in Baltimore, MD. New regulations for dioxins and furans imposed a limit that was considerably below historical emission levels. To determine a method to comply with the new dioxin/furan regulations, Phoenix Services performed trials with powdered activated carbon (PAC). Although the results with carbon were acceptable, Phoenix Services decided to replace their woven fiberglass filter bags with catalytic filters that simultaneously destroy dioxins and furans and collect particulate matter (PM). The catalytic filter system offered several advantages to Phoenix Services, including destruction of dioxins and furans instead of adsorption on carbon. The catalytic filters also offered a passive solution that did not require new carbon injection equipment. In January 2000, a campaign to measure dioxins/furans and PM was undertaken.  相似文献   

3.
Evaluation of the dioxin removal efficiency of the air pollution control device (APCD) at an existing municipal waste incinerator (MWI) located in Taiwan is conducted via stack sampling and analysis. The MWI investigated is equipped with cyclones, dry lime scrubbing systems and fabric filters as APCDs. Results indicate that the patterns of dioxin isomers at APCDs' inlet and stack are similar. During the first year of carbon injection, the concentrations of emitted dioxin decreased greatly. The dioxin removal efficiency increased from 26.9% to 96.6% after injecting 115 kg/day activated carbon (AC). At the second year, the dioxin removal efficiency reaches 98.7% after injecting the same rate of AC continuously. The lower efficiency achieved with activated carbon injection (ACI) during the first year can be attributed to the memory effect, i.e. the dioxin or precursor desorbs slowly to the flue gas and increases the dioxin concentration at stack, resulting in a lower dioxin removal efficiency than expected.  相似文献   

4.
Abstract

A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes ~1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 107 yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octachlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Qf) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Qf/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases ≤90%.  相似文献   

5.
Five materials were used in gas-solid phase reactions between dibenzo-p- dioxin(DD) and HCl in order to determine the role of organic and inorganic components in fly ash on chlorine substitution reactions of chlorinated dioxins. The five solids were: granular activated carbon, silica gel, diatomaceous earth, Tenax-GC, and fly ash. Conditions for reactions were 10 min at 150°C with 5% HCl in air. Extent of chlorination was measured using GC/MS analyses of extracts of fly ash after treatment processes and was expressed as the ratio monochloroDD/original unreacted DD. These ratios were: fly ash, 1.082; silica gel, 0.059; activated carbon, 0.024; and Tenax-GC, 0.001. Measurement of similar behavior on diatomaceous earth was impossible since starting material and possible products were irreversibly adsorbed completely. The major chlorinated dioxin produced under these conditions was 2-chlorodibenzo-p- dioxin which is the isomer favored through an electrophilic substitution mechanism.  相似文献   

6.
Hung WT  Lin CF 《Chemosphere》2003,53(7):727-735
Catalytic destruction of chlorinated compounds is one of the key methods in reducing pollutant emissions. For the purpose of utilizing waste materials, a catalyst was regenerated from ferric ion sludge, obtained from the addition of iron salts to precipitate heavy metals. The sludge was dewatered, heated (800 degrees C for 4 h), and ground into smaller particles. The regenerated ferric oxide particles were then used as the oxidation catalyst to destroy CO formation during the combustion of three chlorinated solvents and to suppress dioxin formation in flue gas in a real waste solvent. In the presence of catalyst, the combustion efficiency (ratio of CO(2) to the sum of CO(2) and CO) for chlorobenzene was more than 98% at 850 degrees C in a pilot-scale incinerator. The destruction and removal efficiencies of chlorobenzene, 2,4-dichlorophenol and trichlorofluoroethane were more than three nines. In the absence of catalysts, the flue gas emission from a real waste could not meet the regulatory dioxin standard of 0.1 ng-TEQ/Nm(3) even with the powdered activated carbon injection. The use of catalyst at either 100 or 300 g/h, however, was able to meet the emission standard.  相似文献   

7.
A laboratory study was conducted of the heterogeneous catalysis of sulfur dioxide at ppm concentrations in air by insoluble particles of CaCO2, V2O5, Fe203, flyash from a coal-burning power plant, MnCO2, activated carbon, and suspended particulate matter from urban air. The investigalion was performed by utilizing a new technique for aerosol stabilization which consists of depositing the aerosol on Teflon beads in a fluidized bed. The Teflon beads with deposited aerosol particles were then packed into a flow reactor. Progress of the chemical reaction of SO2 with deposited particles was continuously monitored by determining the SO2 concentrations in the reactor effluent with a microcoulometer.

In this investigation, CaCOg, V2O5, and flyash were essentially inert to SO2 at room temperature. Fe2O3, activated carbon, MnO2, and suspended particulate matter from urban air sorbed SO2 from air streams with up to 14.4 ppm SO2 in air. Evidence is presented which suggests that a substantial part of the sorbed SO2 was physically adsorbed.

Bioassay procedures which utilize pulmonary flow resistance changes in guinea pigs to monitor response to inhaled SO2-aerosol mixtures in air have indicated the weak or non-potentiating capacity of insoluble aerosols as contrasted to soluble aerosols. Potentiating response of an aerosol appears to be strongly associated with reaction of SO2 in a water droplet containing aerosol ions and not with physically adsorbed SO2 on an insoluble aerosol.  相似文献   

8.
A systematic method for analyzing dioxins (PCDDs, PCDFs and dioxin-like PCBs), hexachlorobenzene (HCB), heptachlor epoxide and beta-hexachlorocyclohexane (HCH) in human milk was developed to determine the residual amount of HCB in human milk and to evaluate the overall toxicity of both dioxins and HCB in human milk. The fractionation behavior of HCB on chromatography with silica gel, alumina, and activated carbon/silica gel, and the concentrated sulfuric acid decomposition method, which is widely used as a dioxin cleanup method, were studied in order to make the preprocessing operation for HCB measurement compatible with that for conventional dioxin measurement. HCB was found to be eluted in the 2% dichloromethane (DCM)/hexane 60 ml fraction from an alumina column. Heptachlor epoxide and a part of beta-HCH were eluted in the 10% DCM/hexane 50 ml fraction from a silica gel column, while the remaining beta-HCH was eluted in the 25% DCM/hexane 60 ml fraction from an activated carbon/silica gel column. Moreover, HCB showed significant correlation with dioxin congeners having high toxicity equivalence factors (TEFs). The results suggest that the exposure route to HCB and its accumulation behavior in the human body are similar to those of the dioxins.  相似文献   

9.
根据滑动弧放电等离子体适于降解高浓度有机物废气的特性,结合活性炭吸附法,提出了吸附器的吸附浓缩和热脱附-等离子体氧化净化有机废气的方法。在活性炭吸附过程中,最初2 h内甲苯净化率达到100%,随着时间的增加净化率下降;在热脱附滑动弧放电等离子体净化过程中,甲苯降解效率最高为97.3%。将滑动弧放电等离子体反应器出口气相产物收集进行FT-IR检测,发现放电后有CO2、CO、H2O和NO2产生,并分析了甲苯的降解机理。  相似文献   

10.
Abad E  Caixach J  Rivera J 《Chemosphere》2003,50(9):1175-1182
This study presents the results of a dioxin abatement programme undertaken in the municipal waste incineration plant of Montcada i Reixac (Barcelona, Spain) after the replacement of an obsolete air cleaning device by a new flue gas treatment system. A number of sampling campaigns were conducted with the aim of characterising stack gas emission levels of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and to evaluate initial specifications of dioxin stack gas emission values below 0.1 ng I-TEQ/Nm(3). Preliminary results revealed levels between 44 and 111 ng I-TEQ/Nm(3) when the gas-cleaning system consisted only of an old electrostatic precipitator (ESP). Decreased levels around 15 ng I-TEQ/Nm(3) were observed when the semi-dry scrubber began to operate and the ESP was switched off. Again, remarkable dioxin removal was observed after the installation of the fabric filter and levels around 0.3-0.4 ng I-TEQ/Nm(3) were soon achieved. Nevertheless, the limit of 0.1 ng I-TEQ/Nm(3) was reached by additional injection of activated carbon which helped to lower PCDD/PCDF levels to around 0.036 ng I-TEQ/Nm(3). The results also demonstrated a significant change in the dioxin distribution present in combustion-derived materials (stack gas emission, bottom ash and solid waste from gas treatment). The major dioxin fraction was found in gaseous matrices before the flue gas control system was upgraded. After this step, the major dioxin fraction content was observed in solid waste from gas treatment.  相似文献   

11.
A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes approximately 1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 10(7) yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octa-chlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Q(f)) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Q(f)/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases < or = 90%.  相似文献   

12.
DNA-based population analysis was applied in combination with Raman spectrometry and Environmental Scanning Electron Microscopy for the characterisation of natural biofilms from sand and activated carbon filters operated for a long term at a municipal waterworks. Whereas the molecular biology polymerase chain reaction combined with denaturing gradient gel electrophoresis approach provides a deeper insight into the bacterial biofilm diversities, Raman spectrometry analyses the chemical composition of the extracellular polymer substances (EPS), microorganisms embedded in EPS as well as other substances inside biofilm (inorganic compounds and humic substances). Microscopy images the spatial distribution of biofilms on the two different filter materials. In addition, bacterial bulk water populations were compared with biofilm consortia using the molecular fingerprint technique mentioned.Population analysis demonstrated the presence of more diverse bacterial species embedded in a matrix of EPS (polysaccharides, peptides, and nucleic acids) on the sand filter materials. In contrast to this, activated carbon granules were colonised by reduced numbers of bacterial species in biofilms. Besides α-, β-, and γ-Proteobacteria, a noticeable specific colonisation with Actinobacteria was found on activated carbon particles. Here, the reduced biofilm formation came along with a decreased EPS synthesis. The taxonomy profiles of the different biofilms revealed up to 60% similarity on the same filter materials and 32% similarity of different materials. Similarity of adherent communities from filter materials and bulk water populations from the filter effluent varied between 36% and 58% in sand filters and 6–40% in granular activated carbon filters.The biofilm investigation protocols are most crucial to subsequent acquisition of knowledge on biofilm dynamics and bacterial contributions to transformation or adsorption processes in waterworks facilities.  相似文献   

13.
Cunliffe AM  Williams PT 《Chemosphere》2006,62(11):1846-1855
The development of an analytical method for the analysis of PCDD/PCDF in flyash using a bench analytical system comprising of a gas chromatograph fitted with an ion trap detector operated in the tandem MS mode is described. The optimum settings for the most important MS/MS parameters are given, including those for the less reported mono- to tri-chlorinated dioxin and furan congener groups. Flyash samples from three waste incineration plants representing a decommissioned 1970s plant design, an upgraded and still operating plant originally designed in the 1970s, and a modern 1990s design operating plant have been analysed for PCDD/PCDF. The flyash samples were analysed for PCDD/PCDF using the methods developed and the total PCDD/PCDF, I-TEQ values and isomeric profiles are reported. The flyash from the older decommissioned incinerator had very significantly higher concentrations of PCDD/PCDF compared to the modern incinerator flyash.  相似文献   

14.
刘阳  张燕 《环境工程学报》2012,6(11):3822-3826
以嘉兴市某水厂沉后水为进水进行实验,研究炭砂滤池对污染物的去除性能,以及炭砂滤池取代活性炭+砂滤池的可能性,探讨了短流程工艺的适用性。结果表明,炭砂滤池能有效去除水中的浊度、氨氮、CODMn和铁、锰等污染物,与活性炭柱相比,炭砂滤池在降低出水浊度和水中颗粒数方面具有一定优势,即砂垫层对控制出水浊度和保障微生物安全能够起到积极作用。在实验条件下,增加活性炭层厚度或者降低滤速,在一定程度上有利于提高对CODMn的去除率。在设计滤速为9~10 m/h,CODMn〈4.5 mg/L时,可直接以炭砂滤池取代活性炭池+砂滤池,仍然能保证出水CODMn〈3 mg/L。  相似文献   

15.
The dioxin removing capacity of the shell dedioxin system (SDDS-a Ti/V oxidative type catalyst) has been tested using the Ume? lab-scale incinerator over the temperature range 100-230 degrees C and at space velocities of 8000 and 40,000 h(-1). Other analogous organic compounds, such as PCBs, PAHs, chlorobenzenes and chlorophenols have also been investigated. Results show a high degree of dioxin removal already at 100 degrees C (82%), which occurs mainly by adsorption. When the temperature is raised a transition towards destruction is seen and at 150 degrees C, gas hour space velocity (GHSV) 8000 and at 230 degrees C, GHSV 40,000 virtually all removal is by destruction. High PCDD/F destruction efficiencies are reported (> 99.9%, based on I-TEQ); the other dioxin-related species and PAHs are also removed and destroyed to a significant extent. The SDDS has proved to be an effective means of destroying organic compounds in the gas phase, particularly dioxins, at temperatures as low as 150 degrees C.  相似文献   

16.
实验通过对传统臭氧-生物活性炭工艺的调整,采用臭氧-曝气生物活性炭滤池-砂滤池工艺,对比研究了4mm柱状炭、4 mm破碎炭和1.5 mm柱状炭3种不同类型活性炭用于给水深度处理的运行效果。结果表明,粒径为1.5 mm的柱状炭对有机物和氨氮的去除效果以及出水浊度方面优于其他2种活性炭,但炭滤池水头损失偏大,且不够稳定,适当增加柱状炭的粒径可稳定和降低滤池的水头损失。  相似文献   

17.
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

18.
The objective of this research was to measure the initial effective cleaning rates (ECRs) of selected air cleaners for removing nitrogen dioxide (NO2) and six representative volatile organic compounds (VOC) from air. Four portable air cleaners, representing different principles of particle removal and incorporating activated carbon, were investigated. Experiments were conducted in a closed room-size environmental chamber using analyte concentrations similar to those reported in residences. Effects of relative humidity, temperature, filter particle loading and saturation of the adsorbents on the ECRs were not investigated in this preliminary study. However, the effect of extended usage was investigated for one air cleaner.Two of the air cleaners were found to be reasonably effective initially in removing NO2 and five of the six VOC. These two devices had relatively high flow rates and the greatest amounts of activated carbon. None of the devices removed dichloromethane, the VOC with the highest vapor pressure. One air cleaner emitted 1,1,1-trichloroethane and formaldehyde. After being used in a residence for 150 h, the ECRs for the air cleaner which had the highest initial values decreased to 50% or less of the initial ECRs. This use was only about 15% of the recommended filter lifetime. Conversion of NO2 to NO was also observed for this device but only after it had been used in the residence.  相似文献   

19.
A method involving supercritical fluid extraction (SFE) with a solid phase trap containing activated alumina was investigated for the rapid analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin like polychlorinated biphenyls (DL-PCBs) in soils and sediments. The samples were extracted by using supercritical carbon dioxide with water (2% versus CO(2) flow velocity) being used as an entrainer at a pressure of 30 MPa and a temperature of 130 degrees C for 50 min. The extracts were adsorbed on an activated alumina trap that was maintained at a temperature of 150 degrees C, and then, PCDD/DFs and DL-PCBs were eluted with 20 ml of hexane at 60 degrees C. After concentration, they were measured with a high-resolution gas chromatograph interfaced to a high-resolution mass spectrometric detector. The average concentrations of PCDD/DFs and DL-PCBs corresponded to the results obtained by the conventional method, and the reproducibility of this SFE method was below 21% of the relative standard deviations for all samples. The total time required for the analysis of the pretreatment of this method was only 2 h.  相似文献   

20.
微波法制备污泥活性炭研究   总被引:4,自引:0,他引:4  
采用微波加热法,以污水厂剩余污泥为原料,磷酸为污泥活化剂制备污泥活性炭.微波功率、辐照时间和磷酸浓度对污泥活性炭吸附性能具有显著影响,在最佳工艺条件微波功率480 W、辐照时间315 s和磷酸浓度40%条件下制得的活性炭碘值301 mg/g,比表面积168 m2/g,污泥中重金属绝大部分被固化.与传统商品炭相比,污泥炭孔隙结构以中孔为主.利用该活性炭处理城市生活污水处理厂出水,COD去除率可达87%以上,污泥炭的吸附等温线用Langmuir等温吸附模型进行描述.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号