首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
Dust collection efficiency data were analyzed to determine better operating conditions for a two-dimensional circulating granular bed filter (CGBF). The dust collection efficiency in the granular bed was affected by the following operating parameters: the louver angle, the solids mass flow rate, and the particle size of the bed material. Experimental results showed that higher dust collection efficiency occurs when the solids mass flow rates were 20.34 +/- 0.24, 21.50 +/- 0.11, and 30.51 +/- 0.57 g/sec at louver angles of 45 degrees, 30 degrees, and 20 degrees, respectively. Optimal dust collection efficiency peaked with a louver angle of 30 degrees. Average particle sizes of bed material by sieve diameters (microm) of 795 microm had higher dust collection efficiency than the average collector particle size of 1500 microm. Dust collection efficiency is influenced by bed material attrition phenomenon, causing dust collection efficiency to decrease rapidly. The dust collection efficiency analysis not only found the system free of design defects but also assisted in the operation of the two-dimensional CGBF system.  相似文献   

2.
Wu SP  Tao S  Liu WX 《Chemosphere》2006,62(3):357-367
The size distributions of 16 polycyclic aromatic hydrocarbons (PAHs) and particle mass less than 10 microm in aerodynamic diameter (Dp) were measured using a nine-stage low-volume cascade impactor at rural and urban sites in Tianjin, China in the winter of 2003-2004. The particles exhibited the trimodal distribution with the major peaks occurring at 0.43-2.1 and 9.0-10.0 microm for both urban and rural sites. The concentrations of the total PAH (sum of 16 PAH compound) at rural site were generally less than those of urban site. Mean fraction of 76.5% and 63.9% of the total PAH were associated with particles of 0.43-2.1 microm at rural and urban sites, respectively. Precipitation, temperature, wind speed and direction were the important meteorological factors influencing the concentration of PAHs in rural and urban sites. The distributions of PAHs concentration with respect to particle size were similar for rural and urban samples. The PAHs concentrations at the height of 40 m were higher than both of 20 and 60 m at urban site, but the mass median diameter (MMD) of total PAH increased with the increasing height. The mid-high molecular weight (278 >or= MW >or= 202) PAHs were mainly associated with fine particles (Dp or=MW >or=178) PAHs were distributed in both of fine and coarse particle. The fraction of PAHs associated with coarse particles (Dp>2.1 microm) decreased with increasing molecular weight. The relatively consistent distribution of PAHs seemed to indicate the similar combustion source of PAHs at both of rural and urban sites. The fine differences of concentration and distribution of PAHs at different levels at urban site suggested that the different source and transportation path of particulate PAHs.  相似文献   

3.
A more detailed characterization of particulate organic matter in wastewater streams is needed to improve solid-liquid separation and biological processes for wastewater treatment. The objective of this paper was to evaluate particle size distributions and the associated chemical composition for municipal, industrial, and agricultural waste streams. Most of the organic matter in these wastewaters was larger than a molecular weight of 10(3) amu and therefore would require extracellular hydrolysis before any bacterial metabolism. Particle size distributions were significantly different for the studied waste streams. In municipal wastewater, the organic matter was evenly distributed in all eight size fractions ranging from 10(3) amu up to 63 microm. The industrial and agricultural wastewaters, however, contained mainly soluble organic matter (<10(3) amu) and larger particles (>1.2 microm for the industrial and >10 microm for the agricultural waste) leaving a gap in the size range of large macromolecules and colloids. The relative protein and carbohydrate concentrations varied for the different size fractions compared to the measured chemical oxygen demand (COD) in the corresponding size fraction. Thus, the design of the solid-liquid separation at a treatment plant could be used to purposefully modify the overall chemical composition of the organic matter before further biological treatment. Particle size distributions will influence design and operation of biological nutrient removal processes such as denitrification or biological phosphorus removal that may be carbon limited if a large fraction of the organic matter is composed of large particles with slow hydrolysis rates. Measured particle size distributions for the different waste streams in this study (municipal, industrial, agricultural) were significantly different requiring specific approaches for treatment plant design.  相似文献   

4.
水质对紫外消毒在两种典型再生水中应用的影响   总被引:1,自引:0,他引:1  
以大肠杆菌为对象,研究了再生水水质变化对紫外消毒效果和光复活的影响。结果表明,紫外对大肠杆菌有很强的灭活作用,在紫外剂量为4mJ/cm^2时,大肠杆菌的灭活率达到了4.41个对数级。腐殖酸、铁和2种再生水水体中其他溶解性物质会影响光吸收和紫外透射率,但对紫外消毒动力学无影响。在颗粒物浓度为0~200mg/L的范围内,外源高岭土和活性污泥等颗粒物的投加对紫外消毒效果影响较小,而再生水水样W1中原有的2.61/1:g/L的颗粒物则会极大地影响消毒效果,使UV对细菌的灭活出现明显的拖尾现象。腐殖酸会增强紫外损伤大肠杆菌的光复活能力,但2种再生水中细菌的光复活能力相对磷酸盐缓冲溶液(PBS)中减弱,减弱程度在不同水样中有所不同。  相似文献   

5.
研究水质对254 nm紫外线透射率的影响,通过动态实验考察了照射时间、254 nm紫外线透射率以及紫外线剂量对炼化企业中水消毒效果的影响并同时考察异养菌、硫酸盐还原菌和铁细菌的光复活及暗修复现象。结果表明,有机物是影响炼化企业中水紫外线消毒的重要因素;紫外线对炼化企业中水中的异养菌具有良好的灭活作用;增加照射时间对消毒效果的提升作用受254 nm紫外线透射率的影响;紫外线透射率在较低的范围内时对消毒效果的影响相对较大,在较高的范围内时影响较小;紫外线剂量-响应曲线受254 nm紫外线透射率的影响;剂量的“成分”,即照射时间和透射率的不同组合,也会对消毒效果产生影响;在80 mJ/cm2的剂量下,20 h内异养菌出现了较强烈的光复活和暗修复现象,铁细菌仅出现了明显的光复活现象,硫酸盐还原菌没有表现出明显的复活。  相似文献   

6.
The removal efficiency of granular filters packed with lava rock and sand was studied for collection of airborne particles 0.05-2.5 microm in diameter. The effects of filter depth, packing wetness, grain size, and flow rate on collection efficiency were investigated. Two packing grain sizes (0.3 and 0.15 cm) were tested for flow rates of 1.2, 2.4, and 3.6 L/min, corresponding to empty bed residence times (equal to the bulk volume of the packing divided by the airflow rate) in the granular media of 60, 30, and 20 sec, respectively. The results showed that at 1.2 L/min, dry packing with grains 0.15 cm in diameter removed more than 80% (by number) of the particles. Particle collection efficiency decreased with increasing flow rate. Diffusion was identified as the predominant collection mechanism for ultrafine particles, while the larger particles in the accumulation mode of 0.7-2.5 microm were removed primarily by gravitational settling. For all packing depths and airflow rates, particle removal efficiency was generally higher on dry packing than on wet packing for particles smaller than 0.25 microm. The results suggest that development of biological filters for fine particles is possible.  相似文献   

7.
Natural pumice particles were used as granular support media and coated with iron oxides to investigate their adsorptive natural organic matter (NOM) removal from waters. The impacts of natural pumice source, particle size fraction, pumice dose, pumice surface chemistry and specific surface area, and NOM source on the ultimate extent and rate of NOM removal were studied. All adsorption isotherm experiments were conducted employing the variable-dose completely mixed batch reactor bottle-point method. Iron oxide coating overwhelmed the surface electrical properties of the underlying pumice particles. Surface areas as high as 20.6m(2)g(-1) were achieved after iron coating of pumice samples, which are above than those of iron coated sand samples reported in the literature. For all particle size fractions, iron coating of natural pumices significantly increased their NOM uptakes both on an adsorbent mass- and surface area-basis. The smallest size fractions (<63 microm) of coated pumices generally exhibited the highest NOM uptakes. A strong linear correlation between the iron contents of coated pumices and their Freundlich affinity parameters (K(F)) indicated that the enhanced NOM uptake is due to iron oxides bound on pumice surfaces. Iron oxide coated pumice surfaces preferentially removed high UV-absorbing fractions of NOM, with UV absorbance reductions up to 90%. Control experiments indicated that iron oxide species bound on pumice surfaces are stable, and potential iron release to the solution is not a concern at pH values of typical natural waters. Based on high NOM adsorption capacities, iron oxide coated pumice may be a promising novel adsorbent in removing NOM from waters. Furthermore, due to preferential removal of high UV-absorbing NOM fractions, iron oxide coated pumice may also be effective in controlling the formation of disinfection by-products in drinking water treatment.  相似文献   

8.
Road dust contributes a large percentage of the atmosphere's suspended particles in Taiwan. Three road dust samples were collected from downtown, electrical park, and freeway tunnel areas. A mechanical sieve separated the road dust in the initial stage. Particles > 100 microm were 75%, 70%, and 60% (wt/wt), respectively, of the samples. Those particles < 37 microm were resuspended in another mixing chamber and then collected by a Moudi particle sampler. The largest mass fraction of resuspended road dust was in the range of 1-10 microm. Ultrafine particles (< 1 microm) composed 33.7, 17, and 7.4% of the particle samples (downtown, electrical park, and freeway tunnel, respectively). The road dust compositions were analyzed by inductively coupled plasma (ICP)-atomic emissions spectroscopy and ICP-mass spectrometry. The highest concentration fraction contained more aluminum (Al), iron (Fe), calcium (Ca), and potassium than other elements in the road dust particle samples. Additionally, the sulfur (S) content in the road dust from the electrical park and freeway tunnel areas was 2.1 and 3.4 times the downtown area sample, respectively. The sulfur originated from the vehicle and boiler oil combustion and industrial manufacturing processes. Furthermore, zinc (Zn) concentration in the tunnel dust was 2.6 times that of the downtown and electrical park samples, which can be attributed to vehicle tire wear and tear. Resuspended road dusts (< 10 microm) from the downtown and freeway tunnel areas were principally 2.5-10 microm Al, barium (Ba), Ca, copper (Cu), Fe, magnesium (Mg), sodium (Na), antimony (Sb), and Zn, whereas arsenic (As), chromium (Cr), and nickel (Ni) were predominant in the ultrafine particle samples (< 1 microm). Al, Ba, and Ca are the typical soil elements in coarse particles; and As, and Cr and Ni are the typical fingerprint of oil combustion and vehicle engine abrasion in ultrafine particles. There was a special characteristic of resuspension road dust at electrical park, that is, many elements, including As, Ba, Ca, cadmium, Cr, Cu, Fe, manganese (Mn), Ni, lead (Pb), S, vanadium (V), and Zn, were major in ultrafine particles. These elements should be attributed to the special manufacturing processes of electric products.  相似文献   

9.
Xu YC  Shen QR  Ran W 《Chemosphere》2003,50(6):739-745
Most of the N in surface soils occurs in organic forms, and when mineralized it plays a key role in soil fertility and plant nutrition. Our objective was to study the effect of long-term applications of organic manure on the content and distribution of forms of organic N in bulk soil and soil particle size fractions to characterize the inherent soil nitrogen fertility. Five treatments were as follows: (1) CK (no fertilizer and no manure added), (2) mineral fertilizer only, (3) straw + NPK, (4) green manure + NPK and (5) pig manure + NPK. Soil particle size fractions (0-2, 2-10, 10-50 and 50-100 microm) were isolated without chemical pretreatment by ultrasonic dispersion in water followed by sedimentation. The content of total N and forms of organic N in the bulk soil increased after long-term fertilization, and the effect varied with fertilizer type. The plot treated with only mineral fertilizer gave the highest NH3-N and the lowest amino sugar-N content in all treatments. The highest content of amino sugar-N and amino acid-N was found in the treatment of pig manure + NPK. The content (g kg(-1) fraction) of hydrolysable N within size fractions was in the order 0-2 > 2-10 > 50-100 > 10-50 microm, but the contribution of different size fraction to hydrolysable N decreased in the sequence 10-50 > 0-2 > 2-10 > 50-100 microm. Most of the applied mineral fertilizer N that remained in soils was distributed in the particle size fraction < 2 microm while most of the remaining N from manure applied with NPK was transferred into amino sugar-N in each size fraction, and amino acid-N in the size fractions > 2 microm during the process of humification.  相似文献   

10.
Hydrodynamic forces generated by an orifice plate under low pressure were examined as a means of disrupting flocs, in order to improve disinfection of treated wastewater effluents. Changes in cavitation conditions were found to have little impact on the extent of particle breakage in this experimental setup. The rate of strain (flow rate divided by the hole radius cubed), however, was found to be the best predictor of floc breakage. Floc breakage was not affected by changes in floc concentration, but was very sensitive to differences between flocs collected from different sources. Larger flocs (90 to 106 microm) were broken apart to a greater extent than smaller ones (53 to 63 microm). Hydrodynamic treatment decreased the viability of bacteria associated with large flocs, and also increased the ultraviolet dose response by up to one log unit (i.e., a factor of ten). Subjecting final effluent wastewaters to hydrodynamic treatment, therefore, provides a treatment strategy for conditions in which the presence of flocs limits the level of disinfection that can be achieved.  相似文献   

11.
The distribution of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was examined according to particle size in marine sediments, with a particular focus on fine particulates. Samples from different coastal sites were fractionated into five size groups (<2, 2-5, 5-10, 10-20, and 20-63 microm diameter) by gravitational split-flow thin fractionation. Despite the different size profiles and PCDD/F contents of the sediments at each site, PCDD/F levels in fractionations tended to increase as the particle size decreased; the PCDD/F levels in the finest particles were up to 16 times higher than in the coarsest particles, which was associated with their organic carbon contents. Log normalization showed high levels of PCDD/Fs in the fine silt particles (2-10 microm), which are consumable by aquatic biota. Because of the different toxicity and bioavailability of PCDD/Fs in different sediment particle sizes, it is important to study particle actions to understand their effects on the aquatic ecosystem.  相似文献   

12.
Continuous monitors were employed for 18 months in an occupied townhouse to measure ultrafine, fine, and coarse particles; air change rates; wind speed and direction; temperature; and relative humidity (RH). A main objective was to document short-term and long-term variation in indoor air concentrations of size-resolved particles (0.01-20 microm) caused by (1) diumal and seasonal variation of outdoor air concentrations and meteorological variables, (2) indoor sources such as cooking and using candles, and (3) activities affecting air change rates such as opening windows and using fans. A second objective was to test and compare available instruments for their suitability in providing real-time estimates of particle levels and ancillary variables. Despite different measuring principles, the instruments employed in this study agreed reasonably well for particles less than 10 microm in diameter. The three instruments measuring fine and coarse particles (aerodynamic diameter between 0.3 and 20 microm) agreed to within 30% in their overall estimates of total volume. Two of these instruments employed optical scattering, and the third used an aerodynamic acceleration principle. However, several lines of evidence indicated that the instrument employing aerodynamic acceleration overestimated concentrations for particle diameters greater than 10 microm. A fourth instrument measuring ultrafine and accumulation-mode particles (0.01-1 microm) was operated with two different inlets providing somewhat different particle size ranges. The two inlets agreed in the ultrafine region (< 0.1 microm) but diverged increasingly for larger particles (up to 0.445 microm). Indoor sources affecting ultrafine particle concentrations were observed 22% of the time, and sources affecting fine and coarse particle concentrations were observed 12 and 15% of the time, respectively. When an indoor source was operating, particle concentrations for different sizes ranged from 2 to 20 times the average concentrations when no indoor source was apparent. Indoor sources, such as cooking with natural gas, and simple physical activities, such as walking, accounted for a majority (50-90%) of the ultrafine and coarse particle concentrations, whereas outdoor sources were more important for accumulation-mode particles between 0.1 and 1 microm in diameter. Averaged for the entire year and including no periods when indoor sources were apparent, the number distribution was bimodal, with a peak at approximately 10 nm (possibly smaller), a shallow minimum at approximately 14 nm, and a second broad peak at approximately 68 nm. The volume distribution was also bimodal, with a broad peak at approximately 200 nm, a minimum at approximately 1.2 microm, and then an upward slope again through the remaining size fractions. A database was created on a 5-min averaging time basis. It contains more than 90,000 measurements by two of the instruments and approximately 30,000 by the two optical scattering instruments. About 4500 hour-long average air change rates were also calculated throughout the year using a dedicated gas chromatograph with electron capture detection (GC/ECD). At high air change rates [> 0.8 air changes per hour (hr(-1))], particle concentrations were either elevated (when no source was present) or depressed (when an indoor source was operating) by factors of up to 2 compared with low air change rates.  相似文献   

13.
In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 microm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 microm. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

14.
Particle formation from showering may be attributed to dissolved mineral aerosols remaining after evaporation of micron-sized satellite droplets produced by the showerhead or from splashing of larger shower water droplets on surfaces. Duplicate continuous particle monitors measured particle size distributions in a ventilated residential bathroom under various showering conditions, using a full-size mannequin in the shower to simulate splashing effects during showering. Particle mass concentrations were estimated from measured shower particle number densities and used to develop emission factors for inhalable particles. Emission source strengths of 2.7-41.3 microg/ m3/min were estimated under the various test conditions using residential tap water in Columbus, OH. Calculated fine particulate matter (PM2.5) concentrations in the bathroom reached several hundred micrograms per cubic meter; calculated coarse particulate matter (PM10) levels approached 1000 microg/m3. Rates of particle formation tended to be highest for coarse shower spray settings with direct impact on the mannequin. No consistent effects of water temperature, water pressure, or spray setting on overall emission rates were apparent, although water temperature and spray setting did have an effect when varied within a single shower sampling run. Salt solutions were injected into the source water during some tests to assess the effects of total dissolved solids on particle emission rates. Injection of salts was shown to increase the PM2.5 particle formation rate by approximately one third, on average, for a doubling in tap water-dissolved solids content; PM10 source strengths approximately doubled under these conditions, because very few particles >10 microm were formed.  相似文献   

15.
The treatment process described in this research explores the impact of exposing water samples containing fecal coliforms to the radiation produced by single ultraviolet (UV) light-emitting diodes (LEDs) operating at 265 nm. UV LEDs are long lasting, compact in size and produce more efficient light output than traditional mercury-vapour bulbs, making them ideal for application in point-of-use disinfection systems, such as in remote areas. In this study, contaminated water samples containing either a pure culture of Escherichia coli or tertiary effluent from the City of Regina Wastewater Treatment Plant were used to study the application and efficiency of using UV LEDs for water disinfection. The results indicate that bacterial inactivation was achieved in a time-dependent manner, with 1- and 2.5-log E. coli reductions in water following 20 and 50 min of UV LED exposure, respectively. Ultraviolet radiation was less effective in reducing coliform bacteria in wastewater samples due to the elevated turbidity levels. Further work remains to be completed to optimize the application of UV LEDs for point-of-use disinfection systems; however, the results from this study support that bacterial inactivation using UV LEDs is possible, meriting further future technological development of the LEDs.  相似文献   

16.
This study monitored particle size-dependent variations in atmospheric polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Two gas/particle partitioning models, the subcooled liquid vapor pressure (P(L)(0)) and the octanol-air partition coefficient (K(OA)) model, were applied to each particle sizes. The regression coefficients of each fraction against the gas/particle partition coefficient (K(P)) were similar for separated particles within the same sample set but differed for particles collected during different periods. Gas/particle partitioning calculated from the integral of fractions was similar to that of size-segregated particles and previously measured bulk values. Despite the different behaviors and production mechanisms of atmospheric particles of different sizes, PCDD/F partitioning of each size range was controlled by meteorological conditions such as atmospheric temperature, O(3) and UV, which reflects no source related with certain particle size ranges but mixed urban sources within this city. Our observations emphasize that when assessing environmental and health effects, the movement of PCDD/Fs in air should be considered in conjunction with particle size in addition to the bulk aerosol.  相似文献   

17.
Ran Y  Fu JM  Sheng GY  Beckett R  Hart BT 《Chemosphere》2000,41(1-2):33-43
The association of pollutants (nutrients, heavy metals and organic compounds) with colloidal and suspended particle matter (SPM) plays a dominant role in determining their transport, fate, biogeochemistry, bioavailability and toxicity in natural waters. A scheme for the fractionation and composition of colloidal and SPM from river waters has been tested. All four separation methods, i.e. sieving, continuous flow centrifugation, tangential flow filtration, sedimentation field-flow fractionation, were for the first time used to separate five size particulate fractions from river. Significant (gram) amounts of colloidal material (<1 microm) in three size ranges, nominally 1-0.2, 0.2-0.006 and 0.006-0.003 microm were obtained. The separation scheme was able to process large samples (100 l), within reasonable times (1 day) and the apparatus was portable. The aquatic colloid size was also characterized with high resolution by using sedimentation field-flow fractionation technique. The mass-based particle size distribution for the water sample showed a broad size distribution between 0.05 and 0.4 microm with the maximum around 0.14 microm. There was a systematic increase in the content of organic carbon (estimated by loss on ignition), Mg, Ca, Na, Cu and Zn with decreasing particle size, highlighting the importance of the colloidal (<1 microm) fraction. It was concluded that the colloidal Cu and Zn concentrations in rivers might be much higher than those reported before.  相似文献   

18.
Fang GC  Wu YS  Chang SY  Lin JB  Lin JG 《Chemosphere》2007,67(5):966-974
For reasonable and convenient assessments of the characteristics of the dry deposition velocities between Taichung harbor site and Wuchi town site in central Taiwan, the overall dry deposition velocities of several metallic elements were calculated as the particulate diameter (D(p)) distributions of large particles (D(p) > 10 microm), coarse particles (10 microm < D(p) < 2.5 microm), and fine particles (D(p) < 2.5 microm) based on the ambient measurements during March-December of 2004. In this work, the dry deposition fluxes showed the higher correlation with coarse particle concentrations than large particle concentrations; however, the least well correlation was observed between the dry deposition fluxes and the fine particle concentrations. The calculated best-fit overall dry deposition velocities obtained using coarse particle concentrations varied from approximately 0.2 cm s(-1) for Cr to 1.5 cm s(-1) for Pb and 0.2 cm s(-1) for Fe to 2.6 cm s(-1) for Pb at Taichung harbor and Wuchi town site, respectively. In general, the crustal elements had higher deposition velocities than anthropogenic elements. In addition, overall dry deposition velocities for crustal elements were higher in Wuchi town site than in Taichung harbor site. The results identified the dry deposition flux was mainly contributed from large and coarse particles due to their high deposition velocities. The results also indicated that the best approach to estimate overall dry deposition was by depending on the characteristics of particles with diameters larger than 2.5 microm.  相似文献   

19.
Particle size distribution (PSD) analysis was used to evaluate the quality of mixed liquors collected from different activated sludge process modifications (i.e., conventional activated sludge, modified Ludzack-Ettinger, high-purity oxygen, step-anoxic, and oxidation ditch). An experiment protocol was developed to define the allowable sample holding time and provide representative and repeatable results. Samples of 26 treatment plants, with a total of 37 samples, were tested. A new indicator, called mean particle size (MPS), was introduced to describe the integrated mean particle size. The results of MPSs of three cut-off sizes (0.5 to 50, 100, and 200 microm) showed that the average size of mixed-liquor biosolids increased with increasing solids retention time (SRT), and the number of particles in the sedimentation supernatant decreased with increasing SRT. Particle deflocculation occurred after excessive sample holding time, and analysis within 12 hours generally eliminated sample holding problems. The results provide a methodology using PSD for characterizing mixed-liquor biosolids.  相似文献   

20.
Exposures from indoor environments are a major issue for evaluating total long-term personal exposures to the fine fraction (<2.5 microm in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that biocontamination is one of the important indoor air pollutants. Major indoor air biocontaminants include mold, bacteria, dust mites, and other antigens. Once the biocontaminants or their metabolites become airborne, IAQ could be significantly deteriorated. The airborne biocontaminants or their metabolites can induce irritational, allergic, infectious, and chemical responses in exposed individuals. Biocontaminants, such as some mold spores or pollen grains, because of their size and mass, settle rapidly within the indoor environment. Over time they may become nonviable and fragmented by the process of desiccation. Desiccated nonviable fragments of organisms are common and can be toxic or allergenic, depending upon the specific organism or organism component. Once these smaller and lighter fragments of biological PM become suspended in air, they have a greater tendency to stay suspended. Although some bioaerosols have been identified, few have been quantitatively studied for their prevalence within the total indoor PM with time, or for their affinity to penetrate indoors. This paper describes a preliminary research effort to develop a methodology for the measurement of nonviable biologically based PM, analyzing for mold and ragweed antigens and endotoxins. The research objectives include the development of a set of analytical methods and the comparison of impactor media and sample size, and the quantification of the relationship between outdoor and indoor levels of bioaerosols. Indoor and outdoor air samples were passed through an Andersen nonviable cascade impactor in which particles from 0.2 to 9.0 microm were collected and analyzed. The presence of mold, ragweed, and endotoxin was found in all eight size ranges. The presence of respirable particles of mold and pollen found in the fine particle size range from 0.2 to 5.25 microm is evidence of fragmentation of larger source particles that are known allergens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号