首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

In practice, biofilters are often conceived as entire, single-unit systems. However, the activity of a biofilter varies greatly over its depth. For a given period, each stage of the biofilter dominates ethylbenzene removal. Ethylbenzene was continuously removed in a mixed-medium biofilter. The overall removal efficiency of the ethylbenzene ranged from 70% to greater than 99%. In the upflow biofilter, the most dominant ethylbenzene degrading stage shifted consecutively from the bottom to the top of the reactor. Average water content throughout the biofilter media was relatively consistent. However, the water content of each stage fluctuated dramatically and was correlated with the ethylbenzene removal rate. Without any water addition, the biofilter was operated for 62 days above the target removal efficiency of 80%. A 9-month slow-release fertilizer, mixed with composting media, was an effective way to eliminate the nutrient deficiency in the biofilter operation.  相似文献   

2.
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system.  相似文献   

3.
A comparison of biodegradation efficiencies was done for volatile benzene, toluene, ethylbenzene, m-xylene, p-xylene, and o-xylene elimination in a compost biofilter. The column was first exposed to a synthetic mixture and then a free phase product mixture containing these compounds at increasing pollutant loads. The optimal moisture content of the system was determined, and this was used in the biodegradation experiments. An acclimated culture was used as an inoculum for the biofilter, the matrix of which consisted of composted forestry products, composted sewage sludge, lime, and perlite. Inlet and outlet concentrations were measured, and pollutant loads, elimination capacities, and removal efficiencies were determined for each of the compounds. Optimal moisture content for this system was found to be 40%, and the short lag times (one to five days) in acclimating to the compounds was ascribed to the presence of the well-acclimated inoculum. The compounds in the synthetic mixture had higher removal efficiencies (80-99%) even at the higher pollutant loads experienced, with the exception of o-xylene. Dynamic removal efficiencies and acclimation periods were seen in the free phase product mixture, with a removal efficiency range from 70 to 95%. This was attributed to the presence of chlorinated aliphatics in the free phase product.  相似文献   

4.
管式生物过滤器去除乙苯废气   总被引:1,自引:0,他引:1  
生物过滤由于其良好的成本效益和环境友好性已经成为控制挥发性有机化合物(VOCs)含量和气味气体排放的常规技术。营养物质的均匀分布、生物膜和介质床内的气体流是成就一个性能优良的生物过滤器至关重要的因素。而由本实验室开发的管式生物过滤器(TBFs)已被证明具备此优势。本实验的管式生物过滤器以聚氨酯海绵作为填料,研究在不同有机负荷、气体停留时间(EBCT)、进气量和表面活性剂等条件下乙苯废气的去除效率(RE)。实验同时记录了管式生物过滤器启动阶段的表现。初期使附着在填料上的微生物暴露在浓度为40 mg/m3的乙苯废气中40 d,此时的气体停留时间为15 s,使微生物慢慢适应并逐步降解乙苯废气;然后连续地控制管式生物过滤器的入口乙苯浓度为40、80、120和160 mg/m3,以使有机负荷逐步升高。结果表明,乙苯去除效率随着有机负荷的增大而逐步减小。当气体停留时间从15 s增加到30 s和60 s,而有机负荷控制在38.60 g/(m3·h)时,乙苯废气去除效率略微增加。此外,随着进气量的增大乙苯废气的最大平均去除效率有所下降而此时的降解容量增大,这个过程中乙苯进气浓度保持不变。结果还表明,在营养液中加入聚乙二醇辛基苯基醚这种表面活性剂可以提高乙苯废气的去除效率。  相似文献   

5.
A technique is presented that can be used to estimate the changes in physical structure in a natural biofilter packing medium, such as compost, over time. The technique applies information from tracer studies, grain size distribution, and pressure drop analysis to a model that estimates the number of channels, average channel diameter, number of particles, and specific surface area of the medium. Important operational factors, such as moisture content, pressure drop, and sulfate accumulation also were evaluated both in a conventionally operated biofilter and in one operated with periodic compost mixing. In the conventionally operated laboratory-scale compost biofilter, hydrogen sulfide (H2S) removal efficiency decreased from 100% to approximately 90% over 206 days of operation. In a similar system, operated with compost mixing, the H2S removal efficiency was maintained near 100%. Variations in media moisture conditions and specific surface area can explain the results observed in this study. Under conventional operation, drying near the inlet disintegrated the compost particles, producing a large number of particles and flow channels and increasing the specific surface area. At the top of the column, where moisture was added, particle size increased and specific surface area decreased. In the column with media mixing, moisture content, particle size, and specific surface area remained homogeneous.  相似文献   

6.
The system performance of a trickle bed biofilter for treating single and mixed benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors from waste gases was investigated under different gas flow rates and influent BTEX concentrations. When a single substrate was fed, removal efficiencies of greater than 90% could be achieved for the loads below 64 g benzene/m3/hr, 110 g toluene/m3/hr, 53 g ethylbenzene/m3/hr, and 55 g o-xylene/m3/hr. When a mixed substrate was fed, removal efficiencies of each compound could be above 90% at BTEX loads below 96 g/m3/hr. The trickle bed biofilter appears to be an effective treatment process for removing both single and mixed BTEX vapors with low to high loads. Under similar substrate loads, BTEX vapors were preferentially biodegraded in the order of toluene, benzene, o-xylene, and ethylbenzene. The volumetric removal rates (elimination capacities) of BTEX vapors for a single-substrate feed were higher than those for a mixed-substrate feed under similar substrate loads; these differences were enhanced at higher substrate loads and less significant for a preferred substrate.  相似文献   

7.
Biofiltration of gasoline vapor by compost media   总被引:2,自引:0,他引:2  
Gasoline vapor was treated using a compost biofilter operated in upflow mode over 4 months. The gas velocity was 6 m/h, yielding an empty bed retention time (EBRT) of 10 min. Benzene, toluene, ethylbenzene and xylene (BTEX) and total petroleum hydrocarbon (TPH) removal efficiencies remained fairly stable approximately 15 days after biofilter start-up. The average removal efficiencies of TPH and BTEX were 80 and 85%, respectively, during 4 months of stable operation. Biodegradation portions of the treated TPH and BTEX were 60 and 64%, respectively. When the influent concentration of TPH was less than 7800 mg TPH/m3, approximately 50% of TPH in the gas stream was removed in the lower half of the biofilter. When the influent concentration of BTEX was less than 720 mg BTEX/m3, over 75% of BTEX in the gas stream was removed in the lower half of the biofilter. Benzene removal efficiency was the lowest among BTEX. A pressure drop could not be detected over a 1-m bed height at a gas velocity of 6 m/h after approximately 4 months of operation. Results demonstrated that BTEX in gasoline vapor could be treated effectively using a compost biofilter.  相似文献   

8.
Biofilters are becoming an increasingly popular treatment device for odors and other volatiles found at wastewater treatment plants. A seashell media based biofilter was installed in April 2011 at Lake Wildwood Wastewater Treatment Plant located in Penn Valley, California. It was sampled seasonally to examine its ability to treat odorous compounds found in the air above the anaerobic equalization basin at the front end of the plant and to examine the properties of the biofilter and its recirculating water system. The odor profile method sensory panels found mainly sulfide odors (rotten eggs and rotten vegetable) and some fecal odors. This proved to be a useful guidance tool for selecting the required types of chemical sampling. The predominant odorous compounds found were hydrogen sulfide, methyl mercaptan and dimethyl sulfide. These compounds were effectively removed by the biofilter at greater than 99% removal efficiency therein reducing the chemical concentrations to below their odor thresholds. Aldehydes found in the biofilter were below odor thresholds but served as indicators of biological activity. Gas chromatography with mass spectrometry and gas chromatography with sensory detection showed the presence of dimethyl disulfide and dimethyl trisulfide as well, but barely above their respective odor thresholds. The neutrality of the pH of the recirculating water was variable depending on conditions in the biofilter, but a local neutral pH was found in the shells themselves. Other measurements of the recirculating water indicated that the majority of the bio-activity takes place in the first stage of the biofilter. All measurements performed suggest that this seashell biofilter is successful at removing odors found at Lake Wildwood. This study is an initial examination into the mechanism of the removal of odorous compounds in a seashell biofilter.

Implications:?This paper presents a thorough examination of a seashell media biofilter, a sustainable treatment technology used to remove reduced sulfide compounds. The durable performance of the seashell biofilter ensures that odors will be adequately controlled, preventing odor nuisance to surrounding residences, which is an emerging problem faced by waste management facilities. The odor profile method technique used in this study can be applied in many situations by waste management facilities and regulatory air management organizations for source tracking in relation to prevention and management of odor complaints, respectively.  相似文献   

9.
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon(-1). Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (approximately 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.  相似文献   

10.
Abstract

A laboratory-scale compost-based biofilter was operated over a six-month period to study the requirements for removal of n-hexane from air. Hexane is a relatively short chain aliphatic hydrocarbon with a high Henry's coefficient and a low water solubility. Acclimation of the biofilter was slow, but removal efficiencies around 80% were achieved after one month of operation. However, performance decreased during the next two months of operation to 50% removal efficiency. Nutrient limitation was proposed as a reason for the decrease in reactor performance. After the addition of a concentrated nitrogen solution, reactor performance increased almost immediately to >99%. Removal efficiency remained above 99% for the following two months of operation at inlet concentrations of 0.7 g/m3 (200 ppmv), at superficial bed velocities approaching 50 m/h, and empty bed residence times of about one minute. Thus, nutrient availability may well limit biofilter performance even in compost- based units. It was shown that nutrients can be added effectively in a soluble form if compost quality is poor and a method is proposed for the evaluation of compost quality.  相似文献   

11.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

12.
Yuan C  Weng CH 《Chemosphere》2004,57(3):225-232
The objectives of this research are to investigate the remediation efficiency and electrokinetic behavior of ethylbenzene-contaminated clay by a surfactant-aided electrokinetic (SAEK) process under a potential gradient of 2 Vcm(-1). Experimental results indicated that the type of processing fluids played a key role in determining the removal performance of ethylbenzene from clay in the SAEK process. A mixed surfactant system consisted of 0.5% SDS and 2.0% PANNOX 110 showed the best performance of ethylbenzene removed in the SAEK system. The removal efficiency of ethylbenzene was determined to be 63-98% in SAEK system while only 40% was achieved in an electrokinetic system with tap water as processing fluid. It was found that ethylbenzene was accumulated in the vicinity of anode in an electrokinetic system with tap water as processing fluid. However, the concentration front of ethylbenzene was shifted toward cathode in the SAEK system. The electroosmotic permeability and power consumption were 0.17 x 10(-6)-3.01 x 10(-6) cm(2)V(-1)s(-1) and 52-123 kW h m(-3), respectively. The cost, including the expense of energy and surfactants, was estimated to be 5.15-12.65 USD m(-3) for SAEK systems, which was 2.0-4.9 times greater than that in the system of electrokinetic alone (2.6 USD m(-3)). Nevertheless, by taking the remediation efficiency of ethylbenzene and the energy expenditure into account for the overall process performance evaluation, the system SAEK was still a cost-effective alternative treatment method.  相似文献   

13.
Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppm(v)), methyl ethyl ketone (12 ppm(v)), toluene (29 ppm(v)), ethylbenzene (10 ppm(v)), and p-xylene (10 ppm(v)). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m(-3) hr(-1) and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were, more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

14.
采用厌氧/射流充氧生物滤塔/人工湿地组合工艺处理农村生活污水,考察了组合工艺及其各处理单元对污染物去除的贡献率。在实验室进行了小试,实验结果表明:该组合工艺对污染物具有较好的去除效果,在稳定工况下,组合工艺对COD、NH4+-N、TN和TP的平均去除率分别为85.4%、74.5%、75.9%和78.3%。生物滤塔能有效...  相似文献   

15.
复合生物滤池处理H2S和NH3的挂膜与工艺条件   总被引:3,自引:1,他引:3  
采用复合生物滤池(生物滴滤池 生物过滤池)处理H2S和NH3组成的混合恶臭气体,填料分别为经表面改性的天然斜发沸石和木屑.实验研究了该工艺的驯化挂膜情况和主要工艺条件,结果表明,天然斜发沸石和木屑改性后,驯化挂膜周期为10~14 d,比文献中颗粒活性炭挂膜缩短14~18 d.复合生物滤池的最佳工艺条件为:高度120 cm,循环液流量4.56 L/h.同时,生物滴滤池处理水溶性好的NH3气体效果较生物过滤池好,而生物过滤池处理水溶性差的H2S气体较生物滴滤池好.因此,复合生物滤池可用于处理不同水溶性的混合恶臭气体.  相似文献   

16.
Abstract

Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media.  相似文献   

17.
Trickle-bed air biofilters (TBABs) are suitable for treating volatile organic compounds (VOCs) at a significantly high practical loading because of their controlled environmental conditions. The application of TBAB for treating styrene-contaminated air under periodic backwashing and cyclical nonuse periods at a styrene loading of 0.64-3.17 kg chemical oxygen demand (COD)/m3 x day was the main focus of this study. Consistent long-term efficient performance of TBAB strongly depended on biomass control. A periodic in situ upflow with nutrient solution under media fluidization, that is, backwashing, was approached in this study. Two different nonuse periods were employed to simulate a shutdown for equipment repair or during weekends and holidays. The first is a starvation period without styrene loading, and the second is a stagnant period, which reflects no flow passing through the biofilter. For styrene loadings up to 1.9 kg COD/m3 x day, removal efficiencies consistently above 99% were achieved by conducting a coordinated biomass control strategy, that is, backwashing for 1 hr once per week. Under cyclical nonuse periods for styrene loadings up to 1.27 kg COD/m3 x day, stable long-term performance of the biofilter was maintained at more than 99% removal without employing backwashing. No substantial impact of nonuse periods on the biofilter performance was revealed. However, a coordinated biomass control by backwashing subsequently was unavoidable for attaining consistently high removal efficiency at a styrene loading of 3.17 kg COD/m3 x day. As styrene loading was increased, reacclimation of the biofilter to reach the 99% removal efficiency following backwashing or the nonuse periods was delayed. After the non-use periods, the response of the biofilter was a strong function of the biomass in the bed. No significant difference between the effects of the two different nonuse periods on TBAB performance was observed during the study period.  相似文献   

18.
A laboratory-scale biofiltration system, the rotatory-switching biofilter (RSB), was operated for 199 days using toluene as a model pollutant. The target gaseous pollutant for the biofiltration experiment was approximately 300 ppmv of toluene. Toluene removal efficiency (RE, %) was initially approximately 20% with a 247-ppmv concentration (0.9 g m(-3)) of toluene during the first 10 days. Although the RE decreased several times whenever nitrogen was consumed, it again reached almost 100% when the nitrogen source was in sufficient supply. Denaturing gradient gel electrophoresis (DGGE) analysis was employed to assess the transformation ofmicroflora during operation of the biofilter The results based on a 16S rRNA gene profile showed that the microbial community structure changed with operation time. Although the microflora changed during the initial period (before day 40), transformation of the bacterial component was hardly observed after day 51. Statistical analyses of the DGGE profiles indicated that the bacterial community was almost unaffected by the environmental factors, such as adding ozone, high-level nitrogen supply, increase of loading toluene, and the shutdown of the RSB. The DGGE profile using tmoA-like genes, which encode proteins belonging to the hydroxylase component mono-oxygenases involved in the initial attack of aerobic benzene, toluene, ethylbenzene, and xylene degradation, confirmed the existence of toluene-degrading bacteria. There were at least four kinds of toluene-degradable bacteria having tmoA-like genes up to day 36, which decreased to two species after day 40. Sequence analysis after DGGE profiling revealed that Burkholderia cepacia, Sphingobacterium multivorum, and Pseudomonas putida were present in the biofilter. Only Alicycliphilus denitrificans was present throughout the whole operation period. In the initial stage of operating the RSB, many types of bacteria may have tried to adapt to the conditions, and subsequently, only selected bacteria were able to grow and to degrade toluene.  相似文献   

19.
Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.  相似文献   

20.
Abstract

Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppmv), methyl ethyl ketone (12 ppmv), toluene (29 ppmv), ethylbenzene (10 ppmv), and p-xylene (10 ppmv). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m?3 hr?1 and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号