首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Electrostatic forces have been shown to significantly enhance the collection efficiency of cyclones. In this paper, an analytic model will be developed for the effect of an applied electric field on charged particle trajectories within a laminar, two-dimensional vortical flow. Boundary conditions for particle injection are developed and collection efficiencies are predicted.  相似文献   

2.
A study of the enhancement of the collection efficiency of granular bed filters by electrical means is reported. By applying electric fields of a few kV/cm (DC or AC) across a bed of insulating granules, the efficiency for submicron charged aerosol is greatly increased, to the point where the efficiency minimum normally observed with such filters in the size range 0.1–1 μm is removed. The performance of such filters is explored as a function of granule size, applied field, face velocity and charge state of the entering aerosol with both a bench-scale flow system (to 40 ft3/min; 1.1 m3/min) and a wind tunnel (to 600 ft3/min; 17 m3/min). Some theoretical estimates are made to identify the most likely physical mechanism of electrical enhancement, and a number of potential application possibilities are discussed.  相似文献   

3.
An experimental apparatus has been constructed to investigate aerosol filtration by a cocurrent moving granular bed filter (CMGBF). In a CMGBF, aerosol passes downward through a descending bed of dirty granules while clean granules are added continously at the bed top. The effect of an intergranular dust deposit on penetration in a CMGBF was investigated in a 24 factorial experiment in which the control variables were superficial gas velocity (100 and 250 mm/s), bed depth (130 and 230 mm), granule size (2.1 and 2.7 mm), and the intergranular dust deposit expressed as percent by weight of collected dust in the bed (1% and 5%). All tests were conducted at ambient temperature and pressure using resuspended utility boiler fly ash as the test aerosol.Mass penetration data identified two major penetration mechanisms: (1) straight through penetration and (2) reentrainment due to granular motion. A static, intergranular dust deposit produced high filtration efficiency (>99%) at the low superficial velocity. When the bed was moving, reentrainment of collected dust was significant and accounted for about three-quarters of the penetrating dust. Particle size analyses reveal that the two penetration mechanisms are size dependent. Most particles larger than about one micrometer in diameter that penetrate the CMGBF do so by reentrainment after being collected initially. Virtually no particles smaller than about 0.3 μm in diameter penetrate by reentrainment; when these small particles penetrate, they pass straight through without being collected.  相似文献   

4.
A numerical simulation code has been developed to analyze the coupled electro-aerodynamic phenomena within an electrostatic precipitator operated in both the positive and negative corona modes. The space charge and current densities, as well as the static and space charge components of the electric field, are first obtained using the known cross-sections for ionization and negative ion formation. Data includes the effects of fluid flow. The above quantities (except the static field) are then corrected in a subsequent iteration for the presence of dust particles of known size distribution, charges predominantly by the field charging mechanism. The precipitator collection efficiency is calculated from the trajectories of the charged dust particles. For theory comparison, the collection efficiencies of model precipitators were measured by light-scattering techniques using oil drops as test particles. The variation of efficiency with wire-to-wire spacing will be discussed as a case study.  相似文献   

5.
A model for simulating the dispersion processes of 137Cs and 239,240Pu in the Alborán Sea is described. The model consists of two hydrodynamic models: a 2D depth-averaged model and a two-layer model which provide tidal and geostrophic currents, respectively; a sediment transport model which provides suspended particle concentrations and sedimentation rates over the domain; and the radionuclide dispersion model including interactions of dissolved radionuclides with suspended particles and bed sediments. These processes are formulated using kinetic transfer coefficients. The hydrodynamic and sediment models are run and validated in advance, and their results are then used to simulate the dispersion of 137Cs and 239,240Pu, which are introduced from atmospheric fallout. Radionuclide concentrations in the water column and distributions in bed sediments have been compared with measurements in the sea. Both set of data are, in general, in agreement. The model has also been applied to calculate radionuclide fluxes through the Strait of Gibraltar. These computed fluxes have been compared with previous estimations as well.  相似文献   

6.
A pilot field study was conducted with nine members of the general public to measure carbon monoxide exposure using personal monitors. The principal study objectives were to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. Integrated carbon monoxide exposure was monitored and recorded according to type of activity such as “commuting” or “at work” for approximately 45 days by each subject. All subjects except one were able to handle both the equipment and data recording requirements with no significant problems. Actual data recording responsibilities consumed less than 10 min daily. The data consisted of 355 person-days each over 6-h duration, and weekdays only, from which 8-h average personal exposure levels could be computed. The 9 ppm (μL/L) ambient air quality standard was exceeded on 22 person-days. Elevated carbon monoxide concentrations during the commuting activity were frequently associated with the exceedences.  相似文献   

7.
A new particle collection technique is analyzed and presented for its potential application in a high temperature, high pressure gas cleaning system. The technique is based on the collision and the aglomeration phenomena among the coal-ash particles when the cyclone is operated near the coal-ash fusion temperature. The percent increase of agglomeration rate is estimated by mathematical modeling for particles smaller than five microns in diameter. Particulate collection efficiency with or without agglomeration is presented. Experimental results in a high temperature cyclone are presented. The output dust loading varied from 0.025 to 5 grains per cubic foot (0.057–11 g/m3) as the input dust loading is increased from 4 to 35 grains per cubic foot (9.2–80g/m3) of gas flow.  相似文献   

8.
The statistical mechanics of particles at the surface of a dust deposit are presented as a step towards a microscopic theory of electrostatic precipitation. The paper consists of three major divisions: (1) field induced entrainment, (2) particle condensation at the surface, and (3) hydrodynamic limits on precipitation.In the first part of this paper, the entrainment of dust from surfaces by electrostatic forces was considered as a simple Markov process. A choice of x−1 for the dependence of the adhesive potential (van der Waals particle attraction) led to an exponential emission rate in the Kramers-Chandrasekhar approximation. This result suggested a simple experimental procedure for determining the adhesive properties of the dust. In addition it was found that both thermal Brownian and particle-deposit collisions contribute to the entrainment.In the second part, the precipitation problem was discussed in terms of a two-dimensional Ising model. The Markovian assumption demanded that the efficiency of the electrostatic precipitator be divided into a product of factors depending on particle migration and condensation in the two-dimensional surface. From this perspective a new collection criterion was established and the importance of particle collisions at the surface of the deposit was demonstrated.Finally, in the third part the role of bulk fluid flows in particle condensation and migration was addressed. The superficial gas flow and secondary flow were found to introduce anisotropy into the Ising lattice and also to enhance the mean particle energy at the surface. The Navier Stokes Equation was numerically integrated for the case of a wire-plate type corona. Plots of the stream function and gas velocity profile were presented and these suggested the existence of a lower limit on the shear stress that acts on surface particles.  相似文献   

9.
The area of ambient air sampling and its inherent problems and current goals are discussed in general. In particular, recently completed tests of the collection effectiveness of the Rocky Flats Hi-Volume Sampler are compared to previously completed tests of the Standard EPA Hi-Volume Sampler for a variety of field realistic conditions. Collection effectiveness is defined as the ratio of the aerosol collected on the collection substrates of the sampler to that collected by an isokinetic sampling system.The collection effectiveness of the Standard EPA Hi-Volume Sampler was determined as a function of particle size (5–50 μm) and sampler orientation (0° and 45°) at a base condition wind speed of 4.6 m/s and 8% relative turbulence intensity. The results indicated a strong effect of orientation on collection effectiveness at a sampling rate of 1416 l/min. Wind speed over the range of 1.5–4.6 m/s does not greatly influence the collection effectiveness of 15 μm particles. Free stream turbulence levels of 1 and 8% relative intensity has no effect upon collection characteristics.The collection effectiveness of the Rocky Flats Hi-Volume Sampler was determined as a function of particle size (1–34 μm), wind speed (1.52–12.19 m/s) and sampler orientation to the mean flow (0°, 45°, 180°). The results show the sampler, with an inlet flow rate of 880 l/min, has an inlet effectiveness that was a slight function of orientation angle for particles 1–10 μm with a larger effect seen for 20–34 μm; a strong effect of velocity was seen up to 5 m/s where a further increase showed only a slight decrease in effectiveness.The Microsorban-98 filter that is presently used in the Rocky Flats Sampler was tested for efficiency over the size range of particles from 0.01–1 μm and with three different face velocities using the sampler flow rates of 600, 800 and 1 000 l/min corresponding to pressure drops of 20–24 in. of water (3.74–4.49 cm HaG). The filter paper, which was of the fiber type, was found to be 99.9% efficient over the range of particle sizes and pressure drops tested.  相似文献   

10.
The electrostatic granular filter developed by Combustion Power Company combines a moving-bed filter with an electrostatic grid for high-efficiency collection of particulate. The coulomb charge occurring naturally on particulate from combustion or other processes in which tribocharging occurs is sufficient such that imposition of an electric field substantially enhances mechanical collection in the packed filter. A mathematical model is presented which accounts for the major parameters affecting electrostatic performance. Experimental data developed in an industrial unit retrofitted with electrostatic equipment and a pilot-scale filter demonstrates dramatic improvement in opacity and outlet loading; the industrial unit achieved 99% collection efficiency with less that 4 Iwd (1kPa) pressure drop. Data from the pilot-scale filter has shown that collection of micron-size particulate is especially enhanced with the electric field and has confirmed the 99% overall collection capability demonstrated in the industrial unit. The design of a 420,000 acfm (1200 m3/min) system being installed at Weyerhaeuser Company's Longview, Washington plant is also discussed.  相似文献   

11.
Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented. The first two series were dilution experiments; examples of the results are given and discussed. The third series of tests was performed with one person working at a desk in the test room. Above the person;s head, a tracer gas (N2O) was injected into the convection plume, with as low momentum as possible. Starting with zero concentration, a test continued until steady-state conditions were established for the concentration levels in the different parts of the room. The tests included simulation of summer, autumn/spring, and winter daytime conditions. The results indicate a tendency towards lower tracer gas concentrations in the “breathing zone” when the supply air (typical flow rate equivalent to two air changes per hour) is brought into the room at a low level as compared to a high level close to the ceiling. The exhaust air terminal device in all tests was situated high in the “corridor” wall.  相似文献   

12.
The theory of competing risks cannot be based entirely on the analysis of postmortem pathology data. It is necessary also to know the prevalence and residence times of the diseases in question, separately and jointly, in the living population at risk. It is also necessary to have a conceptual model of the transition process from health to disease, or from one disease state to another, within the organism, so that the formal transition probabilities estimated from epidemiological data can be interpreted in biophysical terms as arising from changes in the physico-chemical state of the organism. This paper offers such a model for transition processes arising from fluctuations of physiological state (for example, lapse into diabetic coma or insulin shock as a result of extreme high or low excursions of the blood sugar level). A Gaussian fluctuation process is postulated, and the transition probability, or incidence rate, is calculated as the frequency with which the state variable fluctuates beyond a specified distance, Λ, from the mean state. An explicit solution is given for the limiting, but biologically reasonable, case that such an excursion is a rare event. In this case, the transition probability varies exponentially for linear displacement of Λ or of the dispersion of fluctuations, σ. If Λ decreases, and/or σ increases, as a linear function of age, this model yields an exponential (Gompertzian) relation of disease incidence to age. Generalization to more than one variable is accomplished by introducing the concept of a mortality potential surface, in which the disease transitions are geometrized as saddle points, or “passes”, on the surface.  相似文献   

13.
Glycine uptake by an isolated Pseudomonas species as a sole nitrogen source was studied in the presence of inorganic particulate. A pure culture of Pseudomonas species was grown in a continuous culture apparatus using a nitrogen-limited medium. The biomass from the chemostat was used in batch studies to evaluate the effects of alumnia or kaolinite on the glycine uptake rate. Stimulation and inhibition were dependent on the surface area of the particles added to the system. Stimulation occurred at low particle concentrations, while inhibition occurred at higher particle concentrations. Enhanced glycine uptake is attributed to an “adsorption” mechanism which may associate with the removal of toxic inhibitors from solution by adsorption onto the particle surface. Inhibition by these particles at high surface area densities may involve the removal of required compounds, as a factor of the particle surface area and not its size or type.  相似文献   

14.
船舶航行时螺旋桨产生的射流会对河道水流产生扰动,这种扰动是否能引起河床底泥的再悬浮需要更深入的论证分析。通过对比分析螺旋桨射流发展规律的研究成果,以湘江典型河段为研究对象,结合实船测量结果和此段河流地质资料,探讨了螺旋桨射流对湘江长株潭段河床底泥扰动的影响,并对此段河床底泥起动和悬浮条件进行了理论分析。结果表明:在周围环境流速较低的条件下,螺旋桨射流初始速度、河床水深及泥沙粒径是决定泥沙是否运动的主要因素。湘江长株潭河段已基本库区化,大部分河道平均水深远大于航道的标准水深2.8 m,河床泥沙平均粒径大于0.87 mm,其中细颗粒泥沙很少,由于螺旋桨射流断面平均流速小于泥沙起动流速,悬浮指标计算值远大于4,因此可以判断船舶正常航行在该段河流时底泥难以起动和再悬浮。  相似文献   

15.
In this paper, performance of a solar hybrid adsorption refrigeration (AR) system is investigated experimentally. Such a system was built and tested under the conditions at National Institute of Technology Calicut, Kerala, India. The hybrid system has been designed for heating 50 l of water from 25 to 90°C as well as cooling 10 l of water from 25 to 10°C. The experimental results demonstrate that the refrigerator has a cooling capacity of 47–78 W with a cycle coefficient of performance (COP) of 0.19 and maximum possible COP of 0.45. In exergy analysis of the system, the irreversibility and exergetic efficiency of each component of the system have been calculated. The exergy analysis reveals that the main source of irreversibility is the adsorbent bed of the AR system, emphasising that the input heat energy is not utilised efficiently due to material constraints. The exergetic efficiencies of condenser, expansion device, evaporator and adsorbent bed are found as 42.3%, 79.8%, 54.7% and 11%, respectively.  相似文献   

16.
The Electric Power Research Institute (EPRI) is currently supporting a major research program characterizing the performance of high efficiency electrostatic precipitators (ESP). One such effort evaluating the George Neal ESP of Iowa Public Service Company is described in this paper.Results show that under well tuned conditions the ESP overall collection efficiency was 99.7% at a specific collecting area of 745 ft2/kacfm (147 m2/m3/s) (520 MW) with associated mass concentrations of 0.025 lb/106 Btu and stack opacity of 4.6%. The boiler outlet size distribution was found to be bimodal with submicron and large particle peaks at 0.2 and 5 microns diameter, respectively. Consequently, an apparent bimodal fractional efficiency curve results with efficiencies of 99.6%, 98%, and 90% measured for 20, 2 and 0.2 micron diameter particles, respectively. Rapping reentrainment losses were found to be insignificant except during episodes of high ash hopper levels resulting from a malfunctioning ash removal system, when large rapping puffs were observed. In addition, outlet emissions increased dramatically to 0.08 lb/106 Btu (34 ng/J) during these periods, suggesting that an emission level more representative of daily operation lies somewhere between 0.025–0.08 lb/106 Btu (10.8–34 ng/J).  相似文献   

17.
18.
The very significant impact of European legislation (Directive 91/414/EEC) on the authorization of plant protection products is reviewed herein, which has resulted in withdrawal of 704 active substances (AS) out of 889 assessed so far. The list of currently approved 276 AS includes 194 AS “existing” in the market before 1993 and 82 “new” AS introduced during the last 15 years. Results of toxicity characterization of the approved AS are also summarized, utilizing several well-known databases. Although significant data gaps exist for a rather large part of the approved AS, it is found that 84 AS are positive for at least one health effect (after chronic and/or acute exposure) including carcinogenicity, reproductive and neuro-developmental disorders, as well as endocrine disruption. The toxicity characterization results of this study are compared to those of recent assessments by other organizations (KemI, the Swedish Chemicals Agency, and the Pesticide Safety Directorate of the UK), where interpretation and use is made of AS “cut-off” criteria foreseen in new EU legislation. These studies report a comparatively smaller AS number with positive toxicity characterization. The possibility of some additional AS withdrawal in the near future, combined with the rather small rate of new AS introduction (approx. 5 per year) suggest that the list of approved AS over the next 10–15 years may not change very drastically. Consideration of the above trends is necessary and instructive in evaluating results of existing health impact assessment (HIA) studies, as well as in planning new ones. Due to the very drastic change in the number and type of marketed AS, that took place within the past 8–9 years, it is suggested that new HIA studies (based on epidemiological data after year 2000) should focus on a rather short time frame and, therefore, on appropriate cohort groups, e.g. young children. For the same reason, results of epidemiological studies of the past (involving banned AS) should be carefully interpreted and used with caution.  相似文献   

19.
The automative diesel engine has long been acknowledged as being “dirtier” than the spark ignition engine and its particulate emissions may be carcinogenic. Possible solutions to the diesel emission problem are combustion modification or aftertreatment devices. Selection of candidate aftertreatment devices requires knowledge of the physical and chemical properties of the particles, including particle morphology, size distribution, mass concentration and emission rates in the exhaust gas stream. The study reported here represents the first of a series of experiments designed to characterize the exhaust emissions and test various aftertreatment devices. This paper deals only with the particulate characterization phase of the program. Results of size distribution, particle concentration and mass emission rate measurements for a 5.71 displacement Oldsmobile diesel engine are given for a variety of engine operating conditions.  相似文献   

20.
The opacity and emission performance of two “identical” cold-side precipitators at a power plant utilizing a Western coal source was investigated through an extensive test program. The test program included establishment of outlet emission versus opacity correlations for the two “identical” units, correlation of rapper strategy (frequency and amplitude) with opacity, and correlation of power-off rapping strategy with opacity. Analysis of the test program data demonstrates that the opacity-emission correlations from the two “identical” units can be significantly different. The potential reasons for the differences between the two units are identified and examined in light of the test program data. Strong correlation of opacity with rapping strategy was developed from the test program. Results demonstrate that an automatic power-off rapping technique can significantly enhance precipitator performance on ash from Western coal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号