1.
The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 μm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.  相似文献   

2.
预处理对短流程超滤工艺不可逆膜污染影响的中试试验   总被引:2,自引:1,他引:1  
以东江水为处理对象,进行直接超滤、微絮凝-超滤和絮凝/活性炭-超滤中试研究,探讨预处理对短流程超滤工艺不可逆膜污染的影响.利用扫描电镜形貌观察、三维荧光光谱(EEM)和高效排阻色谱法等手段对不可逆膜污染物进行表征分析,比较预处理对不可逆膜污染物含量和组分的影响,阐述预处理对不可逆膜污染影响的机制.结果表明,在10 L·(m~2·h)~(-1)低通量运行下,微絮凝预处理使不可逆膜污染增长速率从直接超滤的0.32 k Pa·d~(-1)下降到0.16 k Pa·d~(-1),絮凝/活性炭预处理后超滤工艺几乎零污染运行,且当絮凝/活性炭-超滤运行通量增加至17 L·(m~2·h)~(-1)时,仍没有观察到明显的不可逆膜污染增长.东江水中不可逆膜污染的主要组分是蛋白质类和富里酸等腐殖质类物质.微絮凝通过改变膜表面滤饼层的结构(厚度和密实性),提高物理清洗效率,减轻不可逆膜污染的积累;絮凝/活性炭预处理提高对不可逆膜污染物的去除效果,减轻膜污染负荷,控制不可逆膜污染.因此,采用絮凝和絮凝/活性炭预处理工艺,均可有效降低短流程超滤工艺不可逆膜污染积累.  相似文献   

3.
混凝对微滤膜处理含磷废水的影响   总被引:6,自引:1,他引:5  
张进  孙宇新  董强  刘杏芹  孟广耀 《环境科学》2006,27(6):1098-1102
采用直接微滤和混凝-微滤2种工艺对高浓度含磷废水进行了处理.结果表明,混凝预处理减轻了膜孔堵塞污染,改善了膜表面沉积层的存在形态,提高了膜的渗透通量;与原水直接微滤相比,混凝-微滤组合工艺改进了出水水质,磷酸盐的去除率从11.0%提高到99.7%,出水满足国家一级排放标准;经过相同方法清洗后,混凝-微滤工艺的膜通量能恢复到初始通量的90%以上,而直接微滤工艺的膜通量只能恢复到初始通量的72%.  相似文献   

4.
操作条件对超滤膜运行经济稳定性能的影响   总被引:2,自引:1,他引:1  
采用正交实验的方法对棕榈油生产废水二级处理出水的超滤工艺条件进行考察和优化,并用膜通量衰减系数、平均跨膜压差及产水量各自加权相加所得综合指标来表征不同超滤操作条件下膜运行的经济稳定性能。正交试验结果表明,减小膜表面流速和产水率,提高处理废水温度均有利于系统经济稳定地运行;各运行参数对综合指标影响的大小顺序为:膜表面平均流速>产水率>温度;在保证出水质量的前提下,最佳组合操作条件为膜表面平均流速0.7m/s,产水率80%,废水温度30℃。  相似文献   

5.
主要通过浸没式平板膜生物反应器的膜污染阻力分布和膜表面的污染特性来分析波纹微通道湍流促进器减缓浸没式平板膜生物反应器的膜污染效果.结果表明,波纹微通道湍流促进器有效地降低了总阻力Rt,降低率达到68.01%,其中的Rrf、Rc和Rp+Ra分别降低54.20%、87.98%和84.00%;滤饼层厚度、有机和无机污染成分都减少,且污染层更易去除.综合膜污染阻力分布和膜表面污染物表征结果从扰流作用强化机理、逆扩散机理、絮凝机理和微孔强化过滤机理四个方面分析了波纹微通道湍流促进器减缓浸没式平板膜生物反应器膜污染的效果.  相似文献   

6.
王旭东  张银辉  王磊  张慧慧  夏四清 《环境科学》2014,35(11):4176-4184
为进一步研究多种蛋白质体系超滤过程的膜污染机制,采用切割相对分子质量为50×103的聚醚砜(polyethersulfone,PES)超滤膜,对溶菌酶(lysozyme,LYS)、牛血清蛋白(bovine serum albumin,BSA)、LYS+BSA等3种不同蛋白质溶液的超滤过程进行了研究.运用接触角仪、场发射扫描电镜(field emission scanning electron microscope,FESEM)、原子力显微镜(atomic force microscope,AFM)测定了不同污染阶段膜特征参数的变化.结果表明,超滤膜通量变化明显呈现3个阶段:初期(约0~5min)衰减迅速、中期(约5~60 min)衰减缓慢、后期(约60~120 min)趋于稳定;整个超滤过程中,LYS污染膜的通量衰减幅度最大,LYS+BSA次之,BSA最小.膜特征参数变化表明:LYS对膜的初期污染主要以膜孔窄化为主,中期污染由膜孔堵塞和膜孔窄化共同控制;BSA初期膜污染以膜孔堵塞为主,中期污染以膜孔窄化为主;滤饼层过滤是BSA、LYS后期膜污染的主要机制.LYS+BSA二元混合溶液中的LYS对膜污染的产生起主导作用.  相似文献   

7.
The membrane fouling caused by extracellular organic matter (EOM) and algal cells and organic matter removal of two typical cyanobacteria (M. aeruginosa and Pseudoanabaena sp.) during ultrafiltration (UF) process were studied in this work. The results showed that EOM had a broad molecular weight (Mw) distribution and the irreversible membrane fouling was basically caused by EOM. Moreover, humic acid and microbial metabolites were major components of EOM of two typical cyanobacteria. Since EOM could fill the voids of cake layers formed by the algal cells, EOM and algal cells played synergistic roles in membrane fouling. Fourier transform infrared spectroscopy analysis indicated that the CH2 and CH3 chemical bonds may play an important role in membrane fouling caused by EOM. Interestingly, the cake layer formed by the algal cells could trap the organic matter produced by algae and alleviate some irreversible membrane fouling. The results also showed that although the cake layer formed by the algal cells cause severe permeate flux decline, it could play a double interception role with UF membrane and increase organic matter removal efficiency. Therefore, when using UF to treat algae-laden water, the balance of membrane fouling and organic matter removal should be considered to meet the needs of practical applications.  相似文献   

8.
大庆油田水务公司西水源水厂以地下水作为主要水源,采用臭氧/活性炭+超滤膜(UF)处理工艺;自2014年投产至2019年底已经运行5年,水厂出水浊度、有机物(CODMn)和菌落总数等水质指标均稳定达标,但超滤膜污染导致膜性能变化。为了探究5年运行过程中超滤膜处理性能演变情况,对膜出水水质、膜通量、跨膜压差和膜污染层等进行分析。结果表明:超滤膜对浊度和微生物的去除率保持在90%以上,对CODMn平均去除率维持在9%。运行5年过程中,超滤膜的比通量每年下降2.1%~4.6%,恢复性化学清洗(CIP)对超滤膜的通量与比通量恢复率分别维持在73%~91%和85%~92%。污染层分析结果表明,超滤膜的有机污染物主要是腐植酸和蛋白质等;无机污染物包括锰、铁、硅、钙和铝等。高价金属元素与有机物形成络合污染物,在污染层中起到支配作用;另外,钙和硅的无机盐垢也不可忽视。  相似文献   

9.
分别采用孔径为0.8,0.2μm微滤膜和50nm超滤膜过滤草浆黑液,探讨了操作条件对无机膜渗透通量的影响。结果表明,选用0 2或0.8μm孔径的膜,有利于渗透通量的提高并保证截留效果。操作压力在0.25~0.35MPa之间,错流速度不小于5.0m s,温度为60℃时,可以获得较高的渗透通量。黑液本身的性质,如浓度、COD值等,也会对渗透通量产生较大的影响。   相似文献   

10.
以聚硫酸铁(PFS)为混凝剂,微砂为载体颗粒,系统考察了采用加载絮凝-超滤联用工艺净化含高岭土、腐植酸和锑[Sb(Ⅲ)]的模拟原水过程中,不同PFS和微砂投加量条件下加载絮体形态特性以及其对超滤膜通量衰减、膜污染可逆性和宏观出水水质等的影响,并分析了膜污染机理.结果表明,PFS投加量对絮体形态及膜滤效能和膜污染影响显著,且投加量过少或过多均会产生不利影响,以30mg/L为宜;与不投加微砂的工况相比,加入微砂更易于形成大而结构较为松散的絮体,可有效削弱不可逆膜污染,并获得较为稳定的超滤出水水质;超滤末端膜比通量与絮体平均粒径呈良好的正相关性(R2=0.8774),但因加载絮凝体系中引起分形维数变大的不同类型颗粒(包括小粒径范围絮体和未被加载絮体捕获的微砂)对超滤净水过程产生的影响各异,致使膜通量与分形维数的负相关性较差(R2=0.5760).  相似文献   

11.
In this study,direct contact membrane distillation(DCMD)was used for treating fermentation wastewater with high organic concentrations.DCMD performance characteristics including permeate flux,permeate water quality as well as membrane fouling were investigated systematically.Experimental results showed that,after 12 hr DCMD,the feed wastewater was concentrated by about a factor of 3.7 on a volumetric basis,with the permeate flux decreasing from the initial 8.7 L/m~2/hr to the final 4.3 L/m~2/hr due to membrane fouling;the protein concentration in the feed wastewater was increased by about 3.5 times and achieved a value of 6178 mg/L,which is suitable for reutilization.Although COD and TOC in permeate water increased continuously due to the transfer of volatile components from wastewater,organic rejection of over 95%was achieved in wastewater.GC–MS results suggested that the fermentation wastewater contained 128kinds of organics,in which 14 organics dominated.After 12 hr DCMD,not only volatile organics including trimethyl pyrazine,2-acetyl pyrrole,phenethyl alcohol and phenylacetic acid,but also non-volatile dibutyl phthalate was detected in permeate water due to membrane wetting.FT-IR and SEM–EDS results indicated that the deposits formed on the membrane inner surface mainly consisted of Ca,Mg,and amine,carboxylic acid and aromatic groups.The fouled membrane could be recovered,as most of the deposits could be removed using a HCl/Na OH chemical cleaning method.  相似文献   

12.
Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV254 removals by the UF with in-line coagulation at pH 7 were increased from 28% to 53% and 40% to 78% in comparison with direct UF treatment respectively. At the same time, the analysis of high performance liquid chromatography showed that UF with coagulation had significant improvement of removal of humic acid with molecular weights less than 6000 Da in particular. Compared to direct UF, the in-line coagulation UF also kept more constant permeate flux and very slight increase oftransmembrane pressure during a filtration circle. Two typical membrane fouling models were used by inducing two coefficients Kc and Kp corresponding to cake filtration model and pore narrowing model respectively. It was found that membrane fouling by pore-narrowing effect was effectively alleviated and that by cake-filtration was much decreased by in-line coagulation. Under the condition of coagulation prior to ultrafiltration at pH 7, the cake layer formed on the membrane surface became thicker, but the membrane filtration resistance was lower than that at pH 5 with the extension of operation time.  相似文献   

13.
为提高超滤膜系统对污水处理厂二级出水中有机物和TN的去除效果,并降低超滤膜污染速率,改善超滤膜性能,分析了沸石粉、硅藻土2种预涂膜工艺在超滤膜系统中的应用效果. 结果表明:沸石粉/超滤工艺对超滤膜系统的膜通量恢复良好,反冲洗后能恢复到原来的膜通量;而硅藻土/超滤工艺中膜通量较初期下降0.01 L/(m2·h),对照组下降0.04 L/(m2·h). 沸石粉/超滤工艺对污水处理厂二级出水中CODCr、UV254和TN的去除率分别为17.5%、13.5%和11.7%,相比对照组均有较大程度提高. 通过电镜扫描分析发现,沸石粉能够在超滤膜表面有效形成一层保护膜,降低有机物在膜表面的沉积,保障膜系统的高效率及长期稳定运行. 通过比较各实际运行工况效果并进行筛选,确定沸石粉为预涂膜工艺的最佳材料.   相似文献   

14.
Municipal sewage from an oxidation ditch was treated for reuse by nanofiltration (NF) in this study. The NF performance was optimized, and its fouling characteristics after different operational durations (i.e., 48 and 169 hr) were analyzed to investigate the applicability of nanofiltration for water reuse. The optimum performance was achieved when transmembrane pressure = 12 bar, pH = 4 and flow rate = 8 L/min using a GE membrane. The permeate water quality could satisfy the requirements of water reclamation for different uses and local standards for water reuse in Beijing. Flux decline in the fouling experiments could be divided into a rapid flux decline and a quasi-steady state. The boundary flux theory was used to predict the evolution of permeate flux. The expected operational duration based on the 169-hr experiment was 392.6 hr which is 175% longer than that of the 48-hr one. High molecular weight (MW) protein-like substances were suggested to be the dominant foulants after an extended period based on the MW distribution and the fluorescence characteristics. The analyses of infrared spectra and extracellular polymeric substances revealed that the roles of both humic- and polysaccharide-like substances were diminished, while that of protein-like substances were strengthened in the contribution of membrane fouling with time prolonged. Inorganic salts were found to have marginally influence on membrane fouling. Additionally, alkali washing was more efficient at removing organic foulants in the long term, and a combination of water flushing and alkali washing was appropriate for NF fouling control in municipal sewage treatment.  相似文献   

15.
PES/PAN膜在MBR中膜污染机理及抗污染性能   总被引:2,自引:2,他引:0  
采用液-固相转化法,以聚醚砜(PES)、氯化锂(LiCl)、聚乙烯吡咯烷酮(PVP)和N,N-二甲基乙酰胺(DMAc)为原料制备PES膜,并在体系中添加聚丙烯腈(PAN)制备PES/PAN膜。在操作温度25℃,操作压力90KPa条件下制得的PES/PAN膜、自制PES膜和商品PES超滤膜分别为222L/(m·2h)左右,130L/(m·2h)左右,82L/(m·2h)左右。通过膜生物反应器中膜阻力的测定,表明膜污染主要由沉积层引起的,另一方面长期运行膜孔堵塞也是阻力增大的原因。在MBR中运行时,PES/PAN膜、自制PES膜和商品PES超滤膜膜通量的衰减速率分别为0.2559L/(m·2h·min)、0.3366L/(m·2h·min)、0.3539L/(m·2h·min),PES/PAN膜通量衰减最慢;在MBR中运行15d后,经过化学清洗,PES/PAN膜、自制PES膜和商品PES超滤膜纯水通量恢复率分别为83.75%、63.58%、61.32%,PES/PAN膜通量恢复率最大,抗污染性优于PES膜。  相似文献   

16.
采用经砂滤处理后的滆湖水作为原料液,氯化钠溶液作为汲取液,在不同影响因素条件下进行正渗透试验,并对试验后的膜片进行清洗,探究膜污染的可逆性.结果表明:提高汲取液浓度、运行温度及膜面流速均可有效增加膜通量;正渗透对滆湖水体中的溶解性微生物代谢产物、类色氨酸、类富里酸和腐殖酸四种主要DOM成分均有较好的去除效果,DOC、UV254截留率均在96%以上;短期运行通过水力清洗几乎可以完全恢复膜通量,而长期运行通过超声清洗可以基本恢复全部膜通量,通过分析膜清洗液可知造成膜污染的主要物质为类色氨酸类和类富里酸类物质.  相似文献   

17.
Fouling behavior along the length of membrane module was systematically investigated by performing simple modeling and lab-scale experiments of forward osmosis (FO) membrane process. The flux distribution model developed in this study showed a good agreement with experimental results, validating the robustness of the model. This model demonstrated, as expected, that the permeate flux decreased along the membrane channel due to decreasing osmotic pressure differential across the FO membrane. A series of fouling experiments were conducted under the draw and feed solutions at various recoveries simulated by the model. The simulated fouling experiments revealed that higher organic (alginate) fouling and thus more flux decline were observed at the last section of a membrane channel, as foulants in feed solution became more concentrated. Furthermore, the water flux in FO process declined more severely as the recovery increased due to more foulants transported to membrane surface with elevated solute concentrations at higher recovery, which created favorable solution environments for organic adsorption. The fouling reversibility also decreased at the last section of the membrane channel, suggesting that fouling distribution on FO membrane along the module should be carefully examined to improve overall cleaning efficiency. Lastly, it was found that such fouling distribution observed with co-current flow operation became less pronounced in counter- current flow operation of FO membrane process.  相似文献   

18.
腐殖酸溶液对超滤膜污染的原因研究   总被引:2,自引:0,他引:2  
针对腐殖酸溶液对超滤膜污染的原因,对超滤膜在过滤腐殖酸溶液时受到污染的变化进行了探讨,通过测试的数据比较了待测腐殖酸溶液与膜通量的关系,同时对腐殖酸溶液和添加钙离子后,对超滤膜污染的影响状况,同时还对超滤膜在过滤过程中的UV254变化规律进行了探讨。结果表明,不同质量浓度的腐殖酸溶液,它们对膜通量的影响比较显著,在相同的过滤时间内,膜通量分别下降了不同的百分组成。在腐植酸溶液中添加钙离子后,膜通量下降更大。  相似文献   

19.
超滤法处理含原油污水的研究   总被引:8,自引:0,他引:8  
本文论述了用聚砜中空纤维超滤膜处理含原油污水的研究,讨论了料液循环速度、操作温度、操作压力和料液浓度对膜传输性能的影响。设计了直径为10.2cm(4英寸)的中空纤维组件和相应的超滤设备,考察了透水速度随操作时间的变化,选用合适的膜清洗工艺,膜透水速度可保持为60L/m~2·h(40℃,1kg/cm~2压力)。工业化实验证明,用中空纤维膜处理含原油污水是成功的,透过液含油量低于10mg/L。该法亦适用于其它种类含油污水的处理。  相似文献   

20.
IntroductionThebrassylicacidmanufacturingwastewatercontainshighchemicaloxygendemand(COD)concentration3000—12000mg/LanditsBOD5/CODisamong04—05Meanwhilethewastewatercontainshighsulphateconcentrationabout13000mg/LanditspHvalueisonly1—2Achemicalcompanyappliedneutrali…  相似文献   