首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
At many "real world" field sites, the number of available monitoring wells is limited due to economic or geological reasons. Under such restricted conditions, it is difficult to perform a reliable field investigation and to quantify primary lines of evidence for natural attenuation (NA), like the documentation of a decrease of contaminant mass flux in flow direction. This study reports the results of a groundwater investigation at a former manufactured gas plant situated in a Quaternary river valley in southwest Germany. The location, infrastructure and aquifer setting are typical of many industrial sites in Germany. Due to difficult drilling conditions (coarse glaciofluvial gravel deposits and an anthropogenic fill above the aquifer), only 12 monitoring wells were available for the investigation and localisation of the contaminant plume. These wells were situated along three control planes (CP) downgradient from the contaminant source, with four wells along each plane. Based on the sparse set of monitoring wells, field scale mass fluxes and first-order natural attenuation rate constants of benzene, toluene, ethylbenzene, and o-xylene and p-xylene (BTEX) and low molecular weight polycyclic aromatic hydrocarbons (PAH) were estimated utilizing different point scale and also a new integral investigation method. The results show that even at a heterogeneous site with a sparse monitoring network point scale investigation methods can provide reliable information on field scale natural attenuation rates, if a dependable flow model or tracer test data is available. If this information is not available, only the new integral investigation method presented can yield adequate results for the quantification of contaminant mass fluxes under sparse monitoring conditions.  相似文献   

2.
Changes in contaminant fluxes resulting from aggressive remediation of dense nonaqueous phase liquid (DNAPL) source zone were investigated at two sites, one at Hill Air Force Base (AFB), Utah, and the other at Ft. Lewis Military Reservation, Washington. Passive Flux Meters (PFM) and a variation of the Integral Pumping Test (IPT) were used to measure fluxes in ten wells installed along a transect down-gradient of the trichloroethylene (TCE) source zone, and perpendicular to the mean groundwater flow direction. At both sites, groundwater and contaminant fluxes were measured before and after the source-zone treatment. The measured contaminant fluxes (J; ML(-2)T(-1)) were integrated across the well transect to estimate contaminant mass discharge (M(D); MT(-1)) from the source zone. Estimated M(D) before source treatment, based on both PFM and IPT methods, were approximately 76 g/day for TCE at the Hill AFB site; and approximately 640 g/day for TCE, and approximately 206 g/day for cis-dichloroethylene (DCE) at the Ft. Lewis site. TCE flux measurements made 1 year after source treatment at the Hill AFB site decreased to approximately 5 g/day. On the other hand, increased fluxes of DCE, a degradation byproduct of TCE, in tests subsequent to remediation at the Hill AFB site suggest enhanced microbial degradation after surfactant flooding. At the Ft. Lewis site, TCE mass discharge rates subsequent to remediation decreased to approximately 3 g/day for TCE and approximately 3 g/day for DCE approximately 1.8 years after remediation. At both field sites, PFM and IPT approaches provided comparable results for contaminant mass discharge rates, and show significant reductions (>90%) in TCE mass discharge as a result of DNAPL mass depletion from the source zone.  相似文献   

3.
In recent years, natural attenuation (NA) has evolved into a possible remediation alternative, especially in the case of BTEX spills. In order to be approved by the regulators, biodegradation needs to be demonstrated which requires efficient site investigation and monitoring tools. Three methods--the Integral Groundwater Investigation method, the compound-specific isotope analysis (CSIA) and a newly developed combination of both--were used in this work to quantify at field scale the biodegradation of o-xylene at a former gasworks site which is heavily contaminated with BTEX and PAHs. First, the Integral Groundwater Investigation method [Schwarz, R., Ptak, T., Holder, T., Teutsch, G., 1998. Groundwater risk assessment at contaminated sites: a new investigation approach. In: Herbert, M. and Kovar, K. (Editors), GQ'98 Groundwater Quality: Remediation and Protection. IAHS Publication 250, pp. 68-71; COH 4 (2000) 170] was applied, which allows the determination of mass flow rates of o-xylene by integral pumping tests. Concentration time series obtained during pumping at two wells were used to calculate inversely contaminant mass flow rates at the two control planes that are defined by the diameter of the maximum isochrone. A reactive transport model was used within a Monte Carlo approach to identify biodegradation as the dominant process for reduction in the contaminant mass flow rate between the two consecutive control planes. Secondly, compound-specific carbon isotope analyses of o-xylene were performed on the basis of point-scale samples from the same two wells. The Rayleigh equation was used to quantify the degree of biodegradation that occurred between the wells. Thirdly, a combination of the Integral Groundwater Investigation method and the compound-specific isotope analysis was developed and applied. It comprises isotope measurements during the integral pumping tests and the evaluation of delta13C time series by an inversion algorithm to obtain spatially integrated mean isotope values at the control planes. It was shown that the Rayleigh equation is applicable to spatially integrated mean isotope values in order to obtain the mean biodegradation between the consecutive control planes. All three approaches yielded consistently a 98-99% degradation of o-xylene.  相似文献   

4.
Groundwater and contaminant fluxes were measured, using the passive flux meter (PFM) technique, in wells along a longitudinal transect passing approximately through the centerline of a trichloroethylene (TCE) plume at a former manufacturing plant located in the Midwestern US. Two distinct zones of hydraulic conductivity were identified from the measured groundwater fluxes; a 6-m-thick upper zone ( approximately 7 m to 13 m below the ground surface or bgs) with a geometric mean Darcy flux (q(0)) of 2 cm/day, and a lower zone ( approximately 13 m to 16.5m bgs) with a q(0) approximately 15 cm/day; this important hydrogeologic feature significantly impacts any remediation technology used at the site. The flux-averaged TCE concentrations estimated from the PFM results compared well with existing groundwater monitoring data. It was estimated that at least 800 kg of TCE was present in the source zone. The TCE mass discharge across the source control plane (85 m x 38 m) was used to estimate the "source strength" ( approximately 365 g/day), while mass discharges across multiple down-gradient control planes were used to estimate the plume-averaged, TCE degradation rate constant (0.52 year(-1)). This is close to the rate estimated using the conventional centerline approach (0.78 year(-1)). The mass discharge approach provides a more robust and representative estimate than the centerline approach since the latter uses only data from wells along the plume centerline while the former uses all wells in the plume.  相似文献   

5.
The contaminant mass discharge crossing a control plane is an important metric in the assessment of natural attenuation at contaminated sites. For risk-assessment purposes, the mass discharge must be estimated together with a level of uncertainty. We present a conditional Monte Carlo approach that allows estimating the statistical distribution of mass discharge. The approach is based on conditioning multiple realizations of the hydraulic conductivity field on all data available. We jointly determine a first-order decay coefficient in each realization, leading to conditional statistical distributions of all estimated parameters and the total mass discharge. The resulting statistical distribution of contaminant mass discharges can be used in the assessment of risks at the contaminated site. The method is applied to data of hypothetical test cases, which gives the opportunity to compare estimation results to the true field. As concentration data, we account for pointlike measurements obtained in multi-level sampling wells. The obtained empirical distribution of mass discharge crossing the multi-level sampling fence could be well fitted by a log-normal distribution.  相似文献   

6.
When considering natural attenuation as a remediation strategy at a site contaminated by a light non-aqueous phase liquid (LNAPL), it is important to consider the emission of contaminants from the source zone. A quantification of source-zone emissions is essential both for comparison with down-gradient mass fluxes to provide an estimate of fractional mass flux reduction, as well as for estimating the source lifetime. Because the spatial distribution of LNAPL at a field site is strongly dependent on both the spill circumstances and the heterogeneity of the geologic materials, which can be problematic for in-situ determination, alternative methods for estimating source-zone emissions are needed. In this work, a three-dimensional multiphase flow and transport modelling approach is used to investigate the relationship between the lateral extent of an LNAPL body and the emission of contaminants to groundwater at a contaminated site. For simulations involving an LNAPL release in an aquifer comprised of heterogeneous porosity and permeability distributions that were generated geostatistically, it is shown that a simple linear relationship exists between the lateral extent of the LNAPL body in the capillary fringe and the emission to the aqueous phase. The parameters describing the relationship are found to be linear functions of the groundwater flow velocity and the vertical infiltration rate. This site-specific relationship provides a simple method to estimate contaminant emissions to groundwater at LNAPL contaminated sites.  相似文献   

7.
This paper introduces a new direct method for measuring water and contaminant fluxes in porous media. The method uses a passive flux meter (PFM), which is essentially a self-contained permeable unit properly sized to fit tightly in a screened well or boring. The meter is designed to accommodate a mixed medium of hydrophobic and/or hydrophilic permeable sorbents, which retain dissolved organic/inorganic contaminants present in the groundwater flowing passively through the meter. The contaminant mass intercepted and retained on the sorbent is used to quantify cumulative contaminant mass flux. The sorptive matrix is also impregnated with known amounts of one or more water soluble 'resident tracers'. These tracers are displaced from the sorbent at rates proportional to the groundwater flux; hence, in the current meter design, the resident tracers are used to quantify cumulative groundwater flux. Theory is presented and quantitative tools are developed to interpret the water flux from tracers possessing linear and nonlinear elution profiles. The same theory is extended to derive functional relationships useful for quantifying cumulative contaminant mass flux. To validate theory and demonstrate the passive flux meter, results of multiple box-aquifer experiments are presented and discussed. From these experiments, it is seen that accurate water flux measurements are obtained when the tracer used in calculations resides in the meter at levels representing 20 to 70 percent of the initial condition. 2,4-Dimethyl-3-pentanol (DMP) is used as a surrogate groundwater contaminant in the box aquifer experiments. Cumulative DMP fluxes are measured within 5% of known fluxes. The accuracy of these estimates generally increases with the total volume of water intercepted.  相似文献   

8.
In this paper, the integral groundwater investigation method is used for the quantification of PCE and TCE mass flow rates at an industrialized urban area in Linz, Austria. In this approach, pumping wells positioned along control planes perpendicular to the groundwater flow direction are operated for a time period on the order of days and sampled for contaminants. The concentration time series of the contaminants measured during operation of the pumping wells are then used to determine contaminant mass flow rates, mean concentrations and the plume shapes and positions at the control planes. The three control planes used in Linz were positioned downstream of a number of potential source zones, which are distributed over the field site. By use of the integral investigation method, it was possible to identify active contaminant sources, quantify the individual source strength in terms of mass flow rates at the control planes and estimate the contaminant plume position relative to the control planes. The source zones emitting the highest PCE and TCE mass flow rates could be determined, representing the areas where additional investigation and remediation activities will be needed. Additionally, large parts of the area investigated could be excluded from further investigation and remediation activities.  相似文献   

9.
This study comprises the first application of the Passive Flux Meter (PFM) for the measurement of chlorinated aliphatic hydrocarbon (CAH) mass fluxes and Darcy water fluxes in groundwater at a European field site. The PFM was originally developed and applied to measurements near source zones. The focus of the PFM is extended from near source to plume zones. For this purpose, 48 PFMs of 1.4 m length were constructed and installed in eight different monitoring wells in the source and plume zone of a CAH-contaminated field site located in France. The PFMs were retrieved, sampled, and analyzed after 3 to 11 weeks of exposure time, depending on the expected contaminant flux. PFM evaluation criteria include analytical, technical, and practical aspects as well as conditions and applicability. PFM flux data were compared with so-called traditional soil and groundwater concentration data obtained using active sampling methods. The PFMs deliver reasonable results for source as well as plume zones. The limiting factor in the PFM applicability is the exposure time together with the groundwater flux. Measured groundwater velocities at the field site range from 2 to 41 cm/day. Measured contaminant flux data raise up to 13 g/m2/day for perchloroethylene in the plume zone. Calculated PFM flux averaged concentration data and traditional concentration data were of similar magnitude for most wells. However, both datasets need to be compared with reservation because of the different sampling nature and time. Two important issues are the PFM tracer loss during installation/extraction and the deviation of the groundwater flow field when passing the monitoring well and PFM. The demonstration of the PFM at a CAH-contaminated field site in Europe confirmed the efficiency of the flux measurement technique for source as well as plume zones. The PFM can be applied without concerns in monitoring wells with European standards. The acquired flux data are of great value for the purpose of site characterization and mass discharge modeling, and can be used in combination with traditional soil and groundwater sampling methods.  相似文献   

10.
Monitoring of contaminant concentrations, e.g., for the estimation of mass discharge or contaminant degradation rates, often is based on point measurements at observation wells. In addition to the problem, that point measurements may not be spatially representative, a further complication may arise due to the temporal dynamics of groundwater flow, which may cause a concentration measurement to be not temporally representative. This paper presents results from a numerical modeling study focusing on temporal variations of the groundwater flow direction. “Measurements” are obtained from point information representing observation wells installed along control planes using different well frequencies and configurations. Results of the scenario simulations show that temporally variable flow conditions can lead to significant temporal fluctuations of the concentration and thus are a substantial source of uncertainty for point measurements. Temporal variation of point concentration measurements may be as high as the average concentration determined, especially near the plume fringe, even when assuming a homogeneous distribution of the hydraulic conductivity. If a heterogeneous hydraulic conductivity field is present, the concentration variability due to a fluctuating groundwater flow direction varies significantly within the control plane and between the different realizations. Determination of contaminant mass fluxes is also influenced by the temporal variability of the concentration measurement, especially for large spacings of the observation wells. Passive dosimeter sampling is found to be appropriate for evaluating the stationarity of contaminant plumes as well as for estimating average concentrations over time when the plume has fully developed. Representative sampling has to be performed over several periods of groundwater flow fluctuation. For the determination of mass fluxes at heterogeneous sites, however, local fluxes, which may vary considerably along a control plane, have to be accounted for. Here, dosimeter sampling in combination with time integrated local water flux measurements can improve mass flux estimates under dynamic flow conditions.  相似文献   

11.
Measuring contaminant flow rates at control cross sections is the most accurate method to evaluate natural attenuation processes in the saturated subsurface. In most instances, point scale measurement is the method of choice due to practical reasons and cost factors. However, at many field sites, the monitoring network is too sparse for a reliable estimation of contaminant and groundwater flow rates. Therefore, integral pumping tests have been developed as an alternative. In this study, we compare mass flow rates obtained by integral pumping test results and point scale data. We compare results of both methods with regard to uncertainties due to estimation errors and mass flow estimations based on two different point scale networks. The differences between benzene and groundwater flow rate estimates resulting from point scale samples and integral pumping tests were 6.44% and 6.97%, respectively, demonstrating the applicability of both methods at the site. Point scale-based data, especially with use of cost efficient Direct-Push technique, can be applied to show the contaminant distribution at a site and may be followed by a denser point scale network or an integral method. Nevertheless, a combination of both methods decreases uncertainties.  相似文献   

12.
A quantitative methodology is described for the field-scale performance assessment of natural attenuation using plume-scale electron and carbon balances. This provides a practical framework for the calculation of global mass balances for contaminant plumes, using mass inputs from the plume source, background groundwater and plume residuals in a simplified box model. Biodegradation processes and reactions included in the analysis are identified from electron acceptors, electron donors and degradation products present in these inputs. Parameter values used in the model are obtained from data acquired during typical site investigation and groundwater monitoring studies for natural attenuation schemes. The approach is evaluated for a UK Permo-Triassic Sandstone aquifer contaminated with a plume of phenolic compounds. Uncertainty in the model predictions and sensitivity to parameter values was assessed by probabilistic modelling using Monte Carlo methods. Sensitivity analyses were compared for different input parameter probability distributions and a base case using fixed parameter values, using an identical conceptual model and data set. Results show that consumption of oxidants by biodegradation is approximately balanced by the production of CH4 and total dissolved inorganic carbon (TDIC) which is conserved in the plume. Under this condition, either the plume electron or carbon balance can be used to determine contaminant mass loss, which is equivalent to only 4% of the estimated source term. This corresponds to a first order, plume-averaged, half-life of > 800 years. The electron balance is particularly sensitive to uncertainty in the source term and dispersive inputs. Reliable historical information on contaminant spillages and detailed site investigation are necessary to accurately characterise the source term. The dispersive influx is sensitive to variability in the plume mixing zone width. Consumption of aqueous oxidants greatly exceeds that of mineral oxidants in the plume, but electron acceptor supply is insufficient to meet the electron donor demand and the plume will grow. The aquifer potential for degradation of these contaminants is limited by high contaminant concentrations and the supply of bioavailable electron acceptors. Natural attenuation will increase only after increased transport and dilution.  相似文献   

13.
When only few monitoring wells are available to assess the extent and level of groundwater contamination, inversion of concentration breakthrough curves acquired during an integral pumping test can be used as an alternative quantification method. The idea is to use concentration-time series recorded during integral pumping tests through an inversion technique to estimate contaminant mass fluxes crossing a control plane. In this paper, we examine how a longitudinal concentration gradient along a contaminant plume length scale affects the estimated inversed-concentration distribution and its associated mass flux. The analytically inversed-concentration distribution at the imaginary control plane (ICP) is compared to a numerically generated concentration distribution, treating the latter one as a "real contaminant plume" characterized by the presence of a longitudinal concentration gradient. It is found that the analytically inversed-concentration can lead to overestimation or underestimation of concentration distribution values depending on the transport time period and dispersivity values. At lower dispersivity values, with shorter transport time periods, the analytically inversed-concentration distribution overestimates the "real" concentration distribution. A better fit of the estimated concentration distribution to the "real" one is observed when the transport time period increases, i.e. when the advective front has already crossed the ICP. However, for higher dispersivity values, underestimation of the real concentration distribution is observed. Deviation of the inversed-concentration distribution from the "real" one is assessed for a site-specific concentration gradient term. A concentration gradient adjusted contaminant mass flux is thus formulated to evaluate groundwater contamination levels at a given time period through an ICP. This concentration gradient ratio can indicate whether the ICP is well positioned to evaluate accurately contaminant mass fluxes which are representative of groundwater contamination levels.  相似文献   

14.
When only few monitoring wells are available to assess the extent and level of groundwater contamination, inversion of concentration breakthrough curves acquired during an integral pumping test can be used as an alternative quantification method. The idea is to use concentration–time series recorded during integral pumping tests through an inversion technique to estimate contaminant mass fluxes crossing a control plane. In this paper, we examine how a longitudinal concentration gradient along a contaminant plume length scale affects the estimated inversed-concentration distribution and its associated mass flux. The analytically inversed-concentration distribution at the imaginary control plane (ICP) is compared to a numerically generated concentration distribution, treating the latter one as a “real contaminant plume” characterized by the presence of a longitudinal concentration gradient. It is found that the analytically inversed-concentration can lead to overestimation or underestimation of concentration distribution values depending on the transport time period and dispersivity values. At lower dispersivity values, with shorter transport time periods, the analytically inversed-concentration distribution overestimates the “real” concentration distribution.A better fit of the estimated concentration distribution to the “real” one is observed when the transport time period increases, i.e. when the advective front has already crossed the ICP. However, for higher dispersivity values, underestimation of the real concentration distribution is observed. Deviation of the inversed-concentration distribution from the “real” one is assessed for a site-specific concentration gradient term. A concentration gradient adjusted contaminant mass flux is thus formulated to evaluate groundwater contamination levels at a given time period through an ICP. This concentration gradient ratio can indicate whether the ICP is well positioned to evaluate accurately contaminant mass fluxes which are representative of groundwater contamination levels.  相似文献   

15.
This study focused on evaluating and quantifying the potential of natural attenuation of groundwater at a petroleum-contaminated site in an industrial area of a satellite city of Seoul, Korea. Groundwater at the study site was contaminated with toluene, ethylbenzene and xylene (TEX). Eight rounds of groundwater sampling and subsequent chemical analyses were performed over a period of 3 years. The groundwater quality data suggests that TEX concentrations at this site have been decreasing with time and that the TEX plume is at a quasi-steady state. Trend analysis, changes in mass flux and plume area also confirmed that the TEX plume has reached a quasi-steady state. The proportion of the total attenuation attributable to biodegredation has decreased over the monitoring period while contribution of other attenuating processes, such as dilution or dispersion, has increased. Based on the calculated attenuation rates, it would take more than 20 years to clean up the site by natural attenuation alone.  相似文献   

16.
A multi-dimensional and multi-species reactive transport model was developed to aid in the analysis of natural attenuation design at chlorinated solvent sites. The model can simulate several simultaneously occurring attenuation processes including aerobic and anaerobic biological degradation processes. The developed model was applied to analyze field-scale transport and biodegradation processes occurring at the Area-6 site in Dover Air Force Base, Delaware. The model was calibrated to field data collected at this site. The calibrated model reproduced the general groundwater flow patterns, and also, it successfully recreated the observed distribution of tetrachloroethene (PCE), trichloroethene (TCE), dichloroethylene (DCE), vinyl chloride (VC) and chloride plumes. Field-scale decay rates of these contaminant plumes were also estimated. The decay rates are within the range of values that were previously estimated based on lab-scale microcosm and field-scale transect analyses. Model simulation results indicated that the anaerobic degradation rate of TCE, source loading rate, and groundwater transport rate are the important model parameters. Sensitivity analysis of the model indicated that the shape and extent of the predicted TCE plume is most sensitive to transmissivity values. The total mass of the predicted TCE plume is most sensitive to TCE anaerobic degradation rates. The numerical model developed in this study is a useful engineering tool for integrating field-scale natural attenuation data within a rational modeling framework. The model results can be used for quantifying the relative importance of various simultaneously occurring natural attenuation processes.  相似文献   

17.
The transfer of contaminant mass between the nonaqueous- and aqueous-phases is a process of central importance for the remediation of sites contaminated by dense nonaqueous-phase liquids (DNAPLs). This paper describes a comparison of the results obtained with various alternative DNAPL-aqueous-phase mass transfer models contained in the literature for predicting DNAPL source-zone depletion times in groundwater systems. These dissolution models were largely developed through laboratory column experiments. To gain insight into the implications of various representations of the local-scale kinetic as well as equilibrium DNAPL dissolution processes, aquifer heterogeneity and the complex architecture of a DNAPL source-zone, the aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are analyzed in a conditional stochastic framework. The hydrogeologic setting is a heterogeneous fluvial aquifer in Southwest Germany, referred to as the aquifer analog dataset, that was intensively characterized in three dimensions for hydrogeological parameters that include permeability, effective porosity, grain size, mineralogy and sorption coefficients. By embedding the various dissolution models into the compositional, multiphase flow model, CompFlow, the relative times predicted for complete depletion of a released DNAPL source due to natural dissolution are explored. Issues related to achieving environmental benefits through, for example, partial DNAPL-zone source removal via enhanced remedial technologies are also discussed. In this context, performance metrics in the form of peak aqueous-phase contaminant concentrations and mass fluxes arriving at a down-gradient compliance boundary are compared to each other. This is done for each of the alternative mass transfer models. A significant reduction in the fractional flux at a downstream location from the DNAPL source can be achieved by partial source-zone mass reduction; however, peak concentration levels at the same location remain much higher than the United States Environment Protection Agency (US-EPA) drinking water limits. Although groundwater quality was found to improve more rapidly for the equilibrium dissolution model, it is also shown that dissolution models that promote rapid DNAPL disappearance produce greater prediction uncertainty in the aqueous-phase flux reduction.  相似文献   

18.
Processes controlling the distribution and natural attenuation (NA) of phenol, cresols and xylenols released from a former coal-tar distillation plant in a deep Triassic sandstone aquifer are evaluated from vertical profiles along the plume centerline at 130 and 350 m from the site. Up to four groups of contaminants (phenols, mineral acids, NaOH, NaCl) form discrete and overlapping plumes in the aquifer. Their distribution reflects changing source history with releases of contaminants from different locations. Organic contaminant distribution in the aquifer is determined more by site source history than degradation. Contaminant degradation at total organic carbon (TOC) concentrations up to 6500 mg l(-1) (7500 mg l(-1) total phenolics) is occurring by aerobic respiration NO3-reduction, Mn(IV)-/Fe(III)-reduction, SO4-reduction, methanogenesis and fermentation, with the accumulation of inorganic carbon, organic metabolites (4-hydroxybenzaldehyde, 4-hydroxybenzoic acid), acetate, Mn(II), Fe(II), S(-II), CH4 and H2 in the plume. Aerobic and NO3-reducing processes are restricted to a 2-m-thick plume fringe but Mn(IV)-/Fe(II)-reduction, SO4-reduction, methanogenesis and fermentation occur concomitantly in the plume. Dissolved H2 concentrations in the plume vary from 0.7 to 110 nM and acetate concentrations reach 200 mg l(-1). The occurrence of a mixed redox system and concomitant terminal electron accepting processes (TEAPs) could be explained with a partial equilibrium model based on the potential in situ free energy (deltaGr) yield for oxidation of H2 by specific TEAPs. Respiratory processes rather than fermentation are rate limiting in determining the distribution of H2 and TEAPs and H2 dynamics in this system. Most (min. 90%) contaminant degradation has occurred by aerobic and NO3-reducing processes at the plume fringe. This potential is determined by the supply of aqueous O2 and NO3 from uncontaminated groundwater, as controlled by transverse mixing, which is limited in this aquifer by low dispersion. Consumption to date of mineral oxides and SO4 is, respectively, <0.15% and 0.4% of the available aquifer capacity, and degradation using these oxidants is <10%. Fermentation is a significant process in contaminant turnover, accounting for 21% of degradation products present in the plume, and indicating that microbial respiration rates are slow in comparison with fermentation. Under present conditions, the potential for degradation in the plume is very low due to inhibitory effects of the contaminant matrix. Degradation products correspond to <22% mass loss over the life of the plume, providing a first-order plume scale half-life >140 years. The phenolic compounds are biodegradable under the range of redox conditions in the aquifer and the aquifer is not oxidant limited, but the plume is likely to be long-lived and to expand. Degradation is likely to increase only after contaminant concentrations are reduced and aqueous oxidant inputs are increased by dispersion of the plume. The results imply that transport processes may exert a greater control on the natural attenuation of this plume than aquifer oxidant availability.  相似文献   

19.
Remedial dredging of contaminated bed sediments in rivers and lakes results in the suspension of sediment solids in the water column, which can potentially be a source for evaporation of hydrophobic organic compounds (HOCs) associated with the sediment solids. Laboratory experiments were conducted in an oscillating grid chamber to simulate the suspension of contaminated sediments and flux to air from the surface of the water column. A contaminated field sediment from Indiana Harbor Canal (IHC) and a laboratory-inoculated University Lake (UL) sediment, Baton Rouge, LA, were used in the experiments, where water and solids concentration and particle size distribution were measured in addition to contaminant fluxes to air. A transient model that takes into account contaminant desorption from sediment to water and evaporation from the water column was used to simulate water and sediment concentrations and air fluxes from the solids suspension. In experiments with both sediments, the total suspended solids (TSS) concentration and the average particle diameter of the suspended solids decreased with time. As expected, the evaporative losses were higher for compounds with higher vapor pressure and lower hydrophobicity. For the laboratory-inoculated sediment (UL), the water concentrations and air fluxes were high initially and decreased steadily implying that contaminant release to the water column from the suspended solids was rapid, followed by evaporative decay. For the field sediments (IHC), the fluxes and water concentrations increased initially and subsequently decreased steadily. This implied that the initial desorption to water was slow and that perhaps the presence of oil and grease and aging influenced the contaminant release. Comparison of the model and experimental data suggested that a realistic determination of the TSS concentration that can be input into the model was the most critical parameter for predicting air emission rates.  相似文献   

20.
Numerical experiments of non-reactive and reactive transport were carried out to quantify the influence of a seasonally varying, transient flow field on transport and natural attenuation at a hydrocarbon-contaminated field site. Different numerical schemes for solving advective transport were compared to assess their capability to model low transversal dispersivities in transient flow fields. For the field site, it is shown that vertical plume spreading is largely inhibited, particularly if sorption is taken into account. For the reactive simulations, a biodegradation reaction module for the geochemical transport model PHT3D was developed. Results of the reactive transport simulations show that under the site-specific conditions the temporal variations in groundwater flow do, to a modest extent, affect average biodegradation rates and average total (dissolved) contaminant mass in the aquifer. The model simulations demonstrate that the seasonal variability in groundwater flow only results in significantly enhanced biodegradation rates when a differential sorption of electron donor (toluene) and electron acceptor (sulfate) is assumed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号