1.
The amount of light scattered by airborne particles inside an aerosol photometer will vary not only with the mass concentration, but also with particle properties such as size, shape, and composition. This study conducted controlled experiments to compare the measurements of a real-time photometer, the SidePak AM510 monitor (SidePak), with gravimetric mass. PM sources tested were outdoor aerosols, and four indoor combustion sources: cigarettes, incense, wood chips, and toasting bread. The calibration factor for rescaling the SidePak measurements to agree with gravimetric mass was similar for the cigarette and incense sources, but different for burning wood chips and toasting bread. The calibration factors for ambient urban aerosols differed substantially from day to day, due to variations in the sources and composition of outdoor PM. A field evaluation inside a casino with active smokers yielded calibration factors consistent with those obtained in the controlled experiments with cigarette smoke.  相似文献   

2.
Evidence on the correlation between particle mass and (ultrafine) particle number concentrations is limited. Winter- and spring-time measurements of urban background air pollution were performed in Amsterdam (The Netherlands), Erfurt (Germany) and Helsinki (Finland), within the framework of the EU funded ULTRA study. Daily average concentrations of ambient particulate matter with a 50% cut off of 2.5 microm (PM2.5), total particle number concentrations and particle number concentrations in different size classes were collected at fixed monitoring sites. The aim of this paper is to assess differences in particle concentrations in several size classes across cities, the correlation between different particle fractions and to assess the differential impact of meteorological factors on their concentrations. The medians of ultrafine particle number concentrations were similar across the three cities (range 15.1 x 10(3)-18.3 x 10(3) counts cm(-3)). Within the ultrafine particle fraction, the sub fraction (10-30 nm) made a higher contribution to particle number concentrations in Erfurt than in Helsinki and Amsterdam. Larger differences across the cities were found for PM2.5(range 11-17 microg m(-3)). PM2.5 and ultrafine particle concentrations were weakly (Amsterdam, Helsinki) to moderately (Erfurt) correlated. The inconsistent correlation for PM2.5 and ultrafine particle concentrations between the three cities was partly explained by the larger impact of more local sources from the city on ultrafine particle concentrations than on PM2.5, suggesting that the upwind or downwind location of the measuring site in regard to potential particle sources has to be considered. Also, relationship with wind direction and meteorological data differed, suggesting that particle number and particle mass are two separate indicators of airborne particulate matter. Both decreased with increasing wind speed, but ultrafine particle number counts consistently decreased with increasing relative humidity, whereas PM2.5 increased with increasing barometric pressure. Within the ultrafine particle mode, nucleation mode (10-30 nm) and Aitken mode (30-100 nm) had distinctly different relationships with accumulation mode particles and weather conditions. Since the composition of these particle fractions also differs, it is of interest to test in future epidemiological studies whether they have different health effects.  相似文献   

3.
The aim of this study was to compare the performance of the TSI Aerodynamic Particle Sizer (APS) and the TSI portable photometer SidePak to measure airborne oil mist particulate matter (PM) with aerodynamic diameters below 10 μm, 2.5 μm and 1 μm (PM(10), PM(2.5) and PM(1)). Three SidePaks each fitted with either a PM(10), PM(2.5) or a PM(1) impactor and an APS were run side by side in a controlled chamber. Oil mist from two different mineral oils and two different drilling fluid systems commonly used in offshore drilling technologies were generated using a nebulizer. Compared to the APS, the SidePaks overestimated the concentration of PM(10) and PM(2.5) by one order of magnitude and PM(1) concentrations by two orders of magnitude after exposure to oil mist for 3.3-6.5 min at concentrations ranging from 0.003 to 18.1 mg m(-3) for PM(10), 0.002 to 3.96 mg m(-3) for PM(2.5) and 0.001 to 0.418 mg m(-3) for PM(1) (as measured by the APS). In a second experiment a SidePak monitor previously exposed to oil mist overestimated PM(10) concentrations by 27% compared to measurements from another SidePak never exposed to oil mist. This could be a result of condensation of oil mist droplets in the optical system of the SidePak. The SidePak is a very useful instrument for personal monitoring in occupational hygiene due to its light weight and quiet pump. However, it may not be suitable for the measurement of particle concentrations from oil mist.  相似文献   

4.
Five different instruments for the determination of the mass concentration of PM10 in air were compared side-by-side for up to 33 days in an undisturbed indoor environment: a tripod mounted BGI Inc. PQ100 gravimetric sampler with a US EPA certified Graseby Andersen PM10 inlet; an Airmetrics Minivol static gravimetric sampler; a Casella cyclone gravimetric personal sampler; an Institute of Occupational Medicine gravimetric PM10 personal sampler; and two TSI Inc. Dustrak real-time optical scattering personal samplers. For 24 h sampling of ambient PM10 concentrations around 10 microg m(-3), the estimated measurement uncertainty for the two gravimetric personal samplers was larger (approximately +/- 20%) compared with estimated measurement uncertainty for the PQ100/Graseby Andersen sampler (< +/- 5%). Measurement uncertainty for the Dustraks was lower (approximately +/- 15% on average) but calibration of the optical response against a reference PM10 method is essential since the Dustraks systematically over-read PM10 determined gravimetrically by a factor approximately 2.2. However, once calibrated, the Dustrak devices demonstrated excellent functionality in terms of ease of portability and real-time data acquisition. Estimated measurement uncertainty for PM10 concentrations determined with the Minivol were +/- 5%. The Minivol data correlated well with PQ100/Graseby Andersen data (r= 0.97, n = 18) but were, on average, 23% greater. The reason for the systematic discrepancy could not be traced. Intercomparison experiments such as these are essential for assessing measurement error and revealing systematic bias. Application of two Dustraks demonstrated the spatial and temporal variability of exposure to PM10 in different walking and transport microenvironments in the city of Edinburgh, UK. For example, very large exposures to PM10 were identified for the lower deck of a double-decker tour bus compared with the open upper deck of the same vehicle. The variability observed emphasises the need to determine truly personal exposure profiles of PM10 for quantifying exposure response relationships for epidemiological studies.  相似文献   

5.
Real-time particle sizers provide rapid information about atmospheric particles, particularly peak exposures, which may be important in the development of adverse health outcomes. However, these instruments are subject to erroneous readings in high-humidity environments when compared with measurements from filter-based, federal reference method (FRM) samplers. Laboratory tests were conducted to evaluate the ability of three inlet conditioners to dry aerosol prior to entering a real-time particle sizer for measuring coarse aerosols (Model 3321 Aerodynamic Particle Sizer, APS) under simulated highly humid conditions. Two 30 day field studies in Birmingham, AL, USA were conducted to compare the response of two APSs operated with and without an inlet conditioner to that measured with FRM samplers. In field studies, the correlation of PM(10-2.5) derived from the APS and that measured with the FRM was substantially stronger with an inlet conditioner applied (r2 ranged from 0.91 to 0.99) than with no conditioner (r2 = 0.61). Laboratory experiments confirmed the ability of the heater and desiccant conditioner to remove particle-borne moisture. In field tests, water was found associated with particles across the sizing range of the APS (0.5 microm to 20 microm) when relative humidity was high in Birmingham. Certain types of inlet conditioners may substantially improve the correlation between particulate mass concentration derived from real-time particle sizers and filter-based samplers in humid conditions.  相似文献   

6.
Land use regression (LUR) models have been used successfully for predicting local variation in traffic pollution, but few studies have explored this method for deriving fine particle exposure surfaces. The primary purpose of this method is to develop a LUR model for predicting fine particle or PM(2.5) mass over the five county metropolitan statistical area (MSA) of Los Angeles. PM(2.5) includes all particles with diameter less than or equal to 2.5 microns. In the Los Angeles MSA, 23 monitors of PM(2.5) were available in the year 2000. This study uses GIS to integrate data regarding land use, transportation and physical geography to derive a PM(2.5) dataset covering Los Angeles. Multiple linear regression was used to create the model for predicting the PM(2.5) surface. Our parsimonious model explained 69% of the variance in PM(2.5) with three predictors: (1) traffic density within 300 m, (2) industrial land area within 5000 m, and (3) government land area within 5000 m of the monitoring site. These results suggest the LUR method can refine exposure models for epidemiologic studies in a North American context.  相似文献   

7.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

8.
During March and April 2010 aerosol inventories from four large cities in Pakistan were assessed in terms of particle size distributions (N), mass (M) concentrations, and particulate matter (PM) concentrations. These M and PM concentrations were obtained for Karachi, Lahore, Rawalpindi, and Peshawar from N concentrations using a native algorithm based on the Grimm model 1.109 dust monitor. The results have confirmed high N, M and PM concentrations in all four cities. They also revealed major contributions to the aerosol concentrations from the re-suspension of road dust, from sea salt aerosols, and from vehicular and industrial emissions. During the study period the 24 hour average PM(10) concentrations for three sites in Karachi were found to be 461 μg m(-3), 270 μg m(-3), and 88 μg m(-3), while the average values for Lahore, Rawalpindi and Peshawar were 198 μg m(-3), 448 μg m(-3), and 540 μg m(-3), respectively. The corresponding 24 hour average PM(2.5) concentrations were 185 μg m(-3), 151 μg m(-3), and 60 μg m(-3) for the three sites in Karachi, and 91 μg m(-3), 140 μg m(-3), and 160 μg m(-3) for Lahore, Rawalpindi and Peshawar, respectively. The low PM(2.5)/PM(10) ratios revealed a high proportion of coarser particles, which are likely to have originated from (a) traffic, (b) other combustion sources, and (c) the re-suspension of road dust. Our calculated 24 hour averaged PM(10) and PM(2.5) concentrations at all sampling points were between 2 and 10 times higher than the maximum PM concentrations recommended by the WHO guidelines. The aerosol samples collected were analyzed for crustal elements (Al, Fe, Si, Mg, Ca) and trace elements (B, Ba, Cr, Cu, K, Na, Mn, Ni, P, Pb, S, Sr, Cd, Ti, Zn and Zr). The averaged concentrations for crustal elements ranged from 1.02 ± 0.76 μg m(-3) for Si at the Sea View location in Karachi to 74.96 ± 7.39 μg m(-3) for Ca in Rawalpindi, and averaged concentrations for trace elements varied from 7.0 ± 0.75 ng m(-3) for B from the SUPARCO location in Karachi to 17.84 ± 0.30 μg m(-3) for Na at the M. A. Jinnah Road location, also in Karachi.  相似文献   

9.
根据2014年全年实时在线观测数据,分析了徐州睢宁地区大气细颗粒物(PM_(2.5))和气态污染物(包括SO_2、CO、NO_x、O_3)质量浓度的季节性变化特征。结合后向轨迹模型,分析不同气团对该地区大气污染浓度的影响。PM_(2.5)与O_3值在夏季最低,呈显著相关,表明夏季PM_(2.5)主要受控于本地大气光化学活性。在冬季,除O_3外,PM_(2.5)、SO_2、CO、NO_x值最高,且大气颗粒物主要以细粒子为主。O_3在春季最高,并与远程传输的气团且经过我国东部污染源密集地区相对应。高浓度的PM_(2.5)主要与冬季缓慢移动的气团相对应,这可能将PM_(2.5)及其气态前体物传输至该地区进而加重大气污染程度。  相似文献   

10.
Samples of PM(2.5) were collected to measure the concentrations of its chemical constituents at two rural locations, Potsdam and Stockton, NY from November 2002 to August 2005. These samples were collected on multiple filters at both sites, every third day for a 24-h interval with a speciation network sampler. The Teflo(R) filters were analyzed for PM(2.5) mass by gravimetry, and elemental composition by X-ray fluorescence (XRF). Nylasorb(R) filters and Teflo(R) filters were leached with water and analyzed for anions and cations, respectively, by ion chromatography (IC). Fine particulate matter (PM(2.5)) mass and its inorganic component measurements were statistically characterized, and the temporal behavior of these species were assessed. Over the entire study period, PM(2.5) mass concentrations were lower at Potsdam (8.35 mug/m(3)) than at Stockton (10.24 mug/m(3)). At both locations, organic matter (OM) was the highest contributor to mass. Sulfate was the second highest contributor to mass at 27.0% at Potsdam, and 28.7% at Stockton. Nitrate contributions to mass of 8.9 and 9.5% at Potsdam and Stockton, respectively, were the third highest. At both locations, fine PM mass exhibited an annual cycle with a pronounced summer peak and indications of another peak during the winter, consistent with an overall increase in the rate of secondary aerosol formation during the summer, and increased partitioning of ammonium nitrate to the particle phase and condensation of other semi-volatiles during the winter, respectively. An ion-balance analysis indicated that at both locations, during the summers as well as in the winters, the aerosol was acidic. Lognormal frequency distribution fits to the measured mass concentrations on a seasonal basis indicated the overall increase in particle phase secondary aerosol (sulfate and SOA) concentrations during the summers compared to the winters at both locations.  相似文献   

11.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

12.
Long-term observations of atmospheric constituents such as aerosol particles are increasingly needed to assess their impact on climate and human health. In contrast to particle mass concentration (MC), there are currently no standardized quality control (QC) and quality assurance (QA) procedures for the measurement of particle size distribution (PSD). This study describes some fundamental QC and QA procedures associated with the collection and evaluation of a 2 year dataset between 2005 and 2006 at an urban background monitoring site in Augsburg, Germany. The considered parametres include ambient PSD between 3 nm and 10 microm (merged from a twin differential mobility and an aerodynamic particle sizer, TDMPS and APS, respectively) as well as total particle number (TNC), length (LC) and MC determined by independent instruments. The hourly 1st and 0th moment of PSD showed good correlations with the independently measured LC (R(2) = 0.86) and TNC (R(2) = 0.79), respectively, the deviation for LC with 4% and for TNC with 22% being rather small. The volume concentration (3rd moment) of hourly measured PSD and the resultant MC (when assuming a realistic apparent density of 1.5 g cm(-3)) correlated well with the independently measured MC of PM(2.5) or PM(10) (R(2) > 0.86) and showed only small deviation from PM(2.5) (1%) or PM(10) (5%), respectively. The study demonstrates that the described QC and QA measures define both a high accuracy of the PSD measurements and their long-term comparability against data obtained in similar measurement programmes.  相似文献   

13.
An investigation to find out presence of particulate matter in Marikana, a mining area in Rustenburg town, South Africa, was carried out in the months of August and November of 2008. Samples were collected for measurements of particulate matter (PM) of particle diameters of PM10, PM2.5, and PM1. After gravimetric analysis of daily measurements, it was found that PM10 concentration values ranged between 3 and 9 ??g/m3, PM2.5 concentration values ranged between 16 and 26 ??g/m3, and PM1 concentration values ranged between 14 and 18 ??g/m3 for the month of August 2008. For the month of November, it was found that PM10 concentration values ranged between 2 and 8 ??g/m3, PM2.5 concentration values ranged between 0 and 5 ??g/m3, and PM1 concentration values ranged between 4 and 15 ??g/m3. This study was undertaken as preliminary work having in mind that mining activities could be emitting high levels of particulate matter in the atmosphere which might be degrading the quality of the air. It was observed, however, that the daily particulate matter especially of PM10 emitted were quite low when compared to laid down International Air Quality Standards. The standards did not give guidelines for particulate matter of diameter 2.5 ??m. It was concluded that particulate matter came from three major sources: platinum mining, domestic biomass burning, and traffic emissions due to fuel burning.  相似文献   

14.
青岛市区春夏季大气能见度与颗粒物的关系   总被引:8,自引:0,他引:8  
利用青岛市灰霾综合观测站2012年3月2日-2012年6月7日期间的监测数据,分析了青岛市区大气能见度与不同粒径颗粒物质量浓度的日变化特征,比较了各级别大气能见度下不同粒径颗粒物质量浓度及所占比例的相关性,研究了相对湿度对大气能见度和颗粒物质量浓度相关性的影响.结果表明,监测时段大气能见度与颗粒物质量浓度呈现较好的负相关,每天大气能见度最低值出现在早晨07:00--09:00;剔除相对湿度高于90%的前提下,PM2.5是影响大气能见度的主要因子,随着其在PM1o中所占比例上升,大气能见度级别不断下降,相关系数为-0.84;不同相对湿度区间下,PM2.5对大气能见度的影响最明显,其中,相对湿度为60% ~ 70%,大气能见度与颗粒物质量浓度之间的相关性最好.  相似文献   

15.
采用在线单颗粒气溶胶质谱技术源解析方法,对桂林市PM2.5典型排放源的粒径和化学成分进行质谱分析,采集燃煤/燃气源、工业工艺源、扬尘源、油烟源4类共计7个典型排放源。结果表明,桂林市4类排放源细颗粒物的粒径分布为0.25~1.25μm,80%以上的细颗粒分布在0.2~1.0μm的小粒径范围,峰值约0.68μm。细颗粒物离子成分含有Na~+、Mg~+、K~+、NH~+4、Fe~+、Pb~+、Cd~+、V~+、Mn~+、Li~+、Al~+、Ca~+、Cu~+、Zn~+、Cr~+、CN~-、PO_3~-、NO_2~-、NO_3~-、Cl~-、SO_4~(2-)、SiO_3~-等成分,桂林市细颗粒物为元素碳、有机碳元素碳、有机碳、富锰颗粒、富铁颗粒、富钾颗粒、矿物质、左旋葡聚糖以及其他金属等9类。  相似文献   

16.
Food cooking using liquefied petroleum gas (LPG) has received considerable attention in recent years since it is an important source of particulate air pollution in indoor environments for non-smokers. Exposure to organic compounds such as polycyclic aromatic hydrocarbons (PAHs) contained in particles is of particular health concern since some of these compounds are suspected carcinogens. It is therefore necessary to chemically characterize the airborne particles emitted from gas cooking to assess their possible health impacts. In this work, the levels of fine particulate matter (PM(2.5)) and 16 priority PAHs were determined in three different ethnic commercial kitchens, specifically Chinese, Malay and Indian food stalls, where distinctive cooking methods were employed. The mass concentrations of PM(2.5) and PAHs, and the fraction of PAHs in PM(2.5) were the highest at the Malay stall (245.3 microg m(-3), 609.0 ng m(-3), and 0.25%, respectively), followed by the Chinese stall (201.6 microg m(-3), 141.0 ng m(-3), and 0.07%), and the Indian stall (186.9 microg m(-3), 37.9 ng m(-3), and 0.02%). This difference in the levels of particulate pollution among the three stalls may be attributed to the different cooking methods employed at the food stalls, the amount of food cooked, and the cooking time, although the most sensitive parameter appears to be the predominant cooking method used. Frying processes, especially deep-frying, produce more air pollutants, possibly due to the high oil temperatures used in such operations. Furthermore, it is found that frying, be it deep-frying at the Malay stall or stir-frying at the Chinese stall, gave rise to an abundance of higher molecular weight PAHs such as benzo[b]fluoranthene, indeno[1,2,3-cd]pyrene and benzo[g,h,i]perylene whereas low-temperature cooking, such as simmering at the Indian stall, has a higher concentration of lower molecular weight PAHs. In addition, the correlation matrices and diagnostic ratios of PAHs were calculated to determine the markers of gas cooking. To evaluate the potential health threat due to inhalation exposure from the indoor particulate pollution, excess lifetime cancer risk (ELCR) was also calculated for an exposed individual. The findings suggest that cooking fumes in the three commercial kitchens pose adverse health effects.  相似文献   

17.
As users of indoor climbing gyms are exposed to high concentrations (PM(10) up to 4000 μg m(-3); PM(2.5) up to 500 μg m(-3)) of hydrated magnesium carbonate hydroxide (magnesia alba), reduction strategies have to be developed. In the present paper, the influence of the use of different kinds of magnesia alba on dust concentrations is investigated. Mass concentrations, number concentrations and size distributions of particles in indoor climbing gyms were determined with an optical particle counter, a synchronized, hybrid ambient real-time particulate monitor and an electrical aerosol spectrometer. PM(10) obtained with these three different techniques generally agreed within 25%. Seven different situations of magnesia alba usage were studied under controlled climbing activities. The use of a suspension of magnesia alba in ethanol (liquid chalk) leads to similar low mass concentrations as the prohibition of magnesia alba. Thus, liquid chalk appears to be a low-budget option to reduce dust concentrations. Magnesia alba pressed into blocks, used as powder or sieved to 2-4 mm diameter, does not lead to significant reduction of the dust concentrations. The same is true for chalk balls (powder enclosed in a sack of porous mesh material). The promotion of this kind of magnesia alba as a means of exposure reduction (as seen in many climbing gyms) is not supported by our results. Particle number concentrations are not influenced by the different kinds of magnesia alba used. The particle size distributions show that the use of magnesia alba predominantly leads to emission of particles with diameters above 1 μm.  相似文献   

18.
Particulate matter suspended in the air has adverse effects onhuman health. Its level of concentration is an important parameter in evaluating the degree of hazard it poses to the atmosphere. Conventional methods used in measuring particulatematter are often filter-based, which indicates some disadvantagesbecause such a base requires labor and time. In this study, to achieve real-time measurements, a new electrical method was developed for measuring PM10 and PM2.5 concentrations. The basicprinciple is to electrically charge particles passing through thePM inlet using a corona charger and measure the currents createdby charged particles to obtain the number concentration of particulate matter. A new type inlet based on the particle cupimpactor configuration was designed and its performance was evaluated. A unipolar diffusion charger was developed and thecharger's efficiency was determined experimentally in terms ofPn, which represents the penetration through the charger,P, times the average charge number acquired by a particle,n, for different particle sizes. The correlation was constructed between the PM10 (or the PM2.5) mass concentrationsand the electrical currents due to particles, which were chargedby the diffusion charger.  相似文献   

19.
质谱直接测量法解析盐城市大气细颗粒物来源   总被引:3,自引:0,他引:3  
为全面了解盐城市大气颗粒物的组成,摸清以PM2.5为首要污染物的来源,说清其化学组分和源贡献率,于2014年12月16日00:00—2014年12月21日09:00,利用在线单颗粒气溶胶质谱仪,对盐城市细颗粒物进行实时在线源解析。结果表明,盐城首要污染物为燃煤,占比为23.7%,其次是机动车尾气,占比为18.3%,第三位是扬尘,占总颗粒数的15.7%,生物质燃烧占比为14.8%位列第四,工业工艺源、二次无机源和其他源贡献率相对较小。  相似文献   

20.
宁波和温州地区夏季大气中不同粒径颗粒物特征分析   总被引:1,自引:0,他引:1  
对宁波地区北仑和奉化站、温州地区乐清站3个监测点夏季TSP、PM10、PM2.5和PM1.0进行监测,测试分析各种粒径颗粒物浓度水平和粒径分布特征,并通过化学质量平衡(CMB)受体模型对颗粒物进行源解析。监测结果显示,夏季宁波、温州地区TSP和PM10日均浓度为0.049~0.134mg/m3和0.025~0.084mg/m3,均未超过我国环境空气质量二级标准;PM2.5日均浓度为0.007~0.069mg/m3,按美国2006年EPA最新标准限值0.035mg/m3衡量,奉化、乐清、北仑站的超标天数占总监测天数的比例分别为75%、40%和37.5%。粒径分布统计结果显示,3个监测站点PM10占TSP的比例为48.78%~86.96%;PM2.5占TSP的比例为33.33%~72.46%;奉化和乐清监测点PM10中PM2.5和PM1.0的比例平均值在50%以上。源解析结果显示,夏季TSP主要来源于土壤尘,其次是建筑尘和煤烟尘,其贡献率分别为40.70%~55.49%、9.62%~13.64%和5.85%~17.28%。  相似文献   