首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Research by the National Institute for Occupational Safety and Health (NIOSH) has pursued quartz analysis for the specialized filter assemblies of a new worker-wearable personal dust monitor (PDM). The PDM is a real-time instrument utilizing a tapered element oscillating microbalance (TEOM). Standard fiberglass TEOM filters cannot accommodate the desired P-7 infrared analytical method used by the Mine Safety and Health Administration (MSHA). Novel filter materials were tested with the objective of demonstrating this type of analysis. Low temperature ashing and spectrometric examination were employed, revealing that nylon fiber candidate filters left minimal residual ash and produced no significant spectral interference. Avoiding titanium dioxide in all filter materials proved to be a key requirement. Fine quartz particulates were collected on prototype filters in a Marple chamber, either open-faced or through PDMs during test runs. The filters were then subjected to MSHA P-7 analysis and the spectrometrically based analytical results for quartz mass were compared to reference measurements. Also, PDM instrumental mass readings were compared to filter gravimetric measurements. Results suggest that the P-7 method is adaptable to variations in filter materials and that quartz dust analysis by the P-7 method when utilizing the new ashable PDM filters can have accuracy and precision within 10% and 4%, respectively. This is within the declared 13% accuracy and 7-10% precision of the P-7 method itself. Instrument mass readings had modest positive bias but met NIOSH accuracy criteria. Continued work with specialized PDM filters is merited, as they are a new type of TEOM sample amenable to ashing analysis of particulates.  相似文献   

2.
All major opencast mining activities produce dust. The major operations that produce dust are drilling, blasting, loading, unloading, and transporting. Dust not only deteriorates the environmental air quality in and around the mining site but also creates serious health hazards. Therefore, assessment of dust levels that arise from various opencast mining operations is required to prevent and minimize the health risks. To achieve this objective, an opencast coal mining area was selected to generate site-specific emission data and collect respirable dust measurement samples. The study covered various mining activities in different locations including overburden loading, stock yard, coal loading, drilling, and coal handling plant. The dust levels were examined to assess miners' exposure to respirable dust in each of the opencast mining areas from 1994 to 2005. The data obtained from the dust measurement studies were evaluated by using analysis of variance (ANOVA) and the Tukey-Kramer procedure. The analyses were performed by using Minitab 14 statistical software. It was concluded that, drilling operations produce higher dust concentration levels and thus, drill operators may have higher incidence of respiratory disorders related to exposure to dust in their work environment.  相似文献   

3.
A monitoring method for diesel particulate matter was published as Method 5040 by the National Institute for Occupational Safety and Health (NIOSH). Organic and elemental carbon are determined by the method, but elemental carbon (EC) is a better exposure measure. The US Mine Safety and Health Administration (MSHA) proposed use of NIOSH 5040 for compliance determinations in metal and nonmetal mines. MSHA also published a rulemaking for coal mines, but no exposure standard was provided. A standard based on particulate carbon is not considered practical because of coal dust interference. Interference may not be a problem if an appropriate size-selective sampler and EC exposure standard are employed. Submicrometer dust concentrations found in previous surveys of nondieselized, underground coal mines were relatively low. If a large fraction of the submicrometer dust is organic and mineral matter, submicrometer EC concentrations would be much lower than submicrometer mass concentrations. Laboratory and field results reported herein indicate the amount of EC contributed by submicrometer coal dust is minor. In a laboratory test, a submicrometer EC concentration of 31 microg m(-3) was found when sampling a respirable coal dust concentration over three times the US compliance limit (2 mg m(-3)). Laboratory results are consistent with surveys of nondieselized coal mines, where EC results ranged from below the method limit of detection to 18 microg m(-3) when size-selective samplers were used to collect dust fractions having particle diameters below 1.5 microm-submicrometer EC concentrations were approximate 7 microg m(-3). In dieselized mines, submicrometer EC concentrations are much higher.  相似文献   

4.
Miners face a variety of respiratory hazards while on the job, including exposure to silica dust which can lead to silicosis, a potentially fatal lung disease. Currently, field-collected filter samples of silica are sent for laboratory analysis and the results take weeks to be reported. Since the mining workplace is constantly moving into new and often different geological strata with changing silica levels, more timely data on silica levels in mining workplaces could help reduce exposures. Improvements in infrared (IR) spectroscopy open the prospect for end-of-shift silica measurements at mine sites. Two field-portable IR spectrometers were evaluated for their ability to quantify the mass of silica on filter samples loaded with known amounts of either silica or silica-bearing coal dust (silica content ranging from 10-200 μg/filter). Analyses included a scheme to correct for the presence of kaolin, which is a confounder for IR analysis of silica. IR measurements of the samples were compared to parallel measurements derived using the laboratory-based U.S. Mine Safety and Health Administration P7 analytical method. Linear correlations between Fourier transform infrared (FTIR) and P7 data yielded slopes in the range of 0.90-0.97 with minimal bias. Data from a variable filter array spectrometer did not correlate as well, mainly due to poor wavelength resolution compared to the FTIR instrument. This work has shown that FTIR spectrometry has the potential to reasonably estimate the silica exposure of miners if employed in an end-of-shift method.  相似文献   

5.
This study compares the ambient air particulate matter (PM10) data of 15 different coal mine environments. For most of these mine environments, the monitoring was carried out by different researchers using respirable dust sampler (RDS) that separates PM10 by centrifugal inertial separation. At two sites — Padmapur and Ghugus (Chandrapur, Maharashtra, India) — mass inertial impaction-based sampler was used for PM10 monitoring. It is observed that the spatiotemporal average value of ambient air PM10 monitored using mass inertial impactor reports relatively higher values (240–372 μg/m3) compared to those monitored using RDS (<227 μg/m3). In order to realize the severity of mine area pollution, it is compared with PM10 values found in an urban area (Delhi, India). It is found that PM10 values in Delhi (using mass inertial impactor) are much higher (300–400 μg/m3) than those reported for the mine environment. The data seems to indicate that the mine environment is relatively cleaner than urban air and therefore raises doubt about the appropriateness of using either mass impactor or RDS for PM10 sampling.  相似文献   

6.
Surface coal mining creates more air pollution problems with respect to dust than underground mining . An investigation was conducted to evaluate the characteristics of the airborne dust created by surface coal mining in the Jharia Coalfield. Work zone air quality monitoring was conducted at six locations, and ambient air quality monitoring was conducted at five locations, for a period of 1 year. Total suspended particulate matter (TSP) concentration was found to be as high as 3,723 μg/m3, respirable particulate matter (PM10) 780 μg/m3, and benzene soluble matter was up to 32% in TSP in work zone air. In ambient air, the average maximum level of TSP was 837 μg/m3, PM10 170 μg/m3 and benzene soluble matter was up to 30%. Particle size analysis of TSP revealed that they were more respirable in nature and the median diameter was around 20 μm. Work zone air was found to have higher levels of TSP, PM10 and benzene soluble materials than ambient air. Variations in weight percentages for different size particles are discussed on the basis of mining activities. Anionic concentration in TSP was also determined. This paper concludes that more stringent air quality standards should be adopted for coal mining areas and due consideration should be given on particle size distribution of the air-borne dust while designing control equipment.  相似文献   

7.
In 1998 the American Conference for Governmental Industrial Hygienists (ACGIH) proposed size selective sampling for wood dust based on the inhalable fraction. Thus the proposed threshold limit values (TLVs) require the use of a sampler whose performance matches the inhalable convention. The Institute of Occupational Medicine (IOM) sampler has shown good agreement with the inhalable convention under controlled conditions, and the Button sampler, developed by the University of Cincinnati, has shown reasonable agreement in at least one laboratory study. The Button sampler has not been previously evaluated under wood working conditions, and the IOM has been shown to sample more mass than expected when compared to the standard closed-face cassette, which may be due to the collection of very large particles in wood working environments. Some projectile particles may be > 100 microm aerodynamic diameter and thus outside the range of the convention. Such particles, if present, can bias the estimates of concentration considerably. This study is part of an on-going research focus into selecting the most appropriate inhalable sampler for use in these industries, and to examine the impact of TLV changes. This study compared gravimetric analyses (National Institute of Occupational Safety and Health Method 0500) of side-by-side personal samples using the Button, IOM, and 37 mm closed-face cassette (CFC) under field-use conditions. A total of 51 good sample pairs were collected from three wood products industries involved in the manufacturing of cabinets, furniture, and shutters. Paired t-tests were run on each sample pair using Statistical Package for the Social Sciences (SPSS) version 10. The IOM and the CFC measured statistically different concentrations (p < 0.0005, n = 16). The IOM and Button measured statistically different concentrations (p = 0.020, n = 12). The Button and CFC did not measure statistically different concentrations of wood dust (p = 0.098, n = 23). Sampler ratios for IOM/CFC pairs ranged from 1.19-19 (median 3.35). Sampler ratios for IOM/Button pairs ranged from 0.49-163 (median 3.15). Sampler ratios for CFC/Button pairs ranged from 0.36-27 (median 1.2). In all cases, higher ratios were associated with higher concentrations. The median relative difference between the IOM's and CFC's is in accord with prior field studies in woodworking environments, and, taken together, the data imply a conversion factor greater than the 2.5 normally applied to CFC results to approximate inhalable values, as measured by the IOM. Raising the limit values by approximately 50% appears warranted for this particular situation of inhalable wood dust measured by the IOM. The IOM/Button and CFC/Button ratios were unexpectedly low, which may be due to the exclusion of very large particles, collected by the IOM and CFC samplers. Further work is required to explain these results.  相似文献   

8.
The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.  相似文献   

9.
In the absence of methods for determining particle size distributions in the inhalable size range with good discrimination, the samples collected by personal air sampling devices can only be characterized by their total mass. This parameter gives no information regarding the size distribution of the aerosol or the size-selection characteristics of different samplers in field use conditions. A method is described where the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood dust particles which are generally large and close to rectangular prisms in shape. Over 200 wood dust samples have been collected in three different wood-products industries, using the traditional closed-face polystyrene/acrylonitrile cassette, the Institute of Occupational Medicine inhalable sampler, and the Button sampler developed by the University of Cincinnati. A portion of these samples has been analyzed to determine the limitations of this method. Extensive quality control measures are being developed to improve the robustness of the procedure, and preliminary results suggest the method has an accuracy similar to that required of National Institute for Occupational Safety and Health (NIOSH) methods. The results should provide valuable insights into the collection characteristics of the samplers and the impact of these characteristics on comparison of sampler results to present and potential future limit values. The NIOSH Deep South Education and Research Center has a focus on research into hazards of the forestry and associated wood-products industry, and it is hoped to expand this activity in the future.  相似文献   

10.
Researchers at the National Institute for Occupational Safety and Health (NIOSH) have long used stationary tapered element oscillating microbalances (TEOMs) in laboratory settings. They have served to assess the mass concentration of laboratory-generated particulates in experimental dust chambers and they provide a reference method for comparison with other particulate-measuring instruments. Current NIOSH research is focused on further adapting TEOM technology as a wearable personal dust monitor (PDM) for coal mining occupations. This investigation's goal is to help identify, quantify, and provide means for resolving certain TEOM-related error. The present research investigated bias caused by thermal effects on filter assemblies. New filters used in the PDM for 8 h tests show an average positive bias of 25.5 microg, while similar tests of equivalent filters used in two 1400A model TEOMs show an average positive bias of 34.3 microg. The derived bias values allow correction of previously collected biased data. Also, pre-heating the filters for 24 h at 46 degrees C shows significant bias reduction, with PDM pre-heated filters subsequently averaging -3.3 microg and 1400A TEOM filters averaging 5.9 microg. On a single-point comparison to gravimetric sampling, a 25.5 microg bias is only significant at low mass loadings. At 2.5 mg, this bias represents a negligible 1% of the mass measurement. If ordinary linear regression is used, the bias is still insignificant. However, if the more valid weighted linear regression is used, it gives more weight to the smaller dependent variable values, which are more impacted by the bias. Consequently, what is 1% bias on a single high-mass value can translate into a larger bias percentage at high-mass values when performing a weighted regression on data that include a large number of low-mass values.  相似文献   

11.
In a previous study, the efficacy of commercial and prototype impactors for sampling diesel particulate matter (DPM) in coal mines was investigated. Laboratory and field samples were collected on quartz-fiber filters and analyzed for organic and elemental carbon. Coal dust contributed a minimal amount of elemental carbon when commercial cascade impactors and prototype impactors, designed by the University of Minnesota (UMN) and the US Bureau of Mines (BOM), were used to collect submicrometer dust fractions. Other impactors were not as effective at excluding coal dust. The impactors evaluated in that study were either not commercially available or were multi-stage, expensive, and difficult to use for personal measurements. A commercial version of the BOM impactor, called the DPM Cassette, was recently introduced by SKC. Tests were conducted to evaluate the performance of the DPM Cassette for measuring diesel-source elemental carbon in the presence of coal dust. Bituminous coals from three mines in two different coal provinces were examined. The dust particle diameters were small and the coal dust contained a high percentage of carbon, thereby giving a worst-case condition for non-anthracite coal mines. Results for the DPM Cassette were essentially identical to those obtained by the BOM impactors in a previous study. At a respirable coal dust concentration of 5.46 mg m(-3), which is 3.8 times the regulatory limit, the DPM Cassette collected only 34 microg m(-3) of coal-source elemental carbon.  相似文献   

12.
The objective of this study was to compare measured concentrations of rubber process dust and rubber fume originating from different sources in the British rubber manufacturing industry. Almost 8000 exposure measurements were obtained from industry-based survey results collected by the British Rubber Manufacturers' Association (BRMA), and covering the years 1977 to 2002, and from a series of small surveys contained in the Health and Safety Executive's (HSE) National Exposure Database (HSE-NEDB) from 1980 to 2002. The analysis investigated temporal trends in the exposure concentrations and the underlying main factors responsible for these changes. Analyses were carried out using hierarchical linear mixed effects models. Average personal exposures to rubber process dust and rubber fumes were respectively a factor 2 and 4 higher for the HSE-NEDB data when compared to data originating from the industry (BRMA data). Personal exposure to rubber process dust decreased on average by 4.1% (95% CI 4.7-3.6) annually for the BRMA data and slightly less at 2.3% (95% CI 5.2-0.7%) per annum for the HSE-NEDB data. Personal exposure to rubber fume also showed a downward temporal trend of 2.9% (95% CI 3.6-2.3%) and 4.8% (95% CI 7.4-2.1%) annually for the BRMA and HSE-NEDB data, respectively. These trends differed considerably between departments. No major changes in the estimated temporal trends in exposure concentrations were observed after including the presence of local exhaust ventilation in the models for any department in the BRMA and HSE-NEDB datasets. Lack of information on the quality and status of the local exhaust ventilation is the most likely explanation for this. In conclusion, even though there were relatively similar downward time trends in both rubber process dust and fume concentrations in both datasets, the source of exposure data was an important determinant of average exposure concentrations present in the British rubber manufacturing industry. Lack of detailed auxiliary information on company size, reason for sampling, measurement strategy and other potentially important determinants of exposure prevented an explanation for the observed differences in exposure level.  相似文献   

13.
Simultaneous measurements of CO and respirable particles (RP) at outdoor network stations and of personal exposure in a sample of twelve volunteers were carried out during the winter and summer season of 1980/81 in order to evaluate how well personal exposure can be assessed from outdoor network station data.The results have shown that personal exposure of our subjects to both CO and RP is in best correlation with exposure at home where subjects spend in the average nearly 70% of their time. While personal exposure to CO can hardly be related to outdoor CO levels, personal exposure to RP is in fair agreement with simultaneously measured outdoor concentrations in winter (but not in summer). A large intercept on WAE axis of the WAE/RP relationship indicates that a considerable part of personal exposure to RP should be attributed to particles which are not of indoor origin. This part does not follow the seasonal and day-to-day changes in outdoor RP concentration and causes a negative, but highly significant correlation between WAE/RP ratio and RP.  相似文献   

14.
A new analytical technique based on DRIFTS spectroscopy has been developed for the specific and sensitive determination of size-fractionated wood dust from 37 mm glass fiber filter samples collected with the Respicon sampler. A translational diffuse reflectance apparatus was modified to accept filter samples by incorporating a special filter holder in the sample stage and a clockwork motor to drive the translational stage during infrared scanning, thus providing an average analysis across the filter face. Filter samples were pre-treated with ethyl acetate to uniformly redeposit dust onto the filter and extract potential chemical interferences. Two absorbance maxima (1251 and 1291 cm(-1)), corresponding to the cellulose content of the wood, were suitable for quantitation of wood dust. Analysis of seven species of wood at 1291 cm(-1) showed an equivalent quantitative response for all species except maple. The response at 1251 cm(-1) was more variable across species but more sensitive for the softwoods. There was a statistically significant effect of particle size on the analytical response, so that analytical standards should be matched to the samples in terms of particle size distribution. Analytical limit of detection was approximately 0.08 mg of wood dust per sample with overall precision of about 6%. Comparison of DRIFTS and gravimetric analyses of 51 pure wood dust samples ranging from about 0.2 to 2 mg yielded a slope of 1.08 and r2 equal to 0.9. Other particulate contaminants common in the industrial wood processing industry showed little or no interference with the determination of wood dust by this method.  相似文献   

15.
Dust from haul and transport roads are the major source of air pollution in opencast coal mining areas. Dust generated during mining operations pollutes air which causes different health problems. Various available techniques are implemented in the field to minimize and control dust in mining areas. However, they are not very effective because dust deposited on road surfaces are not removed by these techniques. For effective control of dust in opencast mining areas, it has to be regularly collected from road surfaces and may be converted into solid form, and subsequently can be used as a domestic fuel considering its physicochemical properties. The present paper describes a comparative study of qualitative and quantitative aspects of road dust samples of four coalfields of India. The pH of the dust was found to be in the range of 5.1–7.7. Moisture, ash, volatile matter, fixed carbon, water-holding capacity, bulk density, and specific gravity of dust samples were found to be in the range of 0.5–3.0%, 45–76%, 12.6–20.0%, 10.2–45.3%, 21.17–31.71%, 1.15–1.70, and 1.73–2.30 g cm−3, respectively. Observing the overall generation and characteristics of coal dust, it is suggested that coal dust from haul and transport roads of mining areas can be effectively collected and used as domestic fuel.  相似文献   

16.
A method has been described previously for determining particle size distributions in the inhalable size range collected by personal samplers for wood dust. In this method, the particles collected by a sampler are removed, suspended, and re-deposited on a mixed cellulose-ester filter, and examined by optical microscopy to determine particle aerodynamic diameters. This method is particularly appropriate to wood-dust particles which are generally large and close to rectangular prisms in shape. The method was used to investigate the differences in total mass found previously in studies of side-by-side sample collection with different sampler types. Over 200 wood-dust samples were collected in three different wood-products industries, using the traditional 37 mm closed-face polystyrene/acrylonitrile cassette (CFC), the Institute of Occupational Medicine (IOM) inhalable sampler, and the Button sampler developed by the University of Cincinnati. Total mass concentration results from the samplers were found to be in approximately the same ratio as those from traditional long-term gravimetric samples, but about an order of magnitude higher. Investigation of the size distributions revealed several differences between the samplers. The wood dust particulate mass appears to be concentrated in the range 10-70 aerodynamic equivalent diameter (AED), but with a substantial mass contribution from particles larger than 100 microm AED in a significant number of samples. These ultra-large particles were found in 65% of the IOM samples, 42% of the CFC samples and 32% of the Button samples. Where present, particles of this size range dominated the total mass collected, contributing an average 53% (range 10-95%). However, significant differences were still found after removal of the ultra-large particles. In general, the IOM and CFC samplers appeared to operate in accordance with previous laboratory studies, such that they both collected similar quantities of particles at the smaller diameters, up to about 30-40 [micro sign]m AED, after which the CFC collection efficiency was reduced dramatically compared to the IOM. The Button sampler collected significantly less than the IOM at particle sizes between 10.1 and 50 microm AED. The collection efficiency of the Button sampler was significantly different from that of the CFC for particle sizes between 10.1 and 40 microm AED, and the total mass concentration given by the Button sampler was significantly less than that given by the CFC, even in the absence of ultra-large particles. The results are consistent with some relevant laboratory studies.  相似文献   

17.
A passive sampling device, developed for personal monitoring of airborne dust levels in industry, has been tested as a site sampler in the urban environment. The device weighs approximately 15g and the essential sampling element is a small disc of electret material (polymer carrying a permanent electric charge). During use it captures particles by electrical attraction, at a rate that depends upon their electrical mobility, but which is independent of the rate at which air flows past the sampler. It collects measurable quantities of particulate, though the sample size tends to be small and correlation with results from conventional samples has not yet been established. Samplers have been exposed to urban particulate for periods of up to seven days, without the electret suffering unacceptable loss of electric charge. It has been shown to be potentially useful for long-term monitoring, a situation in which dispensing with a power source is particularly useful. Being small, the passive sampler is easy to hide or camouflage. It has potential for multiple simultaneous site sampling and for monitoring personal environmental exposure.  相似文献   

18.
Symptoms such as shortness of breath and cough have been noted in woodworking facilities even where wood dust itself is well-controlled. Suspicion has fallen on other possible contaminants in the workplace atmosphere, including bacterial endotoxin. A few studies have indicated potentially high endotoxin exposure with exposure to fresh wood in sawmills and in the production of fiberboard and chipboard, but fewer studies have been carried out on exposure to endotoxin in dry wood work, for example in joineries. A study of the endotoxin content of airborne wood dust samples from US woodworking facilities is presented, from the re-analysis of samples which previously had been taken to establish mass collection relationships between the IOM sampler, the closed-face 37 mm plastic cassette (CFC) sampler and the Button sampler. Endotoxin was strongly correlated with total dust, but the endotoxin content of a few fresh wood samples was found to be up to ten times higher per unit of wood dust than for dried-wood samples, and this difference was significant. No long-term time-weighted average sample exceeded the recommended limit value of 50 EU m(-3) (EU, endotoxin units)used in the Netherlands, although a number of the IOM samples came close (seven samples or 44% exceeded 20 EU m(-3)) and one short-term (48 minute) sample registered a high value of 73 EU m(-3). The geometric mean concentration from the IOM samples (11 EU m(-3)) is within the range of geometric means found from Australian joineries (3.7-60, combined: 24 EU m(-3)). In contrast, the corresponding values from the CFC (3.6 EU m(-3)), and the Button sampler (2.1 EU m(-3)) were much lower and no samples exceeded 20 EU m(-3). Endotoxin is likely only to be a significant problem in working with dried woods when associated with very high dust levels, where the wood dust itself is likely to be a cause for concern. The results from the few samples in this study where fresh wood was being worked were similar to results from other studies involving fresh woods. The agreement between these studies is encouraging given the difficulties of endotoxin analysis and the wide variation often expected between different laboratories.  相似文献   

19.
Every mine in India has to obtain environmental clearance fromthe Govt. Air pollution is one of the most important parametersto be considered in preparing an EIA. However, there is no welldefined method for predicting thr air pollution impact due tomining. Increasing trend of opencast (O/C) mining leads toproduction of huge quantities of dust. Emission factor data havebeen utilised to quantify the generation of dust. The projectunder study is one of the largest opencast project (OCP) forcoking coal. The main sources of air pollution have beenidentified. The rate of emission per unit of a given activityknown as an emission factor has been utilised, taking localfactors into account. It has been estimated that due to topsoilremoval, overburden (O/B) removal, extraction of coal, sizereduction generated 7.8 t of dust per day. Wind erosiongenerated 1.6 t of dust per day and the whole operationproduced dust which accounted for 9.4 mt/day. They cause airpollution in the work zone and surrouding locations. Themethodology adopted may be used to quantify generation for otherprojects also.  相似文献   

20.
Portable X-ray fluorescence (XRF) technology may provide faster turn-around without compromising accuracy when assessing personal exposures to metals such as lead, but it has only been tested in limited field environments. This study is part of a series, where various types of sampler are used to collect airborne lead in different environments for presentation to a portable XRF analyzer. In this case personal samples were taken at a manufacturer of solder alloys consisting mainly of lead and tin, using the closed-face 37 mm cassette (CFC), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. Following XRF analysis the samples were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP). The internal surfaces of CFC's and 25 mm open-face cassettes were also wiped, and the wipes analyzed for lead to assess wall-losses in these two samplers. Analysis of all elements present is useful to ascertain contributions to matrix interference effects. In addition to lead, other metals such as tin, copper, iron, silver, cadmium and antimony were also detected in some or all of the samples by ICP analysis, but only copper and iron could be determined using the XRF analyzer under test. After the removal of a few outliers, all five samplers gave good correlations (r(2) > 0.9) between the two analytical methods over the entire range of found lead mass, which encompassed both the action level and the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects, particularly from tin, which was the most common element after lead. The average of three XRF readings across filters from the GSP samplers gave the best results with 96.7% of results within +/-25% and 100% within +/-30% of the associated ICP values. Using the center reading only was almost as good with 90.0% of results within +/-25% and 96.7% within +/-30% of the associated ICP values, and results can be obtained faster with a single reading. The use of an algorithm developed by OSHA for three readings from the CFC filter samples gave the next best results with 93.3% of XRF results within +/-25% of the corresponding ICP values. However, analysis of wipes from the interior of the cassettes indicated a substantial loss of sample to the walls, and even larger wall-losses were encountered in the 25 mm open-face cassette. Neither this latter sampler nor the IOM or button sampler met the 95% criterion, even for +/-30% accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号