《环境科学与技术》2010,(Z2)
研究间歇曝气/曝气生物滤池脱氮除磷效果,确定其最佳间歇时间,为该种形式的曝气生物滤池高效运行提供依据。试验采用序批式曝气生物滤池SBBR和传统曝气生物滤池BAF串联运行的方式,序批式曝气生物滤池(一级滤柱)曝气时间与停曝气时间比为2h/1h、3h/2h和4h/3h下运行。试验结果表明:曝气与停曝气间歇时间在3h/2h运行时,除磷效果好,TP去除率为86.9%,出水TP平均浓度为0.92mg/L,COD去除率为88.42%,出水平均浓度30mg/L,均达到《城镇污水处理厂污染物排放标准》一级标准。采用SBBR-BAF工艺能同时达到脱氮除磷的效果,且系统在间歇时间为3h/2h下运行时,处理污水效能最大。 相似文献
4.
5.
6.
《环境科学与技术》2010,(Z1)
研究间歇曝气/曝气生物滤池脱氮除磷效果,确定其最佳曝气量,为该种形式的曝气生物滤池高效运行提供依据。试验采用序批式曝气生物滤池和传统曝气生物滤池串联运行的方式,序批式曝气生物滤池(一级滤柱)在曝气量分别0.85L/(s·m2),1.27L/(s·m2),1.70L/(s·m2),2.12L/(s·m2)下运行,传统曝气生物滤池(二级滤柱)在曝气量分别为0.43L/(s·m2),0.85L/(s·m2),1.27L/(s·m2)下运行。试验结果表明:一级滤柱曝气量在1.70L/(s·m2)~2.12L/(s·m2)之间运行时,除磷效果好,出水TP含量在2.5mg/L以下,二级滤柱曝气量为0.85L/(s·m2)时,脱氮效果好,出水TN浓度为7.39mg/L,TN去除率达65.28%。采用间歇曝气/曝气生物滤池工艺能同时达到脱氮除磷的效果。 相似文献
7.
实验选用3个SBR反应器接种污水厂活性污泥,R1采用高表观气速(SGV)连续曝气,R2采用低SGV连续曝气,R3采用低SGV间歇曝气,在低碳氮比的实际生活污水中培养好氧颗粒污泥,探究不同SGV曝气条件对好氧颗粒污泥的形成及系统处理效果的影响.经过120d的培养,R1、R2和R3中颗粒粒径分别为(754±78),(812±86),(1183±93)μm,R3的脱氮除磷效果优于R1和R2.结果表明,应用低SGV间歇曝气策略在低碳氮比实际生活污水中培养的好氧颗粒污泥脱氮除磷性能良好,且系统中反硝化聚磷菌(DPAO)占聚磷菌(PAO)比例为24.75%. 相似文献
8.
对DAT-IAT工艺加以改良,在DAT池前端分隔出缺氧区和厌氧区,强化了系统脱氮除磷能力。并在不同运行条件下,对改良型DAT-IAT工艺的脱氮除磷效果进行研究,得出优化条件。结果表明:DAT池溶解氧浓度在1.82.2 mg/L之间;IAT池至DAT池的污泥回流比为300%;DAT池至缺氧区的混合液回流比为40%2.2 mg/L之间;IAT池至DAT池的污泥回流比为300%;DAT池至缺氧区的混合液回流比为40%50%;IAT池采用曝气1 h、沉淀1 h、排水1 h的运行工况;系统泥龄在1350%;IAT池采用曝气1 h、沉淀1 h、排水1 h的运行工况;系统泥龄在1316 d时,改良型工艺可以同时取得较好的脱氮和除磷效果,并且改良型工艺的脱氮除磷能力明显优于常规DAT-IAT工艺。 相似文献
9.
10.
报道了“中日湖泊水质富营养化控制研究项目”在贵州化肥厂建立的示范工程——使用两台脱氮除磷设备 ( BR型间歇曝气式脱氮除磷净化槽及 BS型序批式脱氮除磷净化槽 )对厂内生活区部分生活污水进行处理的情况。对该厂人均用水量大 ,水中有机物浓度、碳氮比均低的条件下 ,反应器内溶解氧控制对硝化反硝化反应的影响进行了初步研究 相似文献
11.
12.
间歇曝气对人工垂直潜流湿地氮磷去除性能的影响 总被引:7,自引:2,他引:7
采用页岩和香蒲(Typha latifolia)构建人工垂直潜流湿地处理津河富营养化水体,研究间歇曝气对潜流湿地氮磷去除效果的影响.设计水力负荷800 mm/d,气水比5∶1.试验期间(2006-06~2006-11),氮磷月平均去除率在8月份达到最大值.与无曝气系统相比,中部曝气使氨氮(NH 4-N)、总氮(TN)、可溶性活性磷(SRP)和总磷(TP)月平均去除率分别提高10.1%、4.7%、10.2%和8.8%,底部曝气则为25.1%、10.0%、7.7%和7.4%,间歇曝气能够有效提高人工潜流湿地氮磷去除效率.曝气产生的有氧环境不利于硝酸盐氮(NO-3-N)去除,试验期间底部曝气和中部曝气NO-3-N月平均去除率一直低于无曝气系统.试验结束后收割香蒲地上组织(茎和叶),测定地上组织生物量及茎、叶中的氮磷含量,结果表明,间歇曝气虽然抑制香蒲地上组织生物量的增加,但却能够有效提高茎、叶中氮磷含量.与无曝气系统相比,通过收割香蒲地上组织可使TN去除分别增加11.6g·m-2(中部曝气)和12.6 g·m-2(底部曝气). 相似文献
13.
为降低膜生物反应器(MBR)运行能耗和延缓膜污染,以厌氧折流板反应器(ABR)-MBR工艺处理生活污水为例,采用间歇曝气和添加颗粒填料两种方式对工艺脱氮除磷运行条件和膜污染问题进行研究.结果表明,增大间歇曝气时间有利于提高氮磷的去除效果,对COD、NH4+-N、TN和TP的平均去除率分别为91%、95%、84%和92%(工况4),而添加颗粒填料对氮磷的去除没有显著影响.双重好氧-缺氧交替环境强化了工艺对磷的去除.添加颗粒填料比间歇曝气更能有效延缓膜污染,同时改变了膜污染的形成过程,膜内部污染物含量显著增多,与泥饼层相比,多糖成为了膜污染的主要因素,不会对膜组件本身构成危害,增强了MBR反应器的实际应用性能. 相似文献
14.
A new airlift intermittent circulation integrated bioreactor was developed for simultaneous nitrogen and phosphorus removal of wastewater, in which, circulation of mixed liquid between mixing zone and aeration zone was realized by aeration power, alternately anaerobic/anoxic bio-environment in mixing zone was realized by intermittent circulation and simultaneous nitrogen and phosphorus removal was obtained through strengthened denitrifying phosphorus removal process. Removal performance of the reactor was investigated and pollutant removal and transfer mechanism in one operation circle was analyzed. The experiment results indicated that under the influent condition of chemical oxygen demand (COD) concentration of 642.1 mg/L, total nitrogen (TN) of 87.4 mg/L and PO43?-P of 12.1 mg/L, average removal efficiencies of COD, TN and PO43?-P reached 96.4%, 83.2% and 90.5%, respectively, with the hydraulic residence time of 22 hr and operation circle time of 185 min. Track studies indicated that the separation of aeration and mixing zones and intermittent circulation of mixed liquid between the two zones provided distinct biological environments spatially and temporally, which ensured the occurrence of multifunctional microbial reactions. 相似文献
15.
A new airlift intermittent circulation integrated bioreactor was developed for simultaneous nitrogen and phosphorus removal of wastewater, in which, circulation of mixed liquid between mixing zone and aeration zone was realized by aeration power, alternately anaerobic/anoxic bio-environment in mixing zone was realized by intermittent circulation and simultaneous nitrogen and phosphorus removal was obtained through strengthened denitrifying phosphorus removal process. Removal performance of the reactor was investigated and pollutant removal and transfer mechanism in one operation circle was analyzed. The experiment results indicated that under the influent condition of chemical oxygen demand (COD) concentration of 642.1 mg/L, total nitrogen (TN) of 87.4 mg/L and PO43--P of 12.1 mg/L, average removal efficiencies of COD, TN and PO43--P reached 96.4%, 83.2% and 90.5%, respectively, with the hydraulic residence time of 22 hr and operation circle time of 185 min. Track studies indicated that the separation of aeration and mixing zones and intermittent circulation of mixed liquid between the two zones provided distinct biological environments spatially and temporally, which ensured the occurrence of multifunctional microbial reactions. 相似文献
16.
氧化沟不同曝气模式对氮磷去除性能的优化与比较 总被引:1,自引:1,他引:1
采用轮流搅拌-曝气SBR系统模拟氧化沟的运行方式,探讨分点曝气和分段曝气对氮磷的去除效果.结果表明,在供气量相同的条件下,分点曝气系统溶氧效率高,一个循环的好氧区比分段曝气系统长,但是分段曝气溶解氧(DO)的有效利用率(用于除氮除磷)高,二者硝化能力相当,氨氮(NH4+-N)去除率分别为96.68%和97.03%,硝化菌活性(以NH4+-N/MLVSS计)分别为4.65和4.66 mg.(g.h)-1.在缺氧区和好氧区比例皆为1时,分点曝气在2、4、7个分区时总氮(TN)去除率分别为60.14%、47.93%和33.7%;总磷(TP)去除率分别为28.96%、23.75%和24.31%,即分区越少,对TN和TP的去除皆有利,但是更利于TN的去除;而分段曝气只有1个分区,其TN和TP的去除率分别为64.21%和49.09%,分段曝气对氮磷的去除效果优于分点曝气,但对提高TP的去除率更有利.对于分段曝气,在满足硝化效果的前提下,增大缺氧区与好氧区的比例,氮磷的去除效率增加.当缺氧区与好氧区的比例由1∶1增大至1.8∶1,其TN和TP的去除率分别提高到73.94%和54.18%.继续增加缺氧区的比例,将影响硝化和运行的稳定,从而影响氮磷的去除效果. 相似文献
17.
某城市污水厂运行中出现的问题及解决办法探讨 总被引:1,自引:1,他引:0
某城市污水处理厂采用改良氧化沟工艺处理生活污水,在运行中存在脱氮除磷效果不佳的问题。通过对该厂的工艺流程及进、出水水质情况等分析,结果表明:TN、TP去除率低的主要原因是进水有机物浓度与设计值相比偏低,氧化沟内很难形成设计时所设想的好氧/缺氧交替运行的环境以满足氮、磷的去除。因此,尽快完善污水收集系统,使城市污水处理厂进水水质达到设计要求是提高氮、磷去除效率的关键。在工艺中可适当减少曝气量来提高TN去除率,降低出水中的硝态氮和溶解氧,同时进一步提高TP去除率。 相似文献