1.
ABSTRACT

The size range of airborne particles that is closely related to specific deposition regions in the human respiratory tract and excess lung burden of these deposited particles is associated with disease. Size-selective sampling, therefore, needs to be performed to assess the related health risks. Performance criteria applied to these samplers must be well characterized in order to provide accurate and reliable results. The PM10 samplers that have been used in place of the total suspended particulate samplers for the collection of ambient air particles are more relevant to potential inhalation hazards. In order to be certified, a PM10 sampler must meet reliable performance specifications, primarily the aerosol penetration test with liquid and solid particles in a wind tunnel (wind speeds of 2, 8, and 24 km/hr). This testing is intended to assure reasonable accuracy in aerosol measurements. However, the sampler performance under calm air conditions has not been well studied.

In the present study, the sampling heads of three devices—the Harvard impactor, the Personal Environmental Monitor (PEM), and the Sierra Andersen model 241 dichotomous sampler PM10 inlet head—were tested for aerosol separation efficiency. With the consideration of bias and imprecision of the measurements, five specimens of each type of sampler were chosen for performance testing, repeating the tests 5 times for each specimen. An ultrasonic atomizing nozzle was used to nebulize potassium sodium tartrate tetrahydrate and dioctyl phthalate particles as the solid and liquid challenge aerosols, respectively. The aerosol number concentrations and size distributions upstream and downstream of the samplers were measured by using an aerosizer calibrated against a settling velocity chamber. The results showed that among the samplers tested, the dichotomous sampler PM10 inlet head had the best fit to the PM10 convention, while the other two samplers not only appeared to have a steeper separation-curve slope but also had significant particle bounce when challenged with solid particles. Analysis of variance also confirmed the superiority of the dichotomous samplers. Surface-coating with oil or grease greatly reduced the problem of particle bounce.  相似文献   

2.
The size range of airborne particles that is closely related to specific deposition regions in the human respiratory tract and excess lung burden of these deposited particles is associated with disease. Size-selective sampling, therefore, needs to be performed to assess the related health risks. Performance criteria applied to these samplers must be well characterized in order to provide accurate and reliable results. The PM10 samplers that have been used in place of the total suspended particulate samplers for the collection of ambient air particles are more relevant to potential inhalation hazards. In order to be certified, a PM10 sampler must meet reliable performance specifications, primarily the aerosol penetration test with liquid and solid particles in a wind tunnel (wind speeds of 2, 8, and 24 km/hr). This testing is intended to assure reasonable accuracy in aerosol measurements. However, the sampler performance under calm air conditions has not been well studied. In the present study, the sampling heads of three devices--the Harvard impactor, the Personal Environmental Monitor (PEM), and the Sierra Andersen model 241 dichotomous sampler PM10 inlet head--were tested for aerosol separation efficiency. With the consideration of bias and imprecision of the measurements, five specimens of each type of sampler were chosen for performance testing, repeating the tests 5 times for each specimen. An ultrasonic atomizing nozzle was used to nebulize potassium sodium tartrate tetrahydrate and dioctyl phthalate particles as the solid and liquid challenge aerosols, respectively. The aerosol number concentrations and size distributions upstream and downstream of the samplers were measured by using an aerosizer calibrated against a settling velocity chamber. The results showed that among the samplers tested, the dichotomous sampler PM10 inlet head had the best fit to the PM10 convention, while the other two samplers not only appeared to have a steeper separation-curve slope but also had significant particle bounce when challenged with solid particles. Analysis of variance also confirmed the superiority of the dichotomous samplers. Surface-coating with oil or grease greatly reduced the problem of particle bounce.  相似文献   

3.
Acidic aerosol concentrations measured by an annular denuder system (ADS) and a honeycomb denuder system (HDS) in Hsinchu, Taiwan, were compared. Aerosols were also sampled by a MOUDI (micro-orifice uniform deposit impactor) and analyzed by an ion chromatograph to determine the size distributions of different species. Using the measured aerosol size distribution, theoretical analysis showed that positive HNO3 artifact due to volatilization of NH4NO3 is generally negligible for both samplers. Comparing two different denuder samplers, the average concentration of HNO3 measured by the ADS was found to be lower than that measured by the HDS, while the difference between the two samplers for the average concentration of other species was found to be within +/- 15%. A possible cause of the difference in HNO3 concentrations is due to a greater loss of HNO3 in the cyclone used by the ADS than in the impactor used by the HDS. The study also showed incomplete absorption of the evaporated HCl and HNO3 from the particles on the Teflon filter by the first nylon filter in the filter pack of the ADS. Collection efficiency and capacity of HCl and HNO3 by the nylon filters need further investigation.  相似文献   

4.
The body of information presented in this paper is directed to investigators using inertial samplers for precise and accurate studies of respirable aerosols. The conventions commonly used for aerodynamic size for aerosol particles are discussed including the definition popularized by the "Task Group on Lung Dynamics" of the ICRP, and the "Lovelace" definition. To emphasize the distinction, the Task Group definition (unit density sphere equivalent) is called the aerodynamic equivalent diameter, Dae, and the Lovelace definition (characteristic expression based upon viscous resistance) is called the aerodynamic resistance diameter, Dar. The implications and efficacy of these conventions are related to procedures for calibration of cascade impactors, cyclones, and spiral centrifuges. The calibration of a spiral centrifuge at different altitudes is used as an example of the potential problems associated with the use of the different conventions for describing aerodynamic size. The aerodynamic resistance diameter is recommended for calibration of inertial samplers to be used to collect aerosols in the respirable size range.  相似文献   

5.
The design and function of a device that regulates the relative humidity of an ambient aerosol sample is described. We use this RH controller upstream of MOUDI impactors to permit sampling at relative humidities in the 70–80% range. Humidity control is achieved by allowing the aerosol to approach equilibrium with a saturated salt solution. Benefits to sampling with impactors in this relative humidity range include greatly reduced bounce of fine, hygroscopic particles, minimal flow-induced sizing errors, and minimization of uncertainties in measured size distributions due to diurnal variations in relative humidity during sampling. Data from field measurements in a humid environment (Look Rock, TN) and arid environments (Las Vegas, NV and Meadview, AZ) are discussed.  相似文献   

6.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22 degrees C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at -70 degrees C to -80 degrees C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
In the industrial city of Hamilton, Ontario, Canada, we recently carried out an epidemiological study of the effect of environmental factors on respiratory health in 3500 elementary, schoolchildren. The level and size distribution of suspended particles in ambient air was measured from 24-h samples taken at 6-day intervals from a network of 29 hivol TSP samplers, and nine Andersen 2000 4-stage cascade impactors. Exposure was computed by generating a 3-dimensional response surface (in TSP and in easting and northing geographical coordinates) using a linear regression model of the form: TSP = (1 + E + N)2, based on monthly geometrical mean data for all sites. From the response surface generated for a given month, TSP levels were predicted by the model for all schools by specifying their geographical coordinates. The yearly exposure for a given child was determined from the arithmetic mean of the predicted values for 12 monthly TSP levels. A similar procedure was employed for calculation of the exposure to the "fine" (≤3.3 μm) and "coarse" (>3.3 μm) size fraction, as well as the aerodynamic mass median diameter of particles from the network of cascade impactors. Results of the measurements showed that gradients for TSP up to approximately 10 μg/m3/km exist over the city covering distances from 5 to 10 km. The range of 1 yr mean exposure values calculated for each child was from 30.5 μg/m3 to 74.5 μg/m3. Comparable figures for particle size were up to 0.3 μm AMMD (aerodynamic mass median diameter)/km and annual mean particle size exposure from 2.69 to 3.53 μm AMMD.  相似文献   

8.
Two single round nozzle impactors have been developed for use in Harvard’s indoor air pollution health study. Both impactors operate at flow rates of 4 L/m and are nearly identical, differing only in their cut sizes of 2.5 μm and 10 μm aerodynamic diameters. Two identical cascaded stages of the same cut size are used to obtain sharp cut-off characteristics. The particles are deposited on impaction plates made of oil impregnated, porous material to reduce particle bounce and are discarded. Only the particles collected on the afterfilter are analyzed. Special care has been taken to collect the particles uniformly on the afterfilter to aid in particle analysis.

The jmpactors were calibrated with a vibrating orifice monodisperse aerosol generator. However, due to the sharp cut of the impactors, doublets and triplets in the calibration aerosols, even in small quantities, gave erroneous calibration curves. Therefore, the number of doublets and triplets in the challenging aerosols were measured and appropriate corrections made to the calibration curves.  相似文献   

9.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon® impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22°C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at ?70°C to ?80°C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set. Results indicate that the sample handling variations and collection period variables had no significant effect on recovery of organics or mutagens. However, a filter type difference was observed. The sonication extraction of organics and mutagens was significantly greater for TIGF filters than for glass fiber or quartz. Results from a second phase of study indicated differences in extracted organics and mutagens for these filter types.  相似文献   

10.
Hydrogen sulfide and other sulfides can be determined in the part per billion range in air if the air is bubbled through an absorption mixture of an alkaline suspension of cadmium hydroxide contained in a macro impinger. Rates as high as 1 cubic foot per minute can be used, or 0.1 cubic foot per minute with a midget impinger. The concentration of the trapped sulfides is then estimated by the methylene blue method. A colorimetric method and a spectrophotometric method are described.  相似文献   

11.
ABSTRACT

Acidic aerosol concentrations measured by an annular denuder system (ADS) and a honeycomb denuder system (HDS) in Hsinchu, Taiwan, were compared. Aerosols were also sampled by a MOUDI (micro-orifice uniform deposit impactor) and analyzed by an ion chromatograph to determine the size distributions of different species. Using the measured aerosol size distribution, theoretical analysis showed that positive HNO3 artifact due to volatiliza-tion of NH4NO3 is generally negligible for both samplers.4 3Comparing two different denuder samplers, the average concentration of HNO3 measured by the ADS was found3to be lower than that measured by the HDS, while the difference between the two samplers for the average concentration of other species was found to be within ±15%. A possible cause of the difference in HNO3 con-3centrations is due to a greater loss of HNO3 in the cyclone3 used by the ADS than in the impactor used by the HDS. The study also showed incomplete absorption of the evaporated HCl and HNO3 from the particles on the Teflon3filter by the first nylon filter in the filter pack of the ADS. Collection efficiency and capacity of HCl and HNO3 by3the nylon filters need further investigation.  相似文献   

12.
The present study attempts to investigate the emission characteristics of fine particles with special emphasis on nickel and vanadium metal elements emitted from the heavy oil combustion in industrial boilers and power plant, which are typical anthropogenic sources in Korea. A series of combustion experiments were performed to investigate the emission characteristics of particles in the size range of submicron by means of drop-tube furnace with three major domestic heavy oils. Cascade impactors were utilized to determine the size distribution of particulates as well as to analyze the partitioning enrichment of vanadium and nickel in various size ranges. Experimental results were compared with field data of particle size distribution and metal partitioning at commercial utility boilers with heavy oil combustion. Such data were interpreted by chemical equilibrium and particle growth mechanism by means of computational models. In general, fine particles were the major portion of PM10 emitted from the heavy oil combustion, with significant fraction of ultra-fine particles. The formation of ultra-fine particles through nucleation/condensation/coagulation from heavy oil combustion was confirmed by field and experimental data. Vanadium and nickel were more enriched in fine particles, particularly in ultra-fine particles. The conventional air pollution devices showed inefficient capability to remove ultra-fine particles enriched with hazardous transition metal elements such as vanadium and nickel.  相似文献   

13.
From 1993 through 1998, Wedding or Graseby high-volume PM10 samplers were collocated with tapered element oscillating microbalance (TEOM) samplers at three sites at Owens Lake, CA. The study area is heavily impacted by windblown dust from the dry Owens Lake bed, which was exposed as a result of water diversions to the city of Los Angeles. A dichotomous (dichot) sampler and three collocated Partisol samplers were added in 1995 and 1999, respectively. U.S. Environmental Protection Agency (EPA) operating procedures were followed for all samplers, except for a Wedding sampler that was not cleaned for the purpose of this study. On average, the TEOM and Partisol samplers agreed to within 6%, and the dichot, Graseby, and Wedding samplers measured lower PM10 concentrations by about 10, 25, and 35%, respectively. Surprisingly, the "clean" Wedding sampler consistently measured the same concentration as the "dirty" Wedding sampler through 85 runs without cleaning. The finding that the Graseby and Wedding high-volume PM10 samplers read consistently lower than the TEOM, Partisol, and dichot samplers at Owens Lake is consistent with PM10 sampler comparisons done in other fugitive dust areas, and with wind tunnel tests showing that sampler cut points can be significantly lower than 10 microns under certain conditions. However, these results are opposite of the bias found for TEOM samplers in areas that have significant amounts of volatile particles, where the TEOM reads low due to the vaporization of particles on the TEOM's heated filter. Coarse particles like fugitive dust are relatively unaffected by the filter temperature. This study shows that in the absence of volatile particles and in the presence of fugitive dust, a different systematic bias of up to 35% exists between samplers using dichot inlets and high-volume samplers, which may cause the Graseby and Wedding PM10 samplers to undermeasure PM10 by up to 35% when the PM10 is predominantly from coarse particulate sources.  相似文献   

14.
ABSTRACT

Ambient particles contain substantial quantities of material that can be lost from the particles during sample collection on a filter. These include ammonium nitrate and semi-volatile organic compounds. As a result, the concentrations of these species are often significantly in error for results obtained with a filter pack sampler. The accurate measurement of these semi-volatile fine particulate species is essential for a complete understanding of the possible causes of health effects associated with exposure to fine particles. Past organic compound diffusion denuder samplers developed by the authors (e.g., the Brigham Young University Organic Sampling System [BOSS]) are not amenable to routine field use because of the need to independently determine the gas-phase semi-volatile organic material efficiency of the denuder for each sample. This problem has been eliminated using a combined virtual impactor, particle-concentrator inlet to provide a concentrated stream of 0.1-2.5-μm particles. This is followed by a BOSS diffusion denuder and filter packs to collect particles, including any semi-volatile species lost from the particles during sampling. The samp ler (Particle Concentrator-Brigham Young University Organic Sampling System [PC-BOSS]) contains a post-denuder multifilter pack unit to allow for the routine collection of several sequential samples. The PC-BOSS can be used for the determination of both fine particulate nitrate and semi-volatile organic material without significant “positive” or “negative” sampling artifacts. Validation of the sampler for the determination of PM2.5 sulfate and nitrate based on comparison of results obtained at Riverside, CA with collocated PC-BOSS, annular denuder, and Chem Spec samplers indicates the PC-BOSS gives accurate results for these species with a precision of ±5-8%. An average of 33% of the PM2.5 nitrate was lost from the particles during sampling for both denuder and single filter samplers.  相似文献   

15.
Polyurethane foam was incorporated as a prefilter on standard hi-volume samplers of the National Air Sampling Network (NASN) in an exploratory study. The foam selectively filtered particles of various sizes. The characteristics of the particles passing through the foam approached the respirable size fraction as defined by reports of the Atomic Energy Commission. The respirable fraction was then collected on a glass-fiber filter. Parameters such as pore size and thickness of the foam, air flow rates, and loadings were studied to determine their effects on the filtration of “respirable” dust. Ambient air was the particulate source, and sizing was accomplished by an Andersen sampler coupled with nephelometric analyses. Some sizing was also done microscopically. The foam was evaluated at several locations to account for possible variations in ambient air over areas of different industrial complexity.  相似文献   

16.
ABSTRACT

From 1993 through 1998, Wedding or Graseby high-volume PM10 samplers were collocated with tapered element oscillating microbalance (TEOM) samplers at three sites at Owens Lake, CA. The study area is heavily impacted by windblown dust from the dry Owens Lake bed, which was exposed as a result of water diversions to the city of Los Angeles. A dichotomous (dichot) sampler and three collocated Partisol samplers were added in 1995 and 1999, respectively. U.S. Environmental Protection Agency (EPA) operating procedures were followed for all samplers, except for a Wedding sampler that was not cleaned for the purpose of this study. On average, the TEOM and Partisol samplers agreed to within 6%, and the dichot, Graseby, and Wedding samplers measured lower PM10 concentrations by about 10, 25, and 35%, respectively. Surprisingly, the “clean” Wedding sampler consistently measured the same concentration as the “dirty” Wedding sampler through 85 runs without cleaning. The finding that the Graseby and Wedding high-volume PM10 samplers read consistently lower than the TEOM, Partisol, and dichot samplers at Owens Lake is consistent with PM10 sampler comparisons done in other fugitive dust areas, and with wind tunnel tests showing that sampler cut points can be significantly lower than 10 um under certain conditions. However, these results are opposite of the bias found for TEOM samplers in areas that have significant amounts of volatile particles, where the TEOM reads low due to the vaporization of particles on the TEOM's heated filter. Coarse particles like fugitive dust are relatively unaffected by the filter temperature. This study shows that in the absence of volatile particles and in the presence of fugitive dust, a different systematic bias of up to 35% exists between samplers using dichot inlets and high-volume samplers, which may cause the Graseby and Wedding PM10 samplers to undermeasure PM10 by up to 35% when the PM10 is predominantly from coarse particulate sources.  相似文献   

17.
Aerosols present upwind and downwind of freeways in the Los Angeles Basin were collected in five particle size ranges by Lundgren impactors with after filters and analyzed for elemental content by ion-excited x-ray emission. The contribution of freeway traffic to total airborne particulate load was obtained by subtracting the local background, measured by an upwind sampler, from the values obtained by downwind samplers on a size by size, element by element basis. This contribution correlated reasonably well with estimates derived from automotive and roadbed expendable rates. Traffic-derived aerosols, normalized to vehicular flow, were considerably lower in mass downwind of depressed roadbed configurations than either at grade or raised configurations. A line source model, combined with literature values for emitted lead, produced good agreement with results obtained in the at grade configuration.  相似文献   

18.
Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.  相似文献   

19.
Correct assessment of fine particulate carbonaceous material as a function of particle size is, in part, dependent on the determination of semi-volatile compounds, which can be lost from particles during sampling. This study gives results obtained for the collection of fine particulate carbonaceous material at three eastern U.S. sampling sites [Philadelphia, PA; Shenandoah National Park, VA; and Research Triangle Park (RTP), NC] using diffusion denuder technology. The diffusion denuder samplers allow for the determination of fine particulate organic material with no artifacts, due to the loss of semi-volatile organic particulate compounds, or collection of gas-phase organic compounds by the quartz filter during sampling. The results show that an average of 41, 43, and 59% of fine particulate organic material was lost as volatilized semi-volatile organic material during collection of particles on a filter at Philadelphia, RTP, and Shenandoah, respectively. The particle size distribution of carbonaceous material retained by a filter and lost from a filter during sampling was obtained for the samples collected at Philadelphia and Shenandoah. The carbonaceous material retained by the particles during sampling was found predominantly in particles smaller than 0.4 microm in aerodynamic diameter. In contrast, the semi-volatile organic material lost from the particles during sampling had a mass median diameter of approximately 0.5 microm.  相似文献   

20.
The sensory pollutants emitted by loaded ventilation filters are assumed to include products formed via oxidation of organics associated with captured particles. In this study, experiments were performed that used either particle production or ozone removal as probes to further improve our understanding of such processes. The measured ratio of downstream to upstream submicron particle concentrations increased when ozone was added to air passing through samples from loaded particle filters. Such an observation is consistent with low volatility oxidation products desorbing from the filter and subsequently partitioning between the gas phase and the surface of particles that have passed through the filter, including particles that were previously too small (<20 nm) to be detected by the instrument used in these studies. A related set of experiments conducted with unused filters and filters that had been in service from 2 to 16 weeks found that ozone removal efficiencies changed in a manner that indicated at least two different removal mechanisms—reactions with compounds present on the filter media following manufacturing and reactions with compounds associated with captured particles. The contribution from the former varies with the type and manufacturer of the filter, while that of the latter varies with the duration of service and nature of the captured particles. In complimentary experiments, a filter sample protected from ozone during its 9 weeks of service had higher ozone removal efficiencies than an identical filter not protected from ozone during the same 9 weeks of service filtering the same air. This result indicates that a filter's exposure history subsequently influences the quantity of oxidation products generated when ozone-containing air flows through it.  相似文献   