首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mitigation of radon gas and radon progeny in buildings is based largely on reducing the pressure difference between the point of the radiation source and the point of entry to indoor air. This study identifies the influence of mechanical systems, of air-conditioning and 'wet' systems of central heating as potential remediation agents in the control of radon and progeny concentrations. Air-conditioning was found to reduce radon levels in a systematic way within a few hours of start-up, to a low fraction of the immediately preceding concentration. Central heating reduced the level by around 40% of the preceding high within a few hours of start-up. Importantly for health concerns, under operating conditions of both types of system the level of radon progeny was reduced to a greater extent than the radon progenitor.  相似文献   

2.
Monitoring of chemical and physical groundwater parameters has been carried out worldwide in seismogenic areas with the aim to test possible correlations between their spatial and temporal variations and strain processes. Uranium (U) groundwater anomalies were observed during the preparation phases of the recent L'Aquila earthquake of 6th April 2009 in the cataclastic rocks near the overthrust fault crossing the deep underground Gran Sasso National Laboratory. The results suggest that U may be used as a potential strain indicator of geodynamic processes occurring before the seismic swarm and the main earthquake shock. Moreover, this justifies the different radon patterns before and after the main shock: the radon releases during and after the earthquake are much than more during the preparatory period because the process does not include only the microfracturing induced by stress-strain activation, but also radon increases accompanying groundwater U anomalies.  相似文献   

3.
The radon isotope 222Rn and salinity in coastal surface water were mapped on regional scales, to improve the understanding of coastal processes and their spatial variability. Radon was measured with a surface-towed, continuously recording multi-detector setup on a moving vessel. Numerous processes and locations of land-ocean interaction along the Central Great Barrier Reef coastline were identified and interpreted based on the data collected. These included riverine fluxes, terrestrially-derived fresh submarine groundwater discharge (SGD) and the tidal pumping of seawater through mangrove forests. Based on variations in the relationship of the tracers radon and salinity, some aspects of regional freshwater inputs to the coastal zone and to estuaries could be assessed. Concurrent mapping of radon and salinity allowed an efficient qualitative assessment of land-ocean interaction on various spatial and temporal scales, indicating that such surveys on coastal scales can be a useful tool to obtain an overview of SGD locations and processes.  相似文献   

4.
We have developed a simple and portable technique for measuring moderately high levels of 222Rn (t1/2=3.8d) in natural waters such as coastal water, groundwater, and river water. The water sample is carefully collected in a glass bottle, and the sample bottle is connected to a radon-in-air monitor in a closed air-loop mode. By purging air through the sample, radon is emanated from the water until a chemical equilibration is obtained between the two phases. The radon in the air loop is determined using the radon-in-air monitor. Then, the radon in water is calculated by a radon-partitioning factor between water and air for a measured water temperature. This technique is especially convenient for determination of 222Rn in natural waters on field sites, since it eliminates the preparation of He gas, cold traps, and alpha-scintillation cells and counter, which are required for traditional radon emanation methods.  相似文献   

5.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

6.
Submarine groundwater discharge (SGD) into the coastal zone has received increased attention in the last few years as it is now recognized that this process represents an important pathway for material transport. Assessing these material fluxes is difficult, as there is no simple means to gauge the water flux. To meet this challenge, we have explored the use of a continuous radon monitor to measure radon concentrations in coastal zone waters over time periods from hours to days. Changes in the radon inventories over time can be converted to fluxes after one makes allowances for tidal effects, losses to the atmosphere, and mixing with offshore waters. If one assumes that advective flow of radon-enriched groundwater (pore waters) represent the main input of 222Rn in the coastal zone, the calculated radon fluxes may be converted to water fluxes by dividing by the estimated or measured 222Rn pore water activity. We have also used short-lived radium isotopes (223Ra and 224Ra) to assess mixing between near-shore and offshore waters in the manner pioneered by. During an experiment in the coastal Gulf of Mexico, we showed that the mixing loss derived from the 223Ra gradient agreed very favorably to the estimated range based on the calculated radon fluxes. This allowed an independent constraint on the mixing loss of radon-an important parameter in the mass balance approach. Groundwater discharge was also estimated independently by the radium isotopic approach and was within a factor of two of that determined by the continuous radon measurements and an automated seepage meter deployed at the same site.  相似文献   

7.
To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m(-3), whereas the range of air exchange rate was 0.3-0.8 (h(-1)).  相似文献   

8.
In order to evaluate the influence of faulting on the variability of geogenic radon at detailed scale (1:2000), data on gamma ray fluxes, U and Th concentrations in rocks, radon in soil-gas and radon in groundwater were collected in three target areas on the Oliveira do Hospital region (Central Portugal). This region stands on the Iberian Uranium Province, and is dominantly composed of Hercynian granites and metasedimentary rocks of pre-Ordovician age, crosscut by faults with dominant strike N35°E, N55°E and N75°E. Radiometric anomalies are frequent, associated with faults of the referred systems and metasedimentary enclaves; the analytical data confirms that these anomalies are produced by local high uranium contents in rocks and fault-filling materials (n = 34, range 13-724 ppm), while other radiogenic elements are relatively constant (e.g. Th 4-30 ppm). Radon concentration in soil can be extremely high, up to 12,850 kBq m−3 (n = 215), with a large proportion of results above 100 kBq m−3. Unsurprisingly, groundwater also shows high radon concentrations, with observed values in the range 150-4850 Bq.L−1 (n = 17). From the results it is concluded that metasedimentary enclaves, as well as faults, can accumulate uranium from circulating fluids, and as a consequence, strongly locally enhance geogenic radon potential. Due to this fact, for the purpose of land use planning in such uranium-enriched regions, very detailed geological mapping is needed to precisely recognize radon high risk areas. A correlation between radon concentration in soil or in groundwater and gamma ray fluxes was established pointing to the possible use of these fluxes as a first step in assessing geogenic radon potential, at least to geological setting similar to the study area.  相似文献   

9.
Radon gas occurs naturally in the environment with variable distribution, concentrating sufficiently in the built environment in some areas to pose a public health risk. Radon levels can be successfully reduced in affected buildings, and large-scale remediation programmes have been justified in terms of accrued costs and benefits. We present results from a house where radon levels in the main living-room and master bedroom were monitored on an hourly basis over extended periods before and after radon remediation by sub-slab depressurisation. These results were combined with results from a recent occupancy survey to estimate the health impact on occupants spending varying times in the home. Prior to remediation, mean hourly radon exposure is moderately linearly correlated (R(2)=0.66-0.78) with time spent in the house. Following remediation, correlation is significantly enhanced (R(2)=0.91-0.95), but the exposure reduction of an occupant following remediation is less than that predicted using the NRPB protocol.  相似文献   

10.
Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces.  相似文献   

11.
Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).  相似文献   

12.
Evaluation was made of the distribution of radon gas and radiation exposure rates in the four main natural gas treatment facilities in Syria. The results showed that radiation exposure rates at contact of all equipment were within the natural levels (0.09-0.1 microSvh(-1)) except for the reflex pumps where a dose rate value of 3 microSvh(-1) was recorded. Radon concentrations in Syrian natural gas varied between 15.4 Bq m(-3) and 1141 Bq m(-3); natural gas associated with oil production was found to contain higher concentrations than the non-associated natural gas. In addition, radon concentrations were higher in the central processing facilities than the wellheads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its decay products. Moreover, the lowest 222Rn concentration was in the natural gas fraction used for producing sulfur; a value of 80 Bq m(-3) was observed. On the other hand, maximum radon gas and its decay product concentrations in workplace air environments were found to be relatively high in the gas analysis laboratories; a value of 458 Bq m(-3) was observed. However, all reported levels in the workplaces in the four main stations were below the action level set by IAEA for chronic exposure situations involving radon, which is 1000 Bq m(-3).  相似文献   

13.
Radon gas contributes a significant fraction of the natural background radiation dose, and in some areas raised levels are found in buildings. both homes and the workplace. Different UK Action Levels apply to homes and the workplace. because of the diurnal variation of radon. This study reviews the results for a number of hospitals throughout England and Wales. and suggests that the likelihood of finding raised radon levels is similar in the workplace and homes in the same area. Radon measurements and consequent remediation of any raised levels are appropriate in all workplaces in radon Affected Areas with over 5% of houses above the UK domestic Action Level of 200 Bq m(-3).  相似文献   

14.
Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored continuously throughout a 5-week period during which active sub-slab depressurisation remediation measures were installed. Remediation of the property was accomplished successfully, with both the mean radon levels and the diurnal variability greatly reduced both upstairs and downstairs. Following remediation, upstairs and downstairs radon concentrations were 33% and 18% of their pre-remediation values respectively: the mean downstairs radon concentration was lower than that upstairs, with pre- and post-remediation values of the upstairs/downstairs concentration ratio, R(U/D), of 0.81 and 1.51 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 h or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure difference prior to remediation; this correlation disappears following remediation. Overall, these observations provide further evidence that radon concentration levels within a dwelling are not necessarily wholly determined by the effects of soil-gas advection, and further support the suggestion that, depending on the precise content of the building materials, upstairs radon levels, in particular, may be dominated by radon exhalation from the walls of the dwelling, especially in areas of low soil-gas radon.  相似文献   

15.
This study concerns measurements of radon and thoron emissions from soil carried out in 2004 on the eastern flank of Mt. Etna, in a zone characterized by the presence of numerous seismogenic and aseismic faults. The statistical treatment of the geochemical data allowed recognizing anomaly thresholds for both parameters and producing distribution maps that highlighted a significant spatial correlation between soil gas anomalies and tectonic lineaments. The seismic activity occurring in and around the study area during 2004 was analyzed, producing maps of hypocentral depth and released seismic energy. Both radon and thoron anomalies were located in areas affected by relatively deep (5-10 km depth) seismic activity, while less evident correlation was found between soil gas anomalies and the released seismic energy. This study confirms that mapping the distribution of radon and thoron in soil gas can reveal hidden faults buried by recent soil cover or faults that are not clearly visible at the surface. The correlation between soil gas data and earthquakes depth and intensity can give some hints on the source of gas and/or on fault dynamics.  相似文献   

16.
The seasonal variation of 222Rn concentrations in the air of tunnels constructed during World War II at Nagano City has been investigated. The determination of 222Rn concentrations in tunnel air was performed using a solid-state nuclear track detector technique. The monthly radon concentrations changed smoothly, decreasing towards winter and increasing towards summer, and it was found that the concentrations strongly correlate with the temperature difference between the inside and the outside of the tunnel. In the innermost areas of the tunnel, the maximum concentration was observed in July, its value being about 6500 Bq m (-3). The concentrations of radon in the tunnel air decrease exponentially towards the openings of the tunnel, which indicates that the radon concentration in the tunnel is basically governed by diffusion and mixing of radon gas with air. These observations lead to the conclusion that the seasonal variation of the radon concentration in the tunnel air is mainly caused by a convection current due to a stack effect induced by the temperature difference between the tunnel air and the outside air.  相似文献   

17.
The seasonal variation of 222Rn concentrations in the air of tunnels constructed during World War II at Nagano City has been investigated. The determination of 222Rn concentrations in tunnel air was performed using a solid-state nuclear track detector technique. The monthly radon concentrations changed smoothly, decreasing towards winter and increasing towards summer, and it was found that the concentrations strongly correlate with the temperature difference between the inside and the outside of the tunnel. In the innermost areas of the tunnel, the maximum concentration was observed in July, its value being about 6500 Bq m (-3). The concentrations of radon in the tunnel air decrease exponentially towards the openings of the tunnel, which indicates that the radon concentration in the tunnel is basically governed by diffusion and mixing of radon gas with air. These observations lead to the conclusion that the seasonal variation of the radon concentration in the tunnel air is mainly caused by a convection current due to a stack effect induced by the temperature difference between the tunnel air and the outside air.  相似文献   

18.
Although radon can be present within buildings at sufficient levels to pose a health risk, levels can be reduced relatively easily. Recent studies on a group of radon-remediated homes, based on assessment of collective population-average risk coefficients, have estimated the benefits and cost effectiveness accruing from remediation and have confirmed that domestic remediation in UK radon Affected Areas would result in significantly reduced cancer risks to the population in those areas. Although the population-average approach used hitherto has applied occupancy and lung-cancer risk factors, these are potentially misleading in assessing discrete populations. The study reported here uses the recently developed European Community Radon Software (ECRS) to quantify individual risks in a sample of householders who remediated their homes following indications that radon levels exceeded the action level. The study proceeds from population-averaged to 'individual risk' evaluation, successfully comparing individual and collective risk assessments, and demonstrates that those who remediate are not representative of the general population. Health benefits accruing from remediation are three times lower than expected, largely because remediators are older, live in smaller households, and smoke less than the population average, leading to the conclusion that the current strategy employed in the UK is failing to target those most at risk.  相似文献   

19.
We propose a new methodology for predicting areas with a strong potential for radon (222Rn) exhalation at the soil surface. This methodology is based on the Rn exhalation rate quantification, starting from a precise characterisation of the main local geological and pedological parameters that control the radon source and its transport to the soil/atmosphere interface. It combines a cross mapping analysis of these parameters into a geographic information system with a model of the Rn vertical transport by diffusion in the soil. The rock and soil chemical and physical properties define the entry parameters of this code (named TRACHGEO) which calculates the radon flux density at the surface. This methodology is validated from in situ measurements of radon levels at the soil/atmosphere interface and in dwellings. We apply this approach to an area located in western France and characterised by a basement displaying a heterogeneous radon source potential, as previously demonstrated by lelsch et al. (J. Environ. Radioactivity 53(1) (2001) 75). The new results obtained show that spatial heterogeneity of pedological characteristics in addition to basement geochemistry--must be taken into account to improve the mapping resolution. The TRACHGEO forecasts explain the Rn exhalation variability on a larger scale and in general correlate well with in situ observations. Moreover, the radon-prone sectors identified by this approach generally correspond to the location of the dwellings showing the highest radon concentrations.  相似文献   

20.
A Radon Potential Map as well as a mean indoor Radon Concentration Map is available from the Austrian National Radon Project (1992-2002). These maps are based on the average Radon Potential/Concentration within every municipality and they sort municipalities into three radon ‘risk’ classes. This is a convenient way for the administration, but it does not describe the real radon risk distribution within a municipality because of the often inhomogeneous geological situation. Therefore, a combination of indoor radon data with all relevant parameters such as house type, storey and ventilation rates along with geological information should be used to improve the existing radon maps. The method, described here, uses Bayes' theory to combine the Radon Potential derived from indoor radon measurements with information from geology. The existing Radon Potential Map was improved by using available soil gas radon data at certain geological units and extrapolated transfer factors. The modifications of the map are shown and several problems arising with the application of this technique are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号