首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study was to evaluate the bacterial contamination level and to determine the antibiotic susceptibility of the isolated bacteria from dental unit waterlines (DUWLs) in Istanbul. Bacterial quality of DUWLs is very important, as patients and dental staff are regularly exposed to water and aerosols generated by the unit. If opportunistic pathogens such as Staphylococcus aureus, Pseudomonas aeruginosa, and Legionella pneumophila are present in DUWLs, patient and dental staff can be infected. One hundred water samples were collected from high-speed drills and input waters from 50 dental units. Aerobic heterotrophic bacteria counts and the presence of Legionella, Pseudomonas, oral streptococci, and Staphylococcus were investigated in dental unit waters and aerosol samples. In addition, the antibiotic susceptibility of the isolated and identified bacteria from DUWLs was examined. This research found that 37 out of 50 dental unit water samples exceeded the American Dental Association’s limit of 200 colony-forming units (CFU)/mL?1. Legionella, oral streptococci, and S. aureus were not detected in any water or aerosol samples, but P. aeruginosa was isolated in three DUWLs. Also, Pseudomonas and Staphylococcus were found in water and aerosol samples. Cefoperazone, ofloxacin, gentamicin, ciprofloxacin, and piperacillin were the most effective antibiotics against the isolated bacteria from DUWLs.  相似文献   

2.
The water used in dental unit waterlines (DUWLs) acts as a coolant for the high-speed equipment and as an irrigant during dental treatments. There are kind of water tanks. DUWLs provide a favorable environment for microbial biofilm and multiplation primarily due to the high surface in the tubing and the character of fluid dynamics in narrow, smooth-walled waterlines. Biofilms can harbour opportunist pathogens such as Legionella sp., Pseudomonas sp. Several studies have shown that DUWLs have high levels of microbial contamination. Presence of high level of microbial contamination is an important problem for dentists and dental patients who are immunocompromised. We collected water samples from DUWLs of 20 private dental offices. We have determined that only 2 (3.4%) out of 59 dental unit water samples were found to meet the standard (<200 CFU.ml(-1)) for DUWLs water quality by American Dental Association (ADA). Of the 59 water samples examined, 14 (24%) were positive for Pseudomonas sp. and 18 (30.5%) were positive for fungi. The most common 14 bacterial strains and seven fungi were isolated. Of bacterial strains, 57.1% were identified: Majority of the bacterial species isolated from our samples was identified as Pseudomonas fluorescens, Pasteurella haemolytica, Photobacterium damsela, Ochrobacter anthropi, Moraxella sp., Aspergillus flavus, Penicillium expansum. Legionella sp. were not detected in all water samples.  相似文献   

3.
Safety of patients and dental personnel requires the appropriate microbiological water quality in dental units. During treatment, patients and dental workers are exposed both to direct contact with bacteria-contaminated water in the form of splatter and with contaminated water aerosol emitted during work by unit handpieces, including rotating and ultrasonic instruments. The aim of the study was to determine the qualitative and quantitative contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria. The study material included water sampled from 107 dental unit reservoirs located in dental surgeries of public health centres. Conventional microbiological methods were used to identify microorganisms. The study shows that the contamination of water in dental unit reservoirs with aerobic and facultative anaerobic bacteria is commonplace. The mean concentration of mesophile bacteria in dental unit reservoir water exceeded 1.1?×?105 cfu/ml. The prevailing species were Gram-negative bacteria of the families Burkholderiaceae, Pseudomonadaceae, Ralstoniaceae and Sphingomonadaceae. The most numerous bacteria were Ralstonia pickettii, constituting 49.33 % of all the identified aerobic and facultative anaerobic bacteria. Among Gram-positive rods, the most numerous were bacteria of the genus Brevibacterium (5.83 %), while the highest percentage shares (13.25 %) of all Gram-positive microorganisms were found for Actinomyces spp. The study confirms the necessity of regular monitoring of microbial contamination of dental unit waterlines (DUWL) and use of various water treatment procedures available to disinfect DWUL.  相似文献   

4.
Although bacterial contamination is widely researched in dental unit water systems, we have been unable to find any published reports to date about the presence and distribution of sulphate-reducing bacteria (SRB) in dental unit waterlines (DUWLs). The aim of this study was to evaluate microbial contamination and to determine the presence and distribution of SRB in DUWLs. One hundred twenty-three water samples were collected from the air–water syringes, high-speed drills and water sources from 41 dental units in Istanbul, Turkey. The counts of aerobic heterotrophic bacteria and SRB were investigated in the water samples. In addition, the presence of free-living amoebae (FLA) was examined. In this work, we evaluated microbial contamination and reported for the first time the distribution of SRB in DUWLs. We determined that only ten out of 123 water samples were able to meet the American Dental Association’s limit (≤200 CFU ml − 1). SRB were observed in 102 out of 123 samples (82.9%). In addition, SRB were detected in all of the air–water syringes and high-speed drills. FLA were established in 103 out of 123 samples (83.7%).  相似文献   

5.
The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium–low level of bacterial contamination (50–500 CFU/m3) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.  相似文献   

6.
The aims of the present study were to determine the levels of bioaerosols including airborne culturable bacteria (total suspended bacteria, Gram-positive bacteria, Staphylococcus, Staphylococcus aureus, methicillin-resistant S. aureus (MRSA), and Gram-negative bacteria), fungi, endotoxin, and viruses (influenza A, influenza B, respiratory syncytial virus types A/B, parainfluenza virus types 1/2/3, metapnemovirus, and adenovirus) and their seasonal variations in indoor air of residential apartments. Of the total suspended bacteria cultured in an indoor environment, Staphylococcus was dominant and occupied 49.0 to 61.3 % of indoor air. Among Staphylococcus, S. aureus were detected in 100 % of households' indoor air ranging from 4 to 140 CFU/m3, and 66 % of households were positive for MRSA ranging from 2 to 80 CFU/m3. Staphylococcus and S. aureus concentrations correlated with indoor temperature (adjusted β: 0.4440 and 0.403, p?<?0.0001). Among respiratory viruses, adenovirus was detected in 14 (14 %) samples and influenza A virus was detected in 3 (3 %) samples regarding the indoor air of apartments. Adenovirus concentrations were generally higher in winter (mean concentration was 2,106 copies/m3) than in spring (mean concentration was 173 copies/m3), with concentrations ranging between 12 and 560 copies/m3. Also, a strong negative correlation between adenovirus concentrations and relative humidity in indoor air was observed (r?=??0.808, p?<?0.01). Furthermore, temperature also negatively correlated with adenovirus concentrations (r?=??0.559, p?<?0.05).  相似文献   

7.
This study was conducted to assess potential human health risks presented by pathogenic bacteria in a protected multi-use lake-reservoir (Lake Ma Vallée) located in west of Kinshasa, Democratic Republic of Congo (DRC). Water and surface sediments from several points of the Lake were collected during summer. Microbial analysis was performed for Escherichia coli, Enterococcus (ENT), Pseudomonas species and heterotrophic plate counts. PCR amplification was performed for the confirmation of E. coli, ENT, Pseudomonas spp. and Pseudomonas aeruginosa isolated from samples. The results reveal low concentration of bacteria in water column of the lake, the bacterial quantification results observed in this study for the water column were below the recommended limits, according to WHO and the European Directive 2006/7/CE, for bathing water. However, high concentration of bacteria was observed in the sediment samples; the values of 2.65?×?103, 6.35?×?103, 3.27?×?103 and 3.60?×?108 CFU g?1 of dry sediment for E. coli, ENT, Pseudomonas spp. and heterotrophic plate counts, respectively. The results of this study indicate that sediments of the Lake Ma Vallée can constitute a reservoir of pathogenic microorganisms which can persist in the lake. Possible resuspension of faecal indicator bacteria and pathogens would affect water quality and may increase health risks to the population during recreational activities. Our results indicate that the microbial sediment analysis provides complementary and important information for assessing sanitary quality of surface water under tropical conditions.  相似文献   

8.
Soil and air samples of seven different localities around Hamitabat Thermic Power Plant, 10 km far away from Luleburgaz/Kirklareli (Turkey), were taken between the years 2003 and 2004 with seasonal intervals. The samples were brought to the laboratory and their microfungal identifications were done. From the air samples, 737 microfungi colonies were isolated comprising 26 species belonging to eight genera. From soil samples, 170.6 × 104 colony-forming unit (CFU)/g was isolated from 33 species belonging to 16 genera. The most isolated genus from air samples was Alternaria (324 CFU, 43.96%), followed by Cladosporium (208 CFU, 25.52%) and Phoma (44 CFU, 5.40%). Penicillium was the most isolated genus from the soil samples with a value of 560,000 CFU/g (32.8%), followed by Fusarium (226,000 CFU/g, 13.12%) and Aspergillus (154,000 CFU/g, 9.03%). Among these species, Alternaria citri and Alternaria alternata are the most abundant species in air with 164 and 107 CFU, respectively, whereas Fusarium graminearum and Penicillium citrinum are the most abundant species in soil with CFU per gram values of 17.8 × 104 and 1.3 × 105. Correlation analysis was applied to determine whether or not there was a relationship between colony number of isolated fungal genera and meteorological factors. Some parameters of soil samples’ incontent during the research period were calculated using a computer analysis program. From the air samples, a positive correlation was found between relative humidity and Alternaria colonial counts and Cladosporium spore counts (r?=?0.912 and r?=?1.000, respectively). Similarly, with the analysis of soil samples, a positive correlation between colonial counts of Alternaria and soil pH and a positive correlation between colonial counts of Aspergillus and Penicillium and salt percentage concentration of soil were found.  相似文献   

9.
To study the distribution of Aspergillus spp. in outdoor and indoor air of asthmatic patients’ houses, as well as a review on the health effects of exposure to indoor Aspergillus. Open plates containing malt extract agar media were used to isolate fungi from the indoor (n?=?360) and outdoor (n?=?180) air of 90 asthmatic patients’ houses living in Sari City, Iran. Plates were incubated at room temperature for 7–14 days. Cultured Aspergillus spp. were identified by standard mycological techniques. All culture plates grew fungi, a testament to the ubiquitous nature of fungal exposure. Cladosporium spp. (29.2%), Aspergillus spp. (19.0%), and Penicillium spp. (18.3%) were most common inside the houses while Cladosporium spp. (44.5%), Aspergillus spp. (12.4%), and Alternaria spp. (11.1%) were most common outside the houses. Aspergillus flavus (30.1%) and A. fumigatus (23.1%) are the most commonly isolated species in indoor air. Aspergillus flavus (44.5%) and A. fumigatus (42.6%) were the most prevalent Aspergillus spp. outside. The most colony numbers of Aspergillus were isolated from kitchens (30.4%) and the least from bedrooms (21.1%). Aspergillus flavus was the most prevalent specie in all sampled rooms except in the kitchen where A. fumigatus was the most common. Aspergillus flavus is the most prevalent species among the Aspergillus spp. in the indoor and outdoor of a warm climate area. In these areas, A. flavus can be a major source of allergen in the air. Therefore, minimizing indoor fungal exposure could play an important role in reducing allergic symptoms in susceptible persons.  相似文献   

10.
Indoor air quality in health care facilities is a major public health concern, particularly for immunocompromised patients who may be exposed to microbiological contaminants such as molds, mycotoxins, endotoxins, and (1,3)-ß-D-glucans. Over 2 years, bioaerosols were collected on a monthly basis in a cancer treatment center (Centre F. Baclesse, Normandy, France), characterized from areas where there was no any particular air treatment. Results showed the complexity of mycoflora in bioaerosols with more than 100 fungal species identified. A list of major strains in hospital environments could be put forward due to the frequency, the concentration level, and/or the capacity to produce mycotoxins in vitro: Aspergillus fumigatus, Aspergillus melleus, Aspergillus niger, Aspergillus versicolor, Cladosporium herbarum, Purpureocillium lilacinum, and Penicillium brevicompactum. The mean levels of viable airborne fungal particles were less than 30.530 CFU per m3 of air and were correlated to the total number of 0.30 to 20 μm particles. Seasonal variations were observed with fungal particle peaks during the summer and autumn. Statistical analysis showed that airborne fungal particle levels depended on the relative humidity level which could be a useful indicator of fungal contamination. Finally, the exposure to airborne mycotoxins was very low (only 3 positive samples), and no mutagenic activity was found in bioaerosols. Nevertheless, some fungal strains such as Aspergillus versicolor or Penicillium brevicompactum showed toxigenic potential in vitro.  相似文献   

11.
Using the membrane filtration technique to count total coliform (TC), fecal coliform (FC) and fecal streptococci (FS), the microbiological water quality of the Mfoundi River and four of its representative tributaries at Yaoundé, Cameroon, was assessed for human use and contact. Sampling was conducted so as to examine the potential origin of fecal contamination and how rainfall affects the measured concentrations of indicators organisms. Our results revealed that waters were not safe for human use or primary contact according to the standards for water quality established by the Word Health Organization (WHO). Indeed, these waters exhibited high concentrations of TC (Mean ± SD=5.6 × 108 ± 2.5 × 106 CFU/100 ml), FC (Mean ± SD=6.8 × 105 ± 2.4 × 103 CFU/100 ml) and FS (Mean ± SD=7.3 × 105 ± 2.1 × 103 CFU/100 ml) that varied with the sampling sites and points. FC/FS ratio suggested that this contamination was more from warm-blooded animals than humans and correlation analysis points to the role of rainfall as a contributing factor, which enhanced the bacterial numbers detected. We conclude that there is a great potential risk of infection for users of waters from the Mfoundi River and its tributaries at Yaoundé.  相似文献   

12.
A total of 144 isolates of Pseudomonas spp. (48 each from the Yamuna River water, wastewater irrigated soil and groundwater irrigated soil) were tested for their resistance against certain heavy metals and antibiotics. Minimum inhibitory concentrations (MICs) of Hg2?+?, Cd2?+?, Cu2?+?, Zn2?+?, Ni2?+?, Pb2?+?, Cr3?+? and Cr6?+? for each isolate were also determined. A maximum MIC of 200 ??g/ml for mercury and 3,200 ??g/ml for other metals were observed. The incidences of metal resistance and MICs of metals for Pseudomonas isolates from the Yamuna water and wastewater irrigated soil were significantly different to those of groundwater irrigated soil. A high level of resistance against tetracycline and polymyxin B (81.2%) was observed in river water isolates. However, 87.5% of Pseudomonas isolates from soil irrigated with wastewater showed resistance to sulphadiazine, whereas 79.1% were resistant to both ampicillin and erythromycin. Isolates from soil irrigated with groundwater exhibited less resistance towards heavy metals and antibiotics as compared to those of river water and wastewater irrigated soil. Majority of the Pseudomonas isolates from water and soil exhibited resistance to multiple metals and antibiotics. Resistance was transferable to recipient Escherichia coli AB2200 strains by conjugation. Plasmids were cured with the curing agent ethidium bromide and acridine orange at sub-MIC concentration.  相似文献   

13.
Leachate and groundwater samples were collected from Gazipur landfill-site and its adjacent area to study the possible impact of leachate percolation on groundwater quality. Concentration of various physico-chemical parameters including heavy metal (Cd, Cr, Cu, Fe, Ni, Pb and Zn) and microbiological parameters (total coliform (TC) and faecal coliform (FC)) were determined in groundwater and leachate samples. The moderately high concentrations of Cl, NO 3, SO2− 4, NH+ 4, Phenol, Fe, Zn and COD in groundwater, likely indicate that groundwater quality is being significantly affected by leachate percolation. Further they proved to be as tracers for groundwater contamination. The effect of depth and distance of the well from the pollution source was also investigated. The presence of TC and FC in groundwater warns for the groundwater quality and thus renders the associated aquifer unreliable for domestic water supply and other uses. Although some remedial measures are suggested to reduce further groundwater contamination via leachate percolation, the present study demand for the proper management of waste in Delhi.  相似文献   

14.
This paper presents information about airborne mesophilic bacteria in the indoor and outdoor air of child day-care centers (CDCCs) in the city of Edirne, Turkey. Air samples were collected using the Petri plate gravitational settling method from the indoor and outdoor air of CDCCs. Counts of airborne bacteria were measured as colony forming units (CFU) collected by gravity onto Brain Heart Infusion Agar plates (with 5% sheep blood). Samples were taken monthly over a period of 12 months between January and December 2004. A total of 3,120 bacteria colonies were counted on 192 Petri plates. Four groups of culturable bacteria were identified: Gram-positive cocci, Gram-positive bacilli, endospore-forming Gram-positive bacilli, and Gram-negative bacteria. Airborne Gram-positive bacteria were the most abundant at more than 95% of the measured population. While Gram-positive cocci were more common in indoor environments, Gram-positive bacilli were more dominant in outdoor air. Bacteria commonly isolated from CDCCs were identified at a genus level. Staphylococcus (39.16%), Bacillus (18.46%), Corynebacterium (16.25%), and Micrococcus (7.21%) were dominant among the genera identified in the present study. The dominant genera identified in the day-care centers were Staphylococcus, Micrococcus, and Corynebacterium for indoor air and Bacillus, Corynebacterium, and Staphylococcus for outdoor air. Staphylococcus, Streptococcus, Bacillus, and Corynebacterium genera were found in samples from every month. Bacterial colony counts were compared by sampling location (indoors and outdoors), seasons, and meteorological factors. We found negative correlations between the monthly total outdoor bacterial counts and the sampling day’s average relative humidity and average rainfall, and the monthly average rainfall. Fluctuations in bacterial counts in different seasons were observed.  相似文献   

15.
Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers, corroborating the increased exposure to risk factors, such as fungal load and their metabolites. This study aimed to determine the occupational exposure threat due to fungal contamination caused by the toxigenic isolates belonging to the complex of the species of Aspergillus flavus and also isolates from Aspergillus fumigatus species complex. The study was carried out in seven Portuguese poultries, using cultural and molecular methodologies. For conventional/cultural methods, air, surfaces, and litter samples were collected by impaction method using the Millipore Air Sampler. For the molecular analysis, air samples were collected by impinger method using the Coriolis μ air sampler. After DNA extraction, samples were analyzed by real-time PCR using specific primers and probes for toxigenic strains of the Aspergillus flavus complex and for detection of isolates from Aspergillus fumigatus complex. Through conventional methods, and among the Aspergillus genus, different prevalences were detected regarding the presence of Aspergillus flavus and Aspergillus fumigatus species complexes, namely: 74.5 versus 1.0 % in the air samples, 24.0 versus 16.0 % in the surfaces, 0 versus 32.6 % in new litter, and 9.9 versus 15.9 % in used litter. Through molecular biology, we were able to detect the presence of aflatoxigenic strains in pavilions in which Aspergillus flavus did not grow in culture. Aspergillus fumigatus was only found in one indoor air sample by conventional methods. Using molecular methodologies, however, Aspergillus fumigatus complex was detected in seven indoor samples from three different poultry units. The characterization of fungal contamination caused by Aspergillus flavus and Aspergillus fumigatus raises the concern of occupational threat not only due to the detected fungal load but also because of the toxigenic potential of these species.  相似文献   

16.
In Taiwan, the immediate health care requirements of students and faculty members are satisfied by on-campus medical service centers. The air quality within these centers should comply with the guidelines laid down by the Taiwan Environmental Protection Agency (EPA). Accordingly, this study performed an experimental investigation into the efficiency of various chlorine dioxide applications in disinfecting a local student health center (SHC). The air quality before and after disinfection were evaluated in terms of the bioaerosol levels of bacteria and fungi. The average background levels of bacteria and fungi before disinfection were found to be 1,142 ± 455.4 CFU/m3 and 520 ± 442.4 CFU/m3, respectively. Chlorine dioxide (0.3 mg/m3) was applied using three different methods, namely a single, one-off application, multiple applications within a single day, and regular (daily) applications. Among the three disinfection methods, the regular application method was found to yield a high disinfection efficiency for both bacteria and fungi, i.e., 6.5 ± 0.7% and 4.2 ± 0.3%, respectively. The average residual bacteria and fungi levels after regular daily interval disinfection were 318.8 ± 51.5 CFU/m3 and 254.0 ± 43.8 CFU/m3, respectively. Therefore, the results suggest that the air quality guidelines prescribed by the Taiwan EPA for SHCs and other healthcare facilities can best be achieved by applying chlorine dioxide at regular (daily) intervals.  相似文献   

17.
This study assessed if the use of sterol demethylase inhibitor fungicides in vineyard production can induce resistance to azoles in Aspergillus strains and if it can induce selection of resistant species. We also tried to identify the Aspergillus species most prevalent in the vineyards. Two vineyards from northern Portugal were selected from “Vinhos Verdes and “Douro” regions. The vineyards were divided into plots that were treated or not with penconazole (PEN). In each vineyard, air, soil, and plant samples were collected at three different times. The strains of Aspergillus spp. were isolated and identified by morphological and molecular techniques. We identified 46 Aspergillus section Nigri, eight Aspergillus fumigatus, seven Aspergillus lentulus, four Aspergillus wentii, two Aspergillus flavus, two Aspergillus terreus, one Aspergillus calidoustus, one Aspergillus westerdijkiae, one Aspergillus tamarii, and one Eurotium amstelodami. Aspergillus strains were evaluated for their susceptibility to medical azoles used in human therapy (itraconazole, posaconazole, and voriconazole) and to agricultural azoles (PEN) used in the prevention and treatment of plant diseases. The isolates showed moderate susceptibility to voriconazole. We did not observe any decrease of susceptibility to the medical azoles tested throughout the testing period in any of the treated plots, although some of the resistant species were isolated from there.  相似文献   

18.
This study was designed to evaluate the measuring range and lowest limit of detection of Bacillus endospores in the ambient room air when the Sartorius MD8 sampler, and two different culture methods for bacterial enumeration were used. Different concentrations of bioaerosol were generated inside the test chamber filled with either the high-efficiency particulate air (HEPA)-filtered air or with the ambient room air. The detection of endospores in the HEPA-filtered air was achievable: (1) when they were aerosolized at a concentration above 7.56?×?103 CFU/m3 and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 4.00?×?102 CFU/m3 and analyzed with pour plate method. The detection of endospores in the ambient room air was possible: (1) when they were aerosolized at a concentration above 9.1?×?103 CFU/m3 and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 5.6?×?102 CFU/m3 and analyzed with pour plate method. The microorganisms present in the ambient room air interfere with precise quantification of Bacillus endospores when their concentration is relatively low. The results of this study may be helpful in critical assessment of the results obtained from monitoring the air for bacterial endospores.  相似文献   

19.
Pathogenic and/or opportunistic fungal species are major causes of nosocomial infections, especially in controlled environments where immunocompromised patients are hospitalized. Indoor fungal contamination in hospital air is associated with a wide range of adverse health effects. Regular determination of fungal spore counts in controlled hospital environments may help reduce the risk of fungal infections. Because infants have inchoate immune systems, they are given immunocompromised patient status. The aim of the present study was to evaluate culturable airborne fungi in the air of hospital newborn units in the Thrace, Marmara, Aegean, and Central Anatolia regions of Turkey. A total of 108 air samples were collected seasonally from newborn units in July 2012, October 2012, January 2013, and April 2013 by using an air sampler and dichloran 18% glycerol agar (DG18) as isolation media. We obtained 2593 fungal colonies comprising 370 fungal isolates representing 109 species of 28 genera, which were identified through multi-loci gene sequencing. Penicillium, Aspergillus, Cladosporium, Talaromyces, and Alternaria were the most abundant genera identified (35.14, 25.40, 17.57, 2.70, and 6.22% of the total, respectively).  相似文献   

20.
Natural spring water has unique properties, as it is rich in minerals that are considered to be beneficial to human health. A survey of the microbiological quality of natural spring water was conducted to assess possible risks from the consumption of the water by visitors in recreational mountain areas located in Seoul, South Korea. The densities of total coliforms and Escherichia coli were measured during the spring and the summer of 2002 to investigate the presence of coliform bacteria in the drinking spring waters. Total coliforms were detected in all samples and the mean density of total coliforms was up to a maximum of 228 CFU/mL. Detectable E. coli was found in 78% of all samples and the mean densities of E. coli varied from a minimum of 0 CFU/mL to a maximum of 15 CFU/mL in all samples. Malfunctioning septic systems and wildlife population appear to be the main source of E. coli contamination. Presence of E. coli in natural spring water indicates potential adverse health effects for individuals or populations exposed to this water. The fecal contaminated spring water may present an unacceptable risk to humans if it is used as raw drinking water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号