首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A model is developed to define the evaporation rates of solutes from water. The rate equation, similar in form to the Knudsen equation, takes into consideration the effect of air and subwater turbulences on the evaporation loss. At given system conditions, the factor accounting for the air turbulence appears to be essentially constant and independent of temperature (3.5–25°C) for various organic chemicals and water. These characteristics allow one to study the rate of evaporation from water and the relative enhancement by subwater mixing for different solutes. This report shows that the volatilization loss of pure substances and solutes with low Henry's law constants is enhanced by air turbulence, not by subwater mixing. However, the loss of volatile solutes (high Henry's law constants) may be promoted both by air turbulence and by subwater mixing, in which the extent of enhancement by liquid mixing is determined primarily by the Henry's law constant. The present model provides a theoretical basis to explain these effects and others, which appear to be important for assessment of pollutant evaporative transport in the environment.  相似文献   

2.
The environmental impact of a synthetic-fuel spill on a waterway will be determined in part by the rate of dissolution of toxic components into the underlying water and by the rate of removal of those components from the oil by evaporation. In this study, the two film mass transfer model of volatilization was applied to the study of the evaporation of phenols from two synthetic liquid fuels. The rates of evaporation of phenol and alkylated phenols were measured under laboratory conditions. Liquid and gaseous mass transfer coefficients were measured experimentally, and used to calculate Henry's Law coefficients for various phenol-oil pairs from the observed evaporation rates. It was concluded that evaporation rates of phenols from synthetic oils would be significantly less than rates of dissolution in most spills.  相似文献   

3.
A new spectrophotometric method for the determination of benzene in air is described. The method is based upon the nitration of benzene to m-dinitrobenzene and subsequent reduction to m-phenylenediamine. m-Phenylenediamine is determined by diazotization-coupling reaction. α-Naphthol is used as a coupling reagent. Beer's law is obeyed in the range of 10–80 μg of m-dinitribenzene per 25 mL sample. The dye shows a wavelength of maximum absorption at 530 nm. The dye is stable for ~ 30 h. Toluene, the major interferent, can be separated. Beer's law, sensitivity, reproducibility, and other reaction conditions such as time, temperature, and acidity were studied. Formation of stable dye is the main advantage of the method over the butanone method for benzene, in which the colored complex is stable for only 5 min. It is possible to determine traces of benzene (0.05–0.30 μg/mL) by extracting the azo dye in 10 mL iso-amyl alcohol; this also increases the stability of the dye up to 42 h.  相似文献   

4.
A sample of 58 occupied homes in Rochester, NY, most of which incorporated special builder-designed weatherization components, were studied to assess (1) the effectiveness of construction techniques designed to reduce air leakage; (2) the indoor air quality and air-exchange rates in selected airtight houses, and (3) the impact on indoor air quality of mechanical ventilation systems employing air-to-air heat exchangers. The “specific leakage area” was measured in each house using the fan pressurization technique. Houses built with polyethylene vapor barriers and joint-sealing were as a group 50% tighter than a similar group of houses without such components. Mechanical ventilation systems with air-to-air heat exchangers were installed in nine relatively airtight houses, some of which had gas stoves and/or tobacco smoking occupants. Air-exchange rates and indoor concentrations of radon (Rn), formaldehyde (HCHO), nitrogen dioxide (NO2), and humidity were measured in each house for 1-week periods with and without mechanical ventilation. More detailed measurements, including concentrations of carbon monoxide and inhalable particulates, were made in two of these houses by a mobile laboratory. In all nine houses, air-exchange rates were relatively low (0.2–0.5 ach) without mechanical ventilation, and yet indoor concentrations of Rn, HCHO, and NO2 were below existing guidelines. Mechanical ventilation systems were effective in further reducing indoor contaminant concentrations. We conclude that when contaminant source strengths are low, acceptable indoor air quality can be compatible with low air-exchange rates.  相似文献   

5.
A study to measure the transfer of radiocaesium to adult female sheep through a breeding cycle is described. The transfer of radiocaesium from the diet to muscle (estimated as the equilibrium transfer coefficient) was significantly lower to pregnant, and especially lactating, animals compared to non-lactating and barren animals. High dry matter intake rates were also associated with significantly lower transfer coefficients. Known relationships between dry matter intake rates and protein turnover could credibly explain some of these differences. However, when described as the concentration ratio, radiocaesium transfer to meat was apparently highest during lactation. The apparent difference in results obtained by the two approaches of determining transfer is the consequence of daily dry matter intake being a denominator within the estimation of transfer coefficient. A wider discussion of transfer coefficients and concentration ratios leads us to suggest that the concentration ratio is the more robust and potentially generic parameter.  相似文献   

6.
This paper reports a performance analysis for a new sustainable engineering application to beneficially reuse an abundant agricultural waste, coconut coir (Cocos nucifera), in evaporative cooling pads. Two small coconut coir pads of different configurations were fabricated and tested using a laboratory‐scale experimental arrangement. The air supply velocity was controlled and varied between 1.88 and 2.79 m s?1. Heat and mass transfer coefficients, evaporative cooling efficiency and pressure drop across the two types of coconut coir pad were analysed and compared with those of a commercial rigid media paper pad. Results show that the cooling efficiency of the manufactured coconut coir evaporative cooling pad was fairly good (about 50%) and close to that of the commercial paper pad (about 47%). The average pressure drop across the two coconut coir pads was 1.5 and 5.1 Pa respectively. Correlations for heat and mass transfer coefficients expressed using Nusselt and Sherwood numbers are also reported. In addition, the cooling potential of the coconut coir pads was analysed using the average climatic conditions of the central region in Thailand throughout the year. The analysis showed that the air temperature leaving the coconut coir pad varied from 23 to 28°C. Commercial development appears feasible given the coconut coir pad's good performance, lower cost and its availability throughout the country.  相似文献   

7.
This paper describes a new method for the determination of nitrite in potable and polluted water, based on the reaction of nitrite with p-nitroaniline to form diazonium salt and its subsequent coupling with diphenylamine in acidic medium. The pink coloured dye formed obeys Beer's law in the range 0.16 to 0.56 μg/ml at λmax = 540 nm. The molar absorptivity and Sandell's sensitivity being 57.5 × 103 lmole?3cm?1 and 0.0008 μg/cm2, respectively. The optimum reaction conditions and other analytical parameters have been studied. Extraction of the dye with chloroform enhances the sensitivity considerably and makes 0.04 μg/ml of nitrite determinable.  相似文献   

8.
This paper attempts to analyze the environmental problems of Jodhpur city in terms of air quality, water supply, wastewater disposal, and solid waste management. Maps have been prepared to show the boundaries of municipal circles responsible for the disposal of solid wastes. Areas of comparatively higher degrees of air pollution have also been demarcated on the maps. The daily output of urban refuse and the intensity of urban refuse for wards within Jophpur's walled city versus for wards outside the walled city have been cartographically depicted.  相似文献   

9.
A numerical three dimensional model to simulate the transport of Cs and Pu by the Rhone River plume has been developed. The model solves the hydrodynamic equations, including baroclinic terms (that account for density variations) and a turbulence model, the suspended matter equations, including several particle classes simultaneously, settling, deposition and erosion of the sediment, and the radionuclide dispersion equations. Exchanges of radionuclides between the liquid and solid phases are described in terms of kinetic transfer coefficients. The dependence of these coefficients with water salinity is explicitly included in the model since it changes from freshwater to seawater values in the model domain. Computed activity levels in water, suspended matter and bed sediments are, in general, in agreement with measurements in the area. The model can also give a wide amount of information, as distribution coefficients for total suspended matter and sediments and for each particle class, fractions of radionuclides fixed to solid particles, and vertical profiles of radionuclides and distribution coefficients.  相似文献   

10.
Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented. The first two series were dilution experiments; examples of the results are given and discussed. The third series of tests was performed with one person working at a desk in the test room. Above the person;s head, a tracer gas (N2O) was injected into the convection plume, with as low momentum as possible. Starting with zero concentration, a test continued until steady-state conditions were established for the concentration levels in the different parts of the room. The tests included simulation of summer, autumn/spring, and winter daytime conditions. The results indicate a tendency towards lower tracer gas concentrations in the “breathing zone” when the supply air (typical flow rate equivalent to two air changes per hour) is brought into the room at a low level as compared to a high level close to the ceiling. The exhaust air terminal device in all tests was situated high in the “corridor” wall.  相似文献   

11.
Databases have been compiled to derive parameter values relevant to the transfer of radionuclides from feedstuffs to domestic animal products to provide a revision to the IAEA Handbook on transfer parameters TRS 364. Significant new data inputs have been incorporated into the databases from an extensive review of Russian language information and inclusion of data published since the early 1990s. Fractional gastrointestinal absorption in adult ruminants presented in the revised handbook are generally similar to those recommended for adult humans by the ICRP. Transfer coefficient values are presented in the handbook for a range of radionuclides to farm animal products. For most animal products, transfer coefficient values for elements additional to those in TRS 364 are provided although many data gaps remain. Transfer coefficients generally vary between species with larger species having lower values than smaller species. It has been suggested that the difference is partly due to the inclusion of dietary dry matter intake in the estimation of transfer coefficient and that whilst dietary intake increases with size nutrient concentrations do not. An alternative approach to quantifying transfer by using concentration ratios (CR), which do not consider dietary intake, has been evaluated. CR values compiled for the handbook vary considerably less between species than transfer coefficient values. The advantage of the CR approach is that values derived for one species could be applied to species for which there are no data. However, transfer coefficients will continue to be used as few studies currently report CR values or give data from which they can be estimated.  相似文献   

12.
The ARGOS decision support system is currently being extended to enable estimation of the consequences of terror attacks involving chemical, biological, nuclear and radiological substances. This paper presents elements of the framework that will be applied in ARGOS to calculate the dose contributions from contaminants dispersed in the atmosphere after a ‘dirty bomb’ explosion. Conceptual methodologies are presented which describe the various dose components on the basis of knowledge of time-integrated contaminant air concentrations. Also the aerosolisation and atmospheric dispersion in a city of different types of conceivable contaminants from a ‘dirty bomb’ are discussed.  相似文献   

13.
The relationship between the odor strength of total air samples and the odor strengths of the constituents was investigated in three field experiments in an office building and a new preschool. The odor strength was scaled by magnitude estimation according to a master scale principle which results in comparable values for the total and the constituent odors. Between 60 and 120 chemical components were detected by GC/FID in the indoor air samples (N = 66). Most (81%) of the detected components in an air sample were odorous, even though most of them were of the low concentrations. By a method of pattern analysis, chemical as well as odor patterns of indoor air were found to be characteristics of different buildings. From the odor patterns (POG), the “odor print” of the outdoor air associated with the buildings was also recognized in the indoor air. Thus, the “odor print” of an air sample is different from its “chemical print”. A model was found that predicts the overall odor strength of an air sample from the number of FID-detected components most frequently reported to have a strong odor.  相似文献   

14.
Mass transfer and reaction kinetics of raw Nile water ozonation are examined. The contact system is a perfectly mixed reactor, and ozone is bubbled through a glass diffuser at different supply rates. The ozone residual is detected for different reaction time intervals. A simple mathematical model is proposed to describe the mechanism of the ozone reactions in the reactor. The proposed model quite accurately describes the mass transfer behaviour in the reactor and determines the ozone dissociation rate constant, together with the effect of the chemical reaction on the ozone transfer. A linear relationship is observed between the ozone feed rate and the ozone residual. First order reaction kinetics describes fairly well the autodecomposition and the global reaction rates of ozone in raw water. The mass transfer coefficient is about 0.18 min−1. The dissociation and the reaction rate constants are evaluated to be 0.33 mg L−1 and 0.19 mg L−1min−1.  相似文献   

15.
Formaldehyde air levels in a group of houses containing urea-formaldehyde foam insulation (UFFI) in St. John's, Newfoundland, Canada, were measured on at least four separate occasions. The NIOSH method and a portable, commercially available single-beam infrared spectrophotometer was used. No correlation was found to exist between the two methods. The formaldehyde air levels were found to be significantly higher in the group of UFFI-insulated houses than in the control group which did not contain UFFI. Large daily variations in the ambient formaldehyde levels could be observed in some selected UFFI houses, attributable to changes in both exterior and, to a lesser extent, interior conditions. In particular, the effect of direct sunlight on UFFI-containing walls is described.  相似文献   

16.
The amount of NO2 and NO produced by the machine smoking of cigarettes was determined for 15 commercial Canadian brands. Average yield of NO was 1.44 μmoles or about 13% of the average reported for American cigarettes. Levels of NO2 were less than 12% of NO and were probably due to the oxidation of NO. In order to assess the contribution of tobacco smoke to levels of NO in ambient air, 5 brands of cigarettes were smoked in 27 cubic meter controlled environment room. Ventilation conditions were either 2.5 or 5.0 air changes per hour (ACH) and each experiment was replicated 3 times for a total of 30 experiments. Ventilation rates of 0.3 and 1.5 ACH were also selected in a second series of experiments in which only one brand of cigarette was smoked. Least squares estimates for the effective ventilation rates were obtained in the usual manner after linearizing the decay portion of the NO time curve. In each of the experiments, the regression explained at least 95% of the variation in the levels of NO with time. Loss of NO due to factors other than ventilation appeared to be constant within experimental error and averaged 2.22 ACH. Equilibrium values for NO were grossly underestimated when results from currently accepted proecedures for smoke analysis were used in modeling the growth and decay of NO. Goodness-of-fit was improved when equilibrium values were estimated based on observed levels in ambient air. This approach may be more suitable for evaluating the potential contribution of cigarette smoke to levels of indoor air pollutants.  相似文献   

17.
Particulate and gaseous emissions from indoor combustion appliances and smoking can elevate the indoor concentrations of various pollutants. Indoor pollutant concentrations resulting from operating one of several combustion appliances, or from sidestream tobacco smoke, were measured in a 27-m3 environmental chamber under varying ventilation rates. The combustion appliances investigated were gas-fired cooking stoves, unvented kerosene-fired space heaters, and unvented natural-gas-fired space heaters. Results showed elevated levels of carbon dioxide, carbon monoxide, nitric oxide, nitrogen dioxide, formaldehyde, and suspended particles from one or more of the pollutant sources investigated. Our findings suggest that, of the sources examined in this study, nitrogen dioxide from combustion appliances and particles from sidestream cigarette smoke are the most serious contaminants of indoor air, if we use existing standards and guidelines as the criteria. An emission rate model was used to quantify the strengths of the pollutant sources, which are reported in terms of the mass of pollutant emitted per energy unit of fuel consumed (in the case of gas and kerosene appliances) and per mass of tobacco combusted (in the case of smoking).  相似文献   

18.
Historical trends of PCDD/Fs and PCBs from the year 1900 have been reconstructed for the Venice Lagoon area by using a fugacity-based dynamic multimedia model. A novel approach to estimate the inputs to the system was applied. Emissions to the lagoon were estimated by studying dated sediment cores taken from salt marshes located in the lagoon area. These cores have recently proven to be a suitable tool to reconstruct the temporal trends of atmospheric deposition of POPs. According to the model, concentrations of PCBs and PCDD/Fs in air and water reflect the trends of their production and usage, peaking during the 1960s. The peaks in the sediment were delayed by 5-40 years depending on the congener. Predicted concentrations are in good agreement with experimental results. The most important input parameters, identified by a sensitivity analysis, are the degradation constants, K(ow), the Henry's law constant, vapour pressure, active sediment depth, sediment resuspension, and deposition rates, and water residence time in the lagoon.  相似文献   

19.
Caesium (Cs) uptake in roots of winter wheat was found to follow a dual pattern similar to that established for potassium uptake in barley roots. This suggests the operation of two discrete uptake systems for Cs, as for potassium. The ‘System 1’ (low concentration) uptake mechanism for caesium, however, can be resolved into two hyperbolic components which both obey Michaelis-Menten kinetics. The Michaelis-Menten equation was used to derive a function which describes the variation in solution-to-root transfer factor for any element for which the appropriate root uptake constants (Km andVmax) can be determined. This function successfully described available data for root uptake of caesium and potassium, predicting that the solution-to-root transfer factor decreases in relation to an increase in the substrate concentration of each respective element. At substrate concentrations equivalent to carrier-free radiocaesium concentrations, however, the solution-to-root transfer factor predicted by the function and by empirical data suggests that the relationship between root uptake and solution concentration of caesium is linear. These findings are discussed in relation to the comparative physiology of caesium and potassium uptake by plant roots and with respect to the application of the soil-to-plant transfer factor concept to radioecological studies.  相似文献   

20.
We made quarterly determinations of the transfer coefficients and effective transfer coefficients for the radionuclides 137Cs, 90Sr, 40K, 226Ra, 228Ra and 228Th over a full annual cycle, in a Mediterranean grazing-land ecosystem. The input and output fluxes of the radionuclides between the different compartments of this ecosystem were quantified for the following processes: root uptake; variation in root and aerial biomass; pasture production; translocation; leaf fall; efflux due to grazing action; resuspension and subsequent aerial deposition of radionuclides. We observed there to be a marked seasonal variation for this type of ecosystem in both the transfer coefficients and the radionuclide fluxes, which impedes the soil-plant transfer being characterized on the basis of values that are constant with time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号