1.
采用厌氧 缺氧SBR反应器对以硝酸盐作为电子受体的反硝化除磷过程进行了研究。结果表明 ,反硝化聚磷菌完全可以在厌氧 缺氧交替运行条件下得到富集。稳定运行的厌氧 缺氧SBR反应器的反硝化除磷效率 >90 % ,出水磷浓度 <1mg L。进水COD浓度对反硝化除磷的效率影响很大 ,在COD浓度 <180mg L时 ,进水COD浓度越高 ,除磷效率也就越高。较高浓度的进水COD浓度将导致有剩余的COD进入缺氧段 ,对反硝化吸磷构成不利影响。污泥龄为 16d时 ,厌氧 缺氧SBR反应器取得稳定和理想的反硝化除磷效果。污泥龄减少到 8d ,由于反硝化聚磷菌的流失导致反硝化除磷效率的下降。当污泥龄恢复到 16d时 ,经过一段时间的运行 ,反硝化聚磷菌重新得到富集 ,除磷效率恢复到 90 %以上。  相似文献   

2.
Kim EH  Lee DW  Hwang HK  Yim S 《Chemosphere》2006,63(2):192-201
A phosphorus crystallization process for recovering phosphates was developed using a completely mixed reactor and powdered converter slag as a seed crystal. This completely mixed phosphorus crystallization process achieved a stable and high phosphorus recovery: the average PO4-P removal efficiency during 200 d of operation was 87%, with a range of 70-98%. The apparent volume of the slag doubled due to crystal growth during the long-term phosphorus-removal experiments. The Ca2+ concentration, slag dosage, and temperature were found to govern the phosphorus recovery system for a given condition of pH and hydraulic retention time. The equations for the rate constant and reaction order were obtained by evaluating the model parameters. The model developed in this study was observed to successfully simulate the behavior of effluent PO4-P in a completely mixed phosphorus crystallization reactor over a wide variety of operating conditions of temperature, Ca2+ concentration, and influent PO4-P. Model investigations of design factors suggest that the completely mixed phosphorus crystallization process with influent PO4-P concentrations of less than 10 mg l(-1) could ensure effluent PO4-P concentrations of less than 0.5 and 1.0 mg l(-1) during summer and winter in Korea, respectively.  相似文献   

3.
COD对生物除磷颗粒污泥稳定性影响研究   总被引:3,自引:1,他引:2  
颗粒污泥稳定性是影响其应用的主要因素之一.以SBR中成熟的生物除磷颗粒污泥为研究对象,探讨进水COD浓度对系统稳定性的影响.结果表明,当进水COD浓度由300 mg/L逐渐升高到500 mg/L时,磷去除率由93%降低到88%;当进水COD浓度在400 mg/L以下时,污泥的最大比释磷速率和比吸磷速率分别为45.2 m...  相似文献   

4.
重点考察了-种改良型膜生物反应器(A2/O—MBR)的脱氮除磷性能。该工艺主要特点在于对膜池硝化回流液进行了固液分离,并将上清液和浓缩污泥分别回流至缺氧池和厌氧池,这种改进提高了系统对氮、磷的同步去除效率。实验结果表明,在水力停留时间(HRT)为12h,污泥龄(SRT)为30d,混合液回流比为200%的运行条件下,进水COD、NH4+-N、TN和TP平均浓度分别为(225±38)、(24.8±3.9)、(26.7±2.9)和(2.90±0.53)mg/L时,增加膜池硝化回流液固液分离装置前后,系统对COD和NH4+-N的去除都维持在较高水平,而系统对TN和TP的去除效果显著提高,出水TN和TP平均浓度分别由(14.9±3.3)mg/L和(1.95±0.72)mg/L下降到(9.4±1.9)mg/L和(0.91±0.38)mg/L,表明增加膜池硝化回流液固液分离装置显著改善了A2/O-MBR系统的脱氮除磷效果。反硝化除磷活性实验结果进一步表明,改进后系统中反硝化除磷活性占总除磷活性的比例由51.5%上升至61.7%,说明增加膜池硝化回流液固液分离装置强化了系统的反硝化除磷性能。  相似文献   

5.
微絮凝 -直接过滤工艺是一种将混凝反应、沉淀截留集中在同一滤柱内同步完成的高效水处理工艺。该工艺应用于城市污水的深度处理中 ,通过絮凝剂的加入 ,具有同步去除PO3 -4 P、SS和部分COD的功能。本文研究了该工艺对二级处理出水中PO3 -4 P、SS和COD的去除效果及其规律。研究表明 :采用聚合氯化铁 (PFC)作为絮凝剂 ,当Fe/P摩尔比为 2∶1时 ,水中PO3 -4 P的去除率达 98.8% ,浓度可降至 0 .1mg/L以下 ,同时SS、COD去除率也有明显提高。与传统的混凝、沉淀除磷工艺相比 ,该工艺具有操作简单、结构紧凑、占地面积小、污泥量少等优点 ,是一种更为经济和简单的处理单元 ,适用于现有城市污水处理厂的除磷和进一步提高水质的深度处理  相似文献   

6.
改良型A2/O-MBR工艺的反硝化除磷性能研究   总被引:2,自引:0,他引:2  
重点考察了一种改良型膜生物反应器(A2/O-MBR)的脱氮除磷性能。该工艺主要特点在于对膜池硝化回流液进行了固液分离,并将上清液和浓缩污泥分别回流至缺氧池和厌氧池,这种改进提高了系统对氮、磷的同步去除效率。实验结果表明,在水力停留时间(HRT)为12 h,污泥龄(SRT)为30 d,混合液回流比为200%的运行条件下,进水COD、NH4+-N、TN和TP平均浓度分别为(225±38)、(24.8±3.9)、(26.7±2.9)和(2.90±0.53)mg/L时,增加膜池硝化回流液固液分离装置前后,系统对COD和NH4+-N的去除都维持在较高水平,而系统对TN和TP的去除效果显著提高,出水TN和TP平均浓度分别由(14.9±3.3)mg/L和(1.95±0.72)mg/L下降到(9.4± 1.9)mg/L和(0.91±0.38)mg/L,表明增加膜池硝化回流液固液分离装置显著改善了A2/O-MBR系统的脱氮除磷效果。反硝化除磷活性实验结果进一步表明,改进后系统中反硝化除磷活性占总除磷活性的比例由51.5%上升至61.7%,说明增加膜池硝化回流液固液分离装置强化了系统的反硝化除磷性能。  相似文献   

7.
The phosphate fertilizer industry produces highly hazardous and acidic wastewaters. This study was undertaken to develop an integrated approach for the treatment of wastewaters from the phosphate industry. Effluent samples were collected from a local phosphate fertilizer producer and were characterized by their high fluoride and phosphate content. First, the samples were pretreated by precipitation of phosphate and fluoride ions using hydrated lime. The resulting low- fluoride and phosphorus effluent was then treated with the enhanced biological phosphorus removal (EBPR) process to monitor the simultaneous removal of carbon, nitrogen, and phosphorus. Phosphorus removal included a two-stage anaerobic/aerobic system operating under continuous flow. Pretreated wastewater was added to the activated sludge and operated for 160 days in the reactor. The operating strategy included increasing the organic loading rate (OLR) from 0.3 to 1.2 g chemical oxygen demand (COD)/L.d. The stable and high removal rates of COD, NH4(+)-N, and PO4(3-)-P were then recorded. The mean concentrations of the influent were approximately 3600 mg COD/L, 60 mg N/L, and 14 mg P/L, which corresponded to removal efficiencies of approximately 98%, 86%, and 92%, respectively.  相似文献   

8.
利用亚硝酸盐为电子受体反硝化聚磷菌的筛选与富集   总被引:1,自引:0,他引:1  
依据DPB原理,利用SBR动态反应器和静态释/聚磷装置.以A2/O工艺厌氧段污泥为种泥,研究以亚硝酸盐为电子受体反硝化聚磷菌的筛选与富集,同时对选择、富集污泥的反硝化聚磷性能进行了考察.结果表明:利用亚硝酸盐为电子受体的反硝化聚磷菌存在于A2/O厌氧段污泥中,通过厌氧/好氧和厌氧/缺氧方式运行后,聚磷菌总数由1400个/mL增加到32 000个/mL,其中反硝化聚磷菌占聚磷菌总数的比例也由14.5%提高到81%,磷酸盐和亚硝酸盐去除率分别由最初的8.65%和7.55%上升到91%和95.62%;筛选与富集利用亚硝酸盐为电子受体的反硝化聚磷菌时,缺氧段进水COD的浓度须控制在10 mg/L以下;当体系处于稳定状态,且亚硝酸盐氮浓度高达30 mg/L时,并未对反硝化聚磷菌的生存产生抑制和体系运行产生干扰,此时磷酸盐出水低至1.06 mg/L.  相似文献   

9.
针对榨菜腌制废水高盐高氮磷高有机物浓度的特征,提出"厌氧序批式生物膜反应器(ASBBR)-二级序批式生物膜反应器(SBBR)-化学除磷"组合处理工艺,在前期对组合工艺中单元工艺的关键工况参数研究的基础上,考察组合工艺的处理效能。实验结果表明,采用该组合工艺,可使进水COD、NH4+-N、TN及PO43--P分别为10 000、345、550和38.5mg/L的榨菜腌制废水,处理出水COD、NH4+-N、TN及PO43--P分别达到93.6、12.3、18和0.1 mg/L,去除率分别为99.1%、96.4%、96.7%和99.9%,出水达到污水综合排放一级标准。  相似文献   

10.
The aim of this study was to expand the International Water Association Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate-accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic conditions. The Gdansk (Poland) wastewater treatment plant (WWTP), which has a modified University of Cape Town (MUCT) process for nutrient removal, provided field data and mixed liquor for batch tests for model evaluation. The original ASM2d was first calibrated under dynamic conditions with the results of batch tests with settled wastewater and mixed liquor, in which nitrate-uptake rates, phosphorus-release rates, and anoxic phosphorus uptake rates were followed. Model validation was conducted with data from a 96-hour measurement campaign in the full-scale WWTP. The results of similar batch tests with ethanol and fusel oil as the external carbon sources were used to adjust kinetic and stoichiometric coefficients in the expanded ASM2d. Both models were compared based on their predictions of the effect of adding supplemental carbon to the anoxic zone of an MUCT process. In comparison with the ASM2d, the new model better predicted the anoxic behaviors of carbonaceous oxygen demand, nitrate-nitrogen (NO3-N), and phosphorous (PO4-P) in batch experiments with ethanol and fusel oil. However, when simulating ethanol addition to the anoxic zone of a full-scale biological nutrient removal facility, both models predicted similar effluent NO3-N concentrations (6.6 to 6.9 g N/m3). For the particular application, effective enhanced biological phosphorus removal was predicted by both models with external carbon addition but, for the new model, the effluent PO4-P concentration was approximately one-half of that found from ASM2d. On a PO4-P removal percentage basis, the difference was small, that is, 94.1 vs. 97.1%, respectively, for the ASM2d and expanded ASM2d.  相似文献   

11.
针对反硝化聚磷菌的生物学特性,设计并制作了硝化反硝化除磷气升式环流生物膜反应器,并就其对生活污水的脱氮、脱碳和除磷过程进行了试验.试验结果表明,当进水COD为309.8 mg/L、NH4 -N为116.0 mg/L、PO34-P为10.5 mg/L时,它们的去除率分别为95.3%、94.6%和73.1%.通过间歇试验表明该反应器可以实现反硝化除磷.  相似文献   

12.
研究了分别以葡萄糖和乙酸钠为碳源时多点交替进水阶式A2/O(CMICAO)工艺氮磷的去除效果,以及在不同进水C/N比时各进水量分配对脱氮除磷效果的影响.结果表明,在相同的进水COD浓度下,乙酸钠比葡萄糖更适合作为碳源,更能提高脱氮除磷效率.以葡萄糖为碳源时,COD为200 mg/L、C/N比为5、缺氧池与厌氧池进水配比为1∶2时,出水COD、TN、氨氮和TP浓度分别为28.5、10.8、2.1和0.5 mg/L,均达到国家一级A排放标准.若采用葡萄糖作为碳源,投加量以使进水C/N比为5~7.5为宜,外加碳源时缺氧池与厌氧池进水分配比可统一采用1∶1.  相似文献   

13.
以桂林市第四污水处理厂氧化沟活性污泥为对象,研究在具有厌氧-缺氧-好氧环境的污水处理构筑物中富集存在的反硝化聚磷菌聚磷能力的持久性问题。结果表明,在此环境中富集的反硝化聚磷菌在经过3个周期的厌氧-缺氧条件下运行,最大释磷率由0.90 mg P/(g VSS.h)下降为0.07 mg P/(g VSS.h),反硝化聚磷率由0.17 mg P/(g VSS.h)下降为0.04 mg P/(g VSS.h)。比较而言,在厌氧-缺氧-好氧环境下最大释磷率及聚磷率降幅较小,释磷率由0.59 mg P/(gVSS.h)下降为0.37 mg P/(g VSS.h),反硝化聚磷率由0.17 mg P/(g VSS.h)下降为0.10 mg P/(g VSS.h),厌氧-缺氧-好氧运行条件比单纯的厌氧-缺氧运行条件更有利于维持反硝化聚磷菌的聚磷性能。  相似文献   

14.
按20%的投配比往好氧1,2池中加入相同数量的悬浮式填料,将传统A2/O工艺转变为A2/O-MBR复合工艺。通过处理实际市政污水,重点考察了在缺氧池中不同填料投配比条件下,复合工艺的去除效果以及反硝化除磷效果。实验结果表明,当缺氧池中填料投配比为20%时,装置总体的处理效果最好。COD、总氮、氨氮和总磷的去除率分别达到了81.1%、80.3%、100%和85.2%。当投配比为10%时,反硝化除磷效果最明显,占总除磷量的48.3%。从经济角度出发,10%的投配比为最佳投配比。  相似文献   

15.
在改良型氧化沟工艺的循环廊道内增设缓流板,以此改变循环廊道过流断面面积,进而调控循环比(循环廊道断面通过的循环流量和进水流量的比值)。利用胞内、胞外聚合物的分析及物料平衡的方法,研究了增设缓流板、调控循环比前后系统同步脱氮除磷效果和磷转化途径的变化及聚磷菌种含量的差别。结果表明,增设缓流板,循环比为27时,COD、NH+4、TN和TP的平均去除率分别为93.3%、87.1%、78.1%和96.0%,反硝化聚磷菌占总聚磷菌的比例为46.1%;而不设缓流板,循环比为241时,COD、NH+4、TN和TP的平均去除率分别为91.2%、82.7%、67.2%和86.4%,反硝化聚磷菌占总聚磷菌的比例为17.54%。综上可知,增设缓流板控制循环比,有助于提高反硝化聚磷菌的富集,有助于提高反硝化吸磷量,同时有助于提高氧化沟工艺的同步脱氮除磷效果。  相似文献   

16.
A2/O工艺中的反硝化除磷   总被引:7,自引:2,他引:5  
A2/O工艺是一种最简单的同步脱氮除磷工艺,但由于其系统中固有的基质竞争和污泥龄等矛盾,在实际应用中特别是处理低C/N比污水时脱氮除磷效率较低.反硝化除磷工艺作为近年来颇受关注的污水生物处理新技术.由于在脱氮除磷过程中可以在碳源利用上耦合,可从一定程度上缓解A2/O工艺中的基质竞争矛盾,使得其在处理低C/N比污水时也能实现较高的脱氮除磷效率.就反硝化除磷的技术原理,结合其在A2/O工艺中的最新研究成果及其控制策略,对A2/O工艺中的反硝化除磷的实现、维持及影响因素进行了分析和探讨,并对其发展方向进行了展望.  相似文献   

17.
在分析传统A2/O工艺缺陷的基础上,提出了一种改进型A2/O工艺。为了防止回流污泥中的硝酸盐进入厌氧区,在传统A2/O工艺的厌氧区后面增加一个体积较小的缺氧选择池,回流污泥进入缺氧选择池,并进行反硝化消耗回流污泥中的硝酸盐;同时,在缺氧区通过反硝化除磷实现"一碳两用"。结果表明,改进型A2/O工艺有较好的脱氮除磷效果,在COD为298mg/L、TN为55mg/L左右、TP为7mg/L左右时,系统对COD、TN、TP的平均去除率分别为88.44%、77%、95%。  相似文献   

18.
不同形态铁盐的除磷效果   总被引:2,自引:2,他引:0  
研究不同铁盐存在形态的铁盐类混凝剂,即三氯化铁(离子态铁)、聚合氯化铁(聚合态铁)和氢氧化铁(凝胶态铁),在混凝除磷性能方面的差异。以城市污水厂的二级出水为实验水样,进行混凝除磷性能研究。结果表明,二级出水总磷为1.74 mg/L,离子态铁投加量为40 mg/L时,对总磷的去除率为90%,混凝处理后上清液总磷可达《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级A标准,聚合态铁对总磷的去除率为62%,凝胶态氢氧化铁的总磷去除率为59%,混凝处理后上清液总磷均不能满足GB18918-2002中的一级A标准。离子态氯化铁对污水厂二级出水的除磷效果优于聚合态,即铁离子的聚合形态会影响其除磷效果。  相似文献   

19.
改良型一体化氧化沟工艺在低碳源条件下脱氮除磷   总被引:4,自引:0,他引:4  
王涛  何怡  郎建  刘霞  白洁颖 《环境工程学报》2012,6(5):1489-1494
针对在低碳源条件下脱氮除磷效果不佳,将倒置A2/O工艺的思想运用于一体化氧化沟工艺中,构建一种新型污水处理系统,即改良型一体化氧化沟工艺。实验考查了系统在低碳源条件下的脱氮除磷能力;结果表明:当缺氧区进水分配比r=0.8,泥龄SRT=10 d,好氧区水力停留时间HRT=12 h时,该系统对COD、NH4+-N和TP的去除率分别达70.8%、89.3%和72.1%,出水NOx--N为1.65 mg/L,同时处理效果稳定,出水水质达到了《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级B标准的要求。  相似文献   

20.
以实际生活污水为处理对象,考察了传统进水/曝气和改良型分段进水的交替缺氧-好氧(A/O)2种运行模式对CAST工艺的快速启动及脱氮除磷性能稳定维持的影响。结果表明,传统进水/曝气运行模式下,系统达到最佳营养物去除性能所需启动时间30 d,稳定运行阶段TN平均去除80.66%,磷的去除率维持在66.30%左右;采用改良型交替运行模式,反应器达到稳定运行状态仅需18 d,系统稳定运行时TN平均去除81.36%,磷去除率稳定维持在90%以上,出水磷浓度在0.3 mg/L以下,出水水质达到国家污水综合排放标准一级A(GB8978-2002)。研究还发现,传统运行模式下,由低温引起的污泥沉降性能变差导致系统污泥严重流失,反应器几乎丧失污染物去除性能;而低温对交替运行模式下的反应器除磷性能几乎没有影响,总氮去除则因氨氮不完全硝化而大大降低。  相似文献   