首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, PCDDs/DFs and co-planar PCBs concentrations in flue gases from 17 crematories and in fly ashes and bottom ashes (mainly bone) from several crematories were measured to grasp the present state of PCDDs/DFs emissions from crematories. The effects of several factors were discussed to prevent PCDDs/DFs emissions from crematories. Total concentration (normalized by 12% O2) of PCDDs/DFs was ranged from 4.9 to 1200 ng/m3 N, and toxic equivalent concentration was ranged from 0.064 to 24 ng TEQ/m3 N. As the results obtained in this research, the following measures to reduce PCDDs/DFs emission are recommended for existing crematories: (1) keeping the temperature at 800 degrees C in main/secondary chambers during a whole cremation, and (2) lowering the temperature in the dust collector. For newly installed crematories, following measures to prevent PCDDs/DFs emission including the measures for existing ones are recommended: (1) connecting one secondary chamber to one main chamber, (2) installing the high efficiency dust collector and reducing dust concentration to less than 0.01 g/m3 N, and (3) installing the sampling point for monitoring of PCDDs/DFs.  相似文献   

2.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

3.
Impact of FEBRA (fermented brown rice with Aspergillus oryzae, a rich dietary fiber) intake on the concentrations of polychlorinated-biphenyls (PCBs), -dioxin-like polychlorinated biphenyls (DLPCBs), -dibenzo-p-dioxins (PCDDs), and -dibenzofurans (PCDFs) in blood of nine married Japanese were studied for 2 years. Concentrations of total PCBs (average+/-standard deviation) were greater 326,000+/-263,000 and 207,000+/-89,000 in FEBRA-intake and non-FEBRA-intake groups, respectively, on pg/g lipid (from now onwards data expressed on pg/g lipid). DLPCBs were second major contaminants 94,000+/-77,000 and 60,000+/-28,000, orderly in FEBRA-intake and non-FEBRA-intake groups. The concentrations of PCDD/DFs were several orders of magnitude lower than those of PCBs, whereas PCDDs were greater (433+/-233 and 512+/-511, in FEBRA-intake and non-FEBRA-intake groups, respectively) than PCDFs (56+/-50 and 43+/-35). Calculated toxic equivalency (TEQ) concentrations were 34+/-24 and 23+/-10 in FEBRA-intake and non-FEBRA-intake groups, respectively. In order to corroborate the impact of FEBRA, the changes of PCDD/DFs and PCB concentrations for 0.5-year, 1-year, 1.5-year, and 2-year samples were estimated from average concentration of 1-day before study commences and 1-week study samples. The results explicit FEBRA-intake group eliminated 7%, 33%, 45%, 36%, and 26% and non-FEBRA-intake group eliminated 8%, 28%, 36%, 31%, and 20% of DLPCBs, PCDDs, PCDFs, PCDD/DF TEQ and total TEQ, respectively. This study is the first of its kind showing the possible elimination of PCDDs, PCDFs and their TEQ in humans from Japan after the consumption of FEBRA.  相似文献   

4.
Yang J  Shin D  Park S  Chang Y  Kim D  Ikonomou MG 《Chemosphere》2002,46(3):419-428
We determined breast milk concentration of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in 24 mothers living in Korea, and assessed the maternal body burden based on PCDDs/PCDFs and PCBs concentrations in breast milk and an infant intake rate through breast-feeding based on their concentration in breast milk. PCDDs/PCDFs and PCBs levels in breast milk from primipara mothers were found to be higher than those from multipara mothers. For total PCDDs/PCDFs TEQ level, 2,3,4,7,8-PeCDD was the predominant congener, and the proportion of 2,3,7,8-TCDD was less than 3% of total PCDDs/PCDFs TEQ level. For PCBs TEQ level, PCB-126 was the predominant congener. Maternal body burden levels of PCDDs/PCDFs and PCBs based on their concentrations in breast milk were 268-622 TEQ ng. The daily dioxin intakes of mothers were predicted to be 0.78-2.18 TEQ pg/kg/day for PCDDs/PCDFs and 0.34-0.66 TEQ pg/kg/ day for PCBs. For the first year, the body burden of an infant was predicted to be 212 TEQ ng and the daily intake of an infant was predicted to be 85 TEQ pg/kg/day, assuming the mean dioxin-related compounds concentration (27.54 TEQ pg/g fat).  相似文献   

5.
Kang YS  Yamamuro M  Masunaga S  Nakanishi J 《Chemosphere》2002,46(9-10):1373-1382
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs) were detected in waterfowl such as common cormorants, tufted ducks, and their prey, namely fish and bivalves from Lake Shinji, Japan. The concentration of total PCDDs/DFs-TEQ was found to be higher in the muscle tissues of common cormorants than in those of tufted ducks. The results of hierarchical cluster analysis implied that the residue distribution pattern of PCDD/DF homologues was considerably different between these two species. Furthermore, biomagnification factors (BMFs) were estimated from bivalves as prey to tufted duck muscles as target organs. Despite the highest concentrations of 1,3,6,8- and 1,3,7,9-TeCDD in tufted ducks and their prey, however, the BMFs of these isomers were calculated to be lower than those of the toxic 2,3,7,8-substituted PCDDs/DFs. On the other hand, log BMF of toxic 2,3,7,8-substituted PCDDs/DFs were significantly higher for lower chlorinated isomers than those of the higher chlorinated isomers. The biota-sediment accumulation factors (BSAFs) of PCDDs/DFs were also estimated using shijimi clam and fish samples against sediment from Lake Shinji. The average BSAFs were estimated and ranged from 4.0×10−3 to 2.2×10−1 and 2.0×10−4 to 2.0×10−1 for bivalve and fish samples, respectively. Based on calculated BMFs and BSAFs, the total PCDD/DF-TEQ levels in the tufted duck were estimated to have been lowest (2.0 pg TEQ/g dry weight basis) in 1947 and highest (9.8 pg TEQ/g) in 1971.  相似文献   

6.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

7.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs) were detected in waterfowl such as common cormorants, tufted ducks, and their prey, namely fish and bivalves from Lake Shinji, Japan. The concentration of total PCDDs/DFs-TEQ was found to be higher in the muscle tissues of common cormorants than in those of tufted ducks. The results of hierarchical cluster analysis implied that the residue distribution pattern of PCDD/DF homologues was considerably different between these two species. Furthermore, biomagnification factors (BMFs) were estimated from bivalves as prey to tufted duck muscles as target organs. Despite the highest concentrations of 1,3,6,8- and 1,3,7,9-TeCDD in tufted ducks and their prey, however, the BMFs of these isomers were calculated to be lower than those of the toxic 2,3,7,8-substituted PCDDs/DFs. On the other hand, log BMF of toxic 2,3,7,8-substituted PCDDs/DFs were significantly higher for lower chlorinated isomers than those of the higher chlorinated isomers. The biota-sediment accumulation factors (BSAFs) of PCDDs/DFs were also estimated using shijimi clam and fish samples against sediment from Lake Shinji. The average BSAFs were estimated and ranged from 4.0×10−3 to 2.2×10−1 and 2.0×10−4 to 2.0×10−1 for bivalve and fish samples, respectively. Based on calculated BMFs and BSAFs, the total PCDD/DF-TEQ levels in the tufted duck were estimated to have been lowest (2.0 pg TEQ/g dry weight basis) in 1947 and highest (9.8 pg TEQ/g) in 1971.  相似文献   

8.
We measured PCDDs/DFs levels in Japanese human livers and adipose tissues in 1999, and TEQ were calculated with WHO TEF. The mean total levels of PCDDs/DFs in livers and adipose tissues were 57 pg TEQ/g on a lipid basis and 49 pg TEQ/g on a lipid basis, respectively. 1,2,3,6,7,8-HxCDD, 1,2,3,4,6,7,8-HpCDD, OCDD, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF and 1,2,3,4,6,7,8-HpCDF concentrations in livers considerably differed from those in 1989 (p < 0.05). The mean non-ortho-chlorine substituted biphenyls levels showed 20 pg TEQ/g on a lipid basis and 17 pg TEQ/g on a lipid basis in livers and adipose tissues, respectively. In livers, the mean of 3,3',4,4'-TCB concentrations was 131 pg/g on a lipid basis, and 7.7-fold higher than that in 1989. The mean total mono-ortho-chlorine substituted biphenyls level was 13.0 pg TEQ/g on a lipid basis in livers and 21.6 pg TEQ/g on a lipid basis in adipose tissues. 3,3',4,4',5-PeCB and 3,3',4,4',5,5'-HxCB levels decreased in adipose tissues, and 3,3',4,4',5-PeCB level only decreased in livers. PCDDs, PCDFs, and mono- and non-ortho-chlorine substituted biphenyls levels may have decreased in livers and adipose tissues because of a governmental policy on dioxins discharge for the decade. Then, we estimated the correlations of PCDDs, PCDFs and the related compound levels between livers and adipose tissues. The correlative PCDDs congeners may have had a similar behavior to that between liver and adipose tissue. On the contrary, most PCDFs isomers may have different behavior between liver and adipose tissue, while 2',3,4,4',5-PeCB (IUPAC No. 123) may also have a different behavior between liver and adipose tissue.  相似文献   

9.
OBJECTIVE: The objective was to grasp the recent body burden levels of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DL-PCBs) and to investigate their determinants among general inhabitants in Japan. METHODS: This study was performed on 1374 participants aged 15-73 years, who were not occupational exposure to PCDDs/PCDFs and DL-PCBs, living widely in 75 different residential areas of 25 prefectures in Japan. Seven PCDDs, ten PCDFs, twelve DL-PCBs, which are assigned a toxicity equivalent factor, and biochemical factors were determined in fasting blood. A questionnaire survey on life-style was also performed. RESULTS: The median of total toxicity equivalent (TEQ) was 20pgTEQ/g lipid. The TEQs of PCDDs/PCDFs, DL-PCBs and total TEQ increased with age. The intake frequency of fish-and-shellfish was positively associated with the TEQ of DL-PCBs in both sexes. Current smoking was negatively related to the TEQ of DL-PCBs in male subjects but not in female subjects. Feeding status was significantly related to the TEQs of PCDDs/PCDFs, DL-PCBs and total TEQ, being lowest in breast feeding and highest in never and bottle feeding. According to the results of subgroup analysis, parity was not associated with the TEQs. CONCLUSIONS: The fish-and-shellfish consumption may contribute to the accumulation of DL-PCBs, and smoking may induce some biological action for the elimination of DL-PCBs from the human body. Breast feeding is considered to be one of the major excretory pathways of PCDDs/PCDFs and DL-PCBs in women, while parity may not largely contribute to the elimination of these pollutants.  相似文献   

10.
Moon HB  Lee SJ  Choi HG  Ok G 《Chemosphere》2005,58(11):1525-1534
Bulk atmospheric samples (wet and dry) were collected monthly throughout a year at urban and suburban areas of Korea to assess the deposition flux and seasonal variations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The PCDDs/DFs deposition fluxes ranged from 1.0 to 3.7 ng TEQ/m2/year in the urban area and from 0.5 to 4.6 ng TEQ/m2/year in the suburban area. The deposition fluxes of PCDDs/DFs in this study were comparable to or lower than those previously reported at different locations. The atmospheric deposition fluxes of particles and PCDDs/DFs in winter tended to be higher than those in summer. However, monthly variations between particle and PCDDs/DFs deposition fluxes were small, and the correlation coefficients between the deposition fluxes of air particles and each homologue group of PCDDs/DFs varied according to the degree of chlorination of the homologue group. The deposition velocity of PCDDs/DFs in the urban area was estimated at 0.04 cm/s, which is a lower value than those found in other studies. The two most likely factors affecting the monthly variation of deposition fluxes are the ambient temperature and the amount of precipitation. In particular, the ambient temperature had an influence on the lower chlorinated homologues of PCDDs/DFs while precipitation had an influence on the higher chlorinated PCDDs/DFs. The PCDDs/DFs profiles in atmospheric deposition bulk samples showed a similar pattern at the urban and suburban sites. The possibility of the loading of PCDDs/DFs by Asian dust events could be partly confirmed by investigation of homologue profiles.  相似文献   

11.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs), including 2378-substituted isomers were present in samples of shellfish and fish, and ambient air collected from Masan Bay, and Masan City, South Korea. Total concentrations of PCDDs/DFs in mussel and clam were 750 pg g(-1), lipid weight (lw), and 3418 pg g(-1), lw, respectively. Total concentrations of PCDDs/DFs in mullet, gizzard and flounder were 52, 82, and 122 pg g(-1), lw, respectively. Shellfish tissues contained a greater number of PCDD/DF isomers, contributing greater total concentrations of PCDDs/DFs compared to fish collected from the same locations. The predominance of 2378-substituted PCDDs/DFs in fish is represented in greater total concentrations of 2378-TeCDD equivalents (TEQs), whereas there was very limited occurrence of 2378-substituted isomers in shellfish. TEQ concentrations in samples of mussel and clam were 0.97 and 12 pg g(-1), lw, respectively. Total TEQs in mullet, gizzard and flounder were 12, 22 and 18 pg g(-1), lw, respectively. In fish 2378-substituted PCDDs accounted for 100% of the total concentrations of PCDDs, and 2378-substituted PCDFs accounted from 59% to 73% of the total PCDFs. The 2378-substituted isomers accounted for only 3% of the total PCDDs/DFs in shellfish. Ambient air collected from two sites contained a wide range of isomers of tetra- through heptachlorinated PCDDs/DFs. Even though the total concentration of PCDDs/DFs in ambient air (12.8 pgm(-3)) collected from an industrial area was 2-fold greater than that in air samples (6.3 pgm(-3)) collected from an urban/rural area, total TEQs (0.07 and 0.08 pgm(-3)) there was no statistical difference between the two samples.  相似文献   

12.
Exposure to dioxins has raised much public concern recently. We determined the congeners' distribution of polychlorinated-dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in the breast milk samples collected in Tokyo, Japan. Breast milk was taken from 240 mothers, 30 days after delivery in 1999 and 2000 in Tokyo, Japan. The actual concentration and TEQ concentration of PCDDs (14 congeners), PCDFs (15 congeners), and dl-PCBs (12 congeners), and each congener's contribution to the total TEQ level were calculated. Among all the samples, PCDDs accounted for 34.8%, PCDFs accounted for 23.5%, dl-PCBs accounted for 41.7%, which was also similar in the breast milk from the primiparae and secundiparae. The main contributors to the total TEQ with increasing percentages were 2,3,4,7,8-PeCDF, 1,2,3,7,8-PeCDD and 3,3',4,4',5-PCB (#126), and they accounted for more than 65% of the total TEQ. Detailed congener analysis in breast milk samples is effective to understand dioxin sources.  相似文献   

13.
Todaka T  Hirakawa H  Hori T  Tobiishi K  Iida T  Furue M 《Chemosphere》2007,66(10):1983-1989
We measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), non-ortho polychlorinated biphenyls (non-ortho PCBs) and mono-ortho polychlorinated biphenyls (mono-ortho PCBs) in blood collected from 279 Yusho patients living in Japan, 92 Yusho-suspected persons living in Japan and 127 normal controls living in Fukuoka Prefecture, and compared among the groups in terms the concentrations of these compounds. The total toxic equivalents (TEQ) concentrations of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs in the bloods of Yusho patients and Yusho-suspected persons were 161.4 and 51.2 pg TEQ/g lipid, respectively and were about 3.5 and 1.1 times higher than those of normal controls, respectively. Although the TEQ concentrations of PCDDs, non-ortho PCBs, and mono-ortho PCBs among Yusho patients, Yusho-suspected persons and normal controls were nearly the same, the PCDFs levels of Yusho patients were significantly higher than those of Yusho-suspected persons and about 10.3 times higher than those of normal controls. In Yusho patients, PCDFs contributed about 65% to the total TEQ concentration. Among the PCDFs congeners for Yusho patients, the concentration of 2,3,4,7,8-pentachlorodibenzofuran (PeCDF) was about 11.3 times higher than that of normal controls. These findings indicated that Yusho patients even now, more than 34 years after the outbreak of Yusho, have much higher blood levels of 2,3,4,7,8-PeCDF in general than do unaffected persons.  相似文献   

14.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

15.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):701-707
This study was carried out to examine the formation and the emission status of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in the flue gases of commercial-scale municipal solid waste (MSW) incinerators, and thus to provide the engineering data for the reduction of PCDDs/PCDFs emitted from MSW incinerators. The formation concentrations of the PCDDs/PCDFs generated at the outlet of waste heat boilers (WHB) were in the range of 1.18-29.61 ng-TEQ/N m3 (average 5.75 ng-TEQ/N m3), while the emission concentrations at the stacks were in the range of 0.026-4.548 ng-TEQ/N m3 (average 0.924 ng-TEQ/N m3). Two major 2,3,7,8-substituted congeners were 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF, and their concentrations were up to 50% and 64% of total TEQ values at the outlet of WHB and the stack, respectively. From the results of multi-regression analysis, the formation concentration of PCDDs/PCDFs could be predicted as follows with the correlation factor of r2 = 0.962: PCDDs/PCDFs (ng-TEQ/N m3) = 3.036 (Cl) + 0.094 (T1) - 0.472 (Combustibles) + 0.059 (CO) - 0.039 (THC) - 3.366 (H) + 22.157, where T1 (degrees C) is the temperature at the outlet of the WHB. Cl, Combustibles and H are given as percentages and the others are in parts per million.  相似文献   

16.
We measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), non-ortho coplanar polychlorinated biphenyls (non-ortho PCBs), and mono-ortho coplanar polychlorinated biphenyls (mono-ortho PCBs) in blood collected between 2002 and 2004 from 195 pregnant women living in Sapporo City of Hokkaido Prefecture, Japan. The present study is one of the few studies in which PCDDs, PCDFs, and dioxin-like PCBs have been measured in the blood of pregnant women. Of the 195 pregnant women, 101 were primipara (mean: 28.8 years) and 94 were multipara (mean: 32.4 years). The arithmetic mean total TEQ concentrations of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs of primiparous and multiparous mothers in Sapporo City were 17.4 (median: 15.7) and 14.0 (median: 13.9)pgTEQ/glipid, respectively, and the concentrations were in the range of 6.6-43.4 and 3.4-28.2pgTEQ/glipid, respectively. In regard to the relationship between the total TEQ concentrations of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs in maternal blood and the number of deliveries or age of primiparous and multiparius mothers, the levels of these dioxin-like compounds tended to decrease with increases in the number of deliveries and significantly increased with increasing maternal age in both groups. Furthermore, significant correlations were observed between the total TEQ concentrations of these dioxin-like compounds and the age of primiparae and multiparae. The total TEQ concentration of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs measured in 195 pregnant women has decreased compared to past levels in Japan for the last several decades. The results of the present study have indicated that dioxin contamination in the blood of young women in Japan is continuing to decrease.  相似文献   

17.
Wang LC  Lee WJ  Tsai PJ  Lee WS  Chang-Chien GP 《Chemosphere》2003,50(9):1123-1129
This study investigated four sinter plants, classified into two categories--with selective catalytic reduction (SCR) (S1, S2 and S3) and without SCR (S4) as its air pollution control device. Polychlorinated dibenzofurans (PCDFs) are dominant in the stack flue gases of sinter plants with and without SCR. The polychlorinated dibenzofurans/polychlorinated dibenzo-p-dioxins (PCDFs/PCDDs) ratio exceeds 1 extremely. The degree of chlorination of the sinter plant without SCR is towards hepta and hexa congeners while that of the sinter plant with SCR is towards penta and hexa congeners. PCDD/Fs are indeed decomposed (75.5% and 69% on ng and ng TEQ bases, respectively) and not only reduced in degree of chlorination. The overall concentration in the stack flue gas of sinter plants with SCR (7.97-14.1 ng/Nm(3); 0.995-2.06 ng TEQ/Nm(3)) is lower than that of the sinter plant without SCR (28.9 ng/Nm(3); 3.10 ng TEQ/Nm(3)). In Taiwan, based on the emission factors of 0.970 microg TEQ/ton-feedstock (sinter plants with SCR) and 3.13 microg TEQ/ton-feedstock (sinter plant without SCR), the annual PCDD/F emission of 44.7 g TEQ/year from sinter plants is 60 and 121 times higher than those from municipal solid waste incinerators (0.750 g TEQ/year) and MWIs (0.369 g TEQ/year). These results show that sinter plants have become the dominating PCDD/F emission source since tighter emission limits have been applied to incinerators.  相似文献   

18.
Removal of PCDDs/DFs and dl-PCBs in MWI fly ash by heating under vacuum   总被引:1,自引:0,他引:1  
Temperature dependence of PCDD/DF and dioxin-like polychlorinated biphenyl (dl-PCB) concentrations in fly ash from a municipal waste incinerator (MWI) heated under vacuum has been investigated as a function of sample temperature ranging from T(s)=425 to 800 K to find out if PCDDs/DFs in fly ash evaporate and are trapped in a liquid nitrogen-cooled trap. The results show that more than 99.98% of PCDDs/DFs in TEQ is removed from fly ash by vacuum heat treatment at T(s)>650 K for 4 h. Almost no PCDDs/DFs were detected in the liquid nitrogen-cooled trap. Homologue distributions indicate that dechlorination/hydrogenation (DCH) reactions proceed in fly ash at T(s)>450 K. Arrhenius rate parameters for the DCH reactions have been determined for each homologue assuming that only DCH reactions occur. The fly ash heated under vacuum at 650 or 800 K was reheated at 573 K (300 degrees C) in a stream of dry or humid air to see how much PCDDs/DFs and dl-PCBs are regenerated. We have found that (1) PCDDs/DFs are regenerated in both 650 K and 800 K treated fly ash, whereas dl-PCBs are regenerated in 650 K treated fly ash, (2) formation of PCDFs predominates over that of PCDDs or dl-PCBs, and (3) less chlorinated homologues are abundant for PCDDs/DFs and dl-PCBs.  相似文献   

19.
The major sources of dioxins (polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs)) in the environment in Japan have been considered to be combustion by-products, pentachlorophenol (PCP) formulations, chlornitrofen (CNP, 4-nitrophenyl-2,4,6-trichlorophenyl ether) formulations, and PCB products. Data on PCDDs, PCDFs and DL-PCBs from the four sources were analyzed, and indicative congeners whose concentrations were highly correlated with WHO-2006 toxic equivalencies (TEQs) were identified for each source sample. The indicative congeners for combustion by-products, PCP formulations, and CNP formulations were 2,3,4,7,8-pentachlorodibenzofuran, 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin, and 1,2,3,7,8-pentachlorodibenzo-p-dioxin, respectively; for PCB products, the indicative congeners were IUPAC Nos. #126- and #105-pentachlorobiphenyls. Moreover, using the data on PCDDs, PCDFs and DL-PCBs, we developed a set of equations for estimating the apportionment of TEQs from the four sources by using only the concentrations of the above-mentioned five indicative congeners. The equations were used along with the analysis results of different types of environmental samples collected from Japan, to determine the TEQ contributions of the four sources. The obtained values of TEQ contributions seemed to be reasonable. The estimation method was developed by using the data on major dioxin sources in Japan, and therefore, it is generally adaptable to environmental samples from any part of Japan. The method may be usable for regions outside Japan if source identification is carried out and the estimation equations are modified appropriately.  相似文献   

20.
Yasuhara A  Katami T  Shibamoto T 《Chemosphere》2006,62(11):1899-1906
Polyvinylidene chloride (PVDC; polymer of 1,1-dichloroethylene) was combusted with paper in a well-controlled, small-scale incinerator at an average grate temperature of 700 °C, and then dioxins (PCDDs, PCDFs, and coplanar-PCBs) formed in the exhaust gases were analyzed by gas chromatography/mass spectrometry. PVDC lowered the combustion temperature due to its less flammable character. The amount of total dioxins (PCDDs + PCDFs + coplanar-PCBs) formed in the exhaust gas was 58.0 ng/g of a combustion sample and its toxicity equivalency quantity (TEQ) value was 0.64 ng-TEQ/g. The amount of PCDDs formed in the sample ranged from 2.33 ng/g (Cl8-isomer) to 0.048 ng/g (Cl1-isomer). The lower the number of chloride, the less production of PCDDs. On the other hand, there was no relation between the number of chloride and PCDF formation. The amount of PCDFs formed in the sample ranged from 8.02 ng/g (Cl2-isomer) to 4.46 ng/g (Cl8-isomer). A polyvinylchloride (PVC) sample produced 207 ng/g of total dioxins and a PVDC sample produced 57.4 ng/g of total dioxins when they were combusted under the same conditions. An approximately equal composition of dioxin isomers was formed from PVDC and PVC samples. Paper was found to contribute to PCDF formation when it was combusted with plastics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号