首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Particulate matter (PM) emitted from cattle feedlots are thought to affect air quality in rural communities, yet little is known about factors controlling their emissions. The concentrations of PM (i.e., PM2.5, PM10, and total suspended particulates or TSP) upwind and downwind at two large cattle feedlots (KS1, KS2) in Kansas were measured with gravimetric samplers from May 2006 to October 2009 (at KS1) and from September 2007 to April 2008 (at KS2). The mean downwind and net (i.e., downwind - upwind) mass concentrations of PM2.5, PM10, and TSP varied seasonally, indicating the need for multiple-day, seasonal sampling. The downwind and net concentrations were closely related to the moisture content of the pen surface. The PM2.5/PM10 and PM2.5/TSP ratios at the downwind sampling location were also related to the moisture content of the pen surface, humidity, and temperature. Measurement of the particle size distribution downwind of the feedlot with a cascade impactor showed geometric mean diameter ranging from 7 to 18 microm, indicating that particles that were emitted from the feedlots were generally large in size.  相似文献   

2.
Although the fugitive dust associated with construction mud/dirt carryout can represent a substantial portion of the particulate matter (PM) emissions inventory in nonattainment areas, it has not been well characterized by direct sampling methods. In this paper, a research program is described that directly determined both PM10 and PM2.5 (particles < or =10 and 2.5 microm in classical aerodynamic diameter, respectively) emission factors for mud/dirt carryout from a major construction project located in metropolitan Kansas City, MO. The program also assessed the contribution of automotive emissions to the total PM2.5 burden and determined the baseline emissions from the test road. As part of the study, both time-integrated and continuous exposure-profiling methods were used to assess the PM emissions, including particle size and elemental composition. This research resulted in overall PM10 and PM2.5 emission factors of 6 and 0.2 g/vehicle, respectively. Although PM10 is within the range of prior U.S. Environmental Protection Agency (EPA) guidance, the PM2.5 emission factor is far lower than previous estimates published by EPA. In addition, based on both the particle size and chemical data obtained in the study, a major portion of the PM2.5 emissions appears to be attributable to automotive exhaust from light-duty, gasoline-powered vehicles and not to the fugitive dust associated with reentrained mud/dirt carryout.  相似文献   

3.
Now that the U.S. Environmental Protection Agency has promulgated new National Ambient Air Quality Standards for PM2.5, work will begin on generating the data required to determine the sources of ambient PM2.5 and the magnitude of their contributions to air pollution. This paper summarizes the results of an Environmental Research Consortium program, carried out under the auspices of the U.S. Council for Automotive Research. The program focused on particulate matter (PM) emissions from representative, current-technology, light-duty gasoline vehicles produced by DaimlerChrysler Corp., Ford Motor Co., and General Motors Corp. The vehicles, for the most part taken from the manufacturer's certification and durability fleets, were dynamometer-tested using the three-phase Federal Test Procedure in the companies' laboratories. The test fleet was made up of a mixture of both low-mileage (2K-35K miles) and high-mileage (60K-150K miles) cars, vans, sport utility vehicles, and light trucks. For each vehicle tested, PM emissions were accumulated over 4 cold-start tests, which were run on successive days. PM emission rates from the entire fleet (22 vehicles total) averaged less than 2 mg/mile. All 18 vehicles tested using California Phase 2 reformulated gasoline had PM emission rates less than 2 mg/mile at both low and high mileages.  相似文献   

4.
ABSTRACT

Now that the U.S. Environmental Protection Agency has promulgated new National Ambient Air Quality Standards for PM2.5, work will begin on generating the data required to determine the sources of ambient PM2.5 and the magnitude of their contributions to air pollution. This paper summarizes the results of an Environmental Research Consortium program, carried out under the auspices of the U.S. Council for Automotive Research. The program focused on particulate matter (PM) emissions from representative, current-technology, light-duty gasoline vehicles produced by DaimlerChrysler Corp., Ford Motor Co., and General Motors Corp. The vehicles, for the most part taken from the manufacturer's certification and durability fleets, were dynamometer-tested using the three-phase Federal Test Procedure in the companies' laboratories. The test fleet was made up of a mixture of both low-mileage (2K-35K miles) and high-mileage (60K-150K miles) cars, vans, sport utility vehicles, and light trucks. For each vehicle tested, PM emissions were accumulated over 4 cold-start tests, which were run on successive days. PM emission rates from the entire fleet (22 vehicles total) averaged less than 2 mg/mile. All 18 vehicles tested using California Phase 2 reformulated gasoline had PM emission rates less than 2 mg/ mile at both low and high mileages.  相似文献   

5.
Abstract

Although the fugitive dust associated with construction mud/dirt carryout can represent a substantial portion of the particulate matter (PM) emissions inventory in non-attainment areas, it has not been well characterized by direct sampling methods. In this paper, a research program is described that directly determined both PM10 and PM2.5 (particles ≤10 and 2.5 μm in classical aerodynamic diameter, respectively) emission factors for mud/dirt carryout from a major construction project located in metropolitan Kansas City, MO. The program also assessed the contribution of automotive emissions to the total PM2.5 burden and determined the baseline emissions from the test road. As part of the study, both time-integrated and continuous exposure-profiling methods were used to assess the PM emissions, including particle size and elemental composition. This research resulted in overall PM10 and PM2.5 emission factors of 6 and 0.2 g/vehicle, respectively. Although PM10 is within the range of prior U.S. Environmental Protection Agency (EPA) guidance, the PM2.5 emission factor is far lower than previous estimates published by EPA. In addition, based on both the particle size and chemical data obtained in the study, a major portion of the PM2.5 emissions appears to be attributable to automotive exhaust from light-duty, gasoline-powered vehicles and not to the fugitive dust associated with re-entrained mud/dirt carryout.  相似文献   

6.
Particulate matter < or =10 microm (PM10) emissions due to wind erosion can vary dramatically with changing surface conditions. Crust formation, mechanical disturbance, soil texture, moisture, and chemical content of the soil can affect the amount of dust emitted during a wind event. A refined method of quantifying windblown dust emissions was applied at Mono Lake, CA, to account for changing surface conditions. This method used a combination of real-time sand flux monitoring, ambient PM10 monitoring, and dispersion modeling to estimate dust emissions and their downwind impact. The method identified periods with high emissions and periods when the surface was stable (no sand flux), even though winds may have been high. A network of 25 Cox sand catchers (CSCs) was used to measure the mass of saltating particles to estimate sand flux rates across a 2-km2 area. Two electronic sensors (Sensits) were used to time-resolve the CSC sand mass to estimate hourly sand flux rates, and a perimeter tapered element oscillating microbalance (TEOM) monitor measured hourly PM10 concentrations. Hourly sand flux rates were related by dispersion modeling to hourly PM10 concentrations to back-calculate the ratio of vertical PM10 flux to horizontal sand flux (K-factors). Geometric mean K-factor values (K(f)) were found to change seasonally, ranging from 1.3 x 10(-5) to 5.1 x 10(-5) for sand flux measured at 15 cm above the surface (q15). Hourly PM10 emissions, F, were calculated by applying seasonal K-factors to sand flux measurements (F = K(f) x q15). The maximum hourly PM10 emission rate from the study area was 76 g/m2 x hr (10-m wind speed = 23.5 m/sec). Maximum daily PM10 emissions were estimated at 450 g/m2 x day, and annual emissions at 1095 g/m2 x yr. Hourly PM10 emissions were used by the U.S. Environmental Protection Agency (EPA) guideline AERMOD dispersion model to estimate downwind ambient impacts. Model predictions compared well with monitor concentrations, with hourly PM10 ranging from 16 to over 60,000 microg/m3 (slope = 0.89, R2 = 0.77).  相似文献   

7.
The U.S. Environmental Protection Agency (EPA) currently classifies Imperial County, CA, as a nonattainment area for PM10 (particulate matter [PM] < or = 10 microm in diameter), and this region suffers from high rates of chronic bronchitis and childhood asthma. Although high annual and daily average PM levels can have negative health and economic effects, recent studies have identified an association between adverse health effects and short-term PM spikes of tens of micrograms per cubic meter. This study identified PM episodes in Calexico/Mexicali that involve PM concentration spikes with concentrations up to 10 times greater than those reported to cause adverse health effects. These episodes appear to be relatively common during the winter months, are associated with wind speeds below 2 m/sec and stable boundary level heights below 500 m, and can comprise a large portion of the 24-hr PM levels. The organic composition of the PM10 samples collected during the low-wind/ high-PM episodes differed from that collected at other times. However, a preliminary source attribution identified only one significant difference between the source classes: agricultural burning accounted for 6.7% of organic-fraction PM10 for low-wind/high-PM episodes versus 0.25% at other times. This preliminary source attribution also revealed that motor vehicles were the most important relative contributor to organic PM10.  相似文献   

8.
There is a dearth of information on dust emissions from sources that are unique to the U.S. Department of Defense testing and training activities. However, accurate emissions factors are needed for these sources so that military installations can prepare accurate particulate matter (PM) emission inventories. One such source, coarse and fine PM (PM10 and PM2.5) emissions from artillery backblast testing on improved gun positions, was characterized at the Yuma Proving Ground near Yuma, AZ, in October 2005. Fugitive emissions are created by the shockwave from artillery pieces, which ejects dust from the surface on which the artillery is resting. Other contributions of PM can be attributed to the combustion of the propellants. For a 155-mm howitzer firing a range of propellant charges or zones, amounts of emitted PM10 ranged from -19 g of PM10 per firing event for a zone 1 charge to 92 g of PM10 per firing event for a zone 5. The corresponding rates for PM2.5 were approximately 9 g of PM2.5 and 49 g of PM2.5 per firing. The average measured emission rates for PM1o and PM2.5 appear to scale with the zone charge value. The measurements show that the estimated annual contributions of PM10 (52.2 t) and PM2.5 (28.5 t) from artillery backblast are insignificant in the context of the 2002 U.S. Environment Protection Agency (EPA) PM emission inventory. Using national-level activity data for artillery fire, the most conservative estimate is that backblast would contribute the equivalent of 5 x 10(-4) % and 1.6 x 10(-3)% of the annual total PM10 and PM2.5 fugitive dust contributions, respectively, based on 2002 EPA inventory data.  相似文献   

9.
Abstract

The U.S. Environmental Protection Agency (EPA) currently classifies Imperial County, CA, as a nonattainment area for PM10 (particulate matter [PM] ≤ 10 μm in diameter), and this region suffers from high rates of chronic bronchitis and childhood asthma. Although high annual and daily average PM levels can have negative health and economic effects, recent studies have identified an association between adverse health effects and short-term PM spikes of tens of micrograms per cubic meter. This study identified PM episodes in Calexico/Mexicali that involve PM concentration spikes with concentrations up to 10 times greater than those reported to cause adverse health effects. These episodes appear to be relatively common during the winter months, are associated with wind speeds below 2 m/sec and stable boundary level heights below 500 m, and can comprise a large portion of the 24-hr PM levels. The organic composition of the PM10 samples collected during the low-wind/high-PM episodes differed from that collected at other times. However, a preliminary source attribution identified only one significant difference between the source classes: agricultural burning accounted for 6.7% of organic-fraction PM10 for low-wind/high-PM episodes versus 0.25% at other times. This preliminary source attribution also revealed that motor vehicles were the most important relative contributor to organic PM10.  相似文献   

10.
The particle size distributions (PSDs) of particulate matter (PM) in the downwind plume from simulated sources of a cotton gin were analyzed to determine the impact of PM settling on PM monitoring. The PSD of PM in a plume varies as a function of gravitational settling. Gravitational settling has a greater impact on the downwind PSD from sources with PSDs having larger mass median diameters (MMDs). The change in PSD is a function of the source PSD of emitted PM, wind speed, and downwind distance. Both MMD and geometric standard deviation (GSD) in the downwind plume decrease with an increase in downwind distance and source MMD. The larger the source MMD, the greater the change in the downwind MMD and GSD. Also, the greater the distance from the source to the sampler, the greater the change in the downwind MMD and GSD. Variations of the PSD in the downwind plume significantly impact PM10 sampling errors associated with the U.S. Environmental Protection Agency (EPA) PM10 samplers. For the emission sources with MMD > 10 microm, the PM10 oversampling rate increases with an increase in downwind distance caused by the decrease of GSD of the PSD in the downwind plume. Gravitational settling of particles does not help reduce the oversampling problems associated with the EPA PM10 sampler. Furthermore, oversampling rates decrease with an increase of the wind speed.  相似文献   

11.
Two collaborative studies have been conducted by the U.S. Environmental Protection Agency (EPA) National Exposure Research Laboratory (NERL) and National Health and Environmental Effects Research Laboratory to determine personal exposures and physiological responses to particulate matter (PM) of elderly persons living in a retirement facility in Fresno, CA. Measurements of PM and other criteria air pollutants were made inside selected individual residences within the retirement facility and at a central outdoor site on the premises. In addition, personal PM exposure monitoring was conducted for a subset of the participants, and ambient PM monitoring data were available for comparison from the NERL PM research monitoring platform in central Fresno. Both a winter (February 1-28, 1999) and a spring (April 19-May 16, 1999) study were completed so that seasonal effects could be evaluated. During the spring study, a more robust personal exposure component was added, as well as a more detailed evaluation of physical factors, such as air-exchange rate, that are known to influence the penetration of particles into the indoor environment. In this paper, comparisons are made among measured personal PM exposures and PM mass concentrations measured at the NERL Fresno Platform site, outside on the premises of the retirement facility, and inside selected residential apartments at the facility during the two 28-day study periods. The arithmetic daily mean personal PM2.5 exposure during the winter study period was 13.3 micrograms/m3, compared with 9.7, 20.5, and 21.7 micrograms/m3 for daily mean overall apartment, outdoor, and ambient (i.e., platform) concentrations, respectively. The daily mean personal PM2.5 exposure during the spring study period was 11.1 micrograms/m3, compared with 8.0, 10.1, and 8.6 micrograms/m3 for the daily mean apartment, outdoor, and ambient concentrations, respectively.  相似文献   

12.
In response to community concerns, the air quality impact of imploding a 22-story building in east Baltimore, MD, was studied. Time- and space-resolved concentrations of indoor and outdoor particulate matter (PM) (nominally 0.5-10 microm) were measured using a portable nephelometer at seven and four locations, respectively. PM10 levels varied in time and space; there was no measurable effect observed upwind of the implosion. The downwind peak PM10 levels varied with distance (54,000-589 microg/m3) exceeding pre-implosion levels for sites 100 and 1130 m 3000- and 20-fold, respectively. Estimated outdoor 24-hr integrated mass concentrations varied from 15 to 72 microg/m3. The implosion did not result in the U.S. Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) for PM10 being exceeded. X-ray fluorescence analysis indicated that the elemental composition was dominated by crustal elements: calcium (57%), silicon (23%), aluminum (7.6%), and iron (6.1%). Lead was above background but at a low level (0.17 microg/m3). Peak PM10 concentrations were short-lived; most sites returned to background within 15 min. No increase in indoor PM10 was observed even at the most proximate 250 m location. These results demonstrate that a building implosion can have a severe but short-lived impact on community air quality. Effective protection is offered by being indoors or upwind.  相似文献   

13.
Chile is a fast-growing country with important industrial activities near urban areas. In this study, the mass and elemental concentrations of PM10 and PM2.5 were measured in five major Chilean urban areas. Samples of particles with diameter less than 10 microm (PM10) and 2.5 microm (PM2.5) were collected in 1998 in Iquique (northern Chile), Valparaiso, Vi?a del Mar, Rancagua (central Chile), and Temuco (southern Chile). Both PM10 and PM2.5 annual mean concentrations (PM10: 56.9-77.6 microg/m3; PM2.5: 22.4-42.6 microg/m3) were significantly higher than the corresponding European Union (EU) and U.S. Environmental Protection Agency (EPA) air quality standards. Moreover, the 24-hr PM10 and PM2.5 U.S. standards were exceeded infrequently for some of the cities (Rancagua and Valparaiso). Elements ranging from Mg to Pb were detected in the aerosol samples using X-ray fluorescence (XRF). For each of the five cities, factor analysis (FA) was applied to identify and quantify the sources of PM10 and PM2.5. The agreement between calculated and measured mass and elemental concentrations was excellent in most of the cities. Both natural and anthropogenic sources were resolved for all five cities. Soil and sea were the most important contributors to coarse particles (PM10-PM2.5), whereas their contributions to PM2.5 were negligible. Emissions from Cu smelters and oil refineries (and/or diesel combustion) were identified as important sources of PM2.5, particularly in the industrial cities of Rancagua, Valparaiso, and Vi?a del Mar. Finally, motor vehicles and wood burning were significant sources of both PM2.5 and PM10 in most of the cities (wood burning was not identified in Iquique).  相似文献   

14.
In this study, continuous data of PM10 (particles with aerodynamic diameter < 10 microns) concentration measurements for a 4-yr period were analyzed. These measurements have been carried out in the Eordea Basin, an industrial area in the northwestern mountainous region of Greece. The annual, monthly, and diurnal patterns are presented and investigated regarding the prevailing meteorological conditions and atmospheric processes that affect the ambient concentrations of PM10. The effect of wind on controlling PM10 concentration is also discussed. Based on the data analysis, an attempt is made to provide useful information about air quality levels, taking into account U.S. Environmental Protection Agency air quality standards.  相似文献   

15.
The role of emissions of volatile organic compounds and nitric oxide from biogenic sources is becoming increasingly important in regulatory air quality modeling as levels of anthropogenic emissions continue to decrease and stricter health-based air quality standards are being adopted. However, considerable uncertainties still exist in the current estimation methodologies for biogenic emissions. The impact of these uncertainties on ozone and fine particulate matter (PM2.5) levels for the eastern United States was studied, focusing on biogenic emissions estimates from two commonly used biogenic emission models, the Model of Emissions of Gases and Aerosols from Nature (MEGAN) and the Biogenic Emissions Inventory System (BEIS). Photochemical grid modeling simulations were performed for two scenarios: one reflecting present day conditions and the other reflecting a hypothetical future year with reductions in emissions of anthropogenic oxides of nitrogen (NOx). For ozone, the use of MEGAN emissions resulted in a higher ozone response to hypothetical anthropogenic NOx emission reductions compared with BEIS. Applying the current U.S. Environmental Protection Agency guidance on regulatory air quality modeling in conjunction with typical maximum ozone concentrations, the differences in estimated future year ozone design values (DVF) stemming from differences in biogenic emissions estimates were on the order of 4 parts per billion (ppb), corresponding to approximately 5% of the daily maximum 8-hr ozone National Ambient Air Quality Standard (NAAQS) of 75 ppb. For PM2.5, the differences were 0.1-0.25 microg/m3 in the summer total organic mass component of DVFs, corresponding to approximately 1-2% of the value of the annual PM2.5 NAAQS of 15 microg/m3. Spatial variations in the ozone and PM2.5 differences also reveal that the impacts of different biogenic emission estimates on ozone and PM2.5 levels are dependent on ambient levels of anthropogenic emissions.  相似文献   

16.
This work was motivated by the need to better reconcile emission factors for fugitive dust with the amount of geologic material found on ambient filter samples. The deposition of particulate matter with aerodynamic diameter less than or equal to 10 microm (PM10), generated by travel over an unpaved road, over the first 100 m of transport downwind of the road was examined at Ft. Bliss, near El Paso, TX. The field conditions, typical for warm days in the arid southwestern United States, represented sparsely vegetated terrain under neutral to unstable atmospheric conditions. Emission fluxes of PM10 dust were obtained from towers downwind of the unpaved road at 7, 50, and 100 m. The horizontal flux measurements at the 7 m and 100 m towers indicated that PM10 deposition to the vegetation and ground was too small to measure. The data indicated, with 95% confidence, that the loss of PM10 between the source of emission at the unpaved road, represented by the 7 m tower, and a point 100 m downwind was less than 9.5%. A Gaussian model was used to simulate the plume. Values of the vertical standard deviation sigma(z) and the deposition velocity Vd were similar to the U.S. Environmental Protection Agency (EPA) ISC3 model. For the field conditions, the model predicted that removal of PM10 unpaved road dust by deposition over the distance between the point of emission and 100 m downwind would be less than 5%. However, the model results also indicated that particles larger than 10 microm (aerodynamic diameter) would deposit more appreciably. The model was consistent with changes observed in size distributions between 7 m and 100 m downwind, which were measured with optical particle counters. The Gaussian model predictions were also compared with another study conducted over rough terrain and stable atmospheric conditions. Under such conditions, measured PM10 removal rates over 95 m of downwind transport were reported to be between 86% and 89%, whereas the Gaussian model predicted only a 30% removal. One explanation for the large discrepancy between measurements and model results was the possibility that under the conditions of the study, the dust plume was comparable in vertical extent to the roughness elements, thereby violating one of the model assumptions. Results of the field study reported here and the previous work over rough terrain bound the extent of particle deposition expected to occur under most unpaved road emission scenarios.  相似文献   

17.
ABSTRACT

Two collaborative studies have been conducted by the U.S. Environmental Protection Agency (EPA) National Exposure Research Laboratory (NERL) and National Health and Environmental Effects Research Laboratory to determine personal exposures and physiological responses to par-ticulate matter (PM) of elderly persons living in a retirement facility in Fresno, CA. Measurements of PM and other criteria air pollutants were made inside selected individual residences within the retirement facility and at a central outdoor site on the premises. In addition, personal PM exposure monitoring was conducted for a subset of the participants, and ambient PM monitoring data were available for comparison from the NERL PM research monitoring platform in central Fresno. Both a winter (February 1-28, 1999) and a spring (April 19-May 16, 1999) study were completed so that seasonal effects could be  相似文献   

18.
From 2004 to 2009, aiming to better understand implications for its smelters, Rio Tinto Alcan conducted a detailed study of PM2.5 and PM10 (particulate matter [PM] < or = 2.5 and 10 microm in aerodynamic diameter, respectively) in its facilities. This involved a two-level study: part 1, emission quantification; and part 2, assessment of aluminum smelter contribution to the surrounding environment. In the first part, U.S. Environmental Protection Agency Other Test Method (OTM) OTM27 and OTM28 are assessed as relevant and efficient methods for measuring fine particle emissions from aluminum smelter stacks. Rio Tinto Alcan has also developed a safe and robust method called CYCLEX to measure PM2.5 and condensable particulate matter (CPM) at the roof vents of potrooms. This work aims to determine the PM2.5 emission coefficients of 17, 55, and 417 g x t(-1) of aluminum produced (including CPM) in anode baking furnace exhaust (fume treatment center), at potroom scrubber stacks (gas treatment centers), and at potroom roof vents, respectively. Results indicate that roof vents are the primary PM2.5 emitters (85% of all smelter emissions) and that 71% of all smelter PM2.5 comes from CPM. In the second part, preliminary inorganic speciation studies are conducted by scanning electron microscopy-energy-dispersive X-ray analysis and by isotopic ratios to track smelter emissions to their surrounding environment. This paper releases the first speciation results for an aluminum smelter, and the preliminary isotopic ratio study indicates a 3% impact in terms of PM2.5 emissions for a representative smelter in an urban area.  相似文献   

19.
The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions.

Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.  相似文献   


20.
ABSTRACT

With the promulgation of a national PM2.5 ambient air quality standard, it is important that PM2.5 emissions inventories be developed as a tool for understanding the magnitude of potential PM2.5 violations. Current PM10 inventories include only emissions of primary particulate matter (1 ï PM), whereas, based on ambient measurements, both PM10 and PM2.5 emissions inventories will need to include sources of both 1ï PM and secondary particulate matter (2ï PM). Furthermore, the U. S. Environmental Protection Agency’s (EPA) current edition of AP-42 includes size distribution data for 1o PM that overestimate the PM2.5 fraction of fugitive dust sources by at least a factor of 2 based on recent studies.

This paper presents a PM2.5 emissions inventory developed for the South Coast Air Basin (SCAB) that for the first time includes both 1ï PM and 2ï PM. The former is calculated by multiplying PM10 emissions estimates by the PM2.5/PM10 ratios for different sources. The latter is calculated from estimated emission rates of gas-phase aerosol precursor and gas to aerosol conversion rates consistent with the measured chemical composition of ambient PM2.5 concentrations observed in the SCAB. The major finding of this PM2.5 emissions inventory is that the aerosol component is more than twice the aerosol component, which may result in widely different control strategies being required for fine PM and coarse PM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏