贵阳室内氡时空分布特征研究   总被引:1,自引:0,他引:1  
为了全面分析室内氡的时空分布特征、来源和影响因素,选择了贵阳市不同地理位置的居民住宅、办公场所和公共场所,进行了为期一年的室内氡监测。贵阳市室内氡的平均浓度为(72.7±1.6)Bq/m3,低于室内空气污染国家标准,达标率98.5%。其中居民住宅、办公场所和公共场所的室内氡浓度分别为(93.46±86.93)、(74.68±40.74)、(61±26.93)Bq/m3。研究表明,室内涂料、装修程度和通风效果、小区环境等对室内氡浓度高低有显著影响,室内氡也随季节变化而发生波动。对于居民住宅和公共场所氡的室内外来源相对重要性不同。居民住宅内新楼和旧楼不同楼层室内氡的来源、影响因素和分布特征有显著差异。  相似文献   

2.
The province of Batman, located in southern Anatolia, has a population of approximately 500,000. To our knowledge, there exists no information regarding the environmental radioactivity in this province. Therefore, gamma activity measurements in soil, building materials and water samples and an indoor radon survey have been carried out in the Batman province. The mean activity concentrations of the natural radionuclides (226Ra, 232Th and 40K) and a fission product (137Cs) were 35 ± 8, 25 ± 10, 274 ± 167 and 12 ± 7 Bq kg???1, respectively, in the soil samples. The concentrations of 226Ra, 232Th and 40K in the selected building materials ranged from 18 to 48 Bq kg???1, 8 to 49 Bq kg???1 and 68 to 477 Bq kg???1, respectively. All the calculated radium equivalent (Raeq) activity values of the building material samples are lower than the limit of 370 Bq kg???1, equivalent to a γ-dose of 1.5 mSv year???1. The activity concentrations of 226Ra, 232Th and 40K in tap waters collected from the study area were determined with mean specific activity concentrations of 42 ± 15, 35 ± 9 and 524 ± 190 mBq L???1, respectively. Indoor radon measurements were made at 95 dwellings in Batman using a CR-39 detector. The radon concentration levels were found to vary from 23 to 145 Bq m???3. The arithmetic mean of the measured radon concentration levels was found to be 84 Bq m???3 with a standard deviation value of 23 Bq m???3. The measurement results obtained in this study did not significantly differ from those taken in other parts of the country. The data generated in this study can be used to determine whether the Batman province is in a normal or high background radiation area and provides a valuable database for future estimations of the impact of radioactive pollution.  相似文献   

3.
Environmental monitoring and indoor radon measurement are important for public health, to estimate the cancer risk of respiratory system and, if necessary, to suggest proper methods that reduce indoor radon level. In this research, indoor radon concentration in the air has been measured in 150 apartments in Mashhad city. The result demonstrates about 94.7% of apartments have radon concentration less than 100 Bq/m3, taken by WHO as the action level, and 5.3% have the concentration higher than this level. As well as, annual radon dose has been assessed using the equation for annual effective dose calculation introduced by United Nations Scientific Committee on the Effects of Atomic Radiation.  相似文献   

4.
It is well established that some areas of Himachal Pradesh (H.P.) state of India situated in the environs of the Himalayan mountains are relatively rich in uranium-bearing minerals. Some earlier studies by our group have indicated high levels of radon (>200 Bq m(-3)) in the dwellings. It is in this context that an indoor radon/thoron survey has been carried out in selected villages of four districts in the state of H.P. This survey has been conducted as a part of a national, coordinated project using twin chamber dosemeter cups designed by the Environmental Assessment Division (EAD), Department of Atomic Energy, Govt. of India. The track-etch technique is used for calibration of plastic detector LR-115 type-II which are employed for recording alpha tracks due to radon/thoron and their daughters. Year long radon/thoron data have been collected for seasonal correlations of indoor radon/thoron in the dwellings. The indoor radon levels have been found to vary from a minimum value of 17.4 Bq m(-3) to a maximum value of 140.3 Bq m(-3). The indoor thoron levels vary from a minimum value of 5.2 Bq m(-3) to a maximum value of 131.9 Bq m(-3). The year average dose rate for the local population varies from 0.03 microSv h(-1) to 0.83 microSv h(-1). The annual exposure dose to inhabitants in all the dwellings lies below the upper limit of 10 mSv given in ICRP-65.  相似文献   

5.
The paper presents the results of radon concentration measurements in the vicinity of water, indoor air and in contact to building walls. The investigations were carried out using CR-39 track detectors. Samples of ground water flowing out of many springs mostly in Arabian Gulf area except one from Germany have been studied. The results are compared with international recommendations and the values are found to be lower than the recommended value. Measuring the mean indoor radon concentrations in air and in contact to building walls in the dwellings of Kuwait University Campus were found 24.2 +/- 7.7, and 462 +/- 422 Bq m(-3) respectively. These values lead to average effective dose equivalent rates of 1.3 +/- 0.4 and 23 +/- 21 mSv year(-1), respectively.  相似文献   

6.
The results of measurements of Krypton-85 (85Kr) concentrations in the ground-level air of Prague between 1983 and 1992 are presented and time-related changes analysed. The long-term trend in activity level of 85Kr has been steadily increasing with a growth rate of 0.04 Bq.m–3 (STP) per year. Some peaks of 85Kr activity were observed due to the influence of undispersed radioactive plumes coming from distant sources. Short-term variations within a typical range of concentrations from 0.61 to 1.25 Bq.m–3 (STP) were found to be seasonally dependent, with the maximum occurring in spring.  相似文献   

7.
The present study was done in the Fen Complex, a Norwegian area rich in naturally occurring radionuclides, especially in thorium ((232)Th). Measurement of radioactivity levels was conducted at the decommissioned iron (Fe) and niobium (Nb) mining sites (TENORM) as well as at the undisturbed wooded sites (NORM), all open for free public access. The soil activity concentrations of (232)Th (3280-8395 Bq kg(-1)) were significantly higher than the world and the Norwegian average values and exceeded the Norwegian screening level (1000 Bq kg(-1)) for radioactive waste, while radium ((226)Ra) was present at slightly elevated levels (89-171 Bq kg(-1)). Terrestrial gamma dose rates were also elevated, ranging 2.6-4.4 μGy h(-1). Based on long-term surveys, the air concentrations of thoron ((220)Rn) and radon ((222)Rn) reached 1786 and 82 Bq m(-3), respectively. Seasonal variation in the outdoor gamma dose rates and Rn concentrations was confirmed. Correlation analyses showed a linear relationship between air radiation levels and the abundance of (232)Th in soil. The annual outdoor effective radiation doses for humans (occupancy 5 h day(-1)) were estimated to be in the range of 3.0-7.7 mSv, comparable or higher than the total average (summarized indoor and outdoor) exposure dose for the Norwegian population (2.9 mSv year(-1)). On the basis of all obtained results, this Norwegian area should be considered as enhanced natural radiation area (ENRA).  相似文献   

8.
根据重庆市城市组团式建设特点,采用径迹法对重庆市主城建成区开展室内氡浓度调查。结果表明,各区县室内氡浓度整体水平较低,重庆市主城区室内氡浓度平均值为64.5 Bq/m3,168个采样点均小于国家标准200 Bq/m3;吸入氡及子体对人员产生的年均有效剂量均低于《住房内氡浓度控制标准》和《地下建筑氡及其子体控制标准规定》中规定的室内氡浓度行动水平。  相似文献   

9.
Results of systematic, long-term measurements of 137Cs activities in wheat for the period 1965–2003 are summarized. Radiocaesum fallout activities affect wheat activity concentrations, the coefficient of correlation being 0.91. In the observed period, the highest activity of 137Cs deposited by fallout, 6321 Bq m−2, was recorded in 1986, i.e., in the year of Chernobyl accident, causing peak 137Cs activity concentration in wheat of 38.0 ± 13.0 Bq kg−1. After the Chernobyl nuclear accident the 134Cs:137Cs activity ratio in wheat was ≈0.5, and did not differ from the value found in other environmental samples. The transfer coefficient from 137Cs fallout deposition to wheat was calculated to be 8.6 × 10−3 Bq y kg−1 per Bq m−2, indicating the low transfer of radiocaesium from fallout to wheat. The upper limit for the collective effective dose for the Croatian population due to 137Cs and 134Cs ingestion by wheat and wheat products consumption for period 1965–2003 was estimated to be 665 person-Sv, the upper limit for the annual collective effective dose in 2003 being only about 0.061 person-Sv.  相似文献   

10.
Radon and thoron, and their progeny concentrations along with equilibrium factors for gas progeny and radiological risks to the residents have been measured in dwellings of Digboi and Mashimpur areas located on anticlines during the winter season. In this present investigation, twin-cup dosemeters fitted with LR-115 (II) nuclear detectors have been employed. The present work has shown that there exist considerable house-to-house variations in values with maximum values in mud houses and minimum values in assam type (AT) houses. It has been found that mean (and geometric standard deviations (GSD)) radon concentrations are 83.8 (1.3), 113.5 (1.1) and 157.2 (1.2) Bq m?3 in AT, reinforced cement concrete (RCC) and mud houses in Digboi area and 63.0 (1.1), 87.1 (1.4) and 182.1 (1.2) Bq m?3 in AT, RCC and mud houses in Mashimpur area, respectively. The overall mean radon concentrations in Digboi and Mashimpur are estimated to be 114.4 (1.4) and 100.0 (1.7) Bq m?3. The mean radon concentrations are found to be less than the lower reference level of 200 Bq m?3 of the International Commission on Radiological Protection (ICRP 2007). The thoron concentrations in Digboi area are estimated to be 31.1 (1.3), 50.8 (1.4) and 67.0 (1.6) Bq m?3 in AT, RCC and mud houses, respectively, whereas in Mashimpur area, the thoron concentrations are estimated to be 26.4 (1.3), 44.4 (1.3) and 77.7 (1.3) Bq m?3 in AT, RCC and mud houses, respectively. The mean annual effective doses in Digboi area are found to be 1.9 (1.3), 2.7 (1.2) and 4.1 (1.4) mSv y?1 in AT, RCC and mud houses, respectively, while in the case of Mashimpur area, the mean annual effective doses are found to be 1.5 (1.4), 2.2 (1.2) and 4.9 (1.3) mSv y?1 in AT, RCC and mud houses, respectively. Nevertheless, the obtained results are much lower than the upper reference level of 10 mSv (ICRP 2007).  相似文献   

11.
The aims of the present study were to determine the levels of bioaerosols including airborne culturable bacteria (total suspended bacteria, Gram-positive bacteria, Staphylococcus, Staphylococcus aureus, methicillin-resistant S. aureus (MRSA), and Gram-negative bacteria), fungi, endotoxin, and viruses (influenza A, influenza B, respiratory syncytial virus types A/B, parainfluenza virus types 1/2/3, metapnemovirus, and adenovirus) and their seasonal variations in indoor air of residential apartments. Of the total suspended bacteria cultured in an indoor environment, Staphylococcus was dominant and occupied 49.0 to 61.3 % of indoor air. Among Staphylococcus, S. aureus were detected in 100 % of households' indoor air ranging from 4 to 140 CFU/m3, and 66 % of households were positive for MRSA ranging from 2 to 80 CFU/m3. Staphylococcus and S. aureus concentrations correlated with indoor temperature (adjusted β: 0.4440 and 0.403, p?<?0.0001). Among respiratory viruses, adenovirus was detected in 14 (14 %) samples and influenza A virus was detected in 3 (3 %) samples regarding the indoor air of apartments. Adenovirus concentrations were generally higher in winter (mean concentration was 2,106 copies/m3) than in spring (mean concentration was 173 copies/m3), with concentrations ranging between 12 and 560 copies/m3. Also, a strong negative correlation between adenovirus concentrations and relative humidity in indoor air was observed (r?=??0.808, p?<?0.01). Furthermore, temperature also negatively correlated with adenovirus concentrations (r?=??0.559, p?<?0.05).  相似文献   

12.
The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.  相似文献   

13.
In this work, a numerical model is proposed to estimate air concentration of released airborne radioactive contaminants 131I and 137Cs. A Gaussian dispersion model is used to assess the atmospheric dispersion of radioactive contaminants released continuously from a nuclear power plant as a result of an accident. The model uses various input parameters such as source height, release rate, stability class, wind speed, and wind direction. The validation of the model was carried out by comparing its predicted values with published experimental data. The model was extensively tested by simulating several accidental situations. The main conclusion drawn from these tests is that for large downwind distances from the release point, the contaminant concentrations predicted by the model diverge drastically from measured data, while for short distances, the predicted values generally agree quite well with experimental data. The obtained activity concentrations range from 1.57?×?102 to 6.43?×?103 Bq/m3 for 131I and from 3.18?×?10?2 to 9.72?×?102 Bq/m3 for 137Cs. The estimated standard deviation coefficients values range of 7.2 to 6847.7 m, and the maximum absolute error predicted by the model for these parameters was less than 5%.  相似文献   

14.
To obtain information on the spatial variability of fallout 137Cs in the soil of a small area, the activity concentration of this radionuclide was determined in 100 soil samples, taken along the two diagonals of a cultivated field (150×100 m). The results show that the spatial distribution of 137Cs in this field is at random. The frequency distribution of the values is skewed to the right, but not log-normal. The median activity concentration observed was 7.45 Bq kg-1 dry soil, the values ranging from 4.8–15 Bq kg-1. The spatial variability, as characterized by the relative decile deviation was 26%. If one tolerates for the establishment of baselines of global fallout 137Cs in the soil an error in the mean activity concentration of 10% (20%) at the 95% confidence level, the minimum number of soil samples to be taken can be estimated as 14 (4). The total deposition of 137Cs on the soil surface by fallout was determined as 3.3±0.4 kBq m-2.  相似文献   

15.
This study measures the effect of emissions from an airport on the air quality of surrounding neighborhoods. The ambient concentrations of benzene, toluene, ethylbenzene, and o-, m-, and p-xylene (BTEX) were measured using passive samplers at 15 households located close to the airport (indoor, outdoor, and personal), at the end of airport runways and an out-of-neighborhood location. Measurements occurred over a 48-h period during summer 2006 and winter 2006?C2007. The average concentrations were 0.84, 3.21, 0.30, 0.99, and 0.34 ??g/m3 at the airport runways and 0.84, 3.76, 0.39, 1.22, and 0.39 ??g/m3 in the neighborhood for benzene, toluene, ethylbenzene, m-, p-, and o-xylene. The average neighborhood concentrations were not significantly different to those measured at the airport runways and were higher than the out-of-neighborhood location (0.48, 1.09, 0.15, 0.78, and 0.43 ??g/m3, each BTEX). B/T ratios were used as a tracer for emission sources and the average B/T ratio at the airport and outdoors were 0.20 and 0.23 for the summer and 0.40 and 0.42 for the winter, suggesting that both areas are affected by the same emission source. Personal exposure was closely related to levels in the indoor environment where subjects spent most of their time. Indoor/outdoor (I/O) ratios for BTEX ranged from 1.13 to 2.60 and 1.41 to 3.02 for summer and winter. The seasonal differences in I/O ratios reflected residential ventilation patterns, resulting in increased indoor concentrations of volatile organic compounds during winter.  相似文献   

16.
Ozone concentrations were measured in Zagreb at four sites from May 1999 to April 2001 in order to categorize the air quality with respect to ozone. In the summer of 2000, the ozone measurements were also extended to four sites in the suburbs of Zagreb. Methods of active and passive sampling with nitrite ion as a reagent were used. In the northern part of the town ozone was analyzed by an automatic device. Automatic device measurements in the years 1999 and 2000 showed that hourly averages of ozone concentrations did not exceed the Croatian recommended value of the 98th percentile (180 g m–3). Over the two-year period, 24-h averages occasionally exceed 110 g m–3 in city center and in the northern part of the town. Regardless of these isolated examples, ozone was well within acceptable concentrations. Ozone concentrations measured in summer 2000 were higher in the suburbs of Zagreb than in the city. The 98th percentile values higher than 110 g m–3 were recorded at three sites.  相似文献   

17.
Concentrations of outdoor radon-222 (222Rn) in temperate grazed peatland and deciduous forest in northwestern Turkey were measured, compared, and modeled using artificial neural networks (ANNs) and multiple nonlinear regression (MNLR) models. The best-performing multilayer perceptron model selected out of 28 ANNs considerably enhanced accuracy metrics in emulating 222Rn concentrations relative to the MNLR model. The two ecosystems had similar diel patterns with the lowest 222Rn concentrations in the afternoon and the highest ones near dawn. Mean level (5.1?+?2.5 Bq?m?3 h?1) of 222Rn in the forest was three times smaller than that (15.8?+?9.7 Bq?m?3) of 222Rn in the peatland. Mean 222Rn level had negative and positive relationships with air temperature and relative humidity, respectively.  相似文献   

18.
In this study, dry season radon flux densities and radon fluxes have been determined at the rehabilitated Nabarlek uranium mine in northern Australia using conventional charcoal canisters. Environmental background levels amounted to 31± 15 milli Becquerel per m2 per second (mBq m−2 s−1). Radon flux densities within the fenced rehabilitated mine area showed large variations with a maximum of 6500 mBq m−2 s−1 at an area south of the former pit characterised by a disequilibrium between 226Ra and 238U. Radon flux densities were also high above the areas of the former pit (mean 971 mBq m−2 s−1) and waste rock dump (mean 335 mBq m−2 s−1). The lower limit for the total pre-mining radon flux from the fenced area (140 ha) was estimated to 214 kBq s−1, post-mining radon flux amounted to 174 kBq s−1.Our study highlights that the results of radon flux studies are vitally dependant on the selection of individual survey points. We suggest the use of a randomised system for both the selection of survey points and the placement of charcoal canisters at each survey point, to avoid over estimation of radon flux densities. It is also important to emphasize the significance of having reliable pre-mining radiological data available to assess the success of rehabilitation of a uranium mine site.2006 Springer. The Australian Government's right to retain a non-exclusive, royalty free licence in and to any copyright is acknowledged.  相似文献   

19.
Simultaneous indoor and outdoor PM10 and PM2.5 concentration measurements were conducted in seven primary schools in the Athens area. Both gravimetric samplers and continuous monitors were used. Filters were subsequently analyzed for anion species. Moreover ultrafine particles number concentration was monitored continuously indoors and outdoors. Mean 8-hr PM10 concentration was measured equal to 229 ± 182 μg/m3 indoors and 166 ± 133 μg/m3 outdoors. The respective PM2.5 concentrations were 82 ± 56 μg/m3 indoors and 56 ± 26 μg/m3 outdoors. Ultrafine particles 8-h mean number concentration was measured equal to 24,000 ± 17,900 particles/cm3 indoors and 32,000 ± 14,200 particles/cm3 outdoors. PM10 outdoor concentrations exhibited a greater spatial variability than the corresponding PM2.5 ones. I/O ratios were close or above 1.00 for PM10 and PM2.5 and smaller than 1.00 for ultrafine particles. Very high I/O ratios were observed when intense activities took place. The initial results of the chemical analysis showed that accounts for the 6.6 ± 3.5% of the PM10 and for the 3.1 ± 1.4%.The corresponding results for PM2.5 are 12.0 ± 7.7% for and 3.1 ± 1.9% for . PM2.5 indoor concentrations were highly correlated with outdoor ones and the regression line had the largest slope and a very low intercept, indicative of no indoor sources of fine particulate . The results of the statistical analysis of indoor and outdoor concentration data support the use of as a proper surrogate for indoor PM of outdoor origin.  相似文献   

20.
Air pollution in the workplace environment due to industrial operation have been found to cause serious occupational health hazard. Similarly, heat stress is still most neglected occupational hazard in the tropical and subtropical countries like India. The hot climate augments the heat exposure close to sources like furnaces. In this study an attempt is made to assess air pollution and heat exposure levels to workers in the workplace environment in glass manufacturing unit located in the State of Gujarat, India. Samples for workplace air quality were collected for SPM, SO2, NO2 and CO2 at eight locations. Results of workplace air quality showed 8-hourly average concentrations of SPM: 165–9118 μg/m3, SO2: 6–9 μg/m3 and NO2: 5–42 μg/m3, which were below the threshold limit values of workplace environment. The level of CO2 in workplace air of the plant was found to be in the range 827–2886 μg/m3, which was below TLV but much higher than the normal concentration for CO2 in the air (585 mg/m3). Indoor heat exposure was studied near the furnace and at various locations in an industrial complex for glass manufacturing. The heat exposure parameters including the air temperature, the wet bulb temperature, and the globe parameters were measured. The Wet Bulb Globe Temperature (WBGT), an indicator of heat, exceeded ACGIH TLVs limits most of the time at all the locations in workplace areas. The recommended duration of work and rest have also been estimated.  相似文献   