首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract

Organochlorine pesticides (OCPs) were analyzed in three different ages (half-, 1.5-, 2.5-year-old) for needles and semi permeable membrane devices (SPMDs) at three deployment periods from sea level to 1881 meter above sea level. Individual HCHs concentrations ranged between 1.4 and 129?pg/g fw depending on the age and sampling season while 2.5-year-old needles showed higher HCHs levels compared to half and 1.5- year-old. Correlation between elevation and HCH concentration in SPMDs was found but not in needle samples. Concentrations of HCHs in SPMDs indicated clearly cold condensation effect on accumulation in winter period and increased with altitude. Concentrations of DDTs in half and 1.5-year-old needles were lower than 2.5-year-old needles. The highest total concentration of DDTs was detected in 1-year-period SPMD. Higher concentrations were found in 2.5-year-old needles for other OCPs. Seasonal and altitude-dependent changes were not observed for other OCPs in SMPDs. Total accumulation of OCPs in SPMDs were found higher than in needles. On the contrary, an increased accumulation rate was observed for HCHs in SPMD. In general, Total concentrations of DDTs and HCHs were similar to total of other OCPs in all altitudes when dominating endosulfan wasnot taken into account in the computation of total concentration of other OCPs.  相似文献   

2.
Semipermeable membrane devices (SPMDs) are a widely used passive sampling methodology for both waterborne and airborne hydrophobic organic contaminants. The exchange kinetics and partition coefficients of an analyte in a SPMD are mediated by its physicochemical properties and certain environmental conditions. Controlled laboratory experiments are used for determining the SPMD–air (Ksa's) partition coefficients and the exchange kinetics of organic vapors. This study focused on determining a simple approach for measuring equilibrium Ksa's for naphthalene (Naph), o-chlorophenol (o-CPh) and p-dichlorobenzene (p-DCB) over a wide range of temperatures. SPMDs were exposed to test chemical vapors in small, gas-tight chambers at four different temperatures (−16, −4, 22 and 40 °C). The exposure times ranged from 6 h to 28 d depending on test temperature. Ksa's or non-equilibrium concentrations in SPMDs were determined for all compounds, temperatures and exposure periods with the exception of Naph, which could not be quantified in SPMDs until 4 weeks at the −16 °C temperature. To perform this study the assumption of constant and saturated atmospheric concentrations in test chambers was made. It could influence the results, which suggest that flow through experimental system and performance reference compounds should be used for SPMD calibration.  相似文献   

3.
Triolein-containing semipermeable membrane devices (SPMDs) were employed as passive samplers to provide data on the bioavailable fraction of organic, waterborne, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polynuclear aromatic hydrocarbons (PAHs) in streams flowing through a highly polluted industrial area of Bitterfeld in Saxony-Anhalt, Germany. The contamination of the region with organic pollutants originates in wastewater effluents from the chemical industry, from over one-hundred years of lignite exploitation, and from chemical waste dumps. The main objective was to characterise time-integrated levels of dissolved contaminants, to use them for identification of spatial trends of contamination, and their relationship to potential pollution sources. SPMDs were deployed for 43 days in the summer of 1998 at four sampling sites. The total concentration of pollutants at sampling sites was found to range from a low of 0.8 microgram/SPMD to 25 micrograms/SPMD for PAHs, and from 0.4 microgram/SPMD to 22 micrograms/SPMD for OCPs, respectively. None of the selected PCB congeners was present at quantifiable levels at any sampling site. A point source of water pollution with OCPs and PAHs was identified in the river system considering the total contaminant concentrations and the distribution of individual compounds accumulated by SPMDs at different sampling sites. SPMD-data was also used to estimate average ambient water concentrations of the contaminants at each field site and compared with concentrations measured in bulk water extracts. The truly dissolved or bioavailable portion of contaminants at different sampling sites ranged from 4% to 86% for the PAHs, and from 8% to 18% for the OCPs included in the estimation. The fraction of individual compounds found in the freely dissolved form can be attributed to the range of their hydrophobicity. In comparison with liquid/liquid extraction of water samples, the SPMD method is more suitable for an assessment of the background concentrations of hydrophobic organic contaminants because of substantially lower method quantification limits. Moreover, contaminant residues sequestered by the SPMDs represent an estimation of the dissolved or readily bioavailable concentration of hydrophobic contaminants in water, which is not provided by most analytical approaches.  相似文献   

4.
High mountains may serve both as condenser for vapor phase persistent organic pollutants (POPs) and as barrier/sink for particulate associated less volatile POPs. The fractionation of POPs along altitudinal profiles is of interest in understanding the role of high mountains in the atmospheric transport of POPs. In the present study, polycyclic aromatic hydrocarbons (PAHs) in a selected moss species, Hypnum plumaeformae WILS, from two altitudinal profiles on the northern slope of Nanling mountains in Southern China were analyzed and compared with those in air samples. The total PAH concentration in the mosses was 310–1340 ng g−1 dry weight, with phenanthrene being the most abundant. The distribution patterns of PAHs in the moss samples matched well with those in bulk atmosphere deposition in the adjacent source areas. The PAH distribution pattern in the mosses was a composite of both particle-associated and vapor phase PAHs, with heavy PAHs are susceptible to uptake/retention by mosses than light PAHs. A plot of log (Cmoss/Cair) against log Koa gave a good linear relationship in the log Kao range of 6.7–10.2. It is suggested that the widely spread moss, H. plumaeformae WILS, can be used as an effective tool in the biomonitoring of atmospheric PAHs pollution in East Asia. The concentrations of most PAHs in the mosses generally declined with increasing altitude. In addition, there was a shift in compound pattern with an increase in the proportion of light PAHs (2–3 rings), a decrease in heavy PAHs (5–6 rings) and a relatively stable content of 4-ring PAHs. A combination of particulate scavenging and cold condensation are proposed as the major mechanisms for the compositional fractionation of PAHs along the altitudinal profile.  相似文献   

5.
Bioavailable water concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) were assessed at several freshwater sites in and around the city of Amsterdam. Carp (Cyprinus carpio) were caged for 4 weeks at 10 sites, together with semipermeable membrane devices (SPMDs). In addition, sediment samples were taken at each site. SPMDs and sediments were analysed for PAHs, PCBs and OCPs. Carp muscle tissues were analysed for PCBs and OCP, while PAH metabolites were assessed in fish bile. Contaminant concentrations in the water phase were estimated using three different methods: 1. Using fish tissue concentrations and literature bioconcentration factors (BCFs), 2. Using SPMD levels and a kinetic SPMD uptake model, and 3. Using sediment levels and literature sorption coefficients (Kocs). Since PAH accumulation in fish is not considered an accurate indicator of PAH exposure, calculated aqueous PAH concentrations from SPMD data were compared with semiquantitatively determined biliary PAH metabolite levels. Contaminant concentrations in the water phase estimated with fish data (Cwfish) and SPMD data (Cwspmd) were more in line for compounds with lower Kow than for compounds with higher Kow values. This indicates that the assumption of fish–water sorption equilibrium was not valid. At most sites, sediment-based water levels (Cwsed) were comparable with the Cwspmd, although large differences were observed at certain sites. A significant correlation was observed between biliary PAH metabolite levels in fish and aqueous PAH concentrations estimated with SPMD data, suggesting that both methods may be accurate indicators of PAH exposure in aquatic ecosystems.  相似文献   

6.
Semipermeable membrane sampling devices (SPMDs) and caged lake mussels (Anodonta piscinalis) were simultaneously deployed at four lake watercourse sites in Central Finland four weeks in August 1992. This study was part of the regular annual monitoring of the organochlorine compounds (OCC) in pulp-mill recipient watercourses of Finland with bivalves. Chlorohydrocarbons (CHCs), chlorophenol compounds (PCPs), chloroanisoles (PCAs) and chloroveratroles (PCVs) were analyzed from lipid extract of mussels and from the synthetic triolein lipid of the SPMDs. Hexane-diethyl ether (9:1, v/v) dialysis using polyethylene membrane was applied in dean up of the SPMD lipids and, for comparison, to six sets of the mussel fat. Dialysis recovered CHCs but not PCPs from the mussel fat. CHCs, PCPs, PCAs and PCVs were all recovered in dialysis of the SPMD lipid. Handling of SPMDs in the transport and deployment operations caused significant OCC contamination for the blank SPMDs. Similar trends were revealed in the OCC profiles for mussels ans SPMDs. An exception was the lack of PCPs appearing in SPMDs that did appear in mussels and in a complementary manner the appearance of the PCAs and PCVs in SPMDs.  相似文献   

7.
Triolein-filled semipermeable membrane devices (SPMDs) were immersed at three locations along the St. Joseph River in northern Indiana for 30 days to see if the PCB content of fish from the same location could be predicted with this model device. Triolein from the SPMD's was analyzed for PCB using enzyme-linked immunosorbent assay (ELISA) and compared to residues detected in fish collected from the same locations. There was a significant difference (p < 0.05) in total PCB concentrations between SPMD samples. However, due to variability in PCB residues between species and low PCB residues in SPMDs, a direct correlation between PCBs in sportfish and SPMDs could not be determined.  相似文献   

8.
Semipermeable membrane devices (SPMDs) were deployed in water using four different methods: a typical SPMD cage with and without a mesh cover, a bowl chamber and without any protection. In addition to routinely used performance reference compounds (PRCs), perdeuterated dibenz[a,h]anthracene was added. Due to its high sampler to water partition coefficient no measurable clearance due to diffusion was expected during the deployment period, hence any observed loss could be attributed to photodegradation. The loss of PRCs was measured and SPMD-based water concentrations determined. Results showed that a typical SPMD deployment cage covered with mesh provided the best protection from photodegradation. Samplers which had undergone the highest photodegradation underestimated PAH water concentrations by up to a factor of 5 compared to the most protected SPMDs. This study demonstrates that the potential for photodegradation needs to be addressed when samplers are deployed in water of low turbidity.  相似文献   

9.
Freshwater clams (Corbicula fluminea) and the Huckins et al. (1) semi-permeable membrane sampling device (SPMD) were simultaneously deployed at three sites on the Sacramento and San Joaquin rivers in 1990. Both clams and the SPMDs were analyzed for sequestered pesticides and polychlorinated biphenyls (PCBs) by gas chromatography with electron capture detection (GC/ECD). Polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and non-ortho PCBs were quantified by high resolution mass spectrometry (MS). In general, levels of organochlorine compounds were approximately 1.6 times higher in clams on a wet weight basis than in the SPMDs, and trends in accumulation were similar except where biofouling of the SPMD membranes decreased uptake rates. Comparisons between the normalized, average levels of PCDDs accumulated showed that while octachlorodibenzo-p-dioxin (OCDD) was most prevalent in both clams and SPMDs, much higher levels of 2,3,7,8 TCDD were found in the SPMDs than in the clams; 2,3,7,8 TCDD was 32% of the profile relative to the OCDD level for the SPMDs and <1% of the clam OCDD level. PCB levels showed the clams primarily accumulated hexachlorinated PCBs while the pentachlorinated and tetrachlorinated congeners were higher in the SPMDs. Differences in profiles for homologous series among the PCBs reveal that some congeners, especially those with 2,4,5 substitution, are more likely to bioaccumulate than those with lower chlorination or adjacent unsubstituted sites. GC/MS chromatograms indicate the SPMDs also sequestered several polyaromatic hydrocarbons. GC/ECD chromatograms indicate the presence of several unidentified, early eluting compounds in the SPMDs.  相似文献   

10.
Semipermeable membrane device (SPMD) is a passive sampler that sequesters lipophilic contaminants, mimicking the bioconcentration in the fatty tissue of organisms. This study was designed to assess the use of SPMD and biological tests (Comet assay and Ames test) for air monitoring. For this purpose an occupational environment with expected polycyclic aromatic hydrocarbons (PAHs) contamination (coke plant) was selected for a case study. The SPMDs were deployed in five occupational contaminated sites and in a control site. The SPMD dialysates were chemically analysed and examined for in vitro DNA-damaging activity in human cells (Jurkat) by Comet assay and for mutagenicity with the Ames test (TA98 strain, w/o S9). Total suspended particulates were also collected and analysed (GC–MS). No biological effect of SPMD extract was revealed in the control site. On the other hand, air samples collected with SPMDs within the coke plant showed variable degrees of genotoxic and mutagenic activity. The highest effects were associated with the highest PAH level recovered in the SPMDs extracts and in particulate samples.Results obtained support the sensitivity of biological tests associated to SPMD sampling for evaluating the health risk of potentially contaminated work environments highlighting the usefulness of SPMDs for environmental air quality monitoring.  相似文献   

11.
Luellen DR  Shea D 《Chemosphere》2003,53(7):705-713
Semipermeable membrane devices (SPMDs) are commonly used as a time-integrated measure of aqueous concentrations of persistent hydrophobic chemicals, including PAH, pesticides, dioxins, and PCBs. Another class of persistent hydrophobic chemicals is petroleum biomarker compounds (hopanes and steranes) that are used for hydrocarbon source identification and allocation. In this study three different passive sampling device designs were exposed to a complex hydrocarbon mixture (Alaska North Slope crude) in a laboratory experiment to determine uptake rates of biomarkers into SPMDs. In addition to the standard triolein filled SPMDs, iso-octane filled SPMDs (ISPMDs) and unfilled low-density polyethylene strips (PESDs) were tested. Uptake rates and effective sampling rates were determined for 53 compounds. There was little variation in sampling rates among the individual biomarkers; average values (ld(-1)) for hopanes were 0.43+/-0.07 (PESD), 0.33+/-0.06 (SPMD), and 0.44+/-0.03 (ISPMD) and average sterane sampling rates were 0.57+/-0.04 (PESD), 0.42+/-0.03 (SPMD), and 0.53+/-0.03 (ISPMD). The primary reason for biomarker analysis is for source discrimination of petroleum. Nineteen different diagnostic ratios were measured, and were found to be remarkably well conserved between the oil, water, and all three devices. This indicates that SPMDs, PESDs, and ISPMDs should each be effective for source discrimination studies of petroleum contamination.  相似文献   

12.
Uptake of eight pesticides of different classes (organochlorines, synthetic pyrethroids, dinitroanilines, amides) by semi-permeable membrane devices (SPMDs) was studied in a laboratory continuous-flow system. After 20 days of exposure, membrane concentration factors were in the range of 50 000-120 000 for all the analytes except for the amide herbicides propachlor and alachlor, which were not detected in any of the SPMDs. The kinetic data and mathematical models were used to calculate analyte uptake rate constants, SPMD lipid/water partition coefficients, average sampling rates and concentrations of the pesticides in water. To assess the effects of concentrated pesticides, standard bioassays (Salmonella/histidine reversion assay and bioluminescence inhibition in Vibrio fischeri test) were incorporated in the SPMD technique. To test the method in an environmental situation, SPMDs were deployed in polluted sites in Lithuania. Polynuclear aromatic hydrocarbons were the major pollutants detected in the SPMDs deployed in the field. All the SPMD dialysates were highly toxic in the bioluminescence inhibition test but no mutagenic activity was observed in the Salmonella/histidine reversion assay.  相似文献   

13.
The deposition of atmospheric nitrogen can be enhanced at high altitude sites as a consequence of cloud droplet deposition and orographic enhancement of wet deposition on hills. The degree to which the increased deposition of nitrogen influences foliar nitrogen concentration in a range of upland plant species was studied in a series of field surveys in northern Britain. A range of upland plant species sampled along altitudinal transects at sites of known atmospheric nitrogen deposition showed marked increases in foliar nitrogen concentration with increasing nitrogen deposition and altitude (and hence with decreasing temperature). For Nardus stricta L., Deschampsia flexuosa (L.) Trin., Calluna vulgaris (L.) Hull, Erica cinerea L. and Hylocomium splendens (Hedw.) Br. Eur. on an unpolluted hill, foliar nitrogen increased by 0.07, 0.12, 0.15, 0.08 and 0.04% dry weight respectively for each 1 kg ha(-1) year(-1) increase in nitrogen deposition. Most species showed an approximately linear relationship between foliar nitrogen concentration and altitude but no trend with altitude for foliar phosphorus concentration. This provided evidence that the tissue nutrient status of upland plants reflects nutrient availability rather than the direct effects of climate on growth. However, differences in the relationship between foliar nitrogen concentration and atmospheric nitrogen deposition for N. stricta sampled on hills in contrasting pollution climates show that the possibility of temperature-mediated growth effects on foliar nitrogen concentration should not be ignored. Thus, there is potential to use upland plant species as biomonitors of nitrogen deposition, but the response of different species to nitrogen addition, in combination with climatic effects on growth, must be well characterised.  相似文献   

14.
Interannual, seasonal, daily and altitudinal patterns of tropospheric ozone mixing ratios, as well as ozone phytotoxicity and the relationship with NOx precursors and meteorological variables were monitored in the Central Catalan Pyrenees (Meranges valley and Forest of Guils) over a period of 5 years (2004–2008). Biweekly measurements using Radiello passive samplers were taken along two altitudinal transects comprised of thirteen stations ranging from 1040 to 2300 m a.s.l. Visual symptoms of ozone damage in Bel-W3 tobacco cultivars were evaluated biweekly for the first three years (2004–2006). High ozone mixing ratios, always above forest and vegetation protection AOT40 thresholds, were monitored every year. In the last 14 years, the AOT40 (Apr–Sept.) has increased significantly by 1047 μg m?3 h per year. Annual means of ozone mixing ratios ranged between 38 and 67 ppbv (38 and 74 ppbv during the warm period) at the highest site (2300 m) and increased at a rate of 5.1 ppbv year?1. The ozone mixing ratios were also on average 35–38% greater during the warm period and had a characteristic daily pattern with minimum values in the early morning, a rise during the morning and a decline overnight, that was less marked the higher the altitude. Whereas ozone mixing ratios increased significantly with altitude from 35 ppbv at 1040 m–56 ppbv at 2300 m (on average for 2004–2007 period), NO2 mixing ratios decreased with altitude from 5.5 ppbv at 1040 m–1 ppbv at 2300 m. The analysis of meteorological variables and NOx values suggests that the ozone mainly originated from urban areas and was transported to high-mountain sites, remaining aloft in absence of NO. Ozone damage rates increased with altitude in response to increasing O3 mixing ratios and a possible increase in O3 uptake due to more favorable microclimatic conditions found at higher altitude, which confirms Bel-W3 as a suitable biomonitor for ozone concentrations during summer time. Compared to the valley-bottom site the annual means of ozone mixing ratios are 37% larger in the higher sites. Thus the AOT40 for the forest and vegetation protection threshold is greatly exceeded at higher sites. This could have substantial effects on plant life at high altitudes in the Pyrenees.  相似文献   

15.
To fully utilize semipermeable membrane devices (SPMDs) as passive samplers in air monitoring, data are required to accurately estimate airborne concentrations of environmental contaminants. Limited uptake rate constants (kua) and no SPMD air partitioning coefficient (Ksa) existed for vapor-phase contaminants. This research was conducted to expand the existing body of kinetic data for SPMD air sampling by determining kua and Ksa for a number of airborne contaminants including the chemical classes: polycyclic aromatic hydrocarbons, organochlorine pesticides, brominated diphenyl ethers, phthalate esters, synthetic pyrethroids, and organophosphate/organosulfur pesticides. The kuas were obtained for 48 of 50 chemicals investigated and ranged from 0.03 to 3.07 m3 g?1 d?1. In cases where uptake was approaching equilibrium, Ksas were approximated. Ksa values (no units) were determined or estimated for 48 of the chemicals investigated and ranging from 3.84E+5 to 7.34E+7. This research utilized a test system (United States Patent 6,877,724 B1) which afforded the capability to generate and maintain constant concentrations of vapor-phase chemical mixtures. The test system and experimental design employed gave reproducible results during experimental runs spanning more than two years. This reproducibility was shown by obtaining mean kua values (n = 3) of anthracene and p,p′-DDE at 0.96 and 1.57 m3 g?1 d?1 with relative standard deviations of 8.4% and 8.6% respectively.  相似文献   

16.
Harman C  Tollefsen KE  Bøyum O  Thomas K  Grung M 《Chemosphere》2008,72(10):1510-1516
Passive sampling devices provide a useful contribution to the monitoring of contaminants in the aquatic environment. However, calibration data needed for the calculation of water concentrations from sampler accumulations are restricted to a limited number of compound classes. Thus uptake of a range of alkylated phenols (AP), polycyclic aromatic hydrocarbons (PAH) and carbazoles was determined for semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS) using a flow through exposure system. Sampling rates ranged from 0.02 to 0.26 l d(-1) for POCIS and 0.02 to 13.83 l d(-1) for SPMDs. Observed SPMD uptake was also compared to that predicted by an empirical model including the use of performance reference compounds (PRCs). Predicted sampling rates did not differ by more than a factor of 1.3 from experimental values for PAH, providing further evidence that the PRC approach can be successfully used to determine in situ sampling rates for these compounds. Experimental sampling rates for AP in SPMDs were, however, much lower than predicted. This discrepancy was too large to be explained by small uncertainties in the calibration system or in the calculations. Based on these data we conclude that while hydrophobic AP are accumulated by SPMDs their partitioning cannot be predicted from their logK(ow) using current methods. Due to this lower than expected uptake, sampling rates were only higher in SPMDs than POCIS in the range of logK(ow)>5.0. Simultaneous deployment of both sampler types allows the study of compounds with a broad range of physicochemical properties.  相似文献   

17.
Analyses of triolein-containing semipermeable membrane devices (SPMDs) have sometimes been impeded by interferences caused by impurities endemic to triolein that codialyze with the analytes. Oleic acid and methyl oleate have been the most troublesome of these impurities because of their relatively high concentrations in triolein and because significant residues of both can persist even after size exclusion chromatographic (SEC) fractionation. These residues have also been blamed for false-positive signals during bioindicator testing of SPMD dialysates. To prevent these problems, a simple, cost-effective procedure was developed for purifying triolein destined for use in SPMDs: the bulk triolein is repeatedly (6x) partitioned against methanol. Tests of the procedure show that 14C-oleic acid is completely removed from the triolein. After SEC fractionation, dialysates of standard-size SPMDs made with the purified triolein contain less than 5 microg of methyl oleate as compared to sometimes more than 500 microg for dialysates (also after SEC) of SPMDs made with unpurified triolein. Gas chromatographic analyses with flame ionization and electron capture detection show that the purification treatment also greatly reduces the number and size of peaks caused by unidentified contaminants in the triolein. Microtox basic assay of dialysates of SPMDs shows that those made with the purified triolein have lower acute toxicities than dialysates of SPMDs made with unpurified triolein. Yeast estrogen screen (YES) testing of SPMDs fabricated with unpurified and purified triolein demonstrates that the purification process removes all background estrogenic activity.  相似文献   

18.
The gas-particle partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was examined (i) by re-interpreting results from controlled field experiments and (ii) in diurnal samples taken in the New Jersey (NJ), New York (NY) City region. In the controlled field experiments, aerosol-laden filters were exposed to elevated concentrations of PCDD/Fs. Gas-particle partitioning coefficients, Kp's, were significantly correlated with octanol–air partitioning coefficients, Koa's. The regression of all individual datapoints resulted in the following best fit (r2=0.74, n=87): log Kp,meas=1.00(±0.13) log(10−12fomKoa/ρoct)−0.15(±0.48). We interpret this as showing that the ability of organic matter (OM) to absorb PCDD/Fs is generally well described by the octanol–air partitioning model (fomKoa). At the NJ land-based sites, samples were taken and analyzed for organic carbon (OC) and elemental carbon (EC), gaseous and particulate PCDD/Fs. Kp's were significantly correlated with the fomKoa approach. Adsorption to the filter and possibly to black carbon (BC), which was estimated based on EC measurements, could have contributed to the observed Kp values. Gas-particle predictions based on BC adsorption and OM absorption, with Kp=fomKoa/(1012ρoct)+fBCKBC–air/(1012ρBC) resulted in Kp predictions that were close to measured values. Adsorption to the filter might have been the major reason for elevated Kp's: The one NJ site with highest Kp's was most prone to the filter adsorption sampling artefact because of relatively low sampling volumes and concentrations of total suspended particulates. In addition, while adsorption to BC would result in better prediction of Kp values, no influence of fBC or fBC/fom ratios was seen, suggesting that it was of lesser importance in our sample set.  相似文献   

19.
Ellis SG  Booij K  Kaputa M 《Chemosphere》2008,72(8):1112-1117
Semipermeable membrane devices (SPMDs) spiked with the performance reference compound PCB29 were deployed 6.1 m above the sediments of Lake Chelan, Washington, for a period of 27 d, to estimate the dissolved concentrations of 4,4'-DDT, 4,4'-DDE, and 4,4'-DDD. Water concentrations were estimated using methods proposed in 2002 and newer equations published in 2006 to determine how the application of the newer equations affects historical SPMD data that used the older method. The estimated concentrations of DDD, DDE, and DDD calculated using the older method were 1.5-2.9 times higher than the newer method. SPMD estimates from both methods were also compared to dissolved and particulate DDT concentrations measured directly by processing large volumes of water through a large-volume solid-phase extraction device (Infiltrex 300). SPMD estimates of DDD+DDE+DDT (SigmaDDT) using the older and newer methods were lower than Infiltrex concentrations by factors of 1.1 and 2.3, respectively. All measurements of DDT were below the Washington State water quality standards for the protection of human health (0.59 ng l(-1)) and aquatic life (1.0 ng l(-1)).  相似文献   

20.
Semivolatile organic compounds (SVOCs) are a major class of indoor pollutants. Understanding SVOC partitioning between the gas phase and settled dust is important for characterizing the fate of these species indoors and the pathways by which humans are exposed to them. Such knowledge also helps in crafting measurement programs for epidemiological studies designed to probe potential associations between exposure to these compounds and adverse health effects. In this paper, we analyze published data from nineteen studies that cumulatively report measurements of dustborne and airborne SVOCs in more than a thousand buildings, mostly residences, in seven countries. In aggregate, measured median data are reported in these studies for 66 different SVOCs whose octanol-air partition coefficients (Koa) span more than five orders of magnitude. We use these data to test a simple equilibrium model for estimating the partitioning of an SVOC between the gas phase and settled dust indoors. The results demonstrate, in central tendency, that a compound’s octanol-air partition coefficient is a strong predictor of its abundance in settled dust relative to its gas phase concentration. Using median measured results for each SVOC in each study, dustborne mass fractions predicted using Koa and gas-phase concentrations correlate reasonably well with measured dustborne mass fractions (R2 = 0.76). Combined with theoretical understanding of SVOC partitioning kinetics, the empirical evidence also suggests that for SVOCs with high Koa values, the mass fraction in settled dust may not have sufficient time to equilibrate with the gas phase concentration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号