首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquefied natural gas (LNG) is widely used to cost-effectively store and transport natural gas. However, a spill of LNG can create a vapor cloud, which can potentially cause fire and explosion. High expansion (HEX) foam is recommended by the NFPA 11 to mitigate the vapor hazard and control LNG pool fire. In this study, the parameters that affect HEX foam performance were examined using lab-scale testing of foam temperature profile and computational fluid dynamics (CFD) modeling of heat transfer in vapor channels. A heat transfer model using ANSYS Fluent® was developed to estimate the minimum HEX foam height that allows the vapors from LNG spillage to disperse rapidly. We also performed a sensitivity analysis on the effect of the vaporization rate, the diameter of the vapor channel, and the heat transfer coefficient on the required minimum height of the HEX foam. It can be observed that at least 1.2 m of HEX foam in height are needed to achieve risk mitigation in a typical situation. The simulation results can be used not only for understanding the heat transfer mechanisms when applying HEX foam but also for suggesting to the LNG facility operator how much HEX foam they need for effective risk mitigation under different conditions.  相似文献   

2.
Natural gas is a kind of clean, efficient green energy source, which is used widely. Liquefied natural gas (LNG) is produced by cooling natural gas to −161 °C, at which it becomes the liquid. Once LNG was released, fire or explosion would happen when ignition source existed nearby. The high expansion foam (Hi-Ex foam) is believed to quickly blanket on the top of LNG spillage pool and warm the LNG vapor to lower the vapor cloud density at the ground level and raising vapor buoyancy. To identify the physical structure after it contacted with LN2 and to develop heat transfer model, the small-scale field test with liquid nitrogen (LN2) was designed. In experiment, three layers including frozen ice layer, frozen Hi-Ex layer and soft layer of Hi-Ex foam were observed at the steady state. By characterizing physical structure of the foam, formulas for calculating the surface of single foam bubble and counting foam film thickness were deduced. The micro heat transfer and evaporation model between cryogenic liquid and Hi-Ex foam was established. Indicating the physical structure of the frozen ice layer, there were a certain number of icicles below it. The heat transfer and evaporation mathematical model between the frozen ice layer and LNG was derived. Combining models above with the heat transfer between LNG, ground and cofferdam, the heat transfer and evaporation mathematical model of LNG covered by Hi-Ex foam was developed eventually. Finally, LN2 evaporation rate calculated by this model was compared with the measured evaporation rate. The calculated results are 1.2–2.1 times of experimental results, which were acceptable in engineering and proved the model was reliable.  相似文献   

3.
The evaluation of exclusion (hazard) zones around the LNG stations is essential for risk assessment in LNG industry. In this study, computational fluid dynamics (CFD) simulations have been conducted for the two potential hazards, LNG flammable vapor dispersion and LNG pool fire radiation, respectively, to evaluate the exclusion zones. The spatial and temporal distribution of hazard in complex spill scenario has been taken into account in the CFD model. Experimental data from Falcon and Montoir field tests have been used to validate the simulation results. With the valid CFD model, the mitigation of the vapor dispersion with spray water curtains and the pool fire with high expansion foam were investigated. The spray water curtains were studied as a shield to prevent LNG vapor dispersing, and two types of water spray curtain, flat and cone, were analyzed to show their performance for reduction and minimization of the hazard influencing distance and area. The high expansion foam firefighting process was studied with dynamic simulation of the foam action, and the characteristics of the foam action on the reduction of LNG vaporization rate, vapor cloud and flame size as well as the thermal radiation hazard were analyzed and discussed.  相似文献   

4.
In this study, we introduce a jet-type foam preparation device for use in mine dust control, which can enhance the reliability and applicability of the foam production process compared with conventional foam generators. In order to elucidate the foaming agent self-suction properties of this novel foam generator, we used a self-built experimental setup to investigate the effects of the working pressure and outlet pressure on negative pressure (vacuum degree) during foaming agent suction, as well as the functional relationship between negative pressure and the foaming agent by adding parameters. We also studied the effects of the valve opening degree on the foaming agent flow rate and addition ratio. The results showed that the working pressure and outlet pressure affected the formation of negative pressure in a positive linear manner and a negative linear manner, respectively. Thus, the negative pressure increased linearly as the working pressure increased, whereas it decreased in a linear manner as the outlet pressure increased. There was also a quadratic relationship between the vacuum degree and foaming agent quantity with the piecewise characteristics of the growth process, where they increased slowly with a lower vacuum degree but increased rapidly with a higher vacuum degree. After creating a moderate negative pressure with the water jet, the foaming agent could be added automatically at a low flow rate with a low ratio via the regulating valve on the liquid suction hose. This study provides basic information that should facilitate the application of this novel foam preparation technique.  相似文献   

5.
泡沫灭火剂在扑灭液体火灾中起到重要作用,关于低温液体蒸气云扩散控制的研究也逐渐得到应用。通过小尺寸模拟试验验证高倍泡沫加速泄漏LNG扩散的有效性,设计并进行了低温液体自然蒸发和高倍泡沫覆盖低温液体两个对照试验,测量了竖直方向上10个高度处的温度及装置整体质量,从而获取了低温液体蒸气到达泡沫层顶端时温度及蒸发速率的变化情况。结果表明,与未添加泡沫的情况对比,高倍泡沫的覆盖使泄漏低温液体在1 800 s内的蒸发量减少了6.4%,如果时间更长则减少的比例更多,且蒸发出的低温液体穿过泡沫层后蒸气温度可达0℃左右,而未添加泡沫时同等高度处蒸气温度为-75℃左右。0℃时,LNG蒸气密度已明显小于空气密度,此温度下LNG蒸气会迅速向上扩散,而不至在地表积聚,由此证明高倍泡沫能够加速泄漏低温液体蒸气向上扩散,减小了低温液体蒸气在地面积聚并引发火灾爆炸事故的可能性,从而证实了高倍泡沫加速泄漏LNG扩散的有效性。  相似文献   

6.
Foam is used as part of an effective dust suppression method in underground coal mines, but conventional foaming devices severely restrict its popularization and application due to the high cost of foam preparation, poor applicability and high pressure loss. Therefore, a new spiral mesh foam generator is designed, and its performance is investigated and evaluated experimentally. The results show that the pressure gradient of the spiral mesh foam generator increases with the increase of foam concentration in water. There is a large pressure gradient gap between the top and bottom at both ends of the foam generator. However, the gap disappears and uniform foam is generated in the middle section of the foam generator. When the pressure gradient is higher than minimum pressure gradient, the foam production quantity will increase sharply. Based on the length of spiral mesh and operating conditions determined, the new foam generator is applied to produce foam for dust suppression in the heading face of coal mines. A good foaming effect, less pressure loss and high dust suppression efficiency suggest that the new foam generator will greatly promote the large-scale application of foam technology used to suppress dust in underground coal mines.  相似文献   

7.
低温液氮与泡沫混合液直接接触产生氮气泡沫是一种新型的掺混形式,利用液氮高汽化比的特点,搭建液氮泡沫可视化实验装置,进行氮气-水两相流及液氮泡沫流动特性的研究。结果表明,液氮相变产生大量氮气,其与泡沫液混合产生泡沫,温度有所回升,最终趋于泡沫混合液温度;管路沿程压降较小;液氮射流破碎及流动过程可分为6个区域:低温液氮区、向上循环翻滚区、滞留区、泡沫与泡沫混合液混合区、致密泡沫区、泡沫混合液区。流体向下游流动过程中持续发泡;为防止管路结冰,需合理控制泡沫混合液与液氮流量。  相似文献   

8.
The siting of facilities handling liquefied natural gas (LNG), whether for liquefaction, storage or regasification purposes, requires the hazards from potential releases to be evaluated. One of the consequences of an LNG release is the creation of a flammable vapor cloud, that may be pushed beyond the facility boundaries by the wind and thus present a hazard to the public. Therefore, numerical models are required to determine the footprint that may be covered by a flammable vapor cloud as a result of an LNG release. Several new models have been used in recent years for this type of simulations. This prompted the development of the “Model evaluation protocol for LNG vapor dispersion models” (MEP): a procedure aimed at evaluating quantitatively the ability of a model to accurately predict the dispersion of an LNG vapor cloud.This paper summarizes the MEP requirements and presents the results obtained from the application of the MEP to a computational fluid dynamics (CFD) model – FLACS. The entire set of 33 experiments included in the model validation database were simulated using FLACS. The simulation results are reported and compared with the experimental data. A set of statistical performance measures are calculated based on the FLACS simulation results and compared with the acceptability criteria established in the MEP. The results of the evaluation demonstrate that FLACS can be considered a suitable model to accurately simulate the dispersion of vapor from an LNG release.  相似文献   

9.
Effective safety measures to prevent and mitigate the consequences of an accidental release of flammable LNG are critical. Water spray curtain is currently recognized as an effective technique to control and mitigate various hazards in the industries. It has been used to absorb, dilute and disperse both toxic and flammable vapor cloud. It is also used as protection against heat radiation, in case of fighting vapor cloud fire. Water curtain has also been considered as one of the most economic and promising LNG vapor cloud control techniques. Water curtains are expected to enhance LNG vapor cloud dispersion mainly through mechanical effects, dilution, and thermal effects. The actual phenomena involved in LNG vapor and water curtain interaction were not clearly established from previous research. LNG spill experiments have been performed at the Brayton Fire Training Field at Texas A&M University (TAMU) to understand the effect of water curtain in controlling and dispersing LNG vapor cloud. This paper summarizes experimental methodology and presents data from two water curtain tests. The analysis of the test results are also presented to identify the effectiveness of these two types of water spray curtains in enhancing the LNG vapor cloud dispersion.  相似文献   

10.
An underwater LNG release test was conducted to understand the phenomena that occur when LNG is released underwater and to determine the characteristic of the vapor emanating from the water surface. Another objective of the test was to determine if an LNG liquid pool formed on the water surface, spread and evaporated in a manner similar to that from an on-the-surface release of LNG.A pit of dimensions 10.06 m × 6.4 m and 1.22 m depth filled with water to 1.14 m depth was used. A vertically upward shooting LNG jet was released from a pipe of 2.54 cm diameter at a depth of 0.71 m below the water surface. LNG was released over 5.5-min duration, with a flow rate of 0.675 ± 0.223 L/s. The wind speed varied between 2 m/s and 4 m/s during the test.Data were collected as a function of time at a number of locations. These data included LNG flow rate, meteorological conditions, temperatures at a number of locations within the water column, and vapor temperatures and concentrations in air at different downwind locations and heights. Concentration measurements were made with instruments on poles located at 3.05 m, 6.1 m and 9.14 m from the downwind edge of the pit and at heights 0.46 m, 1.22 m, and 2.13 m. The phenomena occurring underwater were recorded with an underwater video camera. Water surface and in-air phenomena including the dispersion of the vapor emanating from the water surface were captured on three land-based video cameras.The lowest temperature recorded for the vapor emanating from the water surface was −1 °C indicating that the vapor emitted into air was buoyant. In general the maximum concentration observed at each instrument pole was progressively at higher and higher elevations as one traveled downwind, indicating that the vapor cloud was rising. These findings from the instrument recorded data were supported by the visual record showing the “white” cloud rising, more or less vertically, in air. No LNG pool was observed on the surface of water. Discussions are provided on the test findings and comparison with predictions from a previously published theoretical model.  相似文献   

11.
Quantifying the size of flammable vapor cloud hazards associated with an accidental release of Liquefied Natural Gas (LNG) into a spill containment system supported by narrow drainage trenches has posed a modeling challenge since the inception of the LNG industry. Early attempts to treat the vapors evolving from the trenches included using line-source Gaussian models, and the use of the DEGADIS model by modeling “segmented” trench elements and adding the contributions from each trench segment at a specified downwind distance. These approaches often are only reasonable for a select set of conditions (e.g., winds perpendicular to the trench) and have no ability to simulate many of the conditions that might result in a larger potential impact (e.g., winds blowing parallel to the trench).  相似文献   

12.
水成膜泡沫在油类表面的窒息作用是扑灭油类火灾的重要机理之一,针对自行开发的快速型泡沫灭火剂开展了其对油池火的窒息灭火特性研究。首先通过老化试验测试了泡沫液的热稳定性,然后对比了不同成分泡沫液在25#变压器油表面的铺展特性,之后研究了不同发泡倍率和成分的泡沫液对油池火的窒息灭火效果及影响规律。研究发现,铺展性能不佳的泡沫液会逐渐丧失窒息能力,而铺展性能优异的泡沫液能持续发挥窒息作用。提升泡沫液热稳定性有利于在油面形成稳定的液膜,隔绝氧气并降低可燃分子挥发速率。此外,发泡倍率较低的泡沫液的流动性更强,在相同液体流量条件下低倍数泡沫的窒息灭火效果更优。自研的快速型泡沫灭火剂在热稳定性和铺展性能两方面均具备优良的性能,因此其窒息灭火效率和抗复燃能力优于现有的大部分同类泡沫灭火剂。  相似文献   

13.
A failure of a Liquefied Natural Gas (LNG) tanker can occur due to collision or rupture in loading/unloading lines resulting in spillage of LNG on water. Upon release, a spreading liquid can form a pool with rapid vaporization leading to the formation of a flammable vapor cloud. Safety analysis for the protection of public and property involves the determination of consequences of such accidental releases. To address this complex pool spreading and vaporization phenomenon of LNG, an investigation is performed based on the experimental tests that were conducted by the Mary Kay O'Connor Process Safety Center (MKOPSC) in 2007. The 2007 tests are a part of medium-scale experiments carried out at the Brayton Fire Training Field (BFTF), College Station. The dataset represents a semi-continuous spill on water, where LNG is released on a confined area of water for a specified duration of time. The pool spreading and vaporization behavior are validated using empirical models, which involved determination of pool spreading parameters and vaporization rates with respect to time. Knowledge of the pool diameter, pool height and spreading rate are found to be important in calculating the vaporization rates of the liquid pool. The paper also presents a method to determine the vaporization mass flux of LNG using water temperature data that is recorded in the experiment. The vaporization rates are observed to be high initially and tend to decrease once the pool stopped spreading. The results of the analysis indicated that a vaporization mass flux that is varying with time is required for accurate determination of the vaporization rate. Based on the data analysis, sources of uncertainties in the experimental data were identified to arise from ice formation and vapor blocking.  相似文献   

14.
One of the scenarios of concern in assessing the safety issues related to transportation of LNG in a marine environment (ship or underwater pipeline) is the release of LNG underwater. This scenario has not been given the same level of scientific attention in the literature compared to surface releases and assessment of consequences therefrom. This paper addresses questions like, (1) does an LNG spill underwater form a pool on the water surface and subsequently evaporate like an LNG spill “on the surface” producing cold, heavier than air vapors?, and (2) what is the range of expected temperatures of the vapor, generated by LNG release due to heat transfer within the water column, when it emanates from the water surface?Very limited data from two field tests of LNG underwater release are reviewed. Also presented are the results from tests conducted in other related industries (metal casting, nuclear fission and fusion, chemical processing, and alternative fuel vehicles) where a hot (or cold) liquid is injected into a bulk cold (or hot) liquid at different depths.A mathematical model is described which calculates the temperature of vapor emanating at the water surface, and the liquid fraction of released LNG that surfaces, if any, to form a pool on the water surface. The model includes such variables as the LNG release rate, diameter of the jet at release, depth of release and water body temperature. Results obtained from the model for postulated release conditions are presented. Comparison of predicted results with available LNG underwater release test data is also provided.  相似文献   

15.
16.
The need for sustainable energy sources, as well as the current energetic crisis involving the majority of markets, has promoted the use of cryogenic liquefaction for the transportation and storage of natural gas (i.e., LNG). To guarantee the development of a robust and safe infrastructure, a complete understanding of the main phenomena occurring at low temperatures is paramount. In this sense, the largest grey areas are the characterization of the combustion at low-initial temperature and the interactions between water and cryogenic liquid. For these reasons, this work presents an experimental campaign on the possible mitigation strategies for the mitigation of consequences related to the accidental release of LNG. Particular emphasis was posed on the direct and indirect effects of water on cryogenic pool fire. The former resulted in a significant increase in the dimensions of fire (∼+50%) and burning rate (∼300%) with respect to the case with no direct contact between water and LNG, whereas the latter generated an abrupt decrease in the measured temperatures (<100 °C). The use of an emergency flare to empty an LNG tank was tested, as well. The spatial distribution of temperature was monitored along with the time to guarantee the safe operability of this equipment in the case of LNG combustion. The explanations for the observed phenomena and trends were provided, allowing for the development of safe procedures for the emergency response related to cryogenic fuels.  相似文献   

17.
Evaluating potential hazards caused by accidental LNG release from underwater pipelines or vessels is a significant consideration in marine transportation safety. The aim of this study was to capture the dynamic behavior of LNG jet released under water and to analyze its vapor dispersion characteristics and combustion characteristics on the water surface during different release scenarios. Controlled experiments were conducted where LNG was jet released from a cryogenic storage tank. The dynamic process of LNG being jet released from orifices of different sizes and shapes, as well as the rising plume structure, were captured by a high-speed camera. The leakage flow rate and pipeline pressure were recorded by a flow meter and pressure gauge, respectively. The concentration distribution that emanated from the water surface was measured utilizing methane sensors in different positions with various wind speeds. The flame combustion characteristics of LNG vapor clouds, which immediately ignited upon the enclosed water tank, were also recorded. Additionally, the mass burning rate of the flame on the water surface was evaluated, and a new correlation between the ratio of flame length and width was established. The results indicated a large dimensionless heat release rate (Q*) and a continuous release flow rate in a limited burning area. This study could provide greater understanding of the mechanisms of LNG release and combustion behavior under water.  相似文献   

18.
采用实验室压缩气体泡沫系统,通过缩尺油盘火试验,分别考察基于不同气源的压缩气体泡沫对于石油醚火灾的灭火性能,分析探讨适用于低沸点的石油醚类燃料火灾扑救的气源类型和供气方案。结果表明,在泡沫溶液供给强度为2.5 L/(min·m2)的条件下,压缩氮气泡沫和压缩空气泡沫均可扑灭石油醚火灾,具有良好的抗烧性能;二者相比,压缩氮气泡沫比压缩空气泡沫的控灭火性能和抗烧性能均有一定提升;对于石油醚类的低沸点易燃液体火灾,建议采用以氮气作为气源的压缩氮气泡沫系统;该研究可为压缩气体泡沫系统在石油化工行业工程应用提供技术支撑。  相似文献   

19.
王鹏 《火灾科学》2015,24(4):221-228
为了研究抗醇泡沫灭火剂在水溶性有机溶剂表面的铺展能力,发明了一种新的实验方法,正交实验了9种配方。得到了粘度、发泡倍数和表面张力对铺展能力的影响数据,通过方差分析验证了数据的可靠性。研究发现抗醇泡沫灭火剂的粘度和发泡倍数可以影响其在醇类表面的铺展能力,但是表面张力对铺展无影响。对于泡沫的铺展存在一个最佳粘度和最差发泡倍数。扩散系数不能表征抗醇泡沫灭火剂在水溶性有机溶剂表面的铺展能力。  相似文献   

20.
Foam technology is more efficient than water sprays for dust control in coal mines, but the traditional foam system is complex and poses problems related to foam production and spraying application, with high water consumption, unstable equipment and relatively low utilization efficiency of foam. This paper describes an optimized foam system which overcomes these disadvantages. The proposed foam generator has a self-suction unit that uses a turbulent-flow water jet to automatically draw in ambient air and foaming agent, thereby eliminating the need for compressed-air hoses and pipes. As well as simplifying the system, it solves the current problem of water backflow created by high-pressure compressed air. A refined foam spraying structure was developed for use in conjunction with an operating roadheader as it produces and diffuses dust. The structure consists of foam distribution supports and arc-fan nozzles. It can produce a more focused, continuous and uniform coverage at the source of the dust. The optimized system consumes less water and foaming agent, and achieves greater dust-suppression efficiency than methods in current use.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号