首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 507 毫秒
1.
Environmental Science and Pollution Research - Combined thermal power (CHP) production mode plays a more important role in energy production, but the impact of its pollutant emission on the natural...  相似文献   

2.

High concentration of total ammonia nitrogen (TAN) in the form of urea is known to inhibit the performance of many biological wastewater treatment processes. Microbial fuel cells (MFCs) have great potential for TAN removal due to its unique oxic/anoxic environment. In this study, we demonstrated that increased urea (TAN) concentration up to 3940 mg/L did not inhibit power output of single-chambered MFCs, but enhanced power generation by 67% and improved coulombic efficiency by 78% compared to those obtained at 80 mg/L of TAN. Over 80% of nitrogen removal was achieved at TAN concentration of 2630 mg/L. The increased nitrogen removal coupled with significantly enhanced coulombic efficiency, which was observed for the first time, indicates the possibility of a new electricity generation mechanism in MFCs: direct oxidation of ammonia for power generation. This study also demonstrates the great potential of using one MFC reactor to achieve simultaneous electricity generation and urea removal from wastewater.

  相似文献   

3.

With the rapid development of China’s economy, high energy consumption and high pollution emission have become serious problems. To solve these problems, many studies have been done to evaluate energy and environmental efficiency, as the results can provide valuable information to improve performance. However, the previous research mainly evaluates China’s regional energy and environmental efficiency by considering each region’s industry as a whole system, ignoring the internal structure. In reality, each region mainly includes three parallel types of industry: primary, secondary, and tertiary. Therefore, this paper provides a parallel data envelopment analysis (DEA) approach to evaluate China’s regional energy and environment efficiency by considering these parallel industrial systems. The following findings can be obtained based on the empirical results: (1) the overall energy efficiency of China is low, and the inefficiency of the economic system is mainly sourced from the lower energy and environmental performance of the primary industry and the tertiary industry. (2) the introduction of the environmental variable (CO2) leads to the increase of some backward areas’ efficiencies. (3) the energy efficiency of each provincial region is different, and most of them have their own inefficient industries. (4) the total factor productivity of China is declining, mainly because of the decline of technical efficiency.

  相似文献   

4.
This paper presents the performance analysis of a power plant with the Organic Rankine Cycle (ORC). The power plant is supplied by thermal energy utilized from a solar energy collector. R245fa was the working fluid in the thermodynamic cycle. The organic cycle with heat regeneration was built and tested experimentally. The ORC with a heat regenerator obtained the maximum thermodynamic efficiency of approximately 9%.  相似文献   

5.
Huang Y  Takaoka M  Takeda N 《Chemosphere》2003,52(4):735-743
The organic contaminants in municipal solid waste incineration (MSWI) fly ash, including chlorinated aromatic compounds and polycyclic aromatic hydrocarbons, have high toxicity and a potential negative impact on the environment. An effective and low energy consumption technique to remove the organic contaminants from MSWI fly ash is required urgently. Organic contaminants, such as chlorobenzenes (CBzs), in MSWI fly ash are known to become enriched in the unburnt carbon (UC) fraction. It is proposed that removal of UC from fly ash will result in the effective removal of most organic micropollutants. In this research, we use a technique of surfactant-assisted column flotation to decontaminate MSWI fly ash by removal of the CBzs-enriched UC from MSWI fly ash. We find that 39.8% of CBzs can be removed from fresh MSWI fly ash with 61.7% UC removal efficiency, whereas only 33.2% of CBzs can be removed from weathered MSWI fly ash with a low UC removal efficiency of 33.7%. By adding a mixture of two kinds of surfactants: sorbitan mono-oleate and polyoxyethylene (20) sorbitan mono-oleate to the weathered fly ash, 47.0% of CBzs were removed at the hydrophile lipophile balance value of 13.5, while the UC removal efficiency increased to 49.0%. The results show that surfactants can enhance CBzs and UC removal efficiencies during the column flotation process. Higher CBzs and UC removal efficiencies can be expected by further optimizing the conditions of surfactant-assisted column flotation.  相似文献   

6.
The recovery of silver from Ag+ solution coupled with power generation was investigated in bio-electrochemical system (BES). In this system, chemical energy existing in the organic matter in the anode chamber can be converted biologically to electrical energy which can be used for the reduction of Ag+ ions in the cathode chamber. Results showed that type of substrate influenced the metabolic pathway and affected the cell voltage progression, and columbic efficiency. Silver recovery was not affected by increasing initial pH (2.0 to 7.0) and Ag+ concentration (100 to 1000 mg/L) in the catholyte, whereas power generation was improved. A maximum power density of 8258 mW/m3 and a columbic efficiency of 21.61% could be achieved with 1000 mg/L of Ag+. Ag+ ions were reduced to form metallic deposits as Ag0 crystals on the cathode surface, which were then confirmed by scanning electron microscope (SEM) image and energy dispersive X-ray (EDX) spectrum. The BES reactor had high silver removal (i.e., >96%) after 24 h of operation. When considering the crossover of Ag+ ions through the cation exchange membrane, the removal was in the range of 83.73–92.51%. This crossover was not considerable as compared to the Ag+ initial concentration. At higher initial Ag+ concentration (2000 mg/L), the silver removal decreased to 88.61% and the maximum power density decreased to 5396 mW/m3. This study clearly showed that BES can be employed for silver recovery, wastewater treatment, and also electricity generation.  相似文献   

7.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

8.
Pollutant abatement systems are widely applied in the coal-fired power sector, and the energy consumption is considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000-MW coal-fired power unit that meets the ultra-low emission limits and the factors of operating parameters, including unit load and inlet concentration of pollutants, on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The wet flue gas desulfurization (WFGD) system consumed 67% of the rate, whereas the selective catalytic reduction (SCR) and electrostatic precipitator (ESP) systems consumed 8.9% and 24.1%, respectively. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of the WFGD system.

Implications: The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.  相似文献   


9.
The UN Global Mercury Assessment (GMA) estimates that atmospheric emissions of mercury from Australian stationary combustion sources were 97.0 tonnes for the year of 1995. This is more than 90% of the estimated emissions from stationary combustion for the whole of North America, and seems abnormally high for a country with a population of around 20 million, in spite of the fact that most of Australia's stationary energy supply is provided by coal. It is also significantly larger than previous estimates of mercury emissions from Australian sources. New estimates of Australian mercury emissions from stationary energy sources, based on both a top down and bottom up approach, are presented. These estimates can be reconciled for black coal fired power stations, but suggest that the bottom up approach (the Australian National Pollutant Inventory) significantly under-estimates emissions from brown coal fired plant, if mercury capture efficiencies in these plants are low, as observed for lignite-fired plant. The major uncertainties in these estimates are the coal mercury content in coals burnt in Australian power stations, and the mercury capture efficiency in particulate control devices used at these stations. Based on these estimates, Australian emissions of mercury from stationary energy are currently 2–8 tonnes/year, significantly lower than the GMA estimate.  相似文献   

10.
Data from the chemical analysis of moss growing close to a thermal power station and snowpack have been used for the estimation of heavy metal deposition close to the point pollution sources. A semi-empirical model was proposed to describe atmospheric trace metal deposition close to the point pollution source. Model parameters were derived from experimental data, and nickel and vanadium quantities, washed out with snow and rain, were calculated. Using long-term meteorological observation data of rain and snow duration and metal uptake efficiencies in moss, the average emission rates of vanadium and nickel from the stack were calculated. The coincidence between data from emission inventory and model results was within 25%. It was estimated that in the vicinity of pollution source (within 30 km) about 15% out of total emitted metals were washed out by rain and snow events. Metal concentrations in the environment become indistinguishable from the background at a distance of about 20 km from the stack.  相似文献   

11.

With the aim of upgrading current food waste (FW) management strategy, a novel FW hydrothermal pretreatment and air-drying incineration system is proposed and optimized from an energy and exergy perspective. Parameters considered include the extracted steam quality, the final moisture content of dehydrated FW, and the reactor thermal efficiency. Results show that optimal working condition can be obtained when the temperature and pressure of extracted steam are 159 °C and 0.17 MPa, the final moisture content of dehydrated FW is 10%, and the reactor thermal efficiency is 90%. Under such circumstance, the optimal steam energy and exergy increments reach 194.92 and 324.50 kJ/kg-FW, respectively. The novel system is then applied under the local conditions of Hangzhou, China. Results show that approximately 2.7 or 11.6% (from energy or exergy analysis perspective) of electricity can be additionally generated from 1 ton of MSW if the proposed novel FW system is implemented. Besides, comparisons between energy and exergy analysis are also discussed.

  相似文献   

12.
施加电压对铬污染土壤电动修复的影响   总被引:4,自引:0,他引:4  
试验研究了不同电压条件下电动修复去除效率和单位能耗随施加电压的变化关系,探讨了电动修复经济有效的电压范围.试验选用重铬酸钾作为污染物,配制高岭土中Cr(Ⅵ)初始质量分数为100 mg/kg和500 mg/kg,含水量为50%,试验运行48 h,用乙酸控制阴极pH在4~7之间,施加一系列不同直流电压.试验结果表明,随着施加电压升高,去除效率增大,电压升高到1 V/cm时,去除效率显著升高,2种试验土壤去除效率分别为76.7%和89.8%;同时随着施加电压增加,电能消耗显著增加,与电压呈现线性递增和幂指数递增关系;综合去除效率和单位能耗2种因素,对于试验所研究的土壤,1~1.5 V/cm的电压是较为经济有效的.  相似文献   

13.
Transportation contributes to energy consumption and greenhouse gas emissions, while sustainable mobility requires reductions in both areas. Alternative fuels from natural gas and from renewable resources can contribute in the mid and long-term to the fuel market for mobile as well as stationary applications. The lack of reliable data on emissions, energy chain efficiencies, and costs demonstrates the need for field tests and demonstration projects. Fuel cells offer the technology to use ‘new fuels’ in a highly efficient way.  相似文献   

14.
The occurrence and persistence of pharmacologically active compounds in the environment has been an increasingly important issue. The objectives of this study were to investigate the decomposition of aqueous antimicrobial compounds using activated sludge, γ-irradiation, and UV treatment, and to evaluate the toxicity towards green algae, Pseudokirchneriella subcapitata, before and after treatment. Tetracycline (TCN), lincomycin (LMC) and sulfamethazine (SMZ) were used as target compounds. Gamma (γ)-irradiation showed the highest removal efficiency for all target compounds, while UV and activated sludge treatment showed compound-dependent removal efficiencies. TCN and SMZ were well degraded by all three treatment methods. However, LMC showed extremely low removal efficiency for UV and activated sludge treatments. Overall, the algal toxicity after degradation processes was significantly decreased, and was closely correlated to removal efficiency. However, in the case of γ-irradiated TCN, UV and activated sludge treated LMC as well as sludge treated SMZ, the observed toxicity was higher than expected, which indicates the substantial generation of byproducts or transformed compounds of a greater toxicity in the treated sample. Consequently, γ-radiation treatment could be an effective method for removal of recalcitrant compounds such as antibiotics.  相似文献   

15.
Photocatalytically active thin TiO(2) films were produced by spin-coating or dip-coating an alkoxy precursor onto a transparent conducting electrode substrate and by thermal oxidation of titanium metal. The thin films were used to study the photoelectrocatalytic or photoelectrochemical degradation of oxalic acid and 4-chlorophenol (4-CP) under near UV (monochromatic, 365 nm) light irradiation. Degradation was monitored by a variety of methods. In the course of oxalic acid degradation, CO(2) formation accounted for up to 100% of the total organic carbon degradation for medium starting concentrations; for the degradation of 4-CP, less CO(2) was detected due to the higher number of oxidation steps, i.e. intermediates. Incident-photon-to-current conversion efficiency, educt degradation and product formation as well as Faradaic efficiencies were calculated for the degradation experiments. Quantum yields and Faradaic efficiencies were found to be strongly dependent on concentration, with maximum values (quantum yield) around 1 for the highest concentrations of oxalic acid.  相似文献   

16.
Coal bottom ashes produced from three thermal power plants were used in column and batch experiments to investigate the adsorption capacity of the coal ash. Hydrogen sulfide and leachates collected from three sanitary landfill sites were used as adsorbate gas and solutions, respectively. Experimental results showed that coal bottom ash could remove H2S from waste gas or reduce the concentrations of various pollutants in the leachate. Each gram of bottom ash could remove up to 10.5 mg of H2S. In treating the landfill leachate, increasing ash dosage increased the removal efficiency but decreased the adsorption amount per unit mass of ash. For these tested ashes, the removal efficiencies of chemical oxygen demand (COD), NH3-N, total Kjeldhal nitrogen (TKN), P, Fe3+, Mn2+, and Zn2+ were 36.4-50, 24.2-39.4, 27.0-31.1, 82.2-92.9, 93.8-96.5, 93.7-95.4, and 80.5-82.2%, respectively; the highest adsorption capacities for those parameters were 3.5-5.6, 0.22-0.63, 0.36-0.45, 0.027-0.034, 0.050-0.053, 0.029-0.032, and 0.006 mg/g of bottom ash, respectively. The adsorption of pollutants in the leachate conformed to Freundlich's adsorption model.  相似文献   

17.
污水处理的高能耗和新能源利用已引起人们的关注,本文根据太阳光照强度的周期变化和农村污水昼夜排放量悬殊的特征,提出了一种新型的利用无蓄电池太阳能光伏系统驱动的污水生物处理系统,可有效降低太阳能光伏系统的成本。生物反应器是一个双沟式一体化氧化沟。按照启动的用电设备的数量,一体化氧化沟具有5种运行方式。在不同的运行方式下,一体化氧化沟的内沟和外沟具有不同的功能,其中运行方式3到运行方式5对污染物去除效率最高。采用阶梯型电量输出模式,可以充分利用太阳能,并保障一体化氧化沟的高效运行时间。在160 d的连续运行实验中,COD、氨氮、总氮和总磷的平均去除率分别为87.8%、98.4%、68.7%和80.3%。证明无蓄电池太阳能光伏系统驱动污水生物反应器处理农村分散污水是可行的。  相似文献   

18.
二氧化硫和氮氧化物是电厂产生的主要大气污染物,研究焦点越来越集中在在一个反应器内实现同时脱硫脱硝。实验以H2O溶液作为吸收液,在自制的鼓泡反应器内,对模拟烟气进行同时脱硫脱硝的实验研究,实验结果表明:H2O浓度、反应温度、NO浓度、SO2浓度、烟气流量对脱除率影响显著,pH、氧含量对脱硝率影响不大。在整个实验范围内脱硫效率总是保持在98.5%以上,脱硝效率最高达到67.4%。  相似文献   

19.
Distributed power generation-electricity generation that is produced by many small stationary power generators distributed throughout an urban air basin-has the potential to supply a significant portion of electricity in future years. As a result, distributed generation may lead to increased pollutant emissions within an urban air basin, which could adversely affect air quality. However, the use of combined heating and power with distributed generation may reduce the energy consumption for space heating and air conditioning, resulting in a net decrease of pollutant and greenhouse gas emissions. This work used a systematic approach based on land-use geographical information system data to determine the spatial and temporal distribution of distributed generation emissions in the San Joaquin Valley Air Basin of California and simulated the potential air quality impacts using state-of-the-art three-dimensional computer models. The evaluation of the potential market penetration of distributed generation focuses on the year 2023. In general, the air quality impacts of distributed generation were found to be small due to the restrictive 2007 California Air Resources Board air emission standards applied to all distributed generation units and due to the use of combined heating and power. Results suggest that if distributed generation units were allowed to emit at the current Best Available Control Technology standards (which are less restrictive than the 2007 California Air Resources Board standards), air quality impacts of distributed generation could compromise compliance with the federal 8-hr average ozone standard in the region.  相似文献   

20.
热解吸对土壤中POPs农药的去除及土壤理化性质的影响   总被引:1,自引:0,他引:1  
为探索土壤热解吸修复技术对POPs污染土壤的修复效果及修复后土壤可耕作性,选择北京某农药厂旧址的POPs农药污染土壤,研究了不同温度下热解吸处理后土壤中滴滴涕(DDTs)和六六六(HCHs)各组分的去除率以及土壤理化性质的变化。结果表明,热解吸修复技术可有效去除土壤中POPs农药,其中,p,p’-DDE与α-HCH组分去除率受热解吸温度的影响比其他组分更为明显。∑HCH与∑DDT在310℃、340℃时分别达到97%、99%的去除率,且此时土壤中的污染物含量低于我国《展览会用地土壤环境质量评价标准》,此后去除率受温度的影响不明显。热解吸温度对修复后土壤的理化性质有一定的影响,不同温度影响的程度各不相同,其中,有机质含量与全氮含量分别由0.78%、0.0352%降至0.14%、0.0107%;pH波动幅度较小,由7.80变至8.25;阳离子交换量变化存在波动,但呈整体下降趋势,由7.87 mg/kg降至5.00mg/kg;土壤中速效磷显著增加,由7.59 mg/kg升至21.8 mg/kg。而在最优温度条件下,土壤理化性质受热解吸温度的影响较小。由此可以说明,热解吸技术可以用于POPs污染土壤的修复,选择适当的热解吸温度对土壤的可耕作性影响有限,因而是一种潜在的绿色修复技术。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号