首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aims of the present study were to investigate the metal contents of sediments of several creeks that discharged into coastal waters using the Risk index. This study was carried out in eight creeks in Mahshahr coastal waters in the Northwest of Persian Gulf from October 2005 to November 2006. Superficial sediments were collected seasonally by Peterson grab, and the concentrations of heavy metals were measured by using a voltammetric polarographic method. The range and the mean concentrations obtained in ppm were 15.03–35.16 (27.01) for Cu, 65.57–171.41 (102.67) for Ni, 4.63–20.06 (13.22) for Co, 0.093–0.78 (0.22) for Hg, 65.07–379 (113.70) for Zn, 0.27–1.00 (0.56) for Cd and 7.09–29.72 (14.66) for Pb. To evaluate the levels of sediment contamination, the background values of the different heavy metals were calculated, and the contamination factor for each metal and the degree of contamination for each creek were determined as well. The results show that some elements such as Hg, Zn, and Ni are at risk level, and all of the studied creeks are classified as undergoing a moderate degree of pollution except for Ghannam that showed a considerable degree of contamination. According to the Risk index values, based on sedimentological toxic factors (St) of each metal and the BIO Production Index (BPI) in the studied area, the creeks were classified as considerable and with a very high level of ecological risk.  相似文献   

2.
水中可吸附有机氯(AOCl)的测定——离子色谱法   总被引:1,自引:1,他引:1  
采用自制的燃烧装置,使吸附在活性炭上的有机氯定量地转化为无机氯,经硼砂双氧水溶液吸收,用离子色谱法分离测定。当富集水样的体积为50~200ml时,可测定可吸附有机氯(AOCl)的范围为28~1000μg/L。当样品中AOCl含量在16~64μg时,平均加标回收率大于90%,相对标准偏差小于10%。用该方法还可同时测定水中可吸附有机硫。  相似文献   

3.
2-(2-吡啶偶氮)-间苯二酚固相萃取光度法测定镉的研究   总被引:1,自引:0,他引:1  
研究了用2-(2-吡啶偶氮)-间苯二酚(PAR)固相萃取光度法测定镉,在pH=8 0的硼酸-氢氧化钠缓冲介质中,TritonX-100存在下,QAMDHB与镉反应生成2∶1稳定络合物,体系最大吸收波长为520nm,摩尔吸光系数 =5 18×104L·mol-1·cm-1。样品中的镉用强阴离子交换固相萃取柱固相萃取预分离和富集后,用该方法测定,结果令人满意。  相似文献   

4.
在混合稳定剂的存在下,利用BaSO4的比浊法测定氢氟酸中的SO42-。SO42-浓度在0—50mg/L保持线性,2 5 工作曲线和灵敏度SO42-形成稳定的相应盐类。最低检出量为1mg/L。该方法已用于实际样品的测定。按实验方法测定其吸光度,SO42-的质量浓2 2 酸度的控制  相似文献   

5.
研究了2-(2-喹啉偶氮)-4,5-二甲基苯酚(QADMP)与铜(Ⅱ)的显色反应,在pH为4 0的HAc-NaAc缓冲介质中,CTMAB存在下,QADMP与铜(Ⅱ)生成分子比为2∶1的稳定红色配合物,该配合物λmax=561nm,摩尔吸光系数ε为4 56×104L·mol-1·cm-1,铜(Ⅱ)含量在0~0 4mg/L内符合比耳定律,该方法用于水样中微量铜的测定,结果满意。  相似文献   

6.
研究了用1-(2,6-二氯-4-硝基苯)-3-(4-硝基苯)-三氮烯(DCNPNPT)分光光度法快速直接测定锌的方法。在表面活性剂TritonX-15的存在下,pH=9.5~10.5的Na2B4O7-NaOH介质中,DCNPNPT与锌( )可生成1∶3的橙黄色络合物。最大吸收波长为445nm,同时在535nm配合物有一最大负吸收,建立以535nm为参比波长,445nm为测定波长的双峰双波长法进行测定,表观摩尔吸光系数可达1.12×105L/(mol·cm)。用拟定的方法测定矿山废水中的锌,与原子吸收法测定的结果十分吻合,结果令人满意。  相似文献   

7.
合成了新试剂2-(2'-喹啉偶氮)-4,5-二甲氧基苯酚,研究了其与钴(Ⅱ)的显色反应,在pH=5.5的HAc-NaAc缓冲介质中,在十六烷基三甲基溴化铵(CTMAB)存在下,2-(2'-喹啉偶氮)-4,5-二甲氧基苯酚与钴生成2∶1稳定的配合物,该配合物λmax=575 nm,摩尔吸光系数ε为2.443×104 L·mol-1·cm-1.钴含量在0~0.4 mg/L内符合比耳定律.新方法用于水样中微量钴的测定,结果满意.  相似文献   

8.
研究了新显色剂 2 - [3- (5 -硝基苯并异噻唑 )偶氮 ]- 6 -异丙基苯酚 (5NO2 -BPAIP)与铜的显色反应 ,在pH为 7 5的氯化铵一氨水体系中 ,显色反应灵敏 ,配合物的最大吸收波长为 6 40nm ,摩尔吸光系数为 2 83× 10 5。铜含量在 0 μg/ 5 0mL~ 13 0 μg/ 5 0mL范围内符合比尔定律 ,方法简便、快速、选择性好 ,是目前光度法测铜的最灵敏的方法之一 ,用于作物中测定痕量铜 ,结果令人较为满意。  相似文献   

9.
This paper describes a methodology for estimating the take of upstream migrating adult chum salmon (Oncorhynchus keta) caused by confined underwater rock blasting. Because these fish are listed under the Endangered Species Act, it is unlawful to take (i.e., harm, capture, collect, injure, kill, etc.) them without a federal permit. In the permit for an underwater blasting project to deepen a 2 km section of the Columbia River navigation channel linking Portland, Oregon, to the Pacific Ocean, regulators defined take as the mortality of adult chum salmon due to underwater blasting. They required monitoring to estimate take to track compliance with the permit. Conventional predictive models of fish mortality from underwater blasting depend on data about the explosive charges; however, such data for this project were not available for proprietary reasons. Therefore, an innovative approach had to be conceived. The dose-exposure-response methodology we developed provided an unobtrusive, science-based methodology for monitoring and near real-time reporting of adult chum salmon take. We applied the methodology for 99 blasting events from November 1, 2009, through February 5, 2010, in the lower Columbia River (rkm 139–141). The mean absolute peak pressure in underwater sound generated by blast events was 151,685 Pa (22 psi) at a range of 42.7 m. The estimated cumulative take for the project was 0.126 adult chum salmon, far below the 10-fish mortality limit regulators set for the project. We propose that this dose-exposure-response methodology be considered wherever underwater blasting has the potential to have an adverse effect on important fish species.  相似文献   

10.
An analytical procedure has been proposed for the determination of (226)Ra at the low femtogram per ml concentration level in mineral water samples using double focusing sector field ICP-MS (ICP-SFMS). For the pre-concentration and separation of radium from the matrix elements in water a tandem of a laboratory-prepared filter, based on MnO(2), and Eichrom "Sr-specific" resin was used. The recovery of the method was determined to be 70.5%. The limit of detection for (226)Ra determination was 0.02 fg ml(-1), including a pre-concentration factor of 10. In addition, uranium concentration and uranium isotope ratios were measured by ICP-SFMS. In several mineral water samples with a relatively high uranium content, (226)Ra concentrations were found between 0.7-15 fg ml(-1). The effective dose of the contribution was calculated using the radionuclide concentration and dose conversion factors from the World Health Organization, WHO (1993). Assuming a mineral water consumption of 2 l d(-1), a slightly higher calculated dose than the suggested limit for drinking water (0.1 mSv y(-1)) was found in some samples.  相似文献   

11.
采用5-氯-2-(吡啶偶氮)-1,3-二氨基苯分光光度法测定水质钴。对分析方法的样品前处理、样品保存、样品分析条件、干扰消除、检出限及测定范围、实际样品测定进行了深入研究和技术改进。水样经消解后测定的方法检出限为0.009 mg/L,经富集后测定的方法检出限为4×10-4mg/L,干扰消除实验的回收率为96%~101%,地表水、地下水、生活污水及工业废水等4种类型水样的加标回收率为92%~103%。  相似文献   

12.
建立了用高效液相色谱法测定水中对(邻)硝基苯胺的方法。水中对(邻)硝基苯胺用乙醚萃取,在40℃水浴将乙醚挥发至干,用1.0ml甲醇提取后测定。对(邻)硝基苯胺浓度在0~1.0mg/L范围内线性良好,相关系数大于0.9994,日内相对标准偏差为6.5%和5.4%,平均回收率为104.3%和107.4%。  相似文献   

13.
本文介绍了用甲醛-硼氢化钠系统衍生水小二乙烯三肢的衍生化气相色谱测定方法。测定条件:TSD检测器,260℃;色谱柱:PT28%AT223+4%KOH涂在GasChromR80~100目。1.4m×3mm。线性范围:2.5~20mg/L。回收率:92~107%。相对标准偏差;9%。  相似文献   

14.
应用电感耦合等离子体质谱法测定饮用水中的硒元素。结果表明,高能碰撞模式(HEHe)较碰撞/反应池气体模式(He模式)消除干扰效果更好;在HEHe模式下,~(78)Se在0.5~100μg/L范围内线性良好,相关系数0.999 9,方法检出限为0.06μg/L,相对标准偏差为0.4%~0.8%,加标回收率为97.1%~103.2%。方法性能指标均能较好满足饮用水中Se的定量测试要求。  相似文献   

15.
通过探讨影响四乙基铅富集效率的捕集管类型、吹扫温度和吹扫时间等因素,建立了吹扫捕集-气相色谱法测定水质中四乙基铅的分析方法。实验结果表明,使用Tenax捕集管,在吹扫温度为50℃、吹扫15 min的条件下测定水质中的四乙基铅,捕集效率为97.6%~98.2%,在0~100μg/L范围内线性良好,检出限为0.03μg/L,加标回收率为93.2%~100.5%,相对标准偏差为1.6%~3.2%。方法操作简便快捷、准确、实用且绿色环保不消耗有机溶剂,适于水质中四乙基铅的测定。  相似文献   

16.
液相色谱法测定土壤中苯并(a)芘   总被引:1,自引:0,他引:1  
用快速溶剂萃取法ASE300对土壤样品进行前处理,以配有荧光检测器的高效液相色谱仪分析土壤样品中苯并(a)芘的含量,该方法以乙腈、水梯度比例混合作为流动相,流速为1.0 ml/min;激发波长和发射波长分别为255 nm和420 nm;保留时间为27.58 min。样品的称样量为25 g时,测定检出限为8.28×10-5mg/kg,相对标准偏差(RSD)为1.0%~12%,回收率为60%~87%,以上指标均能满足环境中土壤样品的检测要求。  相似文献   

17.
This paper reports the utilization of 4-(2-pyridylazo) resorcinol (PAR) as a chelating reagent for in-column derivatization and the determination of trace Co, Fe, and Ni ions by reversed-phase high-performance liquid chromatography with photodiode array detector. A good separation of Co, Fe, and Ni chelates were achieved by using an Inertsil ODS-3 column and a mobile phase, consisted of methanol–THF–water mixture (50:5:45) containing ammonium acetate buffer (pH 5.0) and PAR. After full optimization, good repeatability of retention times (relative standard deviation (RSD) < 0.05%) and peak areas (RSD < 1.7%) was achieved as well as a good linearity (r 2 > 0.9991). The detection limits (S/N = 3), expressed as micrograms per liter, were 0.50 (Co), 9.07 (Fe), and 2.00 (Ni). The applicability and the accuracy of the developed method were estimated by the analysis of spiked water samples and certified reference material BCR 715 wastewater-SRM.  相似文献   

18.
本文在常规Volhord回滴法测定氯化物中,加入一定量聚(I)〔1〕防凝聚剂,可以防止经典法不可避免的复分解反应,保证测定结果的准确性;同时研究了通过控制不同酸度、温度及加入不同类型试剂等简便化学手段除去十多种常见干扰物质的方法,尤其能有效除去现有各方法中最为棘手、难度较大的同族元素B-r、I-等干扰,方法简便、快速、效果显著,在工业废水的测定中优于其它方法。  相似文献   

19.
高效液相色谱法测定水和废水中邻(对)硝基氯苯   总被引:5,自引:0,他引:5  
用高效液相色谱法测定了水和废水中的邻 (对 )硝基氯苯。流动相为甲醇 /水 (70 /3 0 ) ,紫外检测波长 2 2 0 nm,方法的线性范围为 0~ 1 0 0 μg/ml,相关系数大于 0 .9998,检测限为 2 μg/L。本方法快速、准确 ,满足地面水的测定要求  相似文献   

20.
紫外分光光度法是目前水中N,N-二甲基乙酰胺(DMAC)的常用分析方法。研究结果表明,硝酸盐对紫外分光光度法测定DMAC具有很强的干扰。本研究中提出一种双波长法用于消除水中硝酸盐的干扰作用,所采用的波长对为194.0nm和219.0nm。精密度实验及加标回收实验表明,方法的相对标准偏差在4%以内,回收率为95%~102%,可有效消除硝酸盐的干扰作用。  相似文献   