共查询到5条相似文献,搜索用时 0 毫秒
1.
2.
Qiaowen Tan Weiying Li Junpeng Zhang Wei Zhou Jiping Chen Yue Li Jie Ma 《Frontiers of Environmental Science & Engineering》2019,13(3):36
3.
Xiaojian Zhang Zilong Mi Yang Wang Shuming Liu Zhangbin Niu Pinpin Lu Jun Wang Junnong Gu Chao Chen 《Frontiers of Environmental Science & Engineering》2014,8(3):417-426
A red water phenomenon occurred in several communities few days after the change of water source in Beijing, China in 2008. In this study, the origin of this problem, the mechanism of iron release and various control measures were investigated. The results indicated that a significant increase in sulphate concentration as a result of the new water source was the cause of the red water phenomenon. The mechanism of iron release was found that the high-concentration sulphate in the new water source disrupted the stable shell of scale on the inner pipe and led to the release of iron compounds. Experiments showed that the iron release rate in the new source water within pipe section was over 11-fold higher than that occurring within the local source water. The recovery of tap water quality lasted several months despite ameliora- tive measures being implemented, including adding phosphate, reducing the overall proportion of the new water source, elevating the pH and alkalinity, and utilizing free chlorine as a disinfectant instead of chloramine. Adding phosphate was more effective and more practical than the other measures. The iron release rate was decreased after the addition of 1.5 mg. L-1 orthophosphate- P, tripolyphosphate-P and hexametaphosphate-P by 68%, 83% and 87%, respectively. Elevating the pH and alkalinity also reduced the iron release rate by 50%. However, the iron release rate did not decreased after replacing chloramine by 0.5-0.8 mg. L-1 of free chlorine as disinfectant. 相似文献
4.
Yongji ZHANG Lingling ZHOU Guo ZENG Huiping DENG Guibai LI 《Frontiers of Environmental Science & Engineering》2010,4(4):430-437
Nitrification occurs in chloraminated drinking water systems and is affected by water quality parameters. The aim of this study was to investigate the impact of total organic carbon and chlorine to ammonia ratio on nitrification potential in a simulated drinking water distribution system as during chloramination. The occurrence of nitrification and activity of nitrifying bacteria was primarily monitored using four rotating annular bioreactors (RAB) with different chlorine to ammonia ratios and total organic carbon (TOC) levels. The results indicated that nitrification occurred despite at a low influent concentration of ammonia, and a high concentration of nitrite nitrogen was detected in the effluent. The study illustrated that reactors 1(R1) and 3 (R3), with higher TOC levels, produced more nitrite nitrogen, which was consistent with the ammonia-oxidizing bacteria (AOB) counts, and was linked to a relatively more rapid decay of chloramines in comparison to their counterparts (R2 and R4). The AOB and HPC counts were correlated during the biofilm formation with the establishment of nitrification. Biofilm AOB abundance was also higher in the high TOC reactors compared with the low TOC reactors. The chlorine to ammonia ratio did not have a significant impact on the occurrence of nitrification. Bulk water with a high TOC level supported the occurrence of nitrification, and AOB development occurred at all examined chlorine to ammonia dose ratios (3:1 or 5:1). 相似文献
5.
Kun Wan Wenfang Lin Shuai Zhu Shenghua Zhang Xin Yu 《Frontiers of Environmental Science & Engineering》2020,14(1):10