1.
Zhang HJ  Ni YW  Chen JP  Zhang Q 《Chemosphere》2008,70(4):721-730
Optimizing the operating parameters to minimize polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDD/F) emission is the common interest of the municipal solid waste (MSW) incineration industry. In this study, we investigated the distribution of tetra- to octa-CDD/F along the flue gas line in a full-scale reciprocating grate incinerator and evaluated the effects of temperature control and O(2) level on PCDD/F formation. Six runs were laid out and all performed under sufficient burning conditions, in which the combustion efficiency of MSW was more than 99.9%. The total concentration of tetra- to octa-CDD/F measured at the boiler outlet showed an increasing tendency with the increase of boiler outlet temperature (T(B)) from 214 degrees C to 264 degrees C. When flue gas ran across the semi-dry scrubber and cyclone precipitator, in which the temperature varied from 264 degrees C to 162 degrees C, the concentrations of the lower chlorinated dioxins and furans were significantly raised, especially for the TCDF. Increasing O(2) supply from 6.0% to 10.5% essentially led to a higher yield of tetra- to octa-PCDD/F, suggested that under sufficient burning conditions the lower O(2) level was favorable for reducing PCDD/F formation and emission. The variation of O(2) level did not give rise to a systematical change of PCDD/F homologue pattern. For all measurements, the isomer distributions of tetra- to hepta-PCDD/F were more or less the same, nearly independent of variations in the operating conditions and sampling positions. Only the significant increase of the sum of 1,3,7,8-TCDF and 1,3,7,9-TCDF was found in the zone after the boiler section.  相似文献   

2.
Wang HC  Hwang JF  Chi KH  Chang MB 《Chemosphere》2007,67(9):S177-S184
The PCDD/F concentrations and removal efficiencies achieved with air pollution control devices (APCDs) during different operating periods (start-up, normal operation, and shut-down) at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS), and selective catalytic reduction system (SCR) as APCDs. The sampling results indicate that the PCDD/F concentrations at the EP inlet during start-up period were 15 times higher than that measured during normal operation period. The PCDD/F concentration observed at shut-down period was close to that measured at normal operation period. The CO concentration was between 400 and 1000 ppm during start-up period, which was about 50 times higher compared with the normal operation. Hence, combustion condition significantly affected the PCDD/F formation concentration during the waste incineration process. In addition, the distributions of the PCDD/F congeners were similar at different operating periods. During the normal operation and shut-down periods, the EP decreases the PCDD/F concentration (based on TEQ) by 18.4-48.6%, while the removal efficiency of PCDD/Fs achieved with SCR system reaches 99.3-99.6%. Nevertheless, the PCDD/F removal efficiency achieved with SCR was only 42% during the 19-h start-up period due to the low SCR operating temperature (195 degrees C).  相似文献   

3.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

4.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

5.
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3–4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP. Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter.

Implications: This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2–3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.  相似文献   

6.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

7.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

8.
Bulk depositions and surface soil were collected in a suburban area, near the Adriatic Sea, in order to assess the contribution of a municipal solid waste incinerator to the area’s total contamination with polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs and PCDFs). Samples were collected at two sites, situated in the area most affected by plant emissions (according to the results of the Calpuff air dispersion model), and at an external site, considered as a reference. Results show that the studied area is subject to low contamination, as far as these compounds are concerned. Deposition fluxes range from 14.3 pg m−2 d−1 to 89.9 pg m−2 d−1 (0.75 pg-TEQ m−2 d−1 to 3.73 pg-TEQ m−2 d−1) and no significant flow differences are observed among the three monitored sites. Total soil concentration amounts to 93.8 ng kg−1 d.w. and 1.35 ng-TEQ kg−1 d.w, on average, and confirms a strong homogeneity in the studied area. Furthermore, from 2006 to 2009, no PCDD/Fs enrichment in the soil was noticed. Comparing the relative congener distributions in environmental samples with those found in stack emissions from the incineration plant, significant differences are observed in the PCDD:PCDF ratio and in the contribution of the most chlorinated congeners. From this study we can conclude that the incineration plant is not the main source of PCDD/Fs in the studied area, which is apparently characterized by a homogeneous and widespread contamination situation, typical of an urban area.  相似文献   

9.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

10.
The aim of this study was to measure, 6 years after regular operations, the concentrations of a number of organic substances in blood and urine of 19 workers employed at a hazardous waste incinerator (HWI) in Spain, and to establish the temporal variation with respect to baseline data and previously performed surveys. This facility was the first, and so far the only HWI in that country. The levels of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB 28, 52, 101, 138, 153 and 180) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were analyzed in six composite plasma samples, while concentrations of di-, tri, and pentachlorophenols, as well those of 1-hydroxypyrene were measured in the urine of these workers. The current mean PCDD/F concentration, 10.4 ng I-TEQ/kg lipid, was significantly lower than that found in the baseline survey, 26.7 ng I-TEQ/kg lipid and similar to that found in the previous (2004) study (7.7 ng I-TEQ/kg lipid). PCDD/F levels in plasma were similar or even lower than those recently reported for various non-exposed populations. For the remaining analyzed substances in plasma and urine, there was not any significant increase in comparison with the levels found in the baseline survey. On the other hand, no marked differences between the concentrations of organic substances in plasma or urine were found according to the respective workplace (plant, laboratory and administration). The results of the present survey indicate that after 6 years of regular operation, the workers at the HWI are not occupationally exposed to PCDD/Fs and other organic substances in their workplaces.  相似文献   

11.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

12.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二(口恶)英同类物的含量及其毒性当量.结果表明,产生的二(口恶)英主要存在于飞灰中,烟气中的含量很少.飞灰中二(口恶)英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二(口恶)英的浓度之和与毒性当量之和分别为0.34 ng/m3和0.02 ng/m3,而布袋除尘器前的烟尘和烟气中二(口恶)英的浓度之和与毒性当量之和分别为40.78 ng/m3和3.01ng/m3.飞灰和烟尘中2,3,7,8位氯取代二(口恶)英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二(口恶)英同类物的分布差别较大.通过了解有毒二(口恶)英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二(口恶)英的排放量,减少垃圾焚烧对环境的污染.  相似文献   

13.
Lee CC  Chen HL  Su HJ  Guo YL  Liao PC 《Chemosphere》2005,59(10):1465-1474
The aim of this study was to evaluate the PCDD/Fs patterns in ambient air based on data information emitted from incinerator generated from ambient air measurements and those in serum. Four circular zones, namely A, B, C, and D, were identified based on simulated ambient annual average PCDD/Fs concentrations, from a selected municipal waste incinerator. Sixteen ambient samples were taken from the 4 circular zones across 4-seasons. Eighty-nine volunteers were recruited according to the demographic distribution within each zone. PCDD/Fs profiles were documented both for air and serum samples collected. Comparing to the congener patterns from ambient air and serum samples, we found that OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD, and 1,2,3,4,6,7,8-HpCDF were the predominant groups among 17 congeners from both the ambient air and serum sample. And, factor analysis showed the distribution patterns of PCDD/Fs from ambient air and serum samples are almost identical across different zones, except for congener patterns of serum samples from residents in zone C. In addition, the average PCDD/Fs level significantly reduced for about 10 folds than those of the other three seasons when the incinerator was shut down in one of sampling periods. We might conclude that ambient air exposure was the most important contributor to PCDD/Fs levels in ambient air but not the single in serum. Therefore, another or more powerful source, such as occupational exposure, dietary intake or the consumption of local food, should be further investigated at the same time.  相似文献   

14.
PCDD/DF in leachates from Korean MSW landfills   总被引:1,自引:0,他引:1  
Choi KI  Lee DH 《Chemosphere》2006,63(8):1353-1360
We analyzed levels of PCDD/DF in leachate liquid and solid from five Korean municipal solid waste landfills to investigate the relationship between PCDD/DF and dissolved organic carbon and suspended solids in raw leachate. The concentrations of PCDD/DF ranged from 173.2 to 1329.4 pg/l and 4.1 to 46.22 pg-TEQ/l. The range of PCDD/DF was 123.2-1161.3 pg/l in leachate solid and 50.0-383.3 pg/l in leachate liquid. Our results indicated that PCDD/DF in solid play a major role in determining their concentration levels, and the distribution of isomers in solid was almost the same as in liquid leachate. In addition, highly chlorinated PCDD/DF, such as HpCDD/DF and OCDD/DF, accounted for more than 70% of all isomers. Levels of PCDD/DF in liquid were strongly correlated with dissolved organic carbon concentrations, which increase the leachability (R2 = 0.92 in Korean leachate) of PCDD/DF from contaminant sources. Despite this high linearity between dissolved organic carbon and dissolved PCDD/DF, we observed no strong relationship between dissolved organic carbon and solid phase PCDD/DF (R2 = 0.001). Dissolved organic carbon scarcely affects dissolved PCDD/DF to be combined with solids. As a result, it is not appropriate for incinerated ash to be dumped with municipal solid wastes, as they have a large potential to result in high levels of organic matter, and therefore PCDD/DF, in leachate.  相似文献   

15.
Inhibition of PCDD/Fs formation from dioxin precursors by calcium oxide   总被引:1,自引:0,他引:1  
Liu W  Zheng M  Zhang B  Qian Y  Ma X  Liu W 《Chemosphere》2005,60(6):785-790
Research aimed at understanding the inhibition effect of CaO on polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) formation form dioxins precursors, such as chlorophenols (CPs) and chlorobenzenes (CBs). The results indicated that a clear dioxin inhibition effect occurred both in open and sealed system when CaO was used. In the open system, PCDDs were the main congeners and the inhibition efficiency was all over 99% in the experiments. In the experiments with CaO, less than 0.1% of the initial PCP was detected in the absorption tube and only about 1% of the initial PCP was examined as calcium pentachlorophenate in the reaction tube. In the sealed system, the inhibition efficiency was over 90% at temperature range between 280 and 450 degrees C when PCP was used as model precursor. When HCB and 2,3,4,5-T4CP replaced PCP, significant inhibition effect was also observed. As CaO has the advantageous properties of non-toxicity and non-volatile nature, it is our hope that the result will contribute to the development of a new technique to cope with the problem of dioxin pollution in MWIs.  相似文献   

16.
A nationwide investigation into polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) in market seafood was conducted for the first time in this study. Total PCDD/F concentrations in fatty fish ranged from 0.13 to 8.64 pg g−1 wet weight (mean 2.05 pg g−1 wet weight), total PCB concentrations ranged from 38.9 to 3514 pg g−1 wet weight (mean 1133 pg g−1 wet weight), and total PBDE concentrations ranged from 42.8 to 913 pg g−1 wet weight (mean 322 pg g−1 wet weight). Corresponding mean toxicity equivalent (TEQ) values for total PCDD/F and dioxin-like PCB were 0.25 pg g−1 wet weight (WHO 98-TEQ) and 0.32 pg g−1 wet weight (WHO 98-TEQ), respectively. OCDD, PCB-138 and PBDE-47 were the dominant compounds according to their respective congeners. WHO 98-TEQ PCDD/PCDF/PCB for fatty fish and shell fish were 0.60 and 0.070 pg g−1 wet weight, respectively, lower than the standard set by the European Commission. The contamination levels and profiles were compared with those documented in previous publications.  相似文献   

17.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

18.
The emission abatement of polychlorinated dioxins and furans (PCDD/F) Issued from municipal solid waste incineration is growing in importance because of more stringent emission standards and general concern about their toxic characteristics. These substances cannot be separated by conventional gas cleanup processes but are successfully removed through adsorption onto carbonaceous materials. The simplest technique is the entrained-phase injection of pulverized adsorbents in the flue gas, followed by fabric filter separation. The various related techniques are briefly reviewed here. Operating conditions and results obtained from Flemish MSWIs are given. The results illustrate the excellent overall removal efficiency. Furans are adsorbed to a slightly higher extent than dioxins. PCDD/F removal by carbonaceous adsorbents is thereafter modeled from first principles for the contribution of both entrained-phase (eta1) and cake filtration (eta2) to the overall efficiency (etaT). Application of the model equations and comparison of measured and predicted overall efficiencies for the Flemish municipal solid waste incinerators (MSWIs) demonstrate that the approach is meaningful and that the dominant parameters are the operating temperature, the dosage and activity of adsorbent, and the fraction of adsorbent in the filter cake. The model equations enable the MSWI operators to predict the adsorption efficiencies for any combination of operating parameters and to assess the sensitivity of the process to varying operating conditions.  相似文献   

19.
In the present work, an experimentation was carried out to study the behaviour of PCDD/F during the process of municipal solid waste (MSW) bio-drying. This process belongs to the biological mechanical treatment (BMT) options and is aimed to the dewatering of MSW thanks to the biological exothermal reactions (thermal drying, on the contrary, needs an external heat source as methane). The result is a decrease of waste weight and an increase of lower heating value (as the energy content refers to a lower amount of waste). Of course, the overall energy availability does not increase, but the characteristics of bio-drying are interesting as a way for refuse derived fuel generation: glass, metals and inert removals are easier after bio-drying. The literature of the sector shows only few data on PCDD/F emission to air from BMT. Anyway, in the present work an original theory has been put forward in order to explain the enrichment of PCDD/F in the air exiting the biological processes. The role of the initial PCDD/F concentration in the ambient air entering the plant is obviously taken into account. The results of the developed experimentation and the following elaborations point out that PCDD/F could be freed from the volatile solids consumed during the process. The different amount of PCDD/F in the waste and the different consumption of volatile solids depending on the biological process can explain the different PCDD/F emission factors available in the literature.  相似文献   

20.
Gas/particle partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient air was investigated in a satellite town in Eastern China from April 2007 to January 2008 comprehending large temperature variations (from 3 to 34 °C, daily average). Molecular weight, molecular structure and ambient temperatures are the three major factors that govern the gas/particle partitioning of atmospheric PCDD/Fs throughout the year. Generally, good agreements were obtained (except for winter) between measured particulate fractions and theoretical estimates of both the Junge–Pankow adsorption model and Harner Bidleman absorption model using different sets of subcooled liquid vapor pressure and octanol–air partition coefficient (Koa), respectively. Models utilizing estimates, derived from gas chromatographic retention indices (GC-RIs), are more accurate than that of entropy-based. Moreover, during winter, the Koa-based model using the GC-RIs approach performs better on lower chlorinated PCDD/Fs than that of -based. Furthermore, possible sources of mismatch between measured and predicted values in winter (3–7 °C) were discussed. Gas adsorption artifact was demonstrated to be of minor importance for the phenomena observed. On the other hand, large deviations of slopes (mr) and intercepts (br) in logKp vs. plots from theoretical values are observed in the literature data and these are found to be linearly correlated with ambient temperatures (P<0.001) in this study. This indicates that the non-equilibrium partitioning of PCDD/Fs in winter may be significantly influenced by the colder temperatures that may have slowed down the exchange between gaseous and particulate fractions.  相似文献   