首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study the occurrence of ten organophosphate triesters in indoor air at 29 different locations was investigated. They were detected at all locations and a total of ten compounds were identified. The predominant compounds were the chlorinated compounds tris(chloroisopropyl) phosphate and tris(2-chloroethyl) phosphate with a concentration around 2 microg m(-3) in some indoor environments. A rough estimation gives at hand a daily inhalation of around 10 microg for each of these two compounds.  相似文献   

2.
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).  相似文献   

3.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

4.
The behaviour of the three organophosphate esters tributyl phosphate (TBP), tris(2-chloroethyl)phosphate (TCEP) and tris(2-butoxyethyl)phosphate (TBEP) during infiltration of river water to ground water has been investigated. The monitoring site is the Oder River and the adjacent Oderbruch aquifer. From March 2000 to July 2001, 76 ground water samples from monitoring wells located close to the Oder River and nine river water samples were collected. Additionally, influent and effluent samples from local waste water treatment plants, one sample of rain water and samples of roof runoff were collected. All samples were analysed by solid-phase-extraction followed by gas chromatography/mass spectrometry. TBP, TCEP and TBEP were detected at mean values of 622 ng l(-1), 352 ng l(-1), and 2955 ng l(-1), respectively in municipal waste water effluents. This points to a major input of these compounds into the Oder River by municipal waste water discharge. The concentrations of TBP and TBEP decreased downstream the Oder River possibly due to aerobic degradation. TBP, TCEP and TBEP were detected in ground water influenced predominantly by bank-filtered water. This demonstrates a transport of organic compounds by river water infiltration to ground water. TBP, TCEP and TBEP were also detected in rain water precipitation, roof runoff and ground water predominantly influenced by rain water infiltration. This hints to an input of these compounds to ground water by dry and wet deposition after atmospheric transport. Organophosphate esters were also detected in parts of the aquifer at 21 m depth. This demonstrates low anaerobic degradation rates of TBP, TCEP and TBEP.  相似文献   

5.
An extensive study has been conducted on the prevalence of organophosphorous flame retardants/plasticizers and phthalate ester plasticizers in indoor air. The targeted substances were measured in 45 multi-storey apartment buildings in Stockholm, Sweden. The apartment buildings were classified as high or low risk with regard to the reporting of sick building symptoms (SBS) within the project Healthy Sustainable Houses in Stockholm (3H). Air samples were taken from two to four apartments per building (in total 169 apartments) to facilitate comparison within and between buildings. Association with building characteristics has been examined as well as association with specific sources by combining chemical analysis and exploratory uni- and multivariate data analysis. The study contributes to the overall perspective of levels of organophosphate and phthalate ester in indoor air enabling comparison with other studies. The results indicated little or no difference in the concentrations of the target substances between the two risk classifications of the buildings. The differences between the apartments sampled within (intra) buildings were greater than the differences between (inter) buildings. The concentrations measured in air ranged up to 1200 ng m(-3) for organophosphate esters and up to 11?000 ng m(-3) for phthalate esters. Results in terms of sources were discerned e.g. PVC flooring is a major source of benzylbutyl phthalate in indoor air.  相似文献   

6.
Total suspended particulate (TSP), PM(2.5) and BTEX were collected in nine offices in the province of Antwerp, Belgium. Both indoor and outdoor aerosol samples were analysed for their weight, elemental composition, and water-soluble fraction. Indoor TSP and PM(2.5) concentrations ranged from 7-31 microg m(-3) and 5-28 microg m(-3), with an average of 18 and 11 microg m(-3), respectively. Of all the elements analysed in indoor TSP, more than 95% was represented by Al, Si, K, Ca, Fe, Cl and S, accounting for 12% of the TSP by mass. The other elements showed significant enrichment relative to the earth's crust. The water-soluble ionic fraction accounted for almost 30% of the sampled indoor TSP by weight, and was enriched by anthropogenic activities. It was shown that the indoor PM levels varied among the offices, depending on the ventilation pattern, location, and occupation density of the office. Indoor BTEX levels ranged together from 5-47 microg m(-3) and were considerably higher than the corresponding outdoor levels. It was observed that some recently constructed and renovated buildings were clearly burdened with elevated levels for toluene, ethyl benzene, and xylenes, while outdoor air was found to be the main source for BTEX levels at the 'older' offices.  相似文献   

7.
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.  相似文献   

8.
Total suspended particulates (TSP) were collected with a high volume sampler from the indoor work environment of 23 industries in Al-Rusayl Industrial Estate in Muscat, Oman. The values measured ranged from 39 microg m(-3) to 1033 microg m(-3). TSP in the ambient air of the area was found to have an average value of 1802 microg m(-3). TSP were analyzed for Pb, Cu, Ni, Zn and Cr. Compared to other metals, Pb emission was high with values ranging from 3 to 15 109 ng m(-3) with the mean value being 1 293 ng m(-3); Cu concentration varied from 3 to 2600 ng m(-3) with a mean value of 131 ng m(-3); Ni concentration ranged from 6 to 46 ng m(-3) with a mean value of 17 ng m(-3); Cr concentration ranged from 1 to 133 ng m(-3) with a mean value of 23 ng m(-3) while that of Zn varied from 0.01 to 1 978 ng m(-3) with the mean value being 464 ng m(-3). The concentrations of Pb, Ni, Cu, Cr, and Zn in the ambient air were also measured and found to have the following values: 122, 18, 16, 5 and 0.01 ng m(-3), respectively. These values indicate that the industries in the area do not contribute significantly to heavy metal air pollution.  相似文献   

9.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

10.
Occurrence and distribution of chlorinated and non-chlorinated organophosphates in 72 groundwater samples from Germany under different recharge/infiltration conditions were investigated. Tris(2-chloro-1-methylethyl) phosphate (TCPP) and tris(2-chloroethyl) phosphate (TCEP) were the most frequently detected organophosphates in groundwater samples. Highest individual organophosphate concentrations (>0.1 μg L(-1)) were determined in groundwater polluted by infiltrating leachate and groundwater recharged via riverbank filtration of organophosphate-loaded recipients. In samples from springs and deep groundwater monitoring wells that are not affected by surface waters, organophosphate concentrations were mostly below the limit of detection. The occurrence (3-9 ng L(-1)) of TCPP and TCEP in samples from aquifers with groundwater ages between 20 and 45 years indicates the persistence of both compounds within the aquifer. At urban sites organophosphate-loaded precipitation, surface runoff, and leakage of wastewater influenced groundwater quality. For rural sites, where groundwater recharge is only influenced by precipitation, organophosphates were very rarely detectable in groundwater.  相似文献   

11.
This study describes the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils, among ground personnel within the aviation industry. The OPs tri-n-butyl phosphate (TnBP), dibutyl phenyl phosphate (DBPP), triphenyl phosphate (TPP) and tricresyl phosphate (TCP) have been emphasized due to their use in such oils. Oil aerosol/vapor and total volatile organic compounds (tVOCs) in air were also determined. In total, 228 and 182 OPs and oil aerosol/vapor samples from technician and loader work tasks during work on 42 and 21 aircrafts, respectively, were collected in pairs. In general, the measured exposure levels were below the limit of quantification (LOQ) for 84%/98% (oil aerosol) and 82%/90% (TCP) of the samples collected during technician/loader work tasks. The air concentration ranges for all samples related to technician work were 相似文献   

12.
Determination of organophosphorus fire retardants and plasticizers at trace levels in wastewater is described. In this work, microwave assisted extraction (MAE) and solid-phase microextraction (SPME) are used for sample preparation to extract and preconcentrate the analytes, followed by analysis by gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) for phosphorus-specific detection. Gas chromatography coupled to time of flight mass spectrometry (GC-TOF-MS) was used to confirm the organphosphorus fire retardants in wastewater. The detection limits of organophosphorus fire retardants (OPFRs) were 29 ng L(-1) for tri-n-butyl phosphate (TnBP), 45 ng for L(-1) for tris(2-butoxyethyl)phosphate (TBEP), and 50 ng L(-1) for tris(2-ethylhexyl)phosphate (TEHP). Optimized extraction conditions were performed at 65 degrees C for 30 min and with 10% NaCl. Application of MAE during the sample preparation prior to the SPME allowed the detection of tris(2-ethylhexyl) phosphate, which has been difficult to determine in previous work. Application of the method to wastewater samples resulted in detecting 3.1 microg L(-1) P from TnBP, 5.0 microg L(-1) P from TBEP, and 4.0 microg L(-1) P from TEHP. The presence of these compounds were also confirmed by SPME-GC-TOF-MS.  相似文献   

13.
Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max 相似文献   

14.
The thermal degradation products of polyurethanes (PURs) and exposure to isocyanates were studied by stationary and personal measurements in five different occupational environments. Isocyanates were collected on glass fibre filters impregnated with 1-(2-methoxyphenyl)piperazine (2MP) and in impingers containing n-dibutylamine (DBA) in toluene. connected to a glass fibre postfilter. The derivatives formed were analysed by liquid chromatography: 2MP derivatives with UV and electrochemical detection and DBA derivatives with mass spectrometric detection. The release of aldehydes and other volatile organic compounds into the air was also studied. In a comparison of the two sampling methods, the 2MP method yielded about 20% lower concentrations for 4,4'-methylenediphenyl diisocyanate (MDI) than did the DBA method. In car repair shops, the median concentration of diisocyanates (given as NCO groups) in the breathing zone was 1.1 microg NCO m(-3) during grinding and 0.3 microg NCO m(-3) during welding, with highest concentrations of 1.7 and 16 pg NCO m(-3), respectively. High concentrations of MDI, up to 25 and 19 microg NCO m(-3), respectively, were also measured in the breathing zone during welding of district heating pipes and turning of a PUR-coated metal cylinder. During installation of PUR-coated floor covering, small amounts of aliphatic diisocyanates were detected in the air. A small-molecular monoisocyanate, methyl isocyanate, and isocyanic acid were detected only during welding and turning operations. The diisocyanate concentrations were in general higher near the emission source than in the workers' breathing zone. A sampling strategy to evaluate the risk of exposure to isocyanates is presented.  相似文献   

15.
Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, alpha-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 microg m(-3)), they are all below 0.5 microg m(-3). Calibration curves are linear up to 10 micromol m(-3) for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.  相似文献   

16.
Food cooking using liquefied petroleum gas (LPG) has received considerable attention in recent years since it is an important source of particulate air pollution in indoor environments for non-smokers. Exposure to organic compounds such as polycyclic aromatic hydrocarbons (PAHs) contained in particles is of particular health concern since some of these compounds are suspected carcinogens. It is therefore necessary to chemically characterize the airborne particles emitted from gas cooking to assess their possible health impacts. In this work, the levels of fine particulate matter (PM(2.5)) and 16 priority PAHs were determined in three different ethnic commercial kitchens, specifically Chinese, Malay and Indian food stalls, where distinctive cooking methods were employed. The mass concentrations of PM(2.5) and PAHs, and the fraction of PAHs in PM(2.5) were the highest at the Malay stall (245.3 microg m(-3), 609.0 ng m(-3), and 0.25%, respectively), followed by the Chinese stall (201.6 microg m(-3), 141.0 ng m(-3), and 0.07%), and the Indian stall (186.9 microg m(-3), 37.9 ng m(-3), and 0.02%). This difference in the levels of particulate pollution among the three stalls may be attributed to the different cooking methods employed at the food stalls, the amount of food cooked, and the cooking time, although the most sensitive parameter appears to be the predominant cooking method used. Frying processes, especially deep-frying, produce more air pollutants, possibly due to the high oil temperatures used in such operations. Furthermore, it is found that frying, be it deep-frying at the Malay stall or stir-frying at the Chinese stall, gave rise to an abundance of higher molecular weight PAHs such as benzo[b]fluoranthene, indeno[1,2,3-cd]pyrene and benzo[g,h,i]perylene whereas low-temperature cooking, such as simmering at the Indian stall, has a higher concentration of lower molecular weight PAHs. In addition, the correlation matrices and diagnostic ratios of PAHs were calculated to determine the markers of gas cooking. To evaluate the potential health threat due to inhalation exposure from the indoor particulate pollution, excess lifetime cancer risk (ELCR) was also calculated for an exposed individual. The findings suggest that cooking fumes in the three commercial kitchens pose adverse health effects.  相似文献   

17.
While it is known that the ingestion of indoor dust contributes substantially to human exposure to the recently restricted polybrominated diphenyl ethers (PBDEs), the situation for one class of potential replacements, i.e. organophosphate esters (OPEs), used in a variety of applications including as flame retardants has yet to be fully characterised. In this study, surface dust from twelve different cars from various locations throughout Germany were analysed for eight OPEs, decabromodiphenyl ethane (DBDPE), and eight PBDEs. In five cars, tris-(1,3-dichloro-2-propyl) phosphate (TDCPP) was the dominant compound with concentrations up to 620 μg g(-1) dust. High concentrations of tri-cresyl phosphate (TCP) (up to 150 μg g(-1)) were also detected in two samples of car dust. Dust from ten offices in the same building in Ludwigsburg, Germany was also analysed. In these samples, tri (2-butoxyethyl) phosphate (TBEP) predominated with an average concentration of 7.0 μg g(-1) dust, followed by tris (1-chloro-2-propyl) phosphate (TCPP) at 3.0 μg g(-1) and triphenyl phosphate (TPhP) at 2.5 μg g(-1) dust. Although caution must be exercised given the relatively small database reported here; this study provides evidence that cars and offices from Germany are significantly more contaminated with OPEs than PBDEs. Average concentrations of ΣOPEs were ten times higher in car than in office dust. This is the first study to provide data on a wide range of OPE concentrations in German indoor dust samples.  相似文献   

18.
Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people working in the mall, should be of health effect concern.  相似文献   

19.
The aims were to assess the impact of a total smoking ban on the level of airborne contaminants and the urinary cotinine levels in the employees in bars and restaurants. In a follow up design, 13 bars and restaurants were visited before and after the implementation of a smoking ban. Ninety-three employees in the establishments were initially included into the study. The arithmetic mean concentration of nicotine and total dust declined from 28.3 microg m(-3) (range, 0.4-88.0) and 262 microg m(-3) (range, 52-662), respectively, to 0.6 microg m(-3) (range, not detected-3.7) and 77 microg m(-3) (range, not detected-261) after the smoking ban. The Pearson correlation coefficient between airborne nicotine and total dust was 0.86 (p < 0.001; n = 48). The post-shift geometric mean urinary cotinine concentration declined from 9.5 microg g(-1) creatinine (cr) (95% CI 6.5-13.7) to 1.4 microg g(-1) cr (95% CI 0.8-2.5) after the ban (p < 0.001) in 25 non-snuffing non-smokers. A reduction from 1444 microg g(-1) cr (95% CI 957-2180) to 688 microg g(-1) cr (95% CI 324-1458) was found (p < 0.05) in 29 non-snuffing smokers. The urinary cotinine levels increased from 11.7 microg g(-1) cr (95% CI 7.0-19.6) post-shift to 21.9 microg g(-1) cr (95% CI 13.3-36.3) (p < 0.01) in the next morning in 24 non-snuffing non-smokers before the smoking ban. A substantial reduction of airborne nicotine and total dust was observed after the introduction of a smoking ban in bars and restaurants. The urinary cotinine levels were reduced in non-smokers. The decline found in smokers may suggest a reduction in the amount of smoking after intervention. In non-smokers cotinine concentrations were higher based on urine sampled the morning after a shift than based on urine sampled immediately post-shift.  相似文献   

20.
Quaternary Ammonium Compounds (QACs) are widely found in disinfectants used in hospitals. Benzalkonium chloride (BAC) and didecyldimethylammonium chloride (DDAC) predominate in the disinfecting formulations. These compounds are strong irritants and can play a role in the induction of Occupational Asthma among the professionals of health and cleaning. In order to evaluate the potential health effect of these quaternary ammonium compounds to hospital employers, the development of an analytical method for their quantification in indoor air was developed. DDAC aerosols are trapped by adsorption on XAD-2 resin SKC tube. The air in hospital buildings was sampled using a constant debit Gillian pump at a flow of 1.0 l/min (+/-5%). Ion Chromatography (IC) was chosen for the analysis of DDAC especially for its high sensitivity and specificity. The Limit of Detection (LOD) by IC for DDAC is 0.56 mug/ml. Therefore the LOD of atmospheric DDAC is 28 microg/m(3) with an air volume of 100 l and a desorption volume of 5 ml. All DDAC air samples were lower than the LOD of the analytical method by IC. Under the standard conditions of use of the disinfecting solutions (Surfanios, Ampholysine Plus and Amphospray 41), the insignificant volatility of DDAC would not seem to be able to contaminate the indoor hospital atmosphere during the disinfection process. However, the DDAC can contaminate working atmospheres if it is put in suspension by aerosolisation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号