Poly‐ and perfluoroalkyl substances (PFASs) have been identified by many regulatory agencies as contaminants of concern within the environment. In recent years, regulatory authorities have established a number of health‐based regulatory and evaluation criteria with groundwater PFAS concentrations typically being less than 50 nanograms per liter (ng/L). Subsurface studies suggest that PFAS compounds are recalcitrant and widespread in the environment. Traditionally, impacted groundwater is extracted and treated on the surface using media such as activated carbon and exchange resins. These treatment technologies are generally expensive, inefficient, and can take decades to reach treatment objectives. The application of in situ remedial technologies is common for a wide variety of contaminants of concern such as petroleum hydrocarbons and volatile organic compounds; however, for PFASs, the technology is currently emerging. This study involved the application of colloidal activated carbon at a site in Canada where the PFASs perfluorooctanoate (PFOA) and perfluorooctane sulfonic acid (PFOS) were detected in groundwater at concentrations up to 3,260 ng/L and 1,450 ng/L, respectively. The shallow silty‐sand aquifer was anaerobic with an average linear groundwater velocity of approximately 2.6 meters per day. The colloidal activated carbon was applied using direct‐push technology and PFOA and PFOS concentrations below 30 ng/L were subsequently measured in groundwater samples over an 18‐month period. With the exception of perfluoroundecanoic acid, which was detected at 20 ng/L and perfluorooctanesulfonate which was detected at 40 ng/L after 18 months, all PFASs were below their respective method detection limits in all postinjection samples. Colloidal activated carbon was successfully distributed within the target zone of the impacted aquifer with the activated carbon being measured in cores up to 5 meters from the injection point. This case study suggests that colloidal activated carbon can be successfully applied to address low to moderate concentrations of PFASs within similar shallow anaerobic aquifers.  相似文献   

2.
Because of the remarkable chemical structure of perfluoroalkyl and polyfluoroalkyl substances (PFAS), as well as the complex conditions of water, selecting an appropriate adsorbent for treating PFAS is critical. Adsorption needs to be environmentally friendly, low cost, and consider the types of adsorbents that work well in mixed PFAS solutions. In the present study, we used mixed PFAS to estimate the PFAS activity. This research aimed to evaluate and compare the efficacy of the adsorption of PFAS from water using different adsorbents: granular activated carbon (GAC), IRA 910 (strong anion resin), and DOWEX MB-50 (mixed exchange resin). Batch adsorption isotherms and kinetic studies were performed for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS). Freundlich models consistently described the kinetic behavior with a high correlation coefficient (R2 > 0.98). PFAS adsorption capacities on GAC and IRA910 were dependent on the chain length (PFOS > PFOA > PFHxS). The adsorption capacity of DOWEX MB-50 decreased because of the sulfonate effects (PFOS > PFHxS > PFOA). The rate constants (k2) that represented the adsorption of PFAS on different adsorbents observed within 96 h were accurately determined by the pseudo-second-order (PSO) model. GAC achieved followed the relationship k2(PFOS) > k2(PFOA) > k2(PFHxS). Furthermore, k2 of IRA910 decreased in the order of k2(PFOA) > k2(PFOS) > k2(PFHxS), implying that IRA910 promoted hydrophobicity more significantly on the adsorption of PFCAs than perfluoroalkane (-alkyl) sulfonic acids. The kinetics of DOWEX MB-50 revealed k2(PFHxS) > k2(PFOS) > k2(PFOA) because gel-type resins like DOWEX MB-50 are more suitable for shorter-chain PFAS. Further investigation is needed to determine the effect of organic matter under natural conditions and evaluate adsorptive selection caused by operational complexities.  相似文献   

3.
Per and polyfluoroalkyl substances (PFAS) are emerging and persistent organic pollutants that have been detected in many environmental media, humans, and wildlife. A common method to effectively remove PFAS from water is adsorption by activated carbon. Preliminary sorption experiments were conducted using five characterized Calgon Corporation coal‐based granular activated carbon (GAC; F100, F200, F816, F300, and F400), one coconut‐based GAC (CBC‐OLC 12 × 30), and one Jacobi Corporation coal‐based GAC (Omni‐G 12 × 40). Sorption of four representative PFAS onto each GAC was measured to select the most favorable carbon sources. F400 and CBC were chosen based on their performance in preliminary PFAS sorption experiments and contrasting properties. Freundlich and Langmuir isotherm models were developed for perfluorooctanoic acid (PFOA) and perfluorooctanoic sulfonate (PFOS) at an initial concentration of 1 mg/L. Sorption capacities were determined for PFOA and PFOS individually and in the mixture. Individual compounds showed higher sorption than when present in the mixture for both PFOA and PFOS. PFOS showed higher sorption than PFOA both individually and in the mixture and F400 showed higher sorption capacity than CBC. The presence of co‐contaminants (kerosene, trichloroethylene, and ethanol), and variations in groundwater conditions (pH, presence of anions, naturally occurring organic matter, and iron oxides) demonstrated limited impact on the sorption of PFAS onto GAC under the experimental conditions tested.  相似文献   

4.
Amec Foster Wheeler and Emerging Compounds Treatment Technologies, Inc. tested pilot‐scale ex situ treatment technologies for treatment of poly‐ and perfluorinated alkyl substances (PFAS) in groundwater. The pilot test compared ion exchange resin to granular activated carbon (GAC) and evaluated in‐place regeneration of the resin to restore PFAS removal capacity. During the pilot test, both resin and GAC removed perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) below U.S. Environmental Protection Agency (USEPA) health advisories (HAs) of 0.070 micrograms per liter (μg/L) combined. Compared at a common empty bed contact time (EBCT) of five minutes, the resin treated over eight times as many bed volumes (BVs) of groundwater as GAC before PFOS exceeded the USEPA HA and six times as many BVs for PFOA. On a mass‐to‐mass basis, resin removed over four times as much total PFAS per gram as GAC before breakthrough was observed at the USEPA HA. A solution of organic solvent and brine was used to regenerate the resin in the lead vessel, which had treated water up to the point of PFOS and PFOA breakthrough exceeding the USEPA HAs. The pilot test demonstrated successful in‐place regeneration of the resin to near‐virgin conditions. The regenerated resin was then used to treat the contaminated groundwater up to the same breakthrough point. Compared to the virgin resin loading cycles, PFAS removal results for the regenerated resin were consistent with virgin resin.  相似文献   

5.
In situ chemical oxidation (ISCO) of petroleum hydrocarbons (PHCs) within groundwater is considered a proven approach to addressing PHC‐impacted groundwater in nonsaline environments. One of the most common oxidants used for oxidation of PHCs in groundwater is hydrogen peroxide (H2O2). Due to its highly reactive nature, H2O2 is often stabilized to aid in increasing its reactivity lifespan. Limited research and application of ISCO has been completed in warm, saline groundwater environments. Furthermore, even fewer studies have been completed in these environments for ISCO using stabilized H2O2. In this research, stabilized H2O2 was examined to determine its effectiveness in the treatment of PHCs and the additive methyl tert‐butyl ether (MTBE). Three stabilizers (citrate, phytate, silica [SiO2]) were tested to determine if the stabilizers could enhance and extend the treatment life of H2O2 within saline groundwater. To determine the effect of salinity on the three stabilizers, groundwater and aquifer samples were collected from two saline locations that had different salinity (total dissolved solids of about 7,000 mg/L and 18,000 mg/L). Specific target chemicals for treatment were water soluble, mobile components of gasoline including benzene, toluene, ethylbenzene, xylenes, (BTEX) and MTBE. Previous studies using unactivated persulfate indicated that the PHCs within the groundwater could be oxidized, however, only limited oxidation of the MTBE could be affected. The results of the laboratory tests indicated that greater than 95 percent of the target hydrocarbons were removed within 7 days of treatment. Microcosms with citrate‐stabilized H2O2 demonstrated a significantly faster and greater decline with most hydrocarbon concentrations reaching < 5 μg/L. The exceptions were ethylbenzene and m‐xylene, which were slightly decreased to about 30 and 20 μg/L, respectively. Initial mean concentrations of the BTEX compounds within the citrate‐stabilized microcosms were 10,554 μg/L, 9,318 μg/L, 6,859 μg/L, and 14,435 μg/L, respectively. The silicate‐stabilized H2O2 microcosms showed no significant benefit over the unstabilized control microcosms. The better performance of citrate‐stabilized microcosms was confirmed by increasing δ13C values of remaining hydrocarbons. MTBE declined from > 400 mg/L to < 100 mg/L in all microcosms, again with the best removal (> 90 percent) being measured in the citrate‐stabilized microcosms. Unfortunately, H2O2 oxidation in the microcosms also resulted in production of up to 40 mg/L TBA or approximately 10 percent of the MTBE oxidized.  相似文献   

6.
The remediation of per‐ and polyfluoroalkyl substances by injection of colloidal activated carbon (CAC) at a contaminated site in Central Canada was evaluated using various visualization and modeling methods. Radial diagrams were used to illustrate spatial and temporal trends in perfluoroalkyl acid (PFAA) concentrations, as well as various redox indicators. To assess the CAC adsorption capacity for perfluorooctane sulfonate (PFOS), laboratory Freundlich isotherms were derived for PFOS mixed with CAC in two solutions: (1) PFOS in a pH 7.5 synthetic water that was buffered by 1 millimolar NaHCO3 (Kf = 142,800 mg1‐a La/kg and = 0.59); and (2) a groundwater sample (pH = 7.4) containing PFOS among other PFAS from a former fire‐training area in the United States (Kf = 4,900 mg1‐a La/kg and a = 0.24). A mass balance approach was derived to facilitate the numerical modeling of mass redistribution after CAC injection, when mass transitions from a two‐phase system (aqueous and sorbed to organic matter) to a three‐phase system that also includes mass sorbed to CAC. An equilibrium mixing model of mass accumulation over time was developed using a finite‐difference solution and was verified by intermodel comparison for prediction of CAC longevity in the center of a source area. A three‐dimensional reactive transport model (ISR‐MT3DMS) was used to indicate that the CAC remedy implemented at the site is likely to be effective for PFOS remediation for decades. Model results are used to recommend remedial design and monitoring alternatives that account for the uncertainty in long‐term performance predictions.  相似文献   

7.
Duckweed species are promising macrophytes that can be used in wastewater treatment due to their rapid growth, ease of harvest, low fiber feed potential, and high protein contents. Waste‐water contaminants that are likely to be generated during washing of coal are total suspended solids (TSS), chemical oxygen demand (COD), acidity or alkalinity (pH), and metallic contaminants. Bioprocesses were developed to evaluate the potential of duckweed (Lemna minor) to treat coal washery effluent (CWE) as well as to study the impact on the biochemical changes of the Lemna minor. CWE samples were diluted with distilled water (DW) in different ratios as follows: T1‐CWE:DW(20:80%), T2‐CWE:DW(40:60%), T3‐CWE:DW(60:40%), T4‐CWE:DW (80:20%), T5‐CWE (100%), and Control‐DW(100%). The electrical conductivity of the effluent treated with Lemna minor was 0.035 deciSiemens per meter (dS/m) in the control at Day 10 and substantially higher at treatment ratios of 100, 80, and 60 percent (1.754, 1.842, and 1.631 dS/m). The highest amount of TSS was observed at test ratio T5 (38,834 mg/L), followed by T4 (28,816 mg/L), T3 (26,970 mg/L), T2 (15,320 mg/L), T1 (4,524 mg/L), and control (424 mg/L). Total hardness was higher (820 mg/L) in T4 compared to the control (220 mg/L). Total hardness of the effluent decreased after 30 days of incubation in all the treatment aliquots. The CWE at 20 percent concentration increased the duckweed population and no adverse impacts on its growth were observed. At higher concentration (T5) total mortality of Lemna minor was observed. The chlorophyll production was determined to be inversely proportional to the effluent concentration. Based on this study, it is concluded that Lemna minor can be used for treating CWE after dilution with fresh water.  相似文献   

8.
The degradation of chitosan by means of ultrasound irradiation and its combination with homogeneous photocatalysis (photo-Fenton) was investigated. Emphasis was given on the effect of additive on degradation rate constants. 24 kHz of ultrasound irradiation was provided by a sonicator, while an ultraviolet source of 16 W was used for UV irradiation. To increase the efficiency of degradation process, degradation system was combined with Fe(III) (2.5 × 10−4mol/L) and H2O2 (0.020–0.118 mol/L) in the presence of UV irradiation and the rate of degradation process change from 1.873 × 10−9−6.083 × 10−9 mol1.7 L s−1. Photo-Fenton process led to complete chitosan degradation in 60 min with the rate increasing with increasing catalyst loading. Sonophotocatalysis in the presence of Fe(III)/H2O2 was always faster than the respective individual processes. A synergistic effect between ultrasound and ultraviolet irradiation in the presence of Fenton reagent was calculated. The degraded chitosans were characterized by X-ray diffraction (XRD), gel permeation chromatography (GPC) and Fourier transform infrared (FT-IR) spectroscopy and average molecular weight of ultrasonicated chitosan was determined by measurements of intrinsic viscosity of samples. The results show that the total degree of deacetylation (DD) of chitosan change, partially after degradation and the decrease of molecular weight led to transformation of crystal structure. A negative order for the dependence of the reaction rate on total molar concentration of chitosan solution within the degradation process was suggested. Results of this study indicate that the presence of catalyst in the reaction medium can be utilized to reduce molecular weight of chitosan while maintaining the power of irradiated ultrasound and degree of deacetylation.  相似文献   

9.
Fresh leachate, generated in municipal solid waste incineration (MSWI) plants, contains various pollutants with extremely high strength organics, which usually requires expensive and complex treatment processes. This study investigated the feasibility of blending treatment of MSWI leachate with municipal wastewater. Fresh MSWI leachate was pretreated by coagulation–flocculation with FeCl3 2 g/L and CaO 25 g/L, plate-and-frame filter press, followed by ammonia stripping at pH above 12. After that, blending treatment was carried out in a full-scale municipal wastewater treatment plant (WWTP) for approximately 3 months. Different operational modes consisting of different pretreated leachate and methanol addition levels were tested, and their performances were evaluated. Results showed that throughout the experimental period, monitored parameters in the WWTP effluent, including COD (<60 mg/L), BOD5 (<20 mg/L), ammonium (<8 mg/L), phosphorus (<1.5 mg/L) and heavy metals, generally complied with the Chinese sewage discharged standard. Under the experimental conditions, a certain amount of methanol was needed to fulfill TN removal. An estimation of the operation cost revealed that the expenditure of blending treatment was much lower than the total costs of respective treatment of MSWI leachate and municipal wastewater. The outcomes indicated that blending treatment could not only improve the treatability of the MSWI leachate, but also reduce the treatment cost of the two different wastewaters.  相似文献   

10.
This paper analyses the evolution of the physico-chemical characteristics of the leachate from the Central Landfill of Asturias (Spain), which has been operating since 1986, as well as different treatment options. The organic pollutant load of the leachate, expressed as chemical oxygen demand (COD), reached maximum values during the first year of operation of the landfill (around 80,000 mg/L), gradually decreasing over subsequent years to less than 5000 mg/L. The concentration of ammonium, however, has not decreased, presenting values of up to 2000 mg/L. When feasible, recirculation can greatly decrease the organic matter content of the leachate to values of 1500–1600 mg COD/L. Applying anaerobic treatment to leachates with a COD between 11,000 and 16,000 mg/L, removal efficiencies of 80–88% were obtained for organic loading rates of 7 kg COD/m3 d. For leachates with lower COD (4000–6000 mg/L), the efficiency decreased to around 60% for organic loading rates of 1 kg COD/m3 d.Applying coagulation–flocculation with iron trichloride or with aluminium polychloride, it was possible to reduce the non-biodegradable organic matter by 73–62% when treating old landfill leachate (COD: 4800 mg/L, BOD5: 670 mg/L), also reducing turbidity and colour by more than 97%. It is likewise possible to reduce the non-biodegradable organic matter that remains after biological treatment by adsorption with activated carbon, although adsorption capacities are usually low (from 15 to 150 mg COD/g adsorbent). As regards ammonium nitrogen, this can be reduced to final effluent values of 5 mg/L by means of nitrification/denitrification and to values of 126 mg/L by stripping at pH 12 and 48 h of stirring.  相似文献   

11.
There are numerous non-biodegradable organic materials in the mature landfill leachate. To meet the new discharge standard of China, additional advanced treatment is needed for the effluent from the biological treatment processes of leachate. In this study, a combined process including two stages of “Fenton-biological anaerobic filter (BANF)–biological aerated filter (BAF)” was evaluated to address the advanced treatment need. The Fenton oxidation was applied to reduce chemical oxygen demand (COD) and enhance biodegradability of refractory organics, and the BANF–BAF process was then applied to remove the total nitrogen (TN). The treatment achieved effluent concentrations of COD < 70 mg/L, TN < 40 mg/L and NH3–N < 10 mg/L. The removal efficiency of COD and TN were 96.1% and 95.9%, respectively. The effluent quality met the new discharge standard for Pollution Control on the Landfill Site of Municipal Solid of PR China (GB16889-2008). The operation cost of these processes was about 36.1 CHY/t (5.70 USD/t).  相似文献   

12.
Leachate contains amounts of non-biodegradable matters with COD range of 400–1500 mg/L after the biological treatment, and should be removed further to attain the Chinese discharge standards. Hydration reaction has the potential to combine and solidify some recalcitrant substances, and thus could be applied as the advanced leachate treatment process. It was found that COD and NH3N decreased from 485 to <250 mg/L and 91 to 10 mg/L, with the removal rate over 50% and 90% in the first 6 d, respectively, and COD and NH3N removal capacity were around 23.7 and 9.2 mg/g under the test conditions. The percentage of the substances with low Mn range of <1000 decreased from 32.9% to 3.2% in leachate after hydration reaction. Tricalcium aluminate, tricalcium silicate and dicalcium silicate were the most activity compounds successively for the pollutant removal in leachate, and hydration reaction could be the option for the advanced wastewater treatment process thereafter.  相似文献   

13.
Perfluorooctanoic acid (PFOA), perfluorohexanoic acid (PFHxA) and perfluorooctane sulfonate (PFOS) adsorbed onto granular activated carbon (GAC) were thermally treated in N2 gas stream. The purpose was to assess the fate of perfluoroalkyl and polyfluoroalkyl substances (PFASs) during thermal regeneration of GAC, which had been used for water treatment. Mineralized F, residual PFASs including short-chained species, and volatile organic fluorine (VOF) were determined. In a temperature condition of 700 °C, VOF were 13.2, 4.8, and 5.9 % as for PFOA, PFHxA, and PFOS. However, the VOF decreased to 0.1 %, if the GAC and off-gas were kept at 1000 °C. No PFASs remained in GAC at 700–1000 °C; at the same time, short-chained PFASs were slightly detected in the aqueous trapping of off-gas at 800 and 900 °C conditions. The destruction of PFASs on GAC could be perfect if the temperature is higher than 700 °C; however, the process is competitive against volatile escape from GAC. Destruction in gaseous phase needs a temperature as high as 1000 °C. Destruction of PFASs on the surface of GAC, volatile escape from the site, and thermolysis in gas phase should be considered, as to thermal regeneration of GAC.  相似文献   

14.
The bio-hydrogen generation potential of sugar industry wastes was investigated. In the first part of the study, acidogenic anaerobic culture was enriched from the mixed anaerobic culture (MAC) through acidification of glucose. In the second part of the study, glucose acclimated acidogenic seed was used, along with the indigenous microorganisms, MAC, 2-bromoethanesulfonate treated MAC and heat treated MAC. Two different COD levels (4.5 and 30 g/L COD) were investigated for each culture type. Reactors with initial COD concentration of 4.5 g/L had higher H2 yields (20.3–87.7 mL H2/g COD) than the reactors with initial COD concentration of 30 g/L (0.9–16.6 mL H2/g COD). The 2-bromoethanesulfonate and heat treatment of MAC inhibited the methanogenic activity, but did not increase the H2 production yield. The maximum H2 production (87.7 mL H2/g COD) and minimum methanogenic activity were observed in the unseeded reactor with 4.5 g/L of initial COD.  相似文献   

15.
This study investigated the electrochemical oxidation of stabilized leachate from Pulau Burung semi-aerobic sanitary landfill by conducting laboratory experiments with sodium sulfate Na2SO4 (as electrolyte) and graphite carbon electrodes. The control parameters were influent COD, current density and reaction time, while the responses were BOD removal, COD removal, BOD:COD ratio, color and pH. Na2SO4 concentration was 1 g/L. Experiments were conducted based on a three-level factorial design and response surface methodology (RSM) was used to analyze the results. The optimum conditions were obtained as 1414 mg/L influent COD concentration, 79.9 mA/cm2 current density and 4 h reaction time. This resulted in 70% BOD removal, 68% COD removal, 84% color removal, 0.04 BOD/COD ratio and 9.1 pH. Electrochemical treatment using graphite carbon electrode was found to be effective in BOD, COD and color removal but was not effective in increasing the BOD/COD ratio or enhancing biodegradability of the leachate. The color intensity of the treated samples increased at low influent COD and high current density due to corrosion of electrode material.  相似文献   

16.
This study investigated the fluoride removal efficiency and adsorption of a low-cost adsorbent prepared using aluminum-modified activated carbon from khat (Catha edulis) in a batch-mode reactor. The operating factors, including pH, adsorbent dose, and fluoride initial concentration, were optimized using the Box Behnken design of response surface methodology. The correlation coefficient (R2) for the removal of fluoride was found to be 0.93, showing the validity of the developed quadratic model. The results showed that, under optimized conditions of an adsorbent dose of 2.47 g/L, an initial fluoride concentration of 2.1 mg/L, an initial pH 6.08, and 60 min, 90% fluoride reduction was achieved. Meanwhile, the adsorption isotherm and kinetics followed the Langmuir adsorption model and the Pseudo second model, respectively, with a monolayer adsorption capacity of 0.3065 mg/g. On the other hand, Fourier transform infrared spectroscopy and scanning electron microscopy analyses revealed the formation of major peaks of components such as hydroxyl and carboxylic acids. The same optimum treatment conditions (adsorbent dose of 2.47 g/L, initial pH 6.08, and treatment time of 60 min) managed to remove low initial fluoride concentrations of 3.67 and 4.33 mg/L from real groundwater by 72.84% and 70.37%, respectively. The modified adsorbent prepared in this study successfully treat the low fluoride concentration to a level recommended by WHO for drinking water.  相似文献   

17.
The objective of this study was to investigate the feasibility of using a microbial biopolymer produced by Acetobacter xylinum as a carbon source for heterotrophic biological denitrification. The denitrification rate, COD availability and nitrite concentration were response parameters. Under the experimental conditions, a denitrification rate of about 0.74 kg NO3 N/m3d at 6 h retention time was achieved with microbial cellulose (MC). The reactor effluent contained significantly COD concentrations (20–86 mg/L) so it was not carbon limited, and was receiving enough carbon to facilitate the denitrification process. The maximum nitrite concentration in the effluent was found to be 0.4 mg/L. However, decreasing the retention time to 3 h significantly reduced the efficiency. It can be concluded that the MC is a suitable carbon source for nitrate removal in a heterotrophic biological denitrification process.  相似文献   

18.
A high content of refractory organic matter, ammonia and toxic compounds is characteristic of landfill leachate. Advanced oxidative processes (AOPs) are an attractive alternative for landfill leachate treatment. However, when applied as a unique process treatment, they do not provide a complete solution for the effluent treatment. Combining AOP with a membrane separation process (MSP) presents a number of benefits and provides an adequate solution for this problem. With this in mind, the present work aims to evaluate, using a bench scale, leachate treatability through AOP by Fenton’s reagent (AOP/Fenton) combined with microfiltration (MF) and nanofiltration (NF). A high efficient removal of COD (63%), true color (76%) and humic substances (50%) was observed during AOP/Fenton under optimized conditions (1.7 g H2O2/g CODraw leachate; FeSO4·7H2O:H2O2 = 1:5.3; pH = 3.8; reaction conditions = 115 rpm/28 min). According to the evaluated parameters, MSP presented an efficient complementary treatment, in which the integrity of the stages was sufficient for reaching regulatory levels in the effluent (Deliberação Normativa Conjunta COPAM/CERH-MG No. 1, May 5, 2008).  相似文献   

19.
The textile and dyeing industries are among the largest water-consuming and polluting industries in the world. The most important feature of the textile dyeing industry wastewater is its color, due to the use of colored materials. Most of these dye compounds are resistant to conventional purification methods and their biodegradation is very low through secondary purification processes, resulting in incomplete removal. Therefore, selecting the optimal method to remove these color compounds is essential. In this study, we studied the removal of an organic dye contaminant (Reactive Blue dye 19 [RB19]) using advanced oxidation processes (AOPs). For this purpose, ultraviolet (UV) mercury lamps with a wavelength of 254 nm and a voltage of W16 inside a reactor were used as an energy source. The experiments were performed in a collimated beam reactor inside a dark chamber. Two oxidizers, sodium hypochlorite (NaOCl) and hydrogen peroxide (H2O2), were used to remove RB19 from the artificial sewage stream. Removal of RB19 with a concentration of 20 mg/L with variable pH (5, 7, and 9), oxidant concentrations (5, 10, and 20 mg/L), and time (5, 10, 15, and 30 min) were investigated during the processes of photolysis, chemical oxidation (by H2O2 and NaOCl), and UV/NaOCl and UV/H2O2 AOPs. The photolysis process did not remove the RB19. The highest removal efficiencies of RB19 by chemical oxidation processes with NaOCl and H2O2, UV/NaOCl, and UV/H2O2 at optimal conditions (pH = 5, [oxidant] = 20 mg/L, RB19 = 20 mg/L, and radiation intensity of 1005 mJ/cm2) were 64.49%, 0.88%, 99.7%, and 13.31%, respectively. These results indicate that the hydroxyl radical was produced, under optimum conditions, more in the acidic medium; thus, the RB19 removal efficiency was higher in the acidic medium. The combination of UV rays with oxidants resulted in the production of more hydroxyl radicals and increased removal efficiency.  相似文献   

20.
The filamentous alga Hydrodictyon reticulatum harvested from a bench-scale wastewater treatment pond was used to evaluate biogas production after ultrasound pretreatment. The effects of ultrasound pretreatment at a range of 10–5000 J/mL were tested with harvested H. reticulatum. Cell disruption by ultrasound was successful and showed a higher degree of disintegration at a higher applied energy. The range of 10–5000 J/mL ultrasound was able to disintegrated H. reticulatum and the soluble COD was increased from 250 mg/L to 1000 mg/L at 2500 J/mL. The disintegrated algal biomass was digested for biogas production in batch experiments. Both cumulative gas generation and volatile solids reduction data were obtained during the digestion. Cell disintegration due to ultrasound pretreatment increased the specific biogas production and degradation rates. Using the ultrasound approach, the specific methane production at a dose of 40 J/mL increased up to 384 mL/g-VS fed that was 2.3 times higher than the untreated sample. For disintegrated samples, the volatile solids reduction was greater with increased energy input, and the degradation increased slightly to 67% at a dose of 50 J/mL. The results also indicate that disintegration of the algal cells is the essential step for efficient anaerobic digestion of algal biomass.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏