首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
An aerobic sequencing batch biofilm reactor (SBBR) packed with Bauer rings was used to treat real domestic wastewater for simultaneous nitrification and denitrification. The SBBR is advantageous for creating an anoxic condition, and the biofilm can absorb and store carbon for good nitrification and denitrification. An average concentration of oxygen ranging from 0.8 to 4.0 mg/L was proved very efficient for nitrification and denitrification. Volumetric loads of TN dropped dramatically and effluent TN concentration increased quickly when the concentration of average dissolved oxygen was more than 4.0 mg/L. The efficiency of simultaneous nitrification and denitrification (SND) increased with increasing thickness of the biofilm. The influent concentration hardly affected the TN removal efficiency, but the effluent TN increased with increasing influent concentration. It is suggested that a subsequence for denitrification be added or influent amount be decreased to meet effluent quality requirements. At optimum operating parameters, the TN removal efficiency of 74%–82% could be achieved.  相似文献   

2.
A new biological nitrogen removal process, which is named herein “The circulating fluidized bed bioreactor (CFBBR)”, was developed for simultaneous removal of nitrogen and organic matter. This process was composed of an anaerobic bed (Riser), aerobic bed (Downer) and connecting device. Influent and nitrified liquid from the aerobic bed enters the anaerobic bed from the bottom of the anaerobic bed, completing the removal of nitrogen and organic matter. The system performance under the conditions of different inflow loadings and nitrified liquid recirculation rates ranging from 200% to 600% was examined. From a technical and economic point of view, the optimum nitrified liquid recirculation ratewas 400%. With a shortest total retention time of 2.5 h (0.8 h in the anaerobic bed and 1.5 h in the aerobic bed) and a nitrified liquid recirculation rate of 400% based on the influent flow rate, the average removal efficiencies of total nitrogen (TN) and soluble chemical oxygen demand (SCOD) were found to be 88% and 95%, respectively. The average effluent concentrations of TN and SCOD were 3.5 mg/L and 16 mg/L, respectively. The volatile suspended solid (VSS) concentration, nitrification rate and denitrification rate in the system were less than 1.0 g/L, 0.026-0.1 g NH4 +-N/g VSS·d, and 0.016–0.074 g NOx ?-N/g VSS·d, respectively.  相似文献   

3.
新型废水生物脱氮的微生物学研究进展   总被引:18,自引:0,他引:18  
生物脱氮是含氮废水处理公认的最佳处理方式,随着对生物脱氮微生物学原理研究的不断深入,许多新的生物脱氮特殊菌株或菌群及微生物转化机制不断被发现.本文在传统生物脱氮过程机理上,结合最近国内外生物脱氮的新发现,就短程硝化反硝化、同时硝化反硝化、厌氧氨氧化的微生物学原理进行了阐述.图1表2参23  相似文献   

4.
考察了不同进水有机物浓度下厌氧/好氧序批式移动床生物膜反应器(SBMBBR)污染物去除特性,实验结果表明,SBMBBR能够实现低碳源污水中氮和磷的同步去除,在进水TN和TP浓度分别为116.7 mg.L-1和11.5 mg.L-1、COD浓度为456 mg.L-1的条件下,TN和TP去除率分别达到94.3%和92.2%以上.反应器除磷是基于常规生物除磷和反硝化除磷过程实现的,脱氮主要是基于好氧段发生的同时硝化反硝化(SND)作用而完成.由于生物膜内部存在的DO扩散梯度,在好氧阶段混合液DO浓度不断提高的条件下反应器内具有良好SND反应的发生.进水COD浓度由149 mg.L-1提高至456 mg.L-1的过程中,反应器硝化效果不变,反硝化和除磷效果改善.反应器在好氧阶段pH值基本维持在7.0—7.1之间,为各类菌群的生长创造了条件.碱度变化较pH值更能反映硝化和反硝化反应发生的程度.反应器中微生物相丰富,生物膜以丝状菌为骨架,其上附着大量的球状菌和杆状菌,而悬浮活性污泥中丝状菌较少,形成了由细菌、真菌到原生动物和后生动物的复杂的生态体系,为系统取得稳定的污水处理效果提供了有效的保证.  相似文献   

5.
• Simultaneous C & N removal in Methammox occurs at wide C:N ratio. • Biological Nitrogen Removal at wide C:N ratio of 1.5:1 to 14:1 is not reported. • Ammonia removal shifted from mixotrophy to heterotrophy at high C:N ratio. • Acetogenic population compensated for ammonia oxidizers at high C:N ratio. • Methanogens increase the plasticity of nitrogen removers at high C:N ratio. High C:N ratio in the wastewater limits biological nitrogen removal (BNR), especially in anammox based technologies. The present study attempts to improve the COD tolerance of the BNR process by associating methanogens with nitrogen removing bacterial (NRB) populations. The new microbial system coined as ‘Methammox’, was investigated for simultaneous removal of COD (C) and ammonia (N) at C:N ratio 1.5:1 to 14:1. The ammonia removal rate (11.5 mg N/g VSS/d) and the COD removal rates (70.6 mg O/g VSS/d) of Methammox was close to that of the NRB (11.1 mg N/g VSS/d) and the methanogenic populations (77.9 mg O/g VSS/d), respectively. The activities established that these two populations existed simultaneously and independently in ‘Methammox’. Further studies in biofilm reactor fetched a balanced COD and ammonia removal (55%–60%) at a low C:N ratio (≤2:1) and high C:N ratio (≥9:1). The population abundance of methanogens was reasonably constant, but the nitrogen removal shifted from mixotrophy to heterotrophy as the C:N ratio shifted from low (C:N≤2:1) to high (C:N≥9:1). The reduced autotrophic NRB (ammonia- and nitrite-oxidizing bacteria and Anammox) population at a high C:N ratio was compensated by the fermentative group that could carry out denitrification heterotrophically. The functional plasticity of the Methammox system to adjust to a broad C:N ratio opens new frontiers in biological nitrogen removal of high COD containing wastewaters.  相似文献   

6.
● Dolomite-doped biochar/bentonite was synthesized for phosphate removal. ● DO/BB exhibited a high phosphate adsorption capacity in complex water environments. ● PVC membrane incorporated with DO/BB can capture low concentration phosphate. ● Electrostatic interaction, complexation and precipitation are main mechanisms. The removal of phosphate from wastewater using traditional biological or precipitation methods is a huge challenge. The use of high-performance adsorbents has been shown to address this problem. In this study, a novel composite adsorbent, composed of dolomite-doped biochar and bentonite (DO/BB), was first synthesized via co-pyrolysis. The combination of initial phosphate concentration of 100 mg/L and 1.6 g/L of DO/BB exhibited a high phosphate-adsorption capacity of 62 mg/g with a removal efficiency of 99.8%. It was also stable in complex water environments with various levels of solution pH, coexisting anions, high salinity, and humic acid. With this new composite, the phosphate concentration of the actual domestic sewage decreased from 9 mg/L to less than 1 mg/L, and the total nitrogen and chemical oxygen demand also decreased effectively. Further, the cross-flow treatment using a PVC membrane loaded with DO/BB (PVC-DO/BB), decreased the phosphate concentration from 1 to 0.08 mg/L, suggesting outstanding separation of phosphate pollutants via a combination of adsorption and separation. In addition, the removal of phosphate by the PVC-DO/BB membrane using NaOH solution as an eluent was almost 90% after 5 cycles. The kinetic, isotherm and XPS analysis before and after adsorption suggested that adsorption via a combination of electrostatic interaction, complexation and precipitation contributed to the excellent separation by the as-obtained membranes.  相似文献   

7.
序批式膜反应器处理高氨氮渗滤液同步硝化反硝化特性   总被引:1,自引:1,他引:0  
应用序批式生物膜反应器(SBBR)处理实际垃圾渗滤液,在DO浓度分别为0.45mg.l-1和1.19mg.l-1条件下,研究了系统的有机物,氨氮和总氮去除特性以及游离氨(FA),DO对系统同步硝化反硝化(SND)类型的影响.250d试验研究表明:SBRR系统能够稳定高效地同步去除渗滤液内高浓度有机物和高浓度氨氮.在初始COD浓度为122—2385 mg.l-1的情况下,出水COD浓度为23—929 mg.l-1,有机物最大去除速率25.6 kgCOD.m-2载体.d-1.在初始NH4+-N浓度为40—396.5 mg.l-1的情况下,出水NH4+-N浓度为0—41.2 mg.l-1,最大硝化速率2.87 kgN.m-2载体.d-1.SBBR系统内发生了明显的同步硝化反硝化(SND)现象,TN平均去除率分别为73.8%(DO=0.45 mg.l-1)和30%(DO=1.19 mg.l-1)左右.当FA浓度在1.5—11.6 mg.l-1范围内时,系统中共存硝酸型SND和亚硝酸性SND.当FA从18.6 mg.l-1增加到56 mg.l-1,系统中形成稳定的亚硝酸SND.因此,FA是影响系统SND类型的主要因素,DO可促进亚硝酸性SND向硝酸型SND转化.  相似文献   

8.
Since eutrophication has become increasingly severe in China, nitrogen and phosphorous have been the concern of wastewater treatment, especially nitrogen removal. The stabilization of the intelligent control system and nitrogen removal efficiency were investigated in a pilot-scale aerobic-anoxic sequencing batch reactor (SBR) with a treatment capacity of 60 m3/d. Characteristic points on the profiles of dissolved oxygen (DO), pH, and oxidation reduction potential (ORP) could exactly reflect the process of nitrification and denitrification. Using the intelligent control system not only could save energy, but also could achieve advanced nitrogen removal. Applying the control strategy water quality of the effluent could stably meet the national first discharge standard during experiment of 10 months. Even at low temperature (t = 13°C), chemical oxygen demand (COD) and total nitrogen (TN) in the effluent were under 50 and 5 mg/L, respectively.  相似文献   

9.
• MES was constructed for simultaneous ammonia removal and acetate production. • Energy consumption was different for total nitrogen and ammonia nitrogen removal. • Energy consumption for acetate production was about 0.04 kWh/g. • Nitrate accumulation explained the difference of energy consumption. • Transport of ammonia and acetate across the membrane deteriorated the performance. Microbial electrosynthesis (MES) is an emerging technology for producing chemicals, and coupling MES to anodic waste oxidation can simultaneously increase the competitiveness and allow additional functions to be explored. In this study, MES was used for the simultaneous removal of ammonia from synthetic urine and production of acetate from CO2. Using graphite anode, 83.2%±5.3% ammonia removal and 28.4%±9.9% total nitrogen removal was achieved, with an energy consumption of 1.32 kWh/g N for total nitrogen removal, 0.45 kWh/g N for ammonia nitrogen removal, and 0.044 kWh/g for acetate production. Using boron-doped diamond (BDD) anode, 70.9%±12.1% ammonia removal and 51.5%±11.8% total nitrogen removal was obtained, with an energy consumption of 0.84 kWh/g N for total nitrogen removal, 0.61 kWh/g N for ammonia nitrogen removal, and 0.043 kWh/g for acetate production. A difference in nitrate accumulation explained the difference of total nitrogen removal efficiencies. Transport of ammonia and acetate across the membrane deteriorated the performance of MES. These results are important for the development of novel electricity-driven technologies for chemical production and pollution removal.  相似文献   

10.
低温下曝气生物滤池预处理污染河水的试验研究   总被引:1,自引:0,他引:1  
采用两段曝气生物滤床串联工艺预处理入滇新运粮河河水,研究了其在冬天低温条件下对有机物和氨氮的去除效果,并考察了pH值的变化。结果表明,在进水流量为2.4 m3.d-1、水温为13-16℃、原水ρ(CODCr)为66.46-107.82 mg·L-1、ρ(氨氮)为22.15-30.68 mg·L-1的水质特征条件下,系统对CODCr和氨氮的去除率分别为36.08%-50.37%和76.98%-93.56%。其中,碳氧化段以去除有机物为主,硝化段以去除氨氮为主;系统中硝酸氮质量浓度明显升高,无亚硝氮的积累;装置对总氮的平均去除率为19.56%,可以认为总氮的去除是同步硝化反硝化的结果。系统中pH值有所变化但维持在7-8之间,其中碳氧化段pH值升高,硝化段pH值下降。系统对有机物和氨氮良好的去除效果为后续进一步的生物处理提供了条件。  相似文献   

11.
新型生物脱氮技术的工艺研究   总被引:28,自引:0,他引:28  
以上流式厌氧污泥床反应器( U A S B) 作为厌氧氨氧化(anam mox) 反应器,用无机盐培养液完成了反应器的启动,并稳态运行anam mox 反应器.采用生物膜反应器作为生物硝化反应器,以无机盐培养液完成反应器的启动.将硝化反应器和anammox 反应器组合在一起构成新型生物脱氮系统,以硝化反应器的出水作为anammox反应器的进水,同时补充相应数量的 N H4 + N.整个系统的总氮容积去除率可达1 577 mg L- 1 d - 1 .该新型生物脱氮系统能同时去除 N H4 + N 和 N O X- N,并且对高浓度的 N H4 + N 去除具有较大的潜力.  相似文献   

12.
扰动对水体富营养化的改善作用   总被引:1,自引:0,他引:1  
利用人工构建的模拟水体系统,观察搅拌和曝气条件下水体中氮磷含量和形态的变化规律,研究和探讨了扰动对水体富营养化的改善。结果表明:(1)扰动对上覆水体氮的去除效果不明显,但是能够有效促进底泥中氨氮向水体扩散,从而使底泥中氮含量明显降低,运行99 d后,曝气反应器中底泥总氮含量从初始3.46 g.kg-1降至0.68 g.kg-1,仅为对照反应器的1/4;(2)搅拌对上覆水中磷的去除效果最佳,反应器运行期间,总磷的平均去除率为37%左右;(3)扰动能增加底泥中微生物的数量和多样性,为污染物的生物降解提供了良好的基础。合理运用扰动能够提高水中溶解氧含量,改善微生态环境,增加微生物的数量和种类,有利于水体富营养化的改善。  相似文献   

13.
In this paper, a study was conducted on the effect of polyhydroxyalkanoates (PHA) and glycogen transformations on biologic nitrogen and phosphorus removal in low dissolved oxygen (DO) systems. Two laboratory-scale sequencing batch reactors (SBR1 and SBR2) were operating with anaerobic/aerobic (low DO, 0.15–0.45 mg·L-1) configurations, which cultured a propionic to acetic acid ratio (molar carbon ratio) of 1.0 and 2.0, respectively. Fewer poly-3-hydroxybutyrate (PHB), total PHA, and glycogen transformations were observed with the increase of propionic/acetic acid, along with more poly-3-hydroxyvalerate (PHV) and poly-3-hydroxy-2-methyvalerate (PH2MV) shifts. The total nitrogen (TN) removal efficiency was 68% and 82% in SBR1 and SBR2, respectively. In the two SBRs, the soluble ortho-phosphate (SOP) removal efficiency was 94% and 99%, and the average sludge polyphosphate (poly-P) content (g·g-MLVSS-1) was 8.3% and 10.2%, respectively. Thus, the propionic to acetic acid ratio of the influent greatly influenced the PHA form and quantity, glycogen transformation, and poly-P contained in activated sludge and further determined TN and SOP removal efficiency. Moreover, significant correlations between the SOP removal rate and the (PHV+ PH2MV)/PHA ratio were observed (R2>0.99). Accordingly, PHA and glycogen transformations should be taken into account as key components for optimizing anaerobic/aerobic (low DO) biologic nitrogen and phosphorus removal systems.  相似文献   

14.
In this study, the performance of nitrogen and phosphorus removal in a full-scale closed-loop bioreactor (oxidation ditch) system was simulated using the ASM2d model. Routine data describing the process for two years were compiled for calibration and validation. To overcome the identifiability problem, the classic Bayesian inference approach was utilized for parameter estimation. The calibrated model could describe the long-term trend of nutrient removal and short-term variations of the process performance, showing that the Bayesian method was a reliable and useful tool for the parameter estimation of the activated sludge models. The anoxic phosphate uptake by polyphosphate accumulating organisms (PAO) contributed 71.2% of the total Poly-P storage, which reveals the dominance of denitrifying phosphorus removal process under the oxygen limiting conditions. It was found that 58.7% of the anoxic Poly-P storage and denitrification by PAO in the reactor was achieved in the aerated compartment, implying that the PAO’s anoxic activity was significantly stimulated by the low dissolved oxygen (DO) level in this compartment due to the oxygen gradient caused by brush aerator.  相似文献   

15.
The effects and mechanism of chemical oxygen demand (COD), nitrogen, and phosphorus concentration removal by an integrated vertical-flow constructed wetland were studied in the wetland system during one inlet–outlet operating period, in two typical stages (each stage is connective 24 h, sampled once every 4 h). The concentration of ammonia decreased along the flow direction in the system, while levels of nitrate (NO3?-N) increased. In one operating period, total nitrogen (TN) concentration fell with rising operation time due to evacuative reoxygenation. The TN and NH3-N removal rates in the system were 26.6% and 97.5%, respectively. COD decreased rapidly in the early stages and more gradually in the direction of water flow of the wetland system. Average total phosphorus (TP) removal rate was 20.71%. TN and NO3?-N levels in water of the wetland had a tendency to decline gradually with increasing operation time. Ammonia concentrations displayed only a small variation with operation time. The results also indicated that the wetland was able to maintain its temperature. The oxygen content differed during the various operating stages and exerted a marked influence on COD, TP, and TN removal.  相似文献   

16.
To improve the efficiency of nitrogen removal with lower energy consumption, the study of feedforward control was carried out on a pilot-scale anaerobic-anoxic-oxic (AAO) plant for the treatment of municipal wastewater. The effluent qualities of the pilot plant under different control strategies were investigated. The results indicated that the change of external recycle was not a suitable approach to regulate the sludge concentration of plug-flow reactors; adjusting the aeration valve and dissolved oxygen set-point according to ammonia load could overcome the impact of influent fluctuation; and the denitrification potential could be estimated based on the transit time of anoxic zone and the relative content of carbon resource entering the anoxic zone. Simple feedforward control strategies for aeration and internal recycle were subsequently proposed and validated. The nitrogen removal was successfully improved in the pilot plant. The effluent total nitrogen had decreased by 29.9% and was steadily controlled below 15 mg·L-1. Furthermore, approximately 38% of the energy for aeration had been saved.  相似文献   

17.
• PN-A was start-up under low inoculation amount and a higher NRR was achieved. • PN-anammox system was successfully restored by aggressive sludge discharge. • Increase in granular sludge was the important factor to rapid recovery. • Enrichment of AOB and AnAOB in granular sludge favors the stable operation. Partial nitritation (PN)-anaerobic ammonium oxidation (anammox) is a promising pathway for the biological treatment of wastewater. However, the destruction of the system caused by excessive accumulation of nitrate in long-term operation remains a challenge. In this study, PN-anammox was initialized with low inoculation quantity in an air-lift reactor. The nitrogen removal rate of 0.71 kgN/(m3·d) was obtained, which was far higher than the seed sludge (0.3 kgN/(m3·d)). Thereafter, excess nitrate build-up was observed under low-loading conditions, and recovery strategies for the PN-anammox system were investigated. Experimental results suggest that increasing the nitrogen loading rate as well as the concentration of free ammonium failed to effectively suppress the nitrite oxidation bacteria (NOB) after the PN-anammox system was disrupted. Afterwards, effluent back-flow was added into the reactor to control the up-flow velocity. As a result, an aggressive discharge of sludge that promoted the synergetic growth of functional bacteria was achieved, leading to the successful restoration of the PN-anammox system. The partial nitritation and anammox activity were in balance, and an increase in nitrogen removal rate up to 1.07 kgN/(m3·d) was obtained with a nitrogen removal efficiency of 82.4% after recovery. Besides, the proportion of granular sludge (over 200 mm) increased from 33.67% to 82.82%. Ammonium oxidation bacteria (AOB) along with anammox bacteria were enriched in the granular sludge during the recovery period, which was crucial for the recovery and stable operation of the PN-anammox system.  相似文献   

18.
从生物陶粒反应器中筛选出6株异养硝化细菌,将异养硝化细菌扩大培养后,建立SBR反应器并进行了氨氮去除的试验研究。在SBR反应器进入稳定运行阶段时,可以观察到系统对于氨氮的去除率稳定在82.96%左右,表现出较好的氨氮去除效果;出水亚硝酸盐含量一直维持在较低的水平,其最大值不超过3.84mg·L-1;COD的平均去除率为54.72%,基本实现了同一反应器中的有机物和氨氮的共同去除。异养硝化SBR反应器温度为29℃时,反应器对氨氮和总氮的去除能力最大为82.28%和47.27%;在pH值为8.0时,氨氮去除率最高达到80.15%。C/N〈4.5时,随着C/N比的增加,氨氮和总氮的去除率快速增加;在C/N为6时,氨氮去除率最高达到87.62%。  相似文献   

19.
中国水稻土氮密度变异性的幅度效应研究   总被引:2,自引:0,他引:2  
基于全国第二次土壤普查的1 491个水稻土剖面数据,研究了行政区幅度(行政大区、省级、地区级)和土壤区幅度(土壤区、土壤带、土区)下水稻土氮密度的变异情况及其对幅度拓展的响应。结果表明,中国水稻土0-20 cm和0-100 cm土壤平均氮密度为18.7 t.hm^-2和12.4 t.hm^-2,土壤氮素的空间变异性总体随幅度拓展而增大。在不同土壤区幅度下,0-20 cm全氮密度组内和组间变异性随研究区幅度的减小而减小;从土壤区到土区尺度,0-100 cm全氮密度组间变异率从250%左右下降至不足50%,而在行政大区和省级尺度时全氮密度的组间变异性没有太大变化,变异率都小于100%,到地级市尺度时,组间变异率又达到了400%,说明同一地区所选择的研究幅度尺度不一样氮密度变异率差异也很大。因此,在今后的水稻土调查采样设计时,根据不同幅度尺度的变异率大小来选择合适的布点方式和样点数是十分必要的。  相似文献   

20.
针对NH3-N浓度为1mg.l-1的饮用原水,分别以硅锰砂石和聚胺脂海绵作为硝化生物膜载体,考察了自制固定床生物膜反应器的脱氨效果.30d的连续运行结果表明,砂石载体系统达到95%—100%的NH3-N去除率,出水NH3-N浓度接近0,出水NO2--N浓度在0—0.02mg.l-1之间;而海绵载体系统虽然挂膜快,但运行阶段NH3-N去除率仅为10%—35%,出水NH3-N不能达标,且具有生物可降解性,反硝化过程优先导致NO2--N的积累.进一步考察了硅锰砂石生物膜系统稳定运行的最优参数,得出试验条件下,水力停留时间为6min,气水比为1:1,反冲洗周期为6d.硅锰砂石因其良好的孔隙率、粒径分布和密度等物理特性,以及化学稳定性和生物安全性,是含低浓度NH3-N原水生物膜净化的良好载体选择.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号