首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A simple and sensitive spectrophotometric method for the determination of chromium has been developed. The method is based on the diazotization of Dapsone in hydroxylamine hydrochloride medium and coupling with N-(1-Napthyl) Ethylene Diamine Dihydrochloride by electrophilic substitution to produce an intense pink azo-dye, which has absorption maximum at 540 nm. The Beer's law is obeyed from 0.02-1.0 microg mL(-1) and the molar absorptivity is 3.4854 L mol(-1) cm(-1). The Limits of quantification and Limit of detection of the proposed method are 0.0012 microg mL(-1) and 0.0039 microg mL(-1) respectively. The method has been successfully applied for the determination of chromium in water samples and the results were statistically evaluated with that of the reference method.  相似文献   

3.
The value of pollination to human society is not limited to agricultural production, but also in the sustainability of ecosystems and the services that they provide. Seed set can be used as a comparative measure of pollination effectiveness, with minimum variability expected when other resources are not limiting. Six species of self-incompatible fall asters (Symphyotrichum) were used to evaluate pollination service at 12 sites across a spectrum of expected levels of pollination. Seed set per inflorescence was generally lower at sites with lower pollinator numbers and diversity, although as expected pollinator assemblage characteristics were highly variable within and between sites. However, rankings of sites showed consistency of response across phytometer species and between years; the summed ranks across multiple species appears to have as the greatest value in Pollination Service Measurement (PSM). Abundance, richness, and Shannon diversity of pollinator assemblages were highly autocorrelated and showed variable relationships with seed set depending on plant species and temporal scale of pollinator assemblage assessment. Use of seed set to directly measure pollination service at a site was consistent and cost effective when compared to less certain and more labour-intensive methods of pollinator collection and identification, and shows promise for implementation in pollination monitoring and bioassessment practices.  相似文献   

4.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

5.
6.
A major concern for the cork and wine industry is ‘cork taint’ which is associated with chloroanisoles, the microbial degradation metabolites of chlorophenols. The use of chlorophenolic compounds as pesticides within cork forests was prohibited in 1993 in the European Union (EU) following the introduction of industry guidance. However, cork produced outside the EU is still thought to be affected and simple, robust methods for chlorophenol analysis are required for wider environmental assessment by industry and local environmental regulators. Soil samples were collected from three common-use forests in Tunisia and from one privately owned forest in Sardinia, providing examples of varied management practice and degree of human intervention. These provided challenge samples for the optimisation of a HPLC-UV detection method. It produced recoveries consistently >75 % against a soil CRM (ERM-CC008) for pentachlorophenol. The optimised method, with ultraviolet (diode array) detection is able to separate and quantify 16 different chlorophenols at field concentrations greater than the limits of detection ranging from 6.5 to 191.3 μg/kg (dry weight). Application to a range of field samples demonstrated the absence of widespread contamination in forest soils at sites sampled in Sardinia and Tunisia.  相似文献   

7.
As selenium is an important part of the antioxidant enzymes and also because there are several studies suggesting a possible link between cancer and selenium deficiency, this paper presents a spectrophotometric method for the assay of Se(IV), using N,N-diethyl-p-phenylenediamine monohydrochloride as reagent. The proposed method is based on the reaction between the selenium and potassium iodide in low acidic medium, when iodine is released. This last product will further oxidise the new reagent. The final obtained product is strongly coloured in red and has an absorption maximum at 552 nm and molar extinction coefficient (ε) of 6.1?×?104 L mol?1 cm?1. The optimum working conditions were established, and the developed method was validated, being characterised by a good linearity (in the range of 0.5–3.0 μg/mL), a limit of detection (0.0573 μg/mL) and a limit of quantification (0.1737 μg/mL). At the same time, the repeatability, the precision of the method and the accuracy were established. The proposed and validated method was applied with good results for the determination of Se(IV) in spring and bottled water from Iasi and also in pharmaceutical and cosmetic products.  相似文献   

8.
Two hydride generation manifold systems, utilizing flow injection and cryotrapping techniques for alkyl-metal(loid) speciation analysis in natural waters, are described in this paper. They provide shipboard capacity for simultaneous derivatization of analytes with NaBH4 and cryotrapping of the generated products in a field packed column at -196 degrees C. The first system is a large-volume hydride generator, using a reagent-injection flow technique as a flow batch type, that has been fully optimized and applied to the simultaneous detection of alkylated species in estuarine waters. The technique permits the analysis of a large volume sample (0.5-11) at a sampling rate of 3 h-1. The second is an online continuous flow hydride generator. A sampling rate of 3-12 h-1 can be achieved with samples of 0.1-0.51. In addition, shipboard operation eliminates major problems related to sample pretreatment, transport and storage. Ultra-trace multi-element determination is finally performed in the laboratory by cryogenic GC hyphenated with ICP-MS. Routine detection limits of 0.5-10 pg (as metal) for 0.51 water samples were achieved for the selected alkyl-metal(loid) species of arsenic, germanium, mercury and tin. Concentrations of various species, obtained from water samples taken from the Rhine estuary, are also presented. These species include alkylated arsenic compounds, other than methyl derivatives, that have been tentatively identified and are reported here for the first time.  相似文献   

9.
介绍了一种用于TEA挂片测定NO2的滤膜制备方法,解决了原方法中存在的滤膜空白值偏高且不稳定的问题.实验结果表明,该方法可用于大面积、多点位同步监侧中大批量滤膜的制备.  相似文献   

10.
Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, alpha-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 microg m(-3)), they are all below 0.5 microg m(-3). Calibration curves are linear up to 10 micromol m(-3) for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.  相似文献   

11.
Bulking of activated sludge is a world-widely prevalent problem and can lead to loss of bio-oxidation, further deterioration of effluent quality, and even to a complete breakdown of the entire treatment process. Most common reasons of bulking are bacterial community changes, especially excessive growth of filamentous bacteria or excess of biopolymers on surface of non-filamentous microbes. Because of complex nature of the bulking phenomenon, the successful bulking control strategy finding is still a very important need awaiting new options and advices. The repetitive extragenic palindromic PCR (REP-PCR) fingerprinting method has been applied to distinguish bacterial community in non-bulking and bulking activated sludge. The characteristic REP-PCR fingerprinting patterns, using the Ward??s clustering method, have been analyzed to determine homology/similarity relation between particular non-bulking and bulking sludge sampling. The received clustering results were in high concordance with activated sludge typing done based on physicochemical sludge analysis. The choice and application of molecular typing method in sludge analysis will depend upon the needs, skill level, and resources of the laboratory. The proposed REP-PCR method and statistical analysis of fingerprinting patterns seems to be simple, rapid, and effective methods to show differences between population in non-bulking and bulking activated sludge. It is easy to implement, and it may be useful for routinely activated sludge monitoring as well as may be helpful in early detection of bulking process.  相似文献   

12.
Trichloroacetic acid (TCAA) is a phytotoxic chemical, present throughout the environment. The majority of methods for analysis of TCAA require chemical derivatisation and multiple extraction steps prior to analysis by gas-chromatography. Here, a new analytical method for TCAA determination in environmental matrices is reported. The method is based on a modified Nielsen-Kryger steam distillation that combines into one 1 h reflux the thermal decarboxylation of TCAA to CHCl3 and the partitioning and concentration of the CHCl3 into 5 ml of hexane, which is analysed by GC. Sample preparation is minimal and no matrix standard additions are required. The background CHCl3 in the sample is removed prior to extraction by degassing the solution for 1 h with nitrogen. Optimisation of the method gave recoveries from three separate solutions of 0.31 ppb aqueous TCAA standards of 93 +/- 15% (n = 9), 110 +/- 9% (n = 9) and 105 +/- 11% (n = 6). The extraction method has been compared with a decarboxylation and headspace GC method for determination of TCAA in Sitka spruce needles. No significant difference in TCAA concentration or replicate precision between the two methods was observed.  相似文献   

13.
N-Ethyl-3-cabazolecarboxaldehydethiosemicarbazone (ECCT) is proposed as a new, sensitive and selective complexing reagent for the separation and extractive spectrophotometric determination of palladium(II) at pH: 4.0 to form a yellowish orange colored 1:1 chelate complex, which is very well extracted in to n-butanol. The absorbance was measured at a maximum wavelength, 410 nm. This method obeys Beer’s law in the concentration range 0.0–6.6 μg mL−1 and the correlation coefficient of Pd(II)-ECCT complex is 0.998, which indicates an excellent linearity between the two variables with good molar absorptivity and Sandell’s sensitivity, 1.647 × 104 l mol−1cm−1, 6.49 × 10−3 μg cm−2, respectively. The instability constant of complex calculated from Edmond’s method, 2.724 × 10−5 was in good agreement with the value calculated from Asmus’ method 2.624 × 10−5, at room temperature. The precision and accuracy of the method is checked with calculation of relative standard deviation (n = 5), 0.839. Edmond’s method was observed to be a more selective method in the presence of EDTA, oxalate and phosphate ions. The method was successfully applied for the determination of Pd(II) in water samples, synthetic mixtures and hydrogenation catalysts, employing an atomic absorption spectrometer for comparing these results.  相似文献   

14.
Variable availability of the purified dihydrochloride salt of 3,3'-dimethoxybenzidine (DMB; ortho-dianisidine) led us to investigate the effects of reagent purity on the analytical results obtained when this reagent is used in the photometric determination of the disinfection byproduct bromate. After analyte ions are separated by ion chromatography, a solution of DMB (post-column reagent) is added to the eluate and the DMB is oxidized, thereby producing a chromophore detected by its absorbance. Although some commercial products of undefined grade performed well, others did not. Variability was also observed between lots of purified material. Sensitivity at low concentrations (< 5 micrograms L-1 BrO3-) varied by a factor of up to 10. In some cases, the lower limit of detection for photometric detection was greater than that obtained using conductivity detection, as high as 5-7 micrograms L-1 BrO3-. An impurity or several impurities are suspected to be responsible for deviations from linearity at low analyte concentrations. This investigation underscores the need for ensuring reagent purity in environmental analyses. Ideally, chemical manufacturers will meet the needs of analytical chemists who test potable water and begin producing a high grade material in sufficient quantities to meet monitoring requirements. The establishment of third-party standards for a spectrophotometric grade of DMB.2HCl would be helpful in ensuring that a variety of manufacturers could supply products of uniformly high quality that would be suitable for the measurement of bromate in public drinking water supplies.  相似文献   

15.
稀释倍数法的误差分析和色度检测仪的开发   总被引:1,自引:1,他引:1  
稀释倍数法是目前废水色度检测中常用的方法,文章对该方法存在的误差进行了分析,并设计了一种新型色度检测仪,可以大大降低色度测定的误差,同时简化了操作过程。  相似文献   

16.
17.
The analytical techniques used for the determination of butyltin compounds in biological tissues are generally based on a succession of steps (e.g., extraction, derivatization, separation, detection) which are all prone to systematic errors. An interlaboratory programme performed at the EU level and based on a stepwise approach has enabled one to identify and remove most of these errors and to improve considerably the state of the art so that certification of a mussel reference material has been made possible. This paper describes the preparation of this mussel reference material containing monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT), the homogeneity and stability studies and the analytical work performed for the certification of the contents of MBT [Sn(C4H9)3+], DBT [Sn(C4H9)2(2+)] and TBT [Sn(C4H9)3+]. The results obtained by a group of expert EU laboratories are discussed along with the methods used to certify the mass fractions (based on dry mass) of monobutyltin (1.50 +/- 0.28 mg kg-1 as MBT cations), dibutyltin (1.54 +/- 0.12 mg kg-1 as DBT cations) and tributyltin (2.20 +/- 0.19 mg kg-1 as TBT cations). The paper also describes an attempt to certify the content of triphenyltin in this material which, although reasonable agreement was found among the participants' results, failed owing to the instability of this compound. This new material will be of great support to ensure the quality control of butyltin determination in shellfish, as carried out in environmental monitoring programmes.  相似文献   

18.
A new HPLC method was developed for the simultaneous determination of aminophenol isomers by means of a mixed-mode stationary phase containing both SCX and C18 moieties. All factors influencing the separation were discussed and optimized. The chromatographic conditions for the separation of aminophenols are the stationary phase duet SCX/C18, the mobile phase of aqueous phosphate buffer (pH 4.85):methanol?=?85:15 (v/v) delivered with a flow rate of 1 mL/min and a detection at 285 nm. The method proposed was validated in terms of linearity, limits of detection and quantification, accuracy and precision. The HPLC method elaborated here was applied with good results on river water samples. In order to survey the quality of surface rivers entered in treatment plants which deliver water for Bucharest, two major rivers were included in a monitoring program which last more than 1 year.  相似文献   

19.
Given the increasing interest in using peat bogs as archives of atmospheric metal deposition, the lack of validated sample preparation methods and suitable certified reference materials has hindered not only the quality assurance of the generated analytical data but also the interpretation and comparison of peat core metal profiles from different laboratories in the international community. Reference materials play an important role in the evaluation of the accuracy of analytical results and are essential parts of good laboratory practice. An ombrotrophic peat bog reference material has been developed by 14 laboratories from nine countries in an inter-laboratory comparison between February and October 2002. The material has been characterised for both acid-extractable and total concentrations of a range of elements, including Al, As, Ca, Cd, Cr, Cu, Fe, Hg, Mg, Mn, Na, Ni, P, Pb, Ti, V and Zn. The steps involved in the production of the reference material (i.e. collection and preparation, homogeneity and stability studies, and certification) are described in detail.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号