 共查询到20条相似文献,搜索用时 359 毫秒
1.
The purpose of this study was to compare the effects of 2 kinds of underwear made from hydrophobic and hydrophilic fabrics on the mean skin temperatures and clothing microclimate (temperature, humidity) in participants performing intermittent exercise in cold environmental conditions.

One or 2 layers of cotton underwear (C1, C2) with a 2-piece long-sleeved shirt and long-legged trousers, and 1 or 2 layers of polypropylene underwear (P1, P2) with a 2-piece long-sleeved shirt and long-legged trousers were used as experimental underwear. In addition, the participants wore a 2-piece ski suit as 100% polyester clothing including 100% polyester padding. Ten young adult females volunteered as participants. The experiments were performed in a climatic chamber at an ambient temperature (Ta) of 0°C and an air velocity of 0.26 m s?1.

The major findings are summarized as follows: (a) Although the clothing microclimate humidity was not different within the ski suit of outer clothing between C1 and P1, it was significantly higher in P2 than in C2; (b) Clothing microclimate temperature inside the ski suit did not differ between C1 and P1, whereas it was significantly higher in P2 than in C2; (c) The thermal gradient between innermost and outermost of clothing microclimate at back level did not show any difference between C1 and P1, but it was significantly higher in C2 than in P2. These results are discussed in terms of thermal physiology and clothing sciences.  相似文献   

2.
本文目的是评价降温背心的降温效果。通过对3名成年人在不同环境条件下,分别穿着降温背心和普通服装,测量人员胸部、上肢、下肢和直肠温度的变化,同时监测心率、呼吸和出汗量等,得出环境温度越高,降温背心的降温效果越明显;体形胖的人耐热能力相对差;耐热与出汗量密切相关等结论,并指出降温背心的降温效果显著,能够满足高温岗位的需要。  相似文献   

3.
IntroductionSeveral studies have concluded that pedestrians typically overestimate their own conspicuity to approaching drivers at night. The present experiments extended this research by exploring the accuracy of drivers' judgments of pedestrian conspicuity while facing varying degrees of headlight glare.MethodIn Experiment 1, participants on an open road estimated their ability to see a roadside pedestrian in each of two clothing configurations and with each of three different glare intensities present. In Experiment 2, participants responded to a roadside pedestrian under the same open road conditions; the participants were naïve with regard to both the position of the pedestrian and to the clothing and glare manipulations.ResultsConsistent with earlier research, estimates of response distance were, on the average, over three times greater than actual recognition distance. The extent to which participants overestimated conspicuity was greater when the pedestrian wore a retroreflective vest, and participants incorrectly judged that headlight glare would not degrade drivers' ability to see a pedestrian wearing a retroreflective vest.Conclusions and Practical ApplicationsThese results confirm that road users' understanding of issues involving drivers' night vision is limited. These misunderstandings may result in road users behaving in ways that increase the risk of nighttime collisions with pedestrians.  相似文献   

4.
Five students of a rescue training school cycled at 50 W for 20 min at 20 °C before walking at 5 km/hr up to 30 min in a climatic chamber at 55 °C and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28–30 min in light clothing, but quit after 20–27 min in 3 firefighter ensembles due to a rectal temperature of 39 °C or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.  相似文献   

5.
Objective. The provision of appropriate personal cooling vests is recognized as an effective measure to combat heat stress. However, personal cooling vests are not widely implemented in the Hong Kong industries. The current study aims to evaluate the usability of a hybrid cooling vest that is associated with the success of its application in industrial settings. Methods. A self-administrated questionnaire focusing on 10 subjective attributes of cooling effect, ergonomic design and usability of a hybrid cooling vest was administered with 232 occupational workers in the construction, horticultural and cleaning, airport apron services and kitchen and catering industries. Results. A structural equation model estimated by analysis of moment structures was constructed to evaluate the usability of the cooling vest, as influenced by cooling effect and ergonomic design. Results showed that cooling effect (path coefficient?=?0.69, p?p?Conclusions. The structural equation model is feasible to examine the complex nature of the structural relationships among the subjective perceptions of personal cooling vests. The empirical findings furnish sound evidence for further optimization of the hybrid cooling vest in terms of cooling effect and ergonomic design for occupational workers.  相似文献   

6.
The purpose of this study was to determine the usefulness of physiological studies in the evaluation of protective clothing for work in a cold environment. The study included the examination of the dynamics of changes in chosen physiological parameters (core and skin temperatures, heart rate, pulmonary minute ventilation) as well as physical ones (the temperature and relative humidity under the clothes) during work in protective clothing with unknown thermal insulation. The experiment was conducted in extreme environmental conditions (–10 and –15°C) at a work load defined by the clothing manufacturer as moderate. Results show that thermal equilibrium was achieved and maintained throughout the investigated work time (60 min) and that the protective clothing ensures safety on the time scale of a regular 8-hour work day. It was also shown that the dynamics of thermal stress physiological parameters can be used to determine the maximum duration of exposure for cold protective clothing with unknown thermal insulation.  相似文献   

7.
The temperature at which coal dust glows is normally much lower than the auto-ignition temperature (AIT) of methane/air mixtures, and thus a better understanding is needed regarding methane/air ignition in a heated environment in the presence of coal particles. A horizontal tube apparatus was used to test the effect of brown coal and two kinds of bituminous and anthracite on methane/air combustibility. For the four coal samples tested, the presence of coal particles significantly reduced the minimum temperature for ignition of methane/air mixtures in a heated environment. No. 1 bituminous coal with 12 mm diameter decreased the ignition temperature value from 595 to 500 °C. It is thought that pre-ignition of low-AIT volatiles emitted from the heated coal particles ignited the methane/air mixtures. Volatiles, sulfur content, and large porosity of piled coal particles all enhanced ignition of methane/air mixtures in a hot environment, while water content and small particle size reduced ignition. For anthracite, no ignition occurred when temperatures of the heated environment were lower than the AIT of methane (595 °C), except for the 12-mm-diameter sample. Anthracite did not readily ignite methane/air mixtures and the ignition mechanism was somewhat similar to that of a burning cigarette.  相似文献   

8.
Although the effects of jet fires are often limited to rather short distances, if their flames impinge on a pipe or a vessel collapse can occur in very short times. In such cases, the heat flux on the affected equipment is very high and wall temperature can increase very rapidly. This can happen in parallel pipelines, if a release occurs and impinges on another one. Nevertheless, jet fire impingement has been scarcely studied. In this communication the results obtained from an experimental set-up are presented. Sonic jet fires impinged on a pipe containing stagnant air or water. The temperatures of the flames impinging on it were measured for the worst case (flame front-bright zone), as well as the evolution with time of the pipe wall temperature at different locations. Initial temperature increases up to around twenty °C/s were registered for the air inside, with maximum values of up to 600 °C reached in 2.5 min, and 800 °C in approximately 9 min. In the case of pipe containing water, in the zone of the wall in contact with the liquid the heating rates were much lower, the maximum temperature reached being up to approximately 150 °C. From the temperatures of the jet flames and of the pipe, the heat fluxes reaching the pipe and the corresponding heat transfer coefficients were obtained. The results obtained emphasized that safe distances are essential in pipelines, together with fire proofing and other safety measures.  相似文献   

9.
Personal cooling garments (PCGs) have gained increased attention in recent years due to heat stress and strain in the working environment. The present study was conducted in hot environments of an iron foundry to evaluate the efficacy of a battery-operated PCG. Twenty-four workers were exposed to climatic conditions of 35.89?±?1.25?°C, 35% relative humidity during 90-min work with PCG and habitual clothing (HC). Mean weighted skin temperature was significantly lower by 4.84?±?1.05?°C compared with HC 0.38?±?1.02?°C (p?p?相似文献   

10.
Mine rescuers’ heat load under the same physical effort load (25% of the maximal oxygen uptake), using three types of breathing apparatus, in newly developed heat-removing underwear and outerwear was assessed for typical work conditions of mine rescuers, under milder and harsher ambient conditions of 32 and 38?°C, respectively, both at relative humidity of 85% and air velocity of 1.0?m/s. Expending physical effort at the same load while using different kinds of breathing apparatus resulted in a similar heat load. Under both milder and harsher ambient conditions, heat storage and sweating intensity were greater than the average limit value recommended by hygienic standards, which indicates that the use of breathing apparatus significantly hinders heat exchange with the environment. The developed clothing for mine rescuers was highly rated, and was considered by most people to be better than that used currently.  相似文献   

11.
Lysine is widely used in the fields of food, medicine and feed, which generally appears in the form of lysine sulfate or lysine hydrochloride dust because of the high instability of the free L-lysine. The L-lysine Sulfate is in high risk of decomposition, spontaneous ignition and even the dust explosion, because the control temperature in its production process is high up to 90 °C. Thus, the thermal behaviors and its thermal stability of 65% lysine sulfate are experimentally explored in Air and Nitrogen using the simultaneous TG-DSC measurements. Results show: (1) the decomposition of 65% lysine sulfate can be divided into three stages both in the atmospheres of air and nitrogen, and most of the weight loss occurred in the first two stages, which are related with the decarboxylation and deamination process. (2) The effects of atmosphere on the decomposition of 65% lysine sulfate mainly occur at the third stage. In this stage, the weight loss in nitrogen is only 14.2%, which is much lower than that in air (34.3%), which is related to the oxidative degradation at high temperature. Besides, the active energy is slightly increased in nitrogen compared to that in air. (3) The initial temperatures of the decomposition of the 65% lysine sulfate are 145 °C and 155 °C, for the air and nitrogen atmosphere, respectively, which are much lower than that (260 °C) of the pure lysine.  相似文献   

12.
The explosion characteristics of propane–diluent–air mixtures under various temperatures and pressures were investigated using a 20-L apparatus. The explosion limits of propane diluted with nitrogen or carbon dioxide were measured at high temperatures from 25 to 120 °C. The results showed that the upper explosion limit (UEL) increased, and the lower explosion limit (LEL) decreased with the rising temperature. The explosion limits of propane diluted with nitrogen or carbon dioxide were also measured at high pressures from 0.10 to 0.16 MPa. The results showed that the UEL increased, and the LEL almost remainedunchanged along with increased pressure. Under the same initial operating conditions, the concentration of nitrogen required to reach the minimum inerting concentration (MIC) point was higher than the concentration of carbon dioxide. Finally, the study investigated the limiting oxygen concentration (LOC) of propane under various initial temperatures, initial pressures, and inert gases. The LOC of propane decreased approximately linearly with increased temperature or pressure, and the LOC of propane dilution with carbon dioxide was greater than dilution with nitrogen from 25 to 120 °C or from 0.10 to 0.16 MPa, which indicated that the dilution effect of carbon dioxide was better than that of nitrogen.  相似文献   

13.
The flammability of refrigerants is a major cause of refrigerant explosion incidents. Studying the explosion characteristics of refrigerants at different initial temperatures can provide significant benefits for solving the safety problems of refrigerants under actual working conditions. This paper studied the effects of the initial temperature and refrigerant concentration on the explosion characteristics of refrigerant 2, 3, 3, 3-tetrafluoropropene (R1234yf) at 0.1 MPa. The curves of explosion characteristics with different initial temperature revealed the same variation trend ranged from 25 °C to 115 °C. Specifically, as the refrigerant concentration was raised, the peak overpressure, the maximum rate of pressure rise, and laminar burning velocity increased initially and decreased afterwards, along with maximum values at the refrigerant concentration of 7.6%. When the refrigerant concentration was 7.6%, the peak overpressure declined exponentially with the initial temperature rise, while the maximum rate of pressure rise increased linearly. The laminar burning velocity calculated from the spherical expansion method indicated that the flame propagation was gradually accelerated by the increase of initial temperature, which coincided with the change of the maximum rate of pressure rise. Meanwhile, experiments and CHEMKIN simulation results demonstrated the effects of elevated temperature from 20 °C to 50 °C on the explosion limits of R1234yf. The lower explosion limit reduced and the upper explosion limit increased with rising initial temperature. In general, R1234yf exhibited moderate combustion and lower explosion risk, compared with traditional refrigerants.  相似文献   

14.
Passive alcohol sensors (PAS) are screening devices designed to sample nonintrusively the ambient air around a driver's mouth to determine the presence of alcohol. Studies have shown that PAS devices can aid police officers in the identification of unpaired drivers, particularly at sobriety checkpoints. Data from a 1996 nationwide survey, in which 5,392 drivers were evaluated for alcohol using both the PAS III (a passive sensor housed in a flashlight) and evidential breath test devices, have allowed the determination of appropriate criteria at various blood alcohol concentrations (BAC) for detecting impaired drivers in the field. Using the appropriate criteria, the PAS III can identify about 75% of the drivers with BACs at or above 0.10%, and 70% at or above 0.08%. This is a vast improvement over the 40-50% detection rate currently achieved by police officers at checkpoints not using sensors. Using the PAS III few drivers would be identified inappropriately. At the criterion recommended for detecting BACs at or above 0.08%, about 14% of drivers with BACs of 0.02-0.05% would be incorrectly identified as having a higher BAC. Field studies have shown that when police officers rely on observation alone about 20% of drivers with low BACs are detained for further evaluation. More widespread use of passive sensors by police officers would aid in the detection of drinking drivers. Sensors also could provide an additional deterrent to the general public if they believe that when stopped by the police after drinking they will be detained for further evaluation.  相似文献   

15.
A visual-visual dual computer task was designed to test the effect of the thermal environment on dual task performance. The temperatures selected for testing were 20 and 35 °C Wet Bulb Globe Temperature (WBGT). 34 volunteers were randomly assigned to 1 of the 2 temperature conditions. Individual differences in single task performance were controlled by equating the baselines of single task performance. Once individual differences in single task capacity were controlled, statistically significant differences in performance were demonstrated. Mean accuracy was computed over a 1-hr testing period in each temperature condition. Participants’ mean accuracy in the 35° condition (38.18%) was substantially lower than in the 20° condition (50.88%).  相似文献   

16.
Traumatic events are a particular type of stressor that may affect police officers engaged in front line duties. In this study, specific types of social support predicted to buffer the psychological and physical health effects of trauma are drawn from theory and empirical evidence in the area of post‐traumatic stress. Social support, measured as the content of communication, and the ease of talking about trauma was tested with 527 working police officers who responded to a questionnaire survey. Hierarchical regression analysis showed that the communication variables contributed to the variance in post‐traumatic stress disorder and physical symptoms with differential effects for different aspects of communication. Analysis of the effects of traumatic stress on symptoms for sub‐groups at different levels of communication showed that some types of communication, such as the ease of talking about trauma or positive communications about work, moderate the effects of stress for police officers, in that higher levels are associated with a weaker trauma–strain relationship. However, some types of communication buffered stress only at moderate levels and other types may not be protective. These results are discussed in terms of the types and sources of social support that are likely to buffer post‐traumatic stress at work. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
The processes of acclimation to hot-dry and to warm-humid climates were studied using two approaches: a quantitative analysis of literature data and an experimental study in the laboratory concerning the physiological parameters of heart rate, rectal temperature, sweat loss, and subjective assessment.

Analysis o f literature data: Data from 62 experiments with a total of 813 participants were pooled and recalculated. The experiments ranged from 6 to 24 days, air temperatures from 30.4 to 50.0°C, water vapor pressures from 1.5 to 6.5 kPa, and wet bulb globe temperatures (WBGT) from 27.4 to 38.6°C.

Laboratory studies: In the laboratory, 8 participants were acclimated during 15 consecutive days to a hot-dry climate and to a warm-humid climate, which were equivalent in terms of the WBGT (33.5 and 33.6°C, respectively). The participants walked four times for 25 min on a treadmill at a speed of 4 km/h. The hot-dry climate caused somewhat greater strain than the warm-humid condition. In the course of acclimation to the hot-dry climate, heart rate and rectal temperature started at higher levels, decreased slightly steeper but remained on a higher level throughout. Nevertheless, the differences between both thermal conditions were small, and both physiologic functions reached the point of acclimation almost at the same time under warm-humid and under hot-dry exposure. Sweat loss, which is not regarded as a valid predictor for acclimation, was considerably higher but increased less in the hot-dry than in the warm-humid climate.  相似文献   

18.
A number of small-scale methods have been used to determine the safe drying temperature, on a 2 tonne scale, of an organic powder. Predictions of the temperature for which the Time to Maximum Rate (TMR) is 100 hours are used to compare the results. The predicted temperatures range from 50°C to 120°C raising the issue of taking the result from a single test method in isolation.  相似文献   

19.
A 2-m, adiabatic column has been successfully refurbished and recommissioned for coal self-heating research at The University of Queensland. Subbituminous coal from the Callide Coalfields reached thermal runaway in just under 19 days from a starting temperature of 20–22 °C. The coal was loaded as two layers, with an R70 index of 2.73 °C h−1 and 5.90 °C h−1 for the upper layer and lower layer respectively. Initially, a hotspot developed in the upper layer between 120 and 140 cm from the air inlet due to moisture adsorption. After 7 days, self-heating in the lower half of the column began to take over, consistent with the higher R70 index of this coal. The location of the final hotspot was approximately 60 cm from the air inlet. Further tests on Australian coals, with the column, will enable a better understanding of coal self-heating under conditions closely resembling mining, transport and storage of coal. The results from the column will also provide industry with the information needed to manage the coal self-heating hazard.  相似文献   

20.
The suitability of the IREQ (insulation required) index for predicting the thermal responses of 6 participants wearing chemical protective clothing was tested during exercise at -20 and -25 °C. IREQ was used to calculate duration limited exposure (DLE). Measured DLE correlated (r= .899, p < .001) with the predicted DLE. In exposures exceeding 40 min, however, the predicted DLE tended to be 10-20 min too short compared to the measured one. During short exposures the prediction was 5-20 min too long. The results show that IREQ overestimated the cold strain in participants wearing chemical protective clothing during cold exposures longer than 40 min. Nevertheless, predicted DLE never exceeded measured times and thus the prediction was always safe from the occupational point of view.  相似文献   