首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
It is well known that the commonly used k- turbulence models yield inaccurate predictions for complex flow fields. One reason for this inaccuracy is the misrepresentation of Reynolds stress differences. Nonlinear turbulence models are capable to overcome this weakness while being not considerably more complex. However no comprehensive studies are known which analyze the performance of nonlinear turbulence models for three-dimensional flows around building-shaped structures. In the present study the predictions of the flow around a surface-mounted cube using three nonlinear two-equation turbulence models are discussed. The results are compared with predictions of the standard k- turbulence model and wind tunnel measurements. It is shown that the use of nonlinear turbulence models can be beneficial in predicting wind flows around buildings.  相似文献   

2.
A method to evaluate aquatic mortality given a pollutant distribution is presented and applied to several sample low pH plumes representing various ocean CO2 disposal schemes. The method is an improvement over current analysis because it integrates the mortality due to timevarying exposure to low pH with the probabilistic experiences of passive organisms subject to turbulent lateral diffusion as they pass through the plume. For the examples presented, the plume was discretized laterally into lanes and longitudinally by time steps, and a random walk model accounting for the scaledependent nature of relative diffusion was used to simulate the organism pathways over one time step. From these simulations, the probability that an organism will be in a given lane, , one time step after it starts from an initial lane, , was determined for all combinations of and . These probabilities were used to find the number of organisms following each of the possible pathways, and the mortality to the organisms due to their time varying exposure to low pH was determined by using the toxicity model described in part I of this paper. The integrated method allows the impact of the plume to be described in terms of total organism mortality as well as spatial deficit of organisms.  相似文献   

3.
Beryllium concentrations in atmospheric particulate and soil samples in and around a Beryllium Processing Facility (BPF) have been measured. The mean air concentration level of beryllium in and around the fence line of the BPF is 0.48 ± 0.43 ng m-3 (n = 397) and is mostly influenced by diurnaland seasonal changes. The observed air concentration levelswere well below the prescribed ambient air quality (AAQ)standard of 10 ng m-3. The soil concentration levels ofberyllium in the study area were found to be in the range of 1.42–2.75 g g-1. The mass median aerodynamic diameter (MMAD)of beryllium aerosols in ambient air was found to be 6.9 m.Source identification using the Enrichment Factor (EF) approachindicates soil as the predominant contributory source for air concentrations at the site.  相似文献   

4.
It is more and more recognised that an estimation of the exposure of the population to air pollutants is more relevant than the ambient air quality, since it gives a better indication of health risk. Outdoor workers in an urban region are generally of low income status and are exposed to higher levels of both indoor and outdoor air pollution. Hence respondents from this population subgroup have been selected for this study. Outdoor workers are divided into two categories, viz. traffic constables and casual outdoor workers like watchmen, roadside shopkeepers etc. Most of the respondents are from the lower income group. Each respondent is monitored for a continuous 48-hour period. The sampling frequency is once a week.The study region is situated in the north-west part of the Greater Mumbai Municipal Corporation. It can be classified as industrial cum residential area. The daily integrated exposure of the outdoor workers consists of two major micro-environments, viz. occupational and indoor residential.A personal air sampler was used along with a cyclone to measure levels of Respirable Particulate Matter (RPM). The cyclone has a 50% removal efficiency for particle diameter of 5 m. Paired samples of PM10 (ambient) and RPM (personal) were collected to establish the correlation between them. The average 24-hour integrated exposure to RPM was 322 g/m3 and exceeded the corresponding PM10 level observed at the nearest Ambient Air Quality Monitoring Station by a factor of 2.25. The 90% confidence interval for this exposure is 283–368 g/m3. This study clearly demonstrates that the daily integrated exposure and therefore the health risk of outdoor workers in an urban area is significantly more serious than that indicated by ambient air quality data.  相似文献   

5.
Trends in total suspended particulates (TSP) emissioninventories were compared with ambient TSP concentrationsduring the period of 1993-1999 in the Czech Republic. TheTSP annual emission decreased within the period of observationfrom 441 300 to 67 000 of metric tonnes (by 85%). During thesame period a less pronounced downward trend from80.3 g m-3 to 31.5g m-3 (decrease by 61%)was noted also for the ambient TSP annual average. Differencebetween the two air quality indicators seems to indicate thatchanges in TSP emission inventories from year to year arebeing to some extent overestimated. Monthly ambientparticulate concentrations did not respond to overall drop inemissions proportionately but were closely associated withmonthly mean temperatures. While in the winter the correlationbetween ambient TSP and temperature was negative, in summerthe correlation between the two variables was positive. Inspring and autumn there was no clear correlation betweentemperature and ambient particulate pollution. The improvementof air quality in the Czech Republic since the economical andpolitical transformation in 1990s is substantial whendemonstrated by emission figures, however, true state ofparticulate pollution expressed by ambient levels requiresfurther attention.  相似文献   

6.
Housedusts and garden soils were sampled in 14 houses in the vicinity of a secondary Pb smelter and analysed for concentrations of Pb, Zn, Cu, Cd, As, and Hg. Sixty-one topsoil samples were also taken from a 2 km2 grid covering the smelter grounds and surrounding residential areas and analysed for concentrations of Pb, Zn, Cd and Cu. Contour maps generated from the grid data indicate significant contamination in the area (maximum Pb concentration 58 500 g g-1), particularly down-wind of the smelter grounds. A geometric mean Pb concentration of 2225 g g-1 was recorded in garden soil and similarly elevated levels were recorded for Zn, Cd, As and Sb. In housedusts, a geometric mean Pb concentration of 1668 g g-1 was observed. Whilst housedust metal concentrations were generally elevated, compared to other urban or residential areas, there appears to be a large degree of attenuation of the metals between the exterior and interior environments of the homes studied. A significant correlation was not recorded between metal concentrations of garden soils and housedusts. There were significant correlations for: distance from the smelter against garden soil metal concentrations; garden soil metal concentrations against each other; housedust metal concentrations against each other; and house age against garden soil metal concentrations.  相似文献   

7.
On the Kola Peninsula, the mining and concentration industry exerts anthropogenic impact on the environment. Tailing dumps cause airborne pollution through dusting, and waterborne pollution due to direct dumping and accidental releases. The objectives were: (1) to analyse multidate satellite imagesfor 1964–1996 to assess the environmental pollution from themining and concentration activity in the Kola in temporal perspective; (2) to evaluate remote sensing methods for integrated environmental impact assessment. The area of mining and industrial sites steadily expands and amounted to 94 km2 in 1996. The polluted water surface amounted to at least 150 km2 through dumping in 1978 and to 106 km2 in1986 due to dusting. Thus, the impact from the mining and concentration activity should be reconsidered as more significant than it was officially anticipated. In the past the main mechanism of pollution wasdirect dumping into the lakes. Currently and in future, airborne pollution after dusting storms will dominate. The effective recultivation of the tailing dumps will be a long-term process. For effective assessment of impacts from the mining and concentration industry, remote sensing methods should be complemented by in-situ measurements, fieldwork, and mathematical modelling.  相似文献   

8.
Computer simulations tested the ability of gravel interceptor trenches to capture a plume of contaminated groundwater. The plume had a maximum length and width of 87 and 19 m, respectively. In alternate simulations, one-meter wide trenches were located 5, 10, 20, and 50 m downgradient of the plume. A minimum trench length and time required to capture the plume was determined for each location (setback). The plume was considered captured if it passed entirely through a trench. A 21 m-long trench captured the plume at setbacks of 5 and 10 m. Minimum trench length increased to 23 and 25 m at setbacks of 20 and 50 m, respectively. Increased contaminant spreading with distance traveled dictated longer trenches at larger setbacks. Results of this study suggest that, at settings where contaminant plumes are carefully monitored and spatially defined, passive interceptor trenches should be close to a plumes leading tip and slightly longer than the maximum width of the plume.  相似文献   

9.
Air pollution has been associated with adverse health effects. Difficulties in interpreting studies of health effects of exposure to air pollution arise in estimating exposure. Until recently, studies of effects of air pollution have relied on pollution exposure measurements obtained from fixed location air pollution stations monitoring outside air (to evaluate compliance with air quality standards, rather than to examine population exposure). However, recent evidence suggests that there are substantial differences between air pollution levels measured at such sites and levels to which people are actually exposed, i.e. personal exposure. The present study examines effects of ambient urban air pollution on persons suffering from asthma, healthy non-asthmatic subjects and school children (in 2 Canadian cities, Toronto and Hamilton). Air pollution exposure is being assessed by data obtained from: (1) conventional abatement oriented fixed location air pollution monitoring stations, (2) an extensive population oriented network, (3) inside and (4) outside structures (homes and schools) as well as (5) personal air pollution samplers. The data indicate variability in these different estimates of exposure which have implications on health effects assessment.  相似文献   

10.
This paper describes a novel technique of measuring ambient hydrogen sulphide (H2S) concentrations simultaneously at several locations around a wastewater treatment plant. A commercially purchased H2S monitor is modified to operate in a static mode to enable degree of darkening on pieces of lead acetate tapes to be correlated againts the exposure duration and the ambient H2S concentration of sewage air. The technique can yield mapped contours of time—average H2S concentrations as low as 0.2 ppm. The methodology is exemplified for a wastewater treatment plant in Ipswich, Queensland. Isopleths of H2S concentration obtained at the wastewater site for two different meteorological conditions reveal that high levels of H2S are detected around the plant's inlet structure and primary clarifiers.  相似文献   

11.
Natural attenuation (NA) is a catchall explanation for the overall decay and slowed movement of the contaminants in the subsurface. One direct support to NA is to demonstrate that contaminant concentrations from monitoring wells located near the source are decreasing over time. The decrease is summarily expressed in terms of an apparent half-life that is determinedfrom the line best fitting the observed log-transformed concentration data and time. This simple (time-only) decay modelassumes other factors are invariant, and so is flawed when complicating factors – such as a fluctuating water table – are present. A history of the water-table fluctuation can track changes in important NA factors like recharge, groundwater flow direction and velocity, as well as other non-NA factors like volume of water in and purged from the well before a sample is collected. When the trend in the concentrations is better associated with the water table rising or falling, any conclusionabout degradation rate may be premature. We develop simple regressions to predict contaminant concentration (c) by two line models: one involving time (c c(t)), and another involving groundwater elevation (c c(z)). We develop a third model that includesboth factors (c c(t, z)). Using an F-test to compare the fits to the models, we determine which modelis statistically better in explaining the observed concentrations. We applied the test to sites where benzene degradation rates had previously been estimated. The F-testcan be used to determine the suitability of applying non-parametric statistics, like the Mann-Kendall, to the concentration data, because the result from the F-test canindicate instability of the contaminant plume that may bemasked when the water table fluctuates.  相似文献   

12.
Aldehydes are an airborne byproduct of many industrialprocesses, vehicle transportation, and emissions fromnumerous natural sources. To characterize aldehydeconcentrations in ambient air of the Savannah, Georgiaarea, air samples for 3 aldehydes (formaldehyde,acetaldehyde, and propionaldehyde) were collected atfive sites on a monthly basis over a 12-month periodfrom December of 1995 through November 1996. Four ofthe sites were in central Savannah and the fifth sitewas located in a rural area about 56 km south ofSavannah. During each 24-hr sampling episode, sampleswere collected in two 12-hr periods approximatingdaylight and nighttime hours, following U.S. EPAMethod TO-11. Formaldehyde concentrations ranged from0.17 to 6.80 g m-3, acetaldehydeconcentrations ranged from 0.07 to7.60 g m-3, and propionaldehyde levels rangedfrom 0.02 to 9.10 g m-3. On average, thefour sites in Savannah had higher aldehydeconcentrations than the rural site (2.0 versus1.2 g m-3 for formaldehyde, 2.3 versus1.7 g m-3 for acetaldehyde, and 1.2 versus1.0 g m-3 for propionaldehyde). The daytimeconcentrations for formaldehyde and acetaldehyde werehigher than the nighttime levels. The data from allthe sites were within published worldwide backgroundvalues for aldehydes.  相似文献   

13.
The adsorption behaviour of Diphenylamine (DPAM), napthylamine ( NAM), napthylamine ( NAM)and aniline on pyrolusite and activated carbon has been studied.Pyrolusite shows remarkable sorption capacity for DPAM and NAM as compared to aniline; (the adsorption followed theorder:Activated Carbon: DPAM = NAM > AnilinePyrolusite: DPAM: NAM > NAM> Aniline)The maximum adsorption of NAM occurred in theconcentration range 4–20 g mL-1 on pyrolusite (95%)and 4–50 g mL-1 on activated carbon (100%). Theeffect of various doses of activated carbon on the adsorption of NAM confirm Langmuir and Freundlich isotherms where asFreundlich isotherm is obeyed by pyrolusite. The adsorption of NAM on both the absorbents is not affected in presence ofDPAM over a wide range of their initial concentrations (20–60g mL-1). The desorption studies of NAM onpyrolusite was carried out by batch as well as column processes.Excellent results were obtained when a mixture of n-hexane andisopropanol (91:1) was used as eluent.  相似文献   

14.
A microwave-assisted solvent extraction (MASE) technique was developed for the quantitative extraction of gasoline- and diesel-range petroleum hydrocarbons (PHs) from soil and marine sediment samples. The influence of different extracting solvents, extraction temperature and duration of extraction on the recoveries of PHs was evaluated using a two-level orthogonal array design (OAD) with a OA8(27) matrix. Gas chromatographic-mass spectrometry (GC-MS) in multiple selective ion monitoring (MSIM) mode was used for the analysis of the PHs in environmental samples. The spiking range of the PHs in the environmental samples was between 1 to 1000 g/g. Good recoveries (>80%) could be obtained for most of the PHs using the optimum MASE conditions. The limit of detection (LOD) achieved by the GC-MS-MSIM was 0.02 g/g. A preliminary survey for the levels of PHs in marine sediment and soil samples from different parts of Singapore was carried out using the method.  相似文献   

15.
Since 1987 tree crown condition is surveyed annually in large parts of Europe mainly in terms of defoliation. The plot-wise means of defoliation from 1994 to 2000 were evaluated by General Linear Models (GLM) in order to describe country-specific levels of defoliation and age-trends. Additional runs with estimates for influences of insects and fungi were performed. The amount of variance of defoliation explained by country, age and its interaction was between 35% and 59% for the main tree species, except for Quercus ilex. Additionally, up to 10% could be explained by the inclusion of estimates for infestations by insects and fungi. Residuals of the GLMs were taken as a measure of forest condition not biased by country or age effects and interpreted as preliminarily adjusted defoliation (PAD). PAD values were analysed using geostatistical methods. The modelled spatial autocorrelations were used for kriging. The resulting maps give an overview on regions with elevated defoliation, which may pinpoint regional causes of defoliation. The elimination of methodologically caused variance is a precondition of any cause–effect oriented analyses. The combination of explorative modelling and geostatistics will promote the choice of further promising predictors.  相似文献   

16.
Different urban air pollution problems deal with complex structure of air flows and turbulence. For such problems the Computer Fluid Dynamics (CFD) methods become widely used. However, this approach despite a number of advantages has some problems. Experience of use of CFD tools for development of models and suggestions of their applications for a local scale air pollution over a complex terrain and stable stratification are discussed in this paper, including: Topography and complex geometry: choose of the co-ordinate system and computer grid; Turbulence closure for air pollution modelling: modified k- model for stable stratified ABL; Boundary conditions for vertical profiles of velocity for stable-stratified atmosphere; Effects of the radiation and thermal budget of inclined surfaces to dispersion of pollutants; Artificial sources of air dynamics and circulation.Some examples of CFD applications for air pollution modelling for a flat terrain, mountainous area, mining open cast and indoor ventilation are discussed. Modified k- model for stably-stratified ABL is suggested. Due to the isotropic character of the k- model a combination of it in vertical with the sub-grid turbulence closure in horizontal can be more suitable for ABL. An effective scheme of boundary conditions for velocity profiles, based on the developed similarity theory for stable-stratified ABL, is suggested. Alongside with the common studies of atmospheric dispersion, the CFD methods have also demonstrated a good potential for studying anthropogenic and artificial-ventilation sources of air dynamic and circulation in local-scale processes of air pollution.  相似文献   

17.
MAPPING TROPICAL DEFORESTATION IN CENTRAL AFRICA   总被引:3,自引:0,他引:3  
The NASA Landsat Pathfinder Humid Tropical Deforestation Project was to map deforestation activities in the humid tropics using datasets from both the Landsat TM (Thematic Mapper) and MSS (Multispectral Scanner System). In Central Africa, its effort had been constrained by the availability of cloud-free satellite coverage, especially for the 1970s Landsat MSS imagery. Here, we reported the deforestation rate and its spatial variability in the region using 18 pairs of co-registered Landsat TM imagery from the 1980s to 1990s. Of the total classified area of 416000 km, there were approximately 217000 km2 of dense forest and 24000 km2 of degraded forest in the 1980s. A total of 1012 km2 of forest, including 542 km2 of dense forest and 470 km2 of degraded forest, were cleared annually with an annual deforestation rate of 0.42%, varying among scenes ranging from 0.03 to 2.72%. Additionally, an average of 0.12% (ranging from 0.01 to 0.77% among scenes) or 257 km2 of dense forest was degraded annually. Regression analyses indicated that extensive deforestation occurred in areas with larger forest cover, including dense and degraded forests. Image interpretation also confirmed the hypothesized relationship between deforestation and forest accessibility. The annual clearance of the dense forest was significantly related to the rural population density, and there was a positive relationship between the dense forest degraded during the 1980s–1990s and the degraded forest area in the 1980s.  相似文献   

18.
Air concentrations of 28 of the most commonly used household pesticides were measured inside nine homes in Jacksonville, Florida, and compared with corresponding outdoor levels. The households selected were sorted into three categories according to the degree of pesticide indoor usage. Personal air monitoring was also performed on one resident of each household by means of a portable sampler, which was kept with the person at all times. Five of the pesticides were found in the air inside of the majority of the homes at concentrations as high as 15 gm–3 (average concentrations, 12 ngm–3 to 2.4 gm–3). Indoor levels were generally one to two ordrrs of magnitude higher than surrounding outdoor air levels and personal air measurements were within ± 50% of corresponding indoor values. All samples were collected over 24-hr periods on polyurethane foam and analyzed by capillary colum gas chromatography with mass spectrometric and/or electron capture detection.  相似文献   

19.
The simultaneous behaviour of seven ecological indices(Hurlberts, Margalefs, Menhinicks, Shannons,species number, Jaccards and saprobic index) wasstudied based on phytoplankton data close to the shoreon the East coast of Sweden during the summer 1998.The sampling stations had a similar eutrophicationlevel and were located in bays. Standard phytoplanktondatabases were used in calculating the indices, whichwere later compared using cluster analysis.Hurlberts, Margalefs, Menhinicks, Shannons andspecies number indices, as measure of communitydiversity, produced similar trends which oftendiffered from those based on Jaccards index ofsimilarity. However, the simultaneous use of theseindices was found meaningful as a possible part of themonitoring close to the shore. The application of asaprobic index lead to erroneous conclusions in thestudied case.  相似文献   

20.
The article presents the results of chemical andmicrobiological measurements of the water quality in theBuko Blato reservoir, the largest in Europe, in the period 1989 to 1998.The aim was to observe possiblechanges in water quality during the past decade and itsinfluence on the downstream section of the Cetina River andits numerous tributaries and reservoirs, where there are twolarge regional water supply systems. This reservoir wasbuilt in order to exploit the high hydro-electric potentialof small streamflows in the karst fields of south-westernBosnia. It has strongly influenced the hydrologicconditions of the downstream section of the Cetina River.Buko Blato is a relatively shallow reservoir with the meandepth of 5 m. It covers an area of 57 km2. The waterexchange in the reservoir is slow, occurring from one toseveral years. When the water inflow exceeds the hydroelectric plant demands the excess water is delivered by a reversible channel and pre-pumped into the Buko Blato reservoir. The total and carbonate water hardness in thereservoir is lower than in the Cetina River and in typicalkarst streamflows, since the water in this reservoir comesmainly from surface sources including numerous springs withhigh capacity oscillations, torrents and rainfall.Measurements, carried out during the past years, showed asignificant increase in nitrate content as well as in thecoli bacteria and a less significant increase in totalphosphorus content. The water quality was evaluated asmezotrophic according to the total phosphorus content basedon the Carlson index of trophic level, a lower quality thanin the Perua reservoir, upstream on the Cetina River. Thelatter contains a smaller phosphorus content and wasclassed between oligotrophic and mezotrophic. According tothese data, employing the Vollenweider equation, the totalphosphorus content in this water should not exceed the meanof 20 mg m-3 P. The results indicate that the water inthe Buko Blato reservoir did not deteriorate the waterquality on the downstream section of the Cetina River.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号