首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
Ozonation of three different synthetic pharmaceutical formulation wastewater containing two human antibiotics and a veterinary antibiotic has been studied to enhance the their biodegradability. The effects of pH and initial chemical oxygen demand (COD) value as well as addition of hydrogen peroxide on ozonation process were investigated. Total organic carbon (TOC), COD, biochemical oxygen demand (BOD), and aromatic content (UV254) were the parameters followed to evaluate the performance of ozonation process. Comparison of the biodegradability of selected wastewaters containing different antibiotics confirmed that the variation of biodegradability was associated with the target compound. While BOD5/COD ratio of veterinary antibiotic formulation wastewater was increased from 0.077 to 0.38 with an applied ozone dosage of 2.96 g/l, this ratio for human antibiotic I and human antibiotic II was increased from 0 to 0.1 and 0.27 respectively. Moreover the results of this investigation showed that the ozonation process is capable of achieving high levels of COD and aromaticity removals at about their natural pH values.  相似文献   

2.
The photo-Fenton reaction effect on the biodegradability improvement of 100 mg/L solution of 2,4-dichlorophenol (DCP) has been investigated. Biochemical oxygen demand (BOD) at 5 and 21 days, BODn/ chemical oxygen demand (COD) and BODn/total organic carbon (TOC) ratios, average oxidation state, and inhibition on activated sludge were monitored. For 50 mg/L hydrogen peroxide and 10 mg/L iron(II) initial concentrations and 40 minutes of reaction time in the photo-Fenton process, the biodegradability of the pretreated solution, measured as BOD5/COD ratio, was improved from 0 for the original DCP solution up to 0.18 (BOD21/COD = 0.24). At that point, all DCP was eliminated from the solution. To study the effect of the pretreatment step, the biological oxidation of pretreated solutions was tested in two semicontinuous stirred tank reactors, one operated with activated sludge and one with biomass acclimated to phenol. Results showed that more than 80% TOC removal could be obtained by codigestion of the pretreated solution with municipal wastewater. Total organic carbon removals of approximately 60% were also obtained when the sole carbon source for the aerobic reactors was the pretreated solution. The hydraulic retention times used in the bioreactors were of the same order of magnitude as those used at domestic wastewater treatment plants (i.e., between 12 and 24 hours). Kinetic studies based on pseudo-first-order kinetics have also been carried out. Constants were found to be in range 0.67 to 1.7 L x g total volatiles suspended solids(-1) x h(-1).  相似文献   

3.
研究了UV/Fenton技术对高浓度金属清洗乳化油废水的处理效果,考察了亚铁与双氧水浓度、pH、反应时间和搅拌对COD去除效果的影响。实验结果表明,UV/Fenton技术对高浓度乳化油废水(COD平均浓度为35 000 mg/L)具有较高的去除效果,最佳工艺条件为:亚铁与双氧水浓度分别为2 400 mg/L和6 000 mg/L,pH为3,经过2 h反应,COD可降低至1 050 mg/L,去除率为97%。搅拌会降低COD的去除率。研究表明,UV/Fenton技术对高浓度乳化油废水具有很好的降解效果,且药品消耗较低,为目前此类高浓度有机废水的处理提供了技术参考。  相似文献   

4.
研究采用H2O2/Fe^3+催化氧化处理高浓度含甲醛废水,探讨了双氧水和催化剂投加量、反应pH及反应温度等操作条件对处理效果的影响,并通过酸溶解回用失活催化剂。结果表明,较优的操作条件为:H2O2/COD(质量比)=2.2~2.6,Fe^3+/H2O2(摩尔比)=0.048~0.058,反应pH1.80~2.68,反应温度50℃,反应时间40 min;在上述操作条件下,甲醛去除率达到99%以上,COD去除率达到85%以上。失活的催化剂可通过稀酸溶解后循环使用,其效果与三价铁盐作催化剂的基本相同。采用H2O2/Fe^3+处理含甲醛废水具有比采用H2O2/Fe^2+较优的效果。  相似文献   

5.
The aim of our studies was to determine the efficiency of decomposition of non-ionic surfactant by the Fenton method in the presence of iron nanocompounds and to compare it with the classical Fenton method. The subject of studies was water solutions of non-ionic detergent Tergitol TMN-10 used in textile industry. Water solutions of the surfactant were subjected to treatment by the classical Fenton method and to treatment in the presence of iron nanocompounds. In the samples of liquid solutions containing the surfactant, chemical oxygen demand (COD) and total organic carbon (TOC) were determined. The Fenton process was optimized based on studies of the effect of compounds used in the treatment, doses of iron and nanoiron, hydrogen peroxide and pH of the solution on surfactant decomposition. Iron oxide nanopowder catalyzed the process of detergent decomposition, increasing its efficiency and the degree of mineralization. It was found that the efficiency of the surfactant decomposition in the process with the use of iron nanocompounds was by 10 to 30 % higher than that in the classical method. The amounts of formed deposits were also several times smaller.  相似文献   

6.
A mediated Fenton system has been evaluated for decolorization of several types of dyes. The result shows that the Fenton system with a dihydroxybenzoic acid (DHBA) chelator-mediator effectively reduced the color of a diluted solution of Carta Yellow RW liquid, Carta Yellow G liquid, and Cartasol Red 2GF liquid dye to a colorless level after 90 minutes of treatment with 100 microM iron II (Fe[II]), 100 microM DHBA, and 10 mM hydrogen peroxide (H2O2) at room temperature. Our results show that compared to a neat Fenton process, the mediated Fenton decolorization process increased the production, and therefore the effective longevity, of hydroxyl radical (OH) species to increase the decolorization efficiency. Our results suggest that application of this system would also result in an increase in dissolved oxygen (DO) in solution, which in turn would result in reduction of chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total organic carbon (TOC).  相似文献   

7.
通过对含盐化工废水(A)、受潮汐影响的河流水(B)、城市生活污水处理厂排水(C)、采油废水(D)4种不同来源废水进行为期15 d的采样监测,测定了其COD、TOC和Cl^-浓度,分析比较了3种废水指标之间的关系,其中COD分别使用重铬酸钾法、氯气校正法和碘化钾碱性高锰酸钾法3种方法进行测定。实验结果表明,4种废水Cl^-浓度差异较大,盐化工废水A(21749 mg/L)〉采油废水D(7013 mg/L)〉受潮汐影响的河流水B(1807 mg/L)〉城市生活污水处理厂排水C(977 mg/L);在15 d的监测周期内,盐化工废水(A)的TOC波动较大,其余3种废水的TOC浓度基本保持稳定,与Cl^-浓度变化没有直接的关系;4种不同废水的COD与Cl^-浓度之间具有显著的正相关性。通过分析比较表明,碘化钾碱性高锰酸钾法比较适合于盐化工废水(A)和采油废水(D)的测定,氯气校正法比较适合于城市生活污水处理厂排水(C)和采油废水(D)的测定,受潮汐影响的河流水样(B)波动较大,3种方法测得的COD浓度与Cl^-浓度的变化趋势没有显著差异。TOC较适合表征水质有机污染程度。  相似文献   

8.
微波辅助双氧水氧化降解水中磺胺二甲嘧啶   总被引:1,自引:0,他引:1  
赵方  张从良  王岩 《环境工程学报》2012,6(11):4074-4078
采用微波辐照技术辅助双氧水氧化降解水中磺胺二甲嘧啶(SM2),研究了微波辅助双氧水氧化降解水中SM2的影响因素。结果表明,单纯使用微波辐照并不能显著降解SM2,而微波辐照可显著促进双氧水对SM2的氧化作用,提高SM2的降解率。在初始浓度为50 mg/L,微波功率为900 W,加入0.25 mL质量分数为30%的双氧水,pH值为4的条件下辐照6 min,SM2的降解率可达96.5%,COD去除率为72%。  相似文献   

9.
不同来源废水COD、TOC与Cl-的关系   总被引:1,自引:0,他引:1  
通过对含盐化工废水(A)、受潮汐影响的河流水(B)、城市生活污水处理厂排水(C)、采油废水(D)4种不同来源废水进行为期15 d的采样监测,测定了其COD、TOC和Cl-浓度,分析比较了3种废水指标之间的关系,其中COD分别使用重铬酸钾法、氯气校正法和碘化钾碱性高锰酸钾法3种方法进行测定.实验结果表明,4种废水Cl-浓...  相似文献   

10.
Distillery spent-wash has very high organic content (75,000 to 125,000 mg/L chemical-oxygen demand [COD]), color, and contains difficult-to-biodegrade organic compounds. For example, anaerobic treatment of the distillery spent-wash used in this study resulted in 60% COD reduction and low color removal. Subsequent aerobic treatment of the anaerobic effluent resulted in enhancement of COD removal to 66%. In this paper, the effect of ozonation on various properties of the anaerobically treated distillery effluent, including the effect on its subsequent aerobic biodegradation, was investigated. Ozonation of the anaerobically treated distillery effluent at various ozone doses resulted in the reduction of total-organic carbon (TOC), COD, COD/TOC ratio, absorbance, color, and increase in the biochemical-oxygen demand (BOD)/COD ratio of the effluent. Further, ozonation of the anaerobically treated distillery effluent at an ozone dose of 2.08 mg/mg initial TOC and subsequent aerobic biodegradation resulted in 87.4% COD removal, as compared to 66% removal when ozonation was not used.  相似文献   

11.
Oxidation of anthraquinonic dye Acid Blue 62 by electrolysis with conductive-diamond electrodes is studied in this work. COD, TOC, and color have been selected to monitor the degradation of the molecule as a function of several operating inputs (current density, pH, temperature, and NaCl concentration). Results show that the electrochemical oxidation of this model of large molecules follows a first order kinetics in all the conditions assessed, and it does not depend on the pH and temperature. The occurrence of chloride ions in wastewaters increases the rate of color and COD removal as a consequence of the mediated oxidation promoted by the chlorinated oxidizing species. However, chloride occurrence does not have an influence on the mineralization rate. First-order kinetic-constants for color depletion (attack to chromophores groups), oxidation (COD removal), and mineralization (TOC removal) were found to depend on the current density and to increase significantly with its value. A single model was proposed to explain these changes in terms of the mediated oxidation processes. Rate of mineralization remained very close to that expected for a purely mass transfer-controlled process. This was explained assuming that mediated oxidation does not have a significant influence on the mineralization in spite it has some effect on intermediate oxidation stages. The efficiency of the oxidation was found to depend mainly on the concentration of COD being negligible the effect of the other inputs assessed except for the occurrence of chloride ions. Opposite, the efficiency of mineralization depends on concentration of TOC and current density and it did not depend on the chloride occurrence. This observation was found to have an important influence on the power required to remove a given percentage of the initial TOC or COD. To decrease COD efficiently, the occurrence of chloride in the solution is very important, while to remove TOC efficiently, it is more important to work at low current densities and chloride effect is negligible. Energy consumption could be decreased by folds using the proper conditions.  相似文献   

12.
超声-Fenton法处理偶氮染料橙黄II的研究   总被引:1,自引:0,他引:1  
以偶氮染料橙黄II为研究对象 ,考察了Fenton反应在超声辐射条件下 ,pH值、H2 O2 浓度、Fe2 + 离子浓度对COD去除率的影响。实验结果表明 ,超声对Fenton试剂处理偶氮染料橙黄II具有强化作用。超声条件下 ,当染料浓度为10 0mg/L、pH为 3.0、Fe2 + 离子浓度为 10mg/L、H2 O2 浓度为 4 0 0mg/L时 ,反应 90min ,COD去除率最高可达 93%。  相似文献   

13.
通过采用铁碳微电解-Fenton法预处理苯胺基乙腈生产废水的实验研究,分析了处理过程的COD降解动力学;同时研究了单纯活性炭吸附和微电解过程中COD去除率的变化。结果表明,铁碳微电解的初期COD降解过程近似符合一级反应动力学,并且得到微电解与活性炭吸附对铁碳微电解降解COD的关系式;Fenton反应中通过研究有机物浓度和过氧化氢初始浓度与反应进程的关系,建立了反应动力学模型;单纯吸附实验COD去除率在24 h内快速下降,而微电解在相应时间内COD去除率波动较小,为实际应用提供了数据经验和理论依据。  相似文献   

14.
通过采用铁碳微电解-Fenton法预处理苯胺基乙腈生产废水的实验研究,分析了处理过程的COD降解动力学;同时研究了单纯活性炭吸附和微电解过程中COD去除率的变化。结果表明,铁碳微电解的初期COD降解过程近似符合一级反应动力学,并且得到微电解与活性炭吸附对铁碳微电解降解COD的关系式;Fenton反应中通过研究有机物浓度和过氧化氢初始浓度与反应进程的关系,建立了反应动力学模型;单纯吸附实验COD去除率在24h内快速下降,而微电解在相应时间内COD去除率波动较小,为实际应用提供了数据经验和理论依据。  相似文献   

15.
Experimental in situ chemical peroxidation of atrazine in contaminated soil   总被引:4,自引:0,他引:4  
Mecozzi R  Di Palma L  Merli C 《Chemosphere》2006,62(9):1481-1489
Lab-scale experiments of in situ chemical oxidation (ISCO), were performed on soil contaminated with 100 mg kg(-1) of atrazine (CIET). The oxidant used was hydrogen peroxide catalysed by naturally occurring minerals or by soluble Fe(II) sulphate, added in aqueous solution. The oxidation conditions were: CIET:H2O2=1:1100, 2 PV or 3 PV reaction volume, Fe(II):H2O2=0, 1:22, 1:11. Stabilized (with KH2PO4 at a concentration of 16 g l(-1)) or non-stabilized hydrogen peroxide was used. The pH of the reagents was adjusted to pH=1 with sulphuric acid, or was not altered. Results showed that the addition of soluble Fe(II) increased the temperature of the soil slurry and the use of stabilized hydrogen peroxide resulted in a lower heat generation. The treatment reduced the COD of the soil of about 40%, pH was lowered and natural organic matter became less hydrophobic. The highest atrazine conversion (89%) was obtained in the conditions: 3 PV, Fe(II):H2O2=1:11 with stabilized hydrogen peroxide added in two steps. The stabilizer only increased H2O2 life-time significantly when soluble Fe(II) was added. Results indicate as preferential degradation pathway of atrazine in soil dechlorination instead of dealkylation.  相似文献   

16.
Degradation of total phenol (TPh) and organic matter, (expressed as total organic carbon TOC), of a simulated olive mill wastewater was evaluated by the Fenton oxidation process under batch and continuous mode conditions. A mixture of six phenolic acids usually found in these agro-industrial wastewaters was used for this purpose. The study focused on the optimization of key operational parameters of the Fenton process in a batch reactor, namely Fe2+ dosage, hydrogen peroxide concentration, pH, and reaction temperature. On the assessment of the process efficiency, > 99% of TPh and > 56% of TOC removal were attained when [Fe2+] = 100 ppm, [H2O2] = 2.0 g/L, T = 30 °C, and initial pH = 5.0, after 300 min of reaction. Under those operational conditions, experiments on a continuous stirred-tank reactor (CSTR) were performed for different space-time values (τ). TOC and TPh removals of 47.5 and 96.9%, respectively, were reached at steady-state (for τ = 120 min). High removal of COD (> 75%) and BOD5 (> 70%) was achieved for both batch and CSTR optimum conditions; analysis of the BOD5/COD ratio also revealed an increase in the effluent’s biodegradability. Despite the high removal of lumped parameters, the treated effluent did not met the Portuguese legal limits for direct discharge of wastewaters into water bodies, which indicates that coupled chemical-biological process may be the best solution for real olive mill wastewater treatment.  相似文献   

17.
Meinero S  Zerbinati O 《Chemosphere》2006,64(3):386-392
The oxidative efficiency and energy consumption, in the degradation of chloroanilines by anodic oxidation, indirect oxidation with electrogenerated hydrogen peroxide and electro-Fenton have been compared, using a laboratory system driven by a LabVIEW virtual controller. Solutions were oxidized in an undivided cell, where H(2)O(2) was generated electrochemically by reduction of atmospheric oxygen bubbled at a carbon cloth cathode. The electro-Fenton process showed the best degradation power, in terms of efficiency of removal and energy consumption. This process was applied to the purification of a solution obtained by washing a polluted soil. Under laboratory conditions, electro-Fenton removed 75% COD of this wastewater with a specific energy consumption of 0.3kWh per gram of COD, corresponding to 41.8kWhm(-3).  相似文献   

18.
Pre-oxidation and coagulation of textile wastewater by the Fenton process   总被引:30,自引:0,他引:30  
Kang SF  Liao CH  Chen MC 《Chemosphere》2002,46(6):923-928
This paper evaluates the Fenton process, involving oxidation and coagulation, for the removal of color and chemical oxygen demand (COD) from synthetic textile wastewater containing polyvinyl alcohol and a reactive dyestuff, R94H. The experimental variables studied include dosages of iron salts and hydrogen peroxide, oxidation time, mixing speed and organic content. The results show that color was removed mainly by Fenton oxidation. The color removal reached a maximum of 90% at a reaction time of 5 min under low dosages of H2O2 and Fe2+. In contrast, the COD was removed primarily by Fenton coagulation, rather than by Fenton oxidation. The ratio of removal efficiency between Fenton process and ferric coagulation was 5.6 for color removal and 1.2 for COD removal. It is concluded that Fenton process for the treatment of textile wastewater favors the removal of color rather than COD.  相似文献   

19.
采用水热晶化法合成了不同含铜量的Cu—SBA-15介孔分子筛,并且用XRD、N2吸附、TEM以及uV—vis对所合成的样品进行表征。以Cu—SBA-15为催化剂,H2O2为氧化剂,催化湿式过氧化水溶液中的罗丹明B,主要考察H2O2浓度、催化剂用量、处理温度、初始pH等因素对罗丹明B氧化效果的影响。结果表明,在同样的处理条件下罗丹明的脱色率明显高于TOC去除率,处理温度、初始pH对罗丹明B的脱色与氧化有重要影响。在罗丹明B初始浓度100mg/L,H2O2初始浓度1.8g/L,催化剂量0.3g/L,温度60℃,pH为7.0,处理时间100min时,罗丹明B的脱色率为98.6%,TOC去除率为62.8%。  相似文献   

20.
VFAs、TOC及COD作为生物除磷能力指标的探讨   总被引:3,自引:0,他引:3  
在实际生活污水的处理中,研究了通过A/O运行模式对生物除磷过程中磷的变化情况及在厌氧释磷过程中COD、TOC与VFAs变化之间的关系。结果表明,在厌氧释磷过程中VFAs的变化更能准确地反映系统内释磷进程,实际生活污水中能直接用于磷释放的有机物含量占COD的13.33%,并且释放1 mg P所需VFAs为1.401 mg,此值明显低于前期研究结果。通过对COD、TOC和VFAs 3种组分的分析,可将实际生活污水中的有机底物分为3类:易生物降解含碳有机物、难降解的含碳有机物和水中存在的无机性还原物质,含量分别占COD的13.33%、31.7%和54.97%,其中只有13.33%的含量对生物释磷有直接作用,并可对实际生活污水除磷有指导意义。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号