首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The changing contaminant pattern with travelled distance was investigated in the anaerobic groundwater plume downstream from an extended zone containing residual NAPL at a former gas manufacturing plant. With increasing distance, O- and N-heterocyclic aromatic compounds are enriched in the plume relative to the usually assessed coal tar constituents (poly- and monocyclic aromatic compounds). In a first approximation, the overall concentration decrease of the investigated compounds follows a first order overall decay. The half life distance in the plume downgradient from the source varied between 20 m for benzene and up to 167-303 m for alkyl-naphthalenes. Acenaphthene is degraded only within about 50 m downstream from the source area, then its concentration remains constant (ca. 180 microg/l) and far above the legal limit. Dimethyl-benzofurans were the most recalcitrant among all compounds which could be quantified with the analytical method available. The overall groundwater contamination in the plume is seriously underestimated if only BTEX and 16-EPA-PAHs are monitored.  相似文献   

2.
Former manufactured gas plant sites often form a widespread contaminant source in the subsurface, leading to large plumes that contain a wide variety of tar-oil related compounds. Although most of these compounds eventually degrade naturally, the relevant processes tend to be slow and inefficient, often leaving active remediation as the only viable option to eliminate the risks of toxic substances to reach potential receptors such as surface waters or drinking water wells. In this study we use a reactive transport model to analyse the fate of a contaminant plume containing acenaphthene, methylbenzofurans and dimethylbenzofurans (i) prior to the installation of an active remediation scheme and (ii) for an enhanced remediation experiment during which O(2) and H(2)O(2) were added to the contaminated groundwater through a recirculation well. The numerical model developed for this study considers the primary contaminant degradation reactions (i.e., microbially mediated redox reactions) as well as secondary and competing mineral precipitation/dissolution reactions that affect the site's hydrochemistry and/or contaminant fate. The model was calibrated using a variety of constraints to test the uncertainty on model predictions resulting from the undocumented presence of reductants such as pyrite. The results highlight the important role of reactive transport modelling for the development of a comprehensive process understanding.  相似文献   

3.
At many "real world" field sites, the number of available monitoring wells is limited due to economic or geological reasons. Under such restricted conditions, it is difficult to perform a reliable field investigation and to quantify primary lines of evidence for natural attenuation (NA), like the documentation of a decrease of contaminant mass flux in flow direction. This study reports the results of a groundwater investigation at a former manufactured gas plant situated in a Quaternary river valley in southwest Germany. The location, infrastructure and aquifer setting are typical of many industrial sites in Germany. Due to difficult drilling conditions (coarse glaciofluvial gravel deposits and an anthropogenic fill above the aquifer), only 12 monitoring wells were available for the investigation and localisation of the contaminant plume. These wells were situated along three control planes (CP) downgradient from the contaminant source, with four wells along each plane. Based on the sparse set of monitoring wells, field scale mass fluxes and first-order natural attenuation rate constants of benzene, toluene, ethylbenzene, and o-xylene and p-xylene (BTEX) and low molecular weight polycyclic aromatic hydrocarbons (PAH) were estimated utilizing different point scale and also a new integral investigation method. The results show that even at a heterogeneous site with a sparse monitoring network point scale investigation methods can provide reliable information on field scale natural attenuation rates, if a dependable flow model or tracer test data is available. If this information is not available, only the new integral investigation method presented can yield adequate results for the quantification of contaminant mass fluxes under sparse monitoring conditions.  相似文献   

4.
A 16-year study of a hydrocarbon plume shows that the extent of contaminant migration and compound-specific behavior have changed as redox reactions, most notably iron reduction, have progressed over time. Concentration changes at a small scale, determined from analysis of pore-water samples drained from aquifer cores, are compared with concentration changes at the plume scale, determined from analysis of water samples from an observation well network. The small-scale data show clearly that the hydrocarbon plume is growing slowly as sediment iron oxides are depleted. Contaminants, such as ortho-xylene that appeared not to be moving downgradient from the oil on the basis of observation well data, are migrating in thin layers as the aquifer evolves to methanogenic conditions. However, the plume-scale observation well data show that the downgradient extent of the Fe2+ and BTEX plume did not change between 1992 and 1995. Instead, depletion of the unstable Fe (III) oxides near the subsurface crude-oil source has caused the maximum dissolved iron concentration zone within the plume to spread at a rate of approximately 3 m/year. The zone of maximum concentrations of benzene, toluene, ethylbenzene and xylene (BTEX) has also spread within the anoxic plume. In monitoring the remediation of hydrocarbon-contaminated ground water by natural attenuation, subtle concentration changes in observation well data from the anoxic zone may be diagnostic of depletion of the intrinsic electron-accepting capacity of the aquifer. Recognition of these subtle patterns may allow early prediction of growth of the hydrocarbon plume.  相似文献   

5.
Natural attenuation of an acidic plume in the aquifer underneath a uranium mill tailings pond in Wyoming, USA was simulated using the multi-component reactive transport code PHREEQC. A one-dimensional model was constructed for the site and the model included advective-dispersive transport, aqueous speciation of 11 components, and precipitation-dissolution of six minerals. Transport simulation was performed for a reclamation scenario in which the source of acidic seepage will be terminated after 5 years and the plume will then be flushed by uncontaminated upgradient groundwater. Simulations show that successive pH buffer reactions with calcite, Al(OH)3(a), and Fe(OH)3(a) create distinct geochemical zones and most reactions occur at the boundaries of geochemical zones. The complex interplay of physical transport processes and chemical reactions produce multiple concentration waves. For SO4(2-) transport, the concentration waves are related to advection-dispersion, and gypsum precipitation and dissolution. Wave speeds from numerical simulations compare well to an analytical solution for wave propagation.  相似文献   

6.
In 1994, New Zealand's only mainland Antarctic base, Vanda Station, was removed from the shores of Lake Vanda, in the McMurdo Dry Valleys region of southern Victoria Land, Antarctica. Residual chemical contamination of the station site has been identified, in the form of discrete fuel spills, locally elevated Pb, Zn, Ag and Cd concentrations in soil and elevated Cu, Ni, Co and phosphate concentrations in suprapermafrost fluids in a gully formerly used for domestic washing water disposal. Pathways for contaminant transfer to Lake Vanda, potential environmental impacts and specific remediation/monitoring options are considered. While some contaminants (particularly Zn) could be selectively leached from flooded soil, during a period of rising lake level, the small area of contaminated soils exposed and low level of contamination suggests that this would not adversely affect either shallow lake water quality or the growth of cyanobacteria. Phosphate-enhanced growth of the latte may, however, be a visible consequence of the minor contamination occurring at this site.  相似文献   

7.
Subsurface contamination by trichloroethene (TCE) was detected at a Michigan National Priorities List (NPL) site in 1982. The TCE plume resulted from the disposal of spent solvent and other chemicals at an industrial facility located in the eastern shore of Lake Michigan. TCE degradation products of three dichloroethene (DCE) isomers, vinyl chloride (VC) and ethene were present. The plume was depleted of oxygen and methanogenic at certain depths. Transects of the plume were sampled by slotted auger borings the year after the TCE plume was first discovered. Water samples were also taken from lake sediments to a depth of 12 m about 100 m offshore. Later samples were taken along the shoreline of the lake with a hand-driven probe. Later in 1998 water was taken from sediments about 3-m from the shoreline. The average concentration of each chemical and net apparent base coefficient between appropriate pairs of transects between the lower site and lakeshore were calculated. Loss rates were then calculated from an analytical solution of the two-dimensional advective-dispersive-reactive transport equation. Net apparent rate coefficients and a set of coupled reaction rate equations were used to extract the apparent loss coefficients. This study showed the field evidence for natural attenuation of TCE.  相似文献   

8.
A multidisciplinary study of a crude-oil contaminated aquifer shows that the distribution of microbial physiologic types is strongly controlled by the aquifer properties and crude oil location. The microbial populations of four physiologic types were analyzed together with permeability, pore-water chemistry, nonaqueous oil content, and extractable sediment iron. Microbial data from three vertical profiles through the anaerobic portion of the contaminated aquifer clearly show areas that have progressed from iron-reduction to methanogenesis. These locations contain lower numbers of iron reducers, and increased numbers of fermenters with detectable methanogens. Methanogenic conditions exist both in the area contaminated by nonaqueous oil and also below the oil where high hydrocarbon concentrations correspond to local increases in aquifer permeability. The results indicate that high contaminant flux either from local dissolution or by advective transport plays a key role in determining which areas first become methanogenic. Other factors besides flux that are important include the sediment Fe(II) content and proximity to the water table. In locations near a seasonally oscillating water table, methanogenic conditions exist only below the lowest typical water table elevation. During 20 years since the oil spill occurred, a laterally continuous methanogenic zone has developed along a narrow horizon extending from the source area to 50-60 m downgradient. A companion paper [J. Contam. Hydrol. 53, 369-386] documents how the growth of the methanogenic zone results in expansion of the aquifer volume contaminated with the highest concentrations of benzene, toluene, ethylbenzene, and xylenes.  相似文献   

9.

The water balance for the site Mühleggerköpfl in the North Tyrolean Limestone Alps has been established to a soil depth of 50 cm. The evaporation amounts to 42% and deep percolation is 58 % of the precipitation. The surface runoff was negligible and therefore the according nitrate fluxes as well. Soil water analysis revealed mean nitrate concentrations of 3 to 15 mg NO3 L−1, depending on soil depth. The nitrate concentrations at 50 cm soil depth and the associated percolation rates led to NO2 N outputs of 15.9 kg NO3 N ha−1 in the year 1999 and 7.9 kg NO3 N ha−1 in the year 2000.

  相似文献   

10.
Contamination of industrial sites by wood preservatives such as chromated copper arsenate (CCA) may pose a serious threat to groundwater quality. The objective of this study was to characterise the spatial variability of As and Cr concentrations in the solid phase and in the soil water at a former wood impregnation plant and to reveal the fundamental transport processes. The soil was sampled down to a depth of 2m. The soil water was extracted in situ from the vadose zone over a period of 10 months at depths of 1 and 1.5m, using large horizontally installed suction tubes. Groundwater was sampled from a depth of 4.5m. Results showed that arsenic and chromium had accumulated in the upper region of the profile and exhibited a high spatial variability (As: 21-621 mg kg(-1); Cr: 74-2872 mg kg(-1)). Concentrations in the soil water were high (mean As 167 microg L(-1); Cr: 62 microg L(-1)) and also showed a distinct spatial variability, covering concentration ranges up to three orders of magnitude. The variability was caused by the severe water-repellency of the surface soil, induced by the concurrent application of creosote wood preservatives, which leads to strong preferential flow as evident from a dye experiment. In contrast to soil water concentrations, only low As concentrations (<12 microg L(-1)) were detected in the groundwater. High Cr concentrations in the groundwater (approx. 300 microg L(-1)), however, illustrated the pronounced mobility of chromium. Our study shows that at sites with a heterogeneous flow system in the vadose zone a disparity between flux-averaged and volume-averaged concentrations may occur, and sampling of soil water might not be adequate for assessing groundwater concentrations. In these cases long-term monitoring of the groundwater appears to be the best strategy for a groundwater risk assessment.  相似文献   

11.
The influence of black carbon (BC) on the sorption of 17 native polychlorinated-p-dibenzodioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was studied in five soil samples from a sawmill site where wood used to be impregnated with chlorophenol preservatives. The presence of BC caused measured total organic carbon (TOC)-water distribution ratios (K(TOC)) to be a median factor of 51 (interquartile range 18-68, n=85) higher than modeled amorphous organic carbon (AOC)-water distribution ratios (K(AOC)). K(TOC) was a factor of 73+/-27 above K(AOC) for PCDFs (n=10) and a factor of 20+/-13 (n=7) for PCDDs. The reason for this difference is probably that attaining a planar configuration after sorption to BC is less thermodynamically favorable for PCDDs than for PCDFs. BC-water distribution ratios were calculated from K(TOC), K(AOC) and BC contents, and ranged from 10(9.9) (2,3,7,8-Tetra-CDD) to 10(11.5) l kg(-1) (Octa-CDF). More than 90% of the PCDD/Fs in the soil was calculated to be BC-sorbed. Dissolved organic carbon (DOC)-water distribution ratios were measured to be in the same order of magnitude as K(AOC). This study shows that strong sorption to BC should be included when assessing ecotoxicological risk or modeling transport to groundwater of PCDD/Fs in soil.  相似文献   

12.
Natural attenuation assessment data, collected at a Superfund site located in Louisiana, USA, are presented. The study site is contaminated with large quantities of DNAPL waste products. Source characterization data indicated that chlorinated ethene and ethane compounds are the major contaminants of concern. This case study illustrates the steps involved in implementing the U.S. EPA's [U.S. EPA, 1998. Technical protocol for evaluating natural attenuation of chlorinated solvents in ground water, by Wiedmeier, T.H., Swnason, M.A., Moutoux, D.E., Gordon, E.K., Wilson, J.T., Wilson, B.H., Kampbell, D.H., Hass, P.E., Miller, R.N., Hansen, J. E., Chapelle, F.H., Office of Research and Development, EPA/600/R-98/128] monitored natural attenuation (MNA) screening protocol at this chlorinated solvent site. In the first stage of the MNA assessment process, the field data collected from four monitoring wells located in different parts of the plume were used to complete a biodegradation scoring analysis recommended by the protocol. The analysis indicates that the site has the potential for natural attenuation. In the second stage, a detailed conceptual model was developed to identify various contaminant transport pathways and exposure points. The U.S. EPA model and BIOCHLOR was used to assess whether the contaminants are attenuating at a reasonable rate along these transport paths so that MNA can be considered as a feasible remedial option for the site. The site data along with the modeling results indicate that the chlorinated ethene and chlorinated ethane plumes are degrading and will attenuate within 1000 ft down gradient from the source, well before reaching the identified exposure point Therefore, MNA can be considered as one of the feasible remediation options for the site.  相似文献   

13.
Environmental remediation decisions are driven by the need to minimize human health and ecological risks posed by environmental releases. The Risk Assessment Guidance for Superfund Sites enunciates the principles of exposure and risk assessment that are to be used for reaching remediation decisions for sites under Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Experience with remediation management under CERCLA has led to recognition of some crucial infirmities in the processes for managing remediation: cleanup management policies are ad hoc in character, mandates and practices are strongly conservative, and contaminant risk management occurs in an artificially narrow context. The purpose of this case study is to show how a policy of risk-based decision-making was used to avoid customary pitfalls in site remediation. This case study describes the risk-based decision-making process in a remedial action program at a former manufactured gas plant site that successfully achieved timely and effective cleanup. The remediation process operated outside the confines of the CERCLA process under an administrative consent order between the utility and the New Jersey Department of Environmental Protection. A residential use end state was negotiated as part of this agreement. The attendant uncertainties, complications, and unexpected contingencies were overcome by using the likely exposures associated with the desired end state to structure all of the remediation management decisions and by collecting site-specific information from the very outset to obtain a detailed and realistic characterization of human health risks that needed to be mitigated. The lessons from this case study are generalizable to more complicated remediation cases, when supported by correspondingly sophisticated technical approaches.  相似文献   

14.
Determining water movement through contaminated sediment is critical for characterizing transport of chemicals from the sediment to the overlying water. Field studies to characterize the water flow across the sediment-water interface within a river adjacent to a former manufactured gas plant site were conducted. For this purpose, a new design of an interfacial flow meter was developed and tested. The in situ components of the system consisted of: a cylinder with an interfacial area of 2342 cm2; a dome attached to the cylinder; and a flow tube that allows water to flow from inside the dome to the river at the rate equal to the specific discharge across the sediment-water boundary. A 'heat-pulse' method was used to measure flow by heating the center of the flow tube for a brief time period and measuring the temperature profile within the tube over time. The system was calibrated to measure volumetric flux in the range 1.5-4.0 cm d(-1), however using a flow-addition method, the measurement of lower velocities also was accomplished, and calibration at higher fluxes is possible. From the groundwater flow at the interface of the coal-tar impacted sediment and information on the sediment pore water concentrations of several PAHs (poly-cyclic aromatic hydrocarbons), the mass flux of these PAHs to the river were estimated. Information on PAH mass flux at the sediment-water interface is useful for site assessment, including the evaluation of remediation alternatives and longer term site characterization.  相似文献   

15.
Even though dry deposition and air–water exchange of semivolatile organic compounds (SOCs) are important for surfaces in and around the urban areas, there is still no generally accepted direct measurement technique for dry deposition. In this study, a modified water surface sampler (WSS) configuration, including a filter holder and an XAD-2 resin column, was employed to investigate the polycyclic aromatic hydrocarbon (PAH) dry deposition in an urban area. The measured total (particle+dissolved) PAH fluxes to the WSS averaged to be 34 960±16 540 ng m−2 d−1. Average particulate PAH flux, determined by analyzing the filter in the WSS, was about 8% of the total PAH flux. Temporal flux variations indicated that colder months (October–April) had the highest PAH fluxes. This increase could be attributed to the residential heating as well as meteorological effects including lower mixing height. A high volume air sampler was concurrently employed to collect ambient air concentrations. The average total (gas+particle) atmospheric PAH concentration (456±524 ng m−3) was within the range of previously measured values at different urban locations. PAH concentrations in urban areas are more than two orders of magnitude higher than those measured in pristine areas and this result may indicate that urban areas have major source sectors and greater deposition rates are expected near to these areas. The average contribution of particle phase was about 10% in total concentration. Simultaneous particulate phase dry deposition and ambient air samples were collected in this study. Then, particulate phase apparent dry deposition velocities were calculated using the fluxes and concentrations for each PAH compound and they ranged from 0.1 to 1.2 cm s−1. These values are in good agreement with previously reported values.  相似文献   

16.
The natural attenuation of polyaromatic hydrocarbons (PAHs) in the vadose zone of a naturally revegetated former industrial sludge basin (0.45 ha) was examined. This was accomplished by comparing the concentration of 16 PAH contaminants present in sludge collected below the root zone of plants with contaminants present at 3 shallower depths within the root zone. Chemical analysis of 240 samples from 60 cores showed the average concentration of total and individual PAHs in the 0-30 cm, 30-60 cm, and bottom of the root zone strata were approximately 10, 20, and 50%, respectively, of the 16, 800 ppm average total PAH concentration in deep non-rooted sludge. Statistically significant differences in average PAH concentrations were observed between each strata studied and the non-rooted sludge except for the concentrations of acenaphthene and chrysene present at the bottom of the root zone in comparison to sludge values. The rooting depth of the vegetation growing in the basin was dependent on both vegetation type and plant age. Average rooting depths for trees, forbs (herbaceous non-grasses), and grasses were 90, 60, and 50 cm, respectively. The deepest root systems observed (100-120 cm) were associated with the oldest (12-14 year-old) mulberry trees. Examination of root systems and PAH concentrations at numerous locations and depths within the basin indicated that plant roots and their microbially active rhizospheres fostered PAH disappearance; including water insoluble, low volatility compounds, i.e. benzo(a)pyrene and benzo(ghi)perylene. The reduced concentration of PAHs in the upper strata of this revegetated former sludge basin indicated that natural attenuation had occurred. This observation supports the concept that through appropriate planting and management practices (phytoremediation) it will be possible to accelerate, maximize, and sustain natural processes, whereby even the most recalcitrant PAH contaminants (i.e. benzo(a)pyrene) can be remediated over time.  相似文献   

17.
Aerosol physical and chemical properties were measured in a forest site in central Amazonia (Cuieiras reservation, 2.61S; 60.21W) during the dry season of 2004 (Aug–Oct). Aerosol light scattering and absorption, mass concentration, elemental composition and size distributions were measured at three tower levels (Ground: 2 m; Canopy: 28 m, and Top: 40 m). For the first time, simultaneous eddy covariance fluxes of fine mode particles and volatile organic compounds (VOC) were measured above the Amazonian forest canopy. Aerosol fluxes were measured by eddy covariance using a Condensation Particle Counter (CPC) and a sonic anemometer. VOC fluxes were measured by disjunct eddy covariance using a Proton Transfer Reaction Mass Spectrometer (PTR-MS). At nighttime, a strong vertical gradient of phosphorus and potassium in the aerosol coarse mode was observed, with higher concentrations at Ground level. This suggests a source of primary biogenic particles below the canopy. Equivalent black carbon measurements indicate the presence of light-absorbing aerosols from biogenic origin. Aerosol number size distributions typically consisted of superimposed Aitken (76 nm) and accumulation modes (144 nm), without clear events of new particle formation. Isoprene and monoterpene fluxes reached respectively 7.4 and 0.82 mg m?2 s?1 around noon. An average fine particle flux of 0.05 ± 0.10 106 m?2 s?1 was calculated, denoting an equilibrium between emission and deposition fluxes of fine mode particles at daytime. No significant correlations were found between VOC and fine mode aerosol concentrations or fluxes.  相似文献   

18.
19.
This study focused on evaluating and quantifying the potential of natural attenuation of groundwater at a petroleum-contaminated site in an industrial area of a satellite city of Seoul, Korea. Groundwater at the study site was contaminated with toluene, ethylbenzene and xylene (TEX). Eight rounds of groundwater sampling and subsequent chemical analyses were performed over a period of 3 years. The groundwater quality data suggests that TEX concentrations at this site have been decreasing with time and that the TEX plume is at a quasi-steady state. Trend analysis, changes in mass flux and plume area also confirmed that the TEX plume has reached a quasi-steady state. The proportion of the total attenuation attributable to biodegredation has decreased over the monitoring period while contribution of other attenuating processes, such as dilution or dispersion, has increased. Based on the calculated attenuation rates, it would take more than 20 years to clean up the site by natural attenuation alone.  相似文献   

20.
In the North Tyrolean Limestone Alps a site was investigated over a four-year period (1998–2001) in order to assess the nitrogen saturation status, the nitrogen budget (quantification of the net uptake of nitrogen by the canopy and of the nitrogen mineralization, nitrogen uptake from roots and N2O emission rates, proof of the origin of nitrate in the soil water with stable isotope analyses), and the effects of the actual nitrogen input on ground water quality. The main goals were to quantify the nitrogen input rate, the nitrogen pools in above-ground and below-ground compartments, nitrogen turnover processes in the soil as well as the output into the groundwater and into the atmosphere. The findings are based on continuous and discontinuous field measurements as well as on model results.While nitrogen input exceeded the Critical Loads of the WHO (1995), nitrogen deficiency and nutrient imbalances were verified by needle analyses. The atmospheric input of inorganic nitrogen was higher than the nitrogen output in 50 cm soil depth. A tracer experiment with15N helped to prove that not more than half of the applied nitrate could be discharged. This allows the conclusion that nitrogen is stored in the system and that the site cannot yet be said to be saturated with nitrogen. The same result was also obtained by modelling. In addition, it was proved that the nitrogen discharge did not stem from deposition but from processes within the system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号