首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Mycobacteria naturally aggregate in water, a characteristic that may serve to protect them against disinfection in wastewater. Secondary effluent was spiked with Mycobacterium terrae (M. terrae), sequentially filtered through 100-, 41-, and 20-microm nylon filters to partition aggregate sizes, confirmed using particle-size analysis and microscopy. Each sample was exposed to doses of UV light (10 to 60 mJ/cm2 at 254 nm) and free chlorine (27 to 150 mg-min/L at 4 degrees C). Inactivation of M. terrae in wastewater was initially rapid, with 2.5 log reduction at 14 mJ/cm2 and 56 mg-min/L for UV and free chlorine, respectively. However, in effluent and 100-microm filtered wastewater, spiked M. terrae was present to the highest doses evaluated. Interestingly, M. terrae passed through 41- and 20-microm filters were inactivated rapidly, with no survivors after moderate disinfection doses. Inactivation of Mycobacteria in wastewater may be compromised by aggregates larger than 41 microns.  相似文献   

2.
城市污水再生利用中的消毒问题研究   总被引:2,自引:0,他引:2  
从保障再生水微生物安全的角度,考察了北方某污水处理厂污水处理工艺、混凝沉淀过滤工艺以及臭氧消毒对大肠杆菌和总细菌的去除效果。结果表明,污水处理厂进水中大肠杆菌数和细菌总数分别为105~109个/L和109~1011个/L,经过厌氧-缺氧-好氧组合工艺处理后两者分别降为103~106个/L和106~109个/L,再经后续混凝沉淀过滤工艺(混凝剂PAC投加量:15 mg/L Al2O3)处理,再生水中大肠杆菌和细菌总数仍分别高达102~105个/L和105~108个/L。对上述再生水进行臭氧消毒批量实验,在臭氧反应量为12 mg/L的条件下实现了对大肠杆菌的完全灭活,此时臭氧消毒运行费用为0.13元/m3左右。  相似文献   

3.
针对城市污水再生处理工艺中卤乙酸类(HAAs)消毒副产物和卤乙酸生成潜能(HAAFP),结合三维荧光光谱,分析HAAs及其前体物的变化规律。结果表明,二级出水经2次加氯过程后,再生出水中的总卤乙酸浓度增加了90%,其中溴代乙酸的增幅最大,占增加量的82%。卤乙酸生成潜能较大的为氯代乙酸类物质,说明水中存在大量的氯代乙酸前体物。从工艺过程来看,总卤乙酸生成潜能与总有机物荧光强度分别下降了32%和28%,表明该再生处理工艺对HAAs前体物有一定的去除作用。  相似文献   

4.
Background, aim, and scope  The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Materials and methods  Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Results  Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. Discussion  When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. Conclusions  UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. Recommendations and perspectives  This study found UV LEDs to be an optimal method for bacterial disinfection. The emitted wavelength was found to be an essential factor when using LEDs; thus, care should be taken in selecting the proper LED for maximum disinfection.  相似文献   

5.
Synthesis of polyhydroxyalkanoates in municipal wastewater treatment.   总被引:1,自引:0,他引:1  
Biologically derived polyesters known as polyhydroxyalkanoates (PHAs) represent a potentially "sustainable" replacement to fossil-fuel-based thermoplastics. However, current commercial practices that produce PHA with pure microbial cultures grown on renewable, but refined, feedstocks (i.e., glucose) under sterile conditions do not represent a sustainable commodity. Here, we report on PHA production with a mixed microbial consortium indigenous to an activated sludge process on carbon present in municipal wastewaters. Reactors operated under anaerobic/aerobic and aerobic-only mode and fed primary solids fermenter liquor maintained a mixed microbial consortium capable of synthesizing PHA at 10 to 25% (w/w), while reducing soluble COD by approximately 62 to 71%. More critically, an aerobic batch reactor seeded from the anaerobic/aerobic reactor and fed fermenter liquor achieved approximately 53% PHA (w/w). Results presented suggest that environmentally benign production of biodegradable polymers is feasible. We further used PHA-rich biomass to produce a natural fiber-reinforced thermoplastic composite that can be used to offset advanced wastewater treatment costs.  相似文献   

6.
Two most probable number (MPN) methods-lauryl tryptose broth with Escherichia coli broth confirmation and direct A-1 broth incubation (A-1)--were compared for the enumeration of fecal coliform in lime-treated biosolid. Fecal coliform numbers were significantly higher using the A-1 method. Analysis of positive A-1 tubes, however, indicated that a high percentage of these were false positives. Therefore, the use of A-1 broth for 40 CFR Part 503 Pathogen Reduction (CFR, 1993) compliance testing is not recommended.  相似文献   

7.
8.
9.
The paper summarizes the results of a bench-scale study to evaluate the feasibility of using peracetic acid (PAA) as a substitute for sodium hypochlorite both for discharge into surface water and for agricultural reuse. Trials were carried out with increasing doses (1, 2, 3, 5, 10, and 15 mg/L) and contact times (6, 12, 18, 36, 42, and 54 minutes) to study disinfectant decay and bacterial removal and regrowth, using fecal coliform and Escherichia coli (E. coli) as process efficiency indicators. Peracetic acid decay kinetics was evaluated in tap water and wastewater; in both cases, PAA decays according to first-order kinetics with respect to time, and a correlation was found between PAA oxidative initial consumption and wastewater characteristics. The PAA disinfection efficiency was correlated with operating parameters (active concentration and contact time), testing different kinetic models. Two data groups displaying a different behavior on the basis of initial active concentration ranges (1 to 2 mg/L and 5 to 15 mg/L, respectively) can be outlined. Both groups had a "tailing-off" inactivation curve with respect to time, but the second one showed a greater inactivation rate. Moreover, the effect of contact time was greater at the lower doses. Hom's model, used separately for the two data groups, was found to best fit experimental data, and the disinfectant active concentration appears to be the main factor affecting log-survival ratios. Moreover, the S-model better explains the initial resistance of E. coli, especially at low active concentrations (< 2 mg/L) and short contact times (< 12 minutes). Microbial counts, performed by both traditional methods and flow cytometry, immediately and 5 hours after sample collection (both with or without residual PAA inactivation), showed that no appreciable regrowth took place after 5 hours, neither for coliform group bacteria, nor for total heterotrophic bacteria.  相似文献   

10.
11.
Environmental Science and Pollution Research - This work presents a bibliographic review of the literature regarding the simultaneous removal of contaminants of emerging concern (CECs) and...  相似文献   

12.
Wastewater disinfection is practiced with the goal of reducing risks of human exposure to pathogenic microorganisms. In most circumstances, the efficacy of a wastewater disinfection process is regulated and monitored based on measurements of the responses of indicator bacteria. However, inactivation of indicator bacteria does not guarantee an acceptable degree of inactivation among other waterborne microorganisms (e.g., microbial pathogens). Undisinfected effluent samples from several municipal wastewater treatment facilities were collected for analysis. Facilities were selected to provide a broad spectrum of effluent quality, particularly as related to nitrogenous compounds. Samples were subjected to bench-scale chlorination and dechlorination and UV irradiation under conditions that allowed compliance with relevant discharge regulations and such that disinfectant exposures could be accurately quantified. Disinfected samples were subjected to a battery of assays to assess the immediate and long-term effects of wastewater disinfection on waterborne bacteria and viruses. In general, (viable) bacterial populations showed an immediate decline as a result of disinfectant exposure; however, incubation of disinfected samples under conditions that were designed to mimic the conditions in a receiving stream resulted in substantial recovery of the total bacterial community. The bacterial groups that are commonly used as indicators do not provide an accurate representation of the response of the bacterial community to disinfectant exposure and subsequent recovery in the environment. UV irradiation and chlorination/dechlorination both accomplished measurable inactivation of indigenous phage; however, the extent of inactivation was fairly modest under the conditions of disinfection used in this study. UV irradiation was consistently more effective as a virucide than chlorination/dechlorination under the conditions of application, based on measurements of virus (phage) diversity and concentration. Taken together, and when considered in conjunction with previously published research, the results of these experiments illustrate several important limitations of common disinfection processes as applied in the treatment of municipal wastewaters. In general, it is not clear that conventional disinfection processes, as commonly implemented, are effective for control of the risks of disease transmission, particularly those associated with viral pathogens. Microbial quality in receiving streams may not be substantially improved by the application of these disinfection processes; under some circumstances, an argument can be made that disinfection may actually yield a decrease in effluent and receiving water quality. Decisions regarding the need for effluent disinfection must account for site-specific characteristics, but it is not clear that disinfection of municipal wastewater effluents is necessary or beneficial for all facilities. When direct human contact or ingestion of municipal wastewater effluents is likely, disinfection may be necessary. Under these circumstances, UV irradiation appears to be superior to chlorination in terms of microbial quality and chemistry and toxicology. This advantage is particularly evident in effluents that contain appreciable quantities of ammonia-nitrogen or organic nitrogen.  相似文献   

13.
A comparative assessment of the risks of three effluent disposal alternatives currently available to wastewater utilities in Southeast Florida is presented in this paper. The alternatives are: deep well injection and ocean outfalls following secondary treatment, and surface water (canal) discharges following secondary wastewater treatment, filtration and nutrient removal. Water quality data, relative to disposal of wastewater treatment plant effluent were gathered, along with water quality data on the receiving waters, from utilities. Comparisons and conclusions regarding potential health concerns associated with the three disposal alternatives are presented. The results indicated that health risks associated with deep wells were generally lower than those of the other two alternatives. The proximity of injection wells to aquifer storage and recovery wells was a determining factor relative to injection well risk. Urban ecological risks were also indicated to be lower, though impacts of urban water use/reuse to the Everglades were not studied. Additional data collection and analysis were recommended to understand the effects of wastewater management on the cycling of water, nutrients and other constituents on southeast Florida. In particular, it was recommended that monitoring of effluents for nitrosamines and pharmaceutically active substances be implemented on a broad scale.  相似文献   

14.
A more detailed characterization of particulate organic matter in wastewater streams is needed to improve solid-liquid separation and biological processes for wastewater treatment. The objective of this paper was to evaluate particle size distributions and the associated chemical composition for municipal, industrial, and agricultural waste streams. Most of the organic matter in these wastewaters was larger than a molecular weight of 10(3) amu and therefore would require extracellular hydrolysis before any bacterial metabolism. Particle size distributions were significantly different for the studied waste streams. In municipal wastewater, the organic matter was evenly distributed in all eight size fractions ranging from 10(3) amu up to 63 microm. The industrial and agricultural wastewaters, however, contained mainly soluble organic matter (<10(3) amu) and larger particles (>1.2 microm for the industrial and >10 microm for the agricultural waste) leaving a gap in the size range of large macromolecules and colloids. The relative protein and carbohydrate concentrations varied for the different size fractions compared to the measured chemical oxygen demand (COD) in the corresponding size fraction. Thus, the design of the solid-liquid separation at a treatment plant could be used to purposefully modify the overall chemical composition of the organic matter before further biological treatment. Particle size distributions will influence design and operation of biological nutrient removal processes such as denitrification or biological phosphorus removal that may be carbon limited if a large fraction of the organic matter is composed of large particles with slow hydrolysis rates. Measured particle size distributions for the different waste streams in this study (municipal, industrial, agricultural) were significantly different requiring specific approaches for treatment plant design.  相似文献   

15.
16.
工艺条件对磷回收过程中鸟粪石沉淀颗粒粒径的影响   总被引:1,自引:1,他引:0  
在鸟粪石沉淀法回收废水中磷的过程中,鸟粪石颗粒的大小将直接影响其沉淀的速率,进而影响鸟粪石的沉淀效果和磷的回收率。本文采用激光粒度分析仪测定鸟粪石的平均粒径,详细考察在小型连续搅拌反应-沉淀磷回收装置中不同的工艺条件下鸟粪石颗粒粒径的变化规律,并结合Stokes公式计算鸟粪石颗粒在废水出口处的沉降速率,为沉淀池的设计提供参考依据。结果表明:鸟粪石的平均粒径在12~25μm之间,沉降速率在5.46×10-5~2.37×10-4m/s之间。随着反应室水力停留时间的延长,鸟粪石颗粒的粒径逐渐增大,当停留时间超过18 min时,颗粒的粒径基本不变;随着沉淀室水力停留时间的延长,鸟粪石颗粒的平均粒径缓慢增大,当停留时间超过70 min后颗粒粒径的变化不大;鸟粪石颗粒的平均粒径在一定程度上受废水中磷初始浓度变化的影响,在磷初始浓度为62~128 mg/L时颗粒的粒径变化不大,当磷浓度为496 mg/L时粒径有较大增加,此时鸟粪石颗粒的沉降速率也大幅度增加;鸟粪石颗粒的平均粒径受pH值的影响不大;随氮磷摩尔比的增大,鸟粪石颗粒的平均粒径略有增加;随镁磷摩尔比的增大,鸟粪石颗粒的平均粒径逐渐减小,沉降速率则有明显的下降。  相似文献   

17.
Simultaneous nitrification-denitrification (SND) of municipal wastewater was investigated in a laboratory-scale membrane bioreactor (MBR) operated at two different hydraulic retention times (HRTs), 0.5 and 1 day, dissolved oxygen 3.0 to 0.5 mg/L, and solids retention time (SRT) between 28 and 120 days. The organic loading rate (OLR) (0.11 to 0.64 kg chemical oxygen demand [COD]/m3/d) and influent soluble COD (SCOD)/ total Kjeldahl nitrogen (TKN) ratio (5 to 19) were varied by the addition of glucose. The ammonia-nitrogen and TKN removals were over 97%, and total nitrogen removal was approximately 89% in the MBR. The maximum specific nitrification rates (98 mg N/d/g VSS) and specific denitrification rates (81 mg N/d/g VSS) occurred at an SCOD/TKN ratio of 9.1. The optimum conditions for maximum total nitrogen removal by SND in a single reactor MBR have been found to be low dissolved oxygen (< 0.6 mg/L) and high OLR (approximately 0.64 kg COD/m3/d) at an HRT of 0.5 day and SRT of approximately 85 days.  相似文献   

18.
利用水面照射式紫外线消毒装置对废水消毒的动力学进行了研究,确定了其动力学参数.试验结果表明,当废水的温度为18.5~23℃,浊度为11.7°~20.1°,水层厚度为8 cm,照射2 min时,废水中细菌杀灭率均在99%以上;并且当废水的浊度<20°,进水菌体浓度<1.0×105 CFU/mL时,废水紫外线消毒过程可以近似地看成为一级光生化反应,其速率常数κ为0.034~0.058 s-1.该结果可以作为废水紫外线消毒反应器设计和运行管理的参考依据.  相似文献   

19.
废水紫外线消毒的动力学研究   总被引:2,自引:0,他引:2  
  相似文献   

20.
Escherichia coli (E. coli), enterococci, and fecal coliform data were collected and compared as potential indicators for swimmablility assessment of a brackish waterbody (Lake Pontchartrain, Louisiana). These indicators were measured during lake background conditions, in stormwater runoff (before dilution with lake water), and in the outfall plume within the lake following storm events. Microbial indicator titers associated with suspended particles and lake-bottom sediments were also investigated. Overall reduction rate constants for fecal coliform, E. coli, and enterococci in lake water and sediment were measured and reported. Attachment of microbial indicators to suspended matter and subsequent sedimentation appeared to be a significant fate mechanism. A slower reduction rate of indicator organisms in sediment further suggested that bottom sediment may act as a reservoir for prolonging indicator organism survival and added concern of recontamination of overlaying waters due to potential solids resuspension. Results indicated that enterococci might be a more stable indicator than E. coli and fecal coliform and, consequently, a more conservative indicator under brackish water conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号