1.
Liu HM  Lu SY  Buekens AG  Chen T  Li XD  Yan JH  Ma XJ  Cen KF 《Chemosphere》2012,86(3):300-307
In order to determine the baseline contamination by polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in different areas in China, prior to the construction of municipal solid waste incinerators (MSWIs), a total of 32 representative soil samples was collected near 16 incinerators and analyzed for their PCDD/F concentrations. The PCDD/F baseline concentrations in the soil samples ranged from 0.32 to 11.4 ng I-TEQ kg−1 (dry matter), with average and median value of 2.73 and 2.24 ng I-TEQ kg−1 (dry matter), respectively, and a span between maximum and minimum recorded value of 36. The PCDD homologues predominated in 26 out of 32 soil samples, with the ratio (PCDDs)/(PCDFs) ranging from 1.1 to 164; however in the other 6 samples, PCDF homologues were larger, with the same ratio varying from 0.04 to 0.8. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) were used to examine PCDD/F amount and profile in these soil samples, and their possible associations with known emission sources: in this process 6 really distinct isomer fingerprints were identified. Background PCDD/F levels and profiles were comparable to those found in soils from China and other countries and indicate a rather low baseline PCDD/F contamination of soils. The present data provide the tools for future assessment of a possible impact of these MSWIs.  相似文献   

2.
Medium- and low-volatile organic chlorine (M/LVOCl) and PCDD/Fs in flue gas from various municipal waste incinerators (MWIs) were monitored. The sample for M/LVOCl was collected in an adsorption tube which was thermally desorbed and the amount of chlorine was measured by atomic emission spectrometry (AES) detection using radiofrequency helium plasma. The helium plasma excited chlorine having an optical emission line of 837.6 nm was monitored. The MVOCl and LVOCl were organic chlorine groups whose boiling points (bp) ranged from 70-120 degrees C and 170-270 degrees C, respectively. The compounds having bp 120-170 degrees C were distributed in two tubes. LVOCl correlated well with PCDD/Fs (ng/Nm3, r=0.81) in a wide range of 0.01-100 ng/Nm3 of PCDD/Fs, while the correlation of LVOCl vs. TEQ was less related (r=0.69). These results agreed with the fact that LVOCl monitored the amount of organic chlorine without molecular structure information, which is critical to toxicity. Since the bp of LVOCl was not identical with that of PCDD/Fs, the regression was effected by the conditions of the gas treatment devices. Because most data of 2001 were collected just after the installation of PCDD/Fs in MWIs, the regression of 2001 was slightly different from that of 2002-2003. Eliminating these initial unsteady data, the regression of LVOCl vs. PCDD/Fs became better, giving r= 0.86. Besides having PCDD/Fs as surrogates, M/LVOCl is valuable as a versatile element-selective organic chlorine monitor to improve thermal process control.  相似文献   

3.
In the context of two Environmental Health Surveillance Programs, launched in response to public and scientific concern in relation to waste incinerators located near Lisbon and in Madeira Island, two human biomonitoring projects have been started in Portugal, focussed in dioxins and dioxin-like compounds in human milk. Results from the undertaken studies have already provided data on the extent and pattern of dioxin body burden of both studied groups as well as a preliminary temporal trend of dioxin levels for the population residing near Lisbon incinerator. The present paper investigates difference between exposed and non-exposed subjects under study and, from a preventive perspective, possible covariates of the dioxin levels in human milk. Emissions from both incinerators appear to be well controlled as there is no increase of human body burden of dioxins as measured in human milk of individuals living near these facilities. Concerning other determinants of dioxin levels, results suggest confirmation of previously found significant age-dependent trend towards higher levels of dioxins in aged subjects. On the contrary, association between mother's levels of dioxins and parity lost significance. Apart from the issue of incineration, the general conclusion for the general population is that living in Lisbon as compared to Madeira results in higher milk dioxin levels and possible health risks. The profile of the single congeners for PCDD/Fs in human milk from Madeira and Lisbon shows similar contributions for 12378-PCDD, 23478-PCDF, 123678-HCDD and 2378-TCDD, that account altogether for about 84% of the total identified dioxin body burden in the studied groups.  相似文献   

4.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

5.
Fly ash from municipal solid waste incinerators (MSWIs) has been characterized in terms of polychlorinated dibenzyl-p-dioxin and polychlorinated dibenzofuran (PCDD/F) content. Increasing values of PCDD/Fs have been found to correlate with decreasing temperatures of sampling points in flue gas treatment lines of the plants, confirming other researchers' findings about temperature as the major controlling parameter for the PCDD/F formation. Measured PCDD/F ratios show that de novo synthesis is the dominant formation mechanism. The increasing trends of particulate-bound PCDD/Fs can be explained not only through the dominant de novo synthesis process but also considering the adsorption of gaseous PCDD/Fs on fly ash deposits, even outside the typical de novo synthesis temperature ranges. The effective role of a post-combustor unit, imposed by Italian law to destroy PCDD/ Fs, also needs to be carefully reconsidered.  相似文献   

6.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

7.
Municipal solid waste incinerator (MSWI) operators frequently have expressed the need for an indirect indication of the expected production of PCDD/F and associated abatement procedures through a possible correlation with other real-time data, through using marker pollutants (e.g., penta/hexachlorinated aromatics), or through other indications. Since real-time measurement of PCDD/F is impossible, a correlation of PCDD/F emissions with other operating parameters could help in achieving these goals. Literature data of large-scale MSWIs concerning these correlations are scarce and seldom conclusive. Extensive data of Flemish MSWIs are used to statistically assess possible correlations of PCDD/F and other operating parameters. The effect of temperature in the electrostatic precipitator (ESP) is of major importance. When converting values measured between 180 and 270 degrees C to a reference temperature of, for example, 230 degrees C, PCDD/F concentrations achieve nearly constant values, stressing that the major correlating parameter is the temperature of the ESP. High temperatures that enhance de novo synthesis should be avoided.  相似文献   

8.
Huang H  Buekens A 《Chemosphere》2001,44(6):1505-1510
A kinetic model is developed for de novo synthesis of PCDD/F from carbon in incinerator fly ash. The main mechanistic steps considered in the model are carbon gasification, PCDD/F formation, desorption and degradation. Rate equations are derived which can relate PCDD/F formation with process variables including carbon concentration of fly ash, partial pressure of oxygen, reaction temperature and time. The kinetic model has been verified using laboratory de novo synthesis data reported in the literature. When the model is applied to industrial incinerator conditions, PCDD/F formation levels of 0.1-0.5 microg/N m3 in the gas phase and 0.1-1.2 microg/g in the solid phase are calculated, and both are in good agreement with incinerator measurements.  相似文献   

9.
Wang HC  Hwang JF  Chi KH  Chang MB 《Chemosphere》2007,67(9):S177-S184
The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).  相似文献   

10.
对中国典型的小型焚烧设施现状和二噁英类排放进行了初步调查研究,未经处理的小型垃圾焚烧设施烟气中二噁英类毒性当量(TEQ)大于6 ng/m3,小型火化机烟气中二噁英类TEQ大于5 ng/m3.设计并检验了布袋除尘器和活性炭滤布的二噁英类去除效果.仅使用布袋除尘器二噁英类去除率不高,布袋除尘器和活性炭滤布联用可以有效去除飞灰和气相中的二噁英类,去除率达到90%左右,可达到《生活垃圾焚烧污染控制标准》(GB 18485-2001)二噁英类排放标准.  相似文献   

11.
Choi KI  Lee DH  Osako M  Kim SC 《Chemosphere》2007,66(6):1131-1137
Wet scrubber is one of the most conventional types of air pollutant control devices (APCDs), which is specially designed to treat dust and acidic gases in the flue gas simultaneously. In spite of its outstanding ability to control them, however, wet scrubbers have been considered as potential contaminant sources that may increase PCDD/DF concentrations in the flue gas. In this study, we investigated the change of PCDD/DF concentrations at the inlets and outlets of seven wet scrubbers, and compared them with other published data. With a multi-regression analysis of dust concentrations and temperature at the inlets and outlets of given wet scrubbers, we developed an empirical model to understand factors dominating the change of PCDD/DF concentrations. As a result, we confirmed that the changes of PCDD/DF concentrations in wet scrubbers are closely related to their concentrations at the inlets, which would usually be determined by the type of APCDs installed upstream of the wet scrubber.  相似文献   

12.
Bulk depositions and surface soil were collected in a suburban area, near the Adriatic Sea, in order to assess the contribution of a municipal solid waste incinerator to the area’s total contamination with polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs and PCDFs). Samples were collected at two sites, situated in the area most affected by plant emissions (according to the results of the Calpuff air dispersion model), and at an external site, considered as a reference. Results show that the studied area is subject to low contamination, as far as these compounds are concerned. Deposition fluxes range from 14.3 pg m−2 d−1 to 89.9 pg m−2 d−1 (0.75 pg-TEQ m−2 d−1 to 3.73 pg-TEQ m−2 d−1) and no significant flow differences are observed among the three monitored sites. Total soil concentration amounts to 93.8 ng kg−1 d.w. and 1.35 ng-TEQ kg−1 d.w, on average, and confirms a strong homogeneity in the studied area. Furthermore, from 2006 to 2009, no PCDD/Fs enrichment in the soil was noticed. Comparing the relative congener distributions in environmental samples with those found in stack emissions from the incineration plant, significant differences are observed in the PCDD:PCDF ratio and in the contribution of the most chlorinated congeners. From this study we can conclude that the incineration plant is not the main source of PCDD/Fs in the studied area, which is apparently characterized by a homogeneous and widespread contamination situation, typical of an urban area.  相似文献   

13.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

14.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

15.
H. Vogg  L. Stieglitz 《Chemosphere》1986,15(9-12):1373-1378
The effect of thermal treatment of fly ash on the behaviour of PCDD/PCDF was studied in the range between 120 and 600° C. Annealing at 300° C (2 hrs) resulted in an increase of PCDD/PCDF concentration by a factor of 10 to 15. At 600° C degradation to concentrations below 0.1 ng/g is observed.  相似文献   

16.
Modeling the formation of PCDD/F in solid waste incinerators   总被引:1,自引:0,他引:1  
Stanmore BR 《Chemosphere》2002,47(6):565-573
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) appear in unacceptable amounts in the gaseous emissions during the incineration of wastes containing significant quantities of chlorine and metals, such as MSW and medical waste. They are formed both in the gas phase at temperatures above 600 degrees C and on the surface of the solid phase (flyash) in the temperature range 400-225 degrees C. Both the precursor (from existing smaller chlorinated molecules) and de novo (from elemental carbon) routes are involved. An empirically derived global model for their de novo formation on flyash in MSW and medical waste incinerators has now been extended to include the precursor mechanism, and a gas phase formation component, with separate rate expressions for PCDD and PCDF. Homogeneous PCDD formation is governed by the concentration of chlorophenols and PCDF by that of chlorophenols and chlorobenzenes. The result is more complete system which distinguishes between the gas and solid phase contributions to the I-TEQ. An additional step for the adsorption of gaseous PCDD/F back onto the solid phase during cooling suggests this should be minimal in the gas ducts of an incinerator. The extended model has been tested against experimental data collected from a well-controlled pilot incinerator and commercial incinerators, and found to adequately describe the measured outputs. With the model it should be possible to predict the PCDD/F emissions from commercial incinerators, provided that the ash properties and the overall temperature-time profiles are known.  相似文献   

17.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二(口恶)英同类物的含量及其毒性当量.结果表明,产生的二(口恶)英主要存在于飞灰中,烟气中的含量很少.飞灰中二(口恶)英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二(口恶)英的浓度之和与毒性当量之和分别为0.34 ng/m3和0.02 ng/m3,而布袋除尘器前的烟尘和烟气中二(口恶)英的浓度之和与毒性当量之和分别为40.78 ng/m3和3.01ng/m3.飞灰和烟尘中2,3,7,8位氯取代二(口恶)英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二(口恶)英同类物的分布差别较大.通过了解有毒二(口恶)英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二(口恶)英的排放量,减少垃圾焚烧对环境的污染.  相似文献   

18.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

19.
采用溴代二噁英和呋喃(PBDD/F)的高分辨气相色谱/质谱联用(HRGC/HRMS)检测分析方法,对不同类型的焚烧炉(医疗废物焚烧炉、炉排炉生活垃圾焚烧炉、工业废物焚烧炉和流化床生活垃圾焚烧炉)飞灰进行了PBDD/Fs的分布特性分析.结果表明:(1)所有样品中均没有发现六溴代二噁英和呋喃,主要都以四、五溴代二噁英和呋喃...  相似文献   

20.
The aim of this study was to measure, 6 years after regular operations, the concentrations of a number of organic substances in blood and urine of 19 workers employed at a hazardous waste incinerator (HWI) in Spain, and to establish the temporal variation with respect to baseline data and previously performed surveys. This facility was the first, and so far the only HWI in that country. The levels of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB 28, 52, 101, 138, 153 and 180) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were analyzed in six composite plasma samples, while concentrations of di-, tri, and pentachlorophenols, as well those of 1-hydroxypyrene were measured in the urine of these workers. The current mean PCDD/F concentration, 10.4 ng I-TEQ/kg lipid, was significantly lower than that found in the baseline survey, 26.7 ng I-TEQ/kg lipid and similar to that found in the previous (2004) study (7.7 ng I-TEQ/kg lipid). PCDD/F levels in plasma were similar or even lower than those recently reported for various non-exposed populations. For the remaining analyzed substances in plasma and urine, there was not any significant increase in comparison with the levels found in the baseline survey. On the other hand, no marked differences between the concentrations of organic substances in plasma or urine were found according to the respective workplace (plant, laboratory and administration). The results of the present survey indicate that after 6 years of regular operation, the workers at the HWI are not occupationally exposed to PCDD/Fs and other organic substances in their workplaces.  相似文献   