首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
考察了不同进水有机物浓度下厌氧/好氧序批式移动床生物膜反应器(SBMBBR)污染物去除特性,实验结果表明,SBMBBR能够实现低碳源污水中氮和磷的同步去除,在进水TN和TP浓度分别为116.7 mg.L-1和11.5 mg.L-1、COD浓度为456 mg.L-1的条件下,TN和TP去除率分别达到94.3%和92.2%以上.反应器除磷是基于常规生物除磷和反硝化除磷过程实现的,脱氮主要是基于好氧段发生的同时硝化反硝化(SND)作用而完成.由于生物膜内部存在的DO扩散梯度,在好氧阶段混合液DO浓度不断提高的条件下反应器内具有良好SND反应的发生.进水COD浓度由149 mg.L-1提高至456 mg.L-1的过程中,反应器硝化效果不变,反硝化和除磷效果改善.反应器在好氧阶段pH值基本维持在7.0—7.1之间,为各类菌群的生长创造了条件.碱度变化较pH值更能反映硝化和反硝化反应发生的程度.反应器中微生物相丰富,生物膜以丝状菌为骨架,其上附着大量的球状菌和杆状菌,而悬浮活性污泥中丝状菌较少,形成了由细菌、真菌到原生动物和后生动物的复杂的生态体系,为系统取得稳定的污水处理效果提供了有效的保证.  相似文献   

2.
Optimization of an integrated anaerobic-aerobic bioreactor (IAAB) treatment system for the reduction of organic matter (Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) concentrations) in Palm Oil Mill Effluent (POME) to legal standards with high methane yield was performed for the first time under thermophilic condition (50°C–55°C) by using response surface methodology (RSM). The experiments were conducted based on a central composite rotatable design (CCRD) with three independent operating variables, organic loading rates in anaerobic compartment (OLRan) and mixed liquor volatile suspended solids (MLVSS) concentration in anaerobic (MLVSSan) and aerobic compartments (MLVSSa). The optimum conditions for the POME treatment were determined as OLRan of 15.6 g COD·L-1·d-1, MLVSSan of 43100 mg·L-1, and MLVSSa of 18600 mg·L-1, where high aerobic COD, BOD and TSS removal efficiencies of 96.3%, 97.9%, and 98.5% were achieved with treated BOD of 56 mg·L-1 and TSS of 28 mg·L-1 meeting the discharge standard. This optimization study successfully achieved a reduction of 42% in the BOD concentrations of the final treated effluent at a 48% higher OLRan as compared to the previous works. Besides, thermophilic IAAB system scores better feasibility and higher effectiveness as compared to the optimized mesophilic system. This is due to its higher ability to handle high OLR with higher overall treatment efficiencies (more than 99.6%), methane yield (0.31 L CH4·g-1 CODremoved) and purity of methane (67.5%). Hence, these advantages ascertain the applicability of thermophilic IAAB in the POME treatment or even in other high-strength wastewaters treatment.  相似文献   

3.
Actual pharmaceutical wastewater was treated using a combined ultrasonic irradiation (US) and iron/coke internal electrolysis (Fe/C) technology. A significant synergetic effect was observed, showing that ultrasonic irradiation dramatically enhanced the chemical oxygen demand (COD) removal efficiencies by internal electrolysis. The effects of primary operating factors on COD removal were evaluated systematically. Higher ultrasonic frequency and lower pH values as well as longer reaction time were favorable to COD removal. The ratio of biochemical oxygen demand (BOD) and COD (B/C) of the wastewater increased from 0.21 to 0.32 after US-Fe/C treatment. An acute biotoxicity assay measuring the inhibition of bioluminescence indicated that the wastewater with overall toxicity of 4.3 mg-Zn2+·L-1 was reduced to 0.5 mg-Zn2+·L-1 after treatment. Both the raw and the treated wastewater samples were separated and identified. The types of compounds suggested that the increased biodegradability and reduced biotoxicity resulted mainly from the destruction of N,N-2 dimethyl formamide and aromatic compounds in the pharmaceutical wastewater.  相似文献   

4.
This study aimed to investigate the effects of humic acid (HA) on residual Al control in drinking water facilities that used orthophosphate addition. The results showed that adding orthophosphate was an effective method for residual Al control for the raw water without HA. When orthophosphate was added at 1.0 min before the addition of poly aluminum chloride (PACl), the concentrations of soluble aluminum (Sol-Al) and total aluminum (Tot-Al) residue were 0.08 and 0.086 mg·L-1, respectively; both were reduced by 46% compared with the control experiment. The presence of HA would notably increase the residual Al concentration. For the raw water with 5 mg·L-1 of HA, the concentrations of Sol-Al and Tot-Al increased from 0.136 and 0.174 mg·L-1 to 0.172 and 0.272 mg·L-1, respectively. For water with a HA concentration above 5 mg·L-1, orthophosphate was ineffective in the control of residual Al, though there were still parts of orthophosphate were removed in coagulation. The amounts of Al removal were positively correlated with the solids freshly formed in coagulation. Similar to the raw water without HA, the best Al control was obtained with orthophosphate salt added at 1.0 min before PACl. HA concentrations in the raw water, solution pH, and the orthophosphate dosage suitable for residual Al control by orthophosphate precipitation were also investigated.  相似文献   

5.
序批式膜反应器处理高氨氮渗滤液同步硝化反硝化特性   总被引:1,自引:1,他引:0  
应用序批式生物膜反应器(SBBR)处理实际垃圾渗滤液,在DO浓度分别为0.45mg.l-1和1.19mg.l-1条件下,研究了系统的有机物,氨氮和总氮去除特性以及游离氨(FA),DO对系统同步硝化反硝化(SND)类型的影响.250d试验研究表明:SBRR系统能够稳定高效地同步去除渗滤液内高浓度有机物和高浓度氨氮.在初始COD浓度为122—2385 mg.l-1的情况下,出水COD浓度为23—929 mg.l-1,有机物最大去除速率25.6 kgCOD.m-2载体.d-1.在初始NH4+-N浓度为40—396.5 mg.l-1的情况下,出水NH4+-N浓度为0—41.2 mg.l-1,最大硝化速率2.87 kgN.m-2载体.d-1.SBBR系统内发生了明显的同步硝化反硝化(SND)现象,TN平均去除率分别为73.8%(DO=0.45 mg.l-1)和30%(DO=1.19 mg.l-1)左右.当FA浓度在1.5—11.6 mg.l-1范围内时,系统中共存硝酸型SND和亚硝酸性SND.当FA从18.6 mg.l-1增加到56 mg.l-1,系统中形成稳定的亚硝酸SND.因此,FA是影响系统SND类型的主要因素,DO可促进亚硝酸性SND向硝酸型SND转化.  相似文献   

6.
Based on the anoxic/oxic (A/O) step feed process, a modified University of Cape Town (UCT) step feed process was developed by adding an anaerobic zone and adjusting sludge return pipeline. Performance evaluation of these two types of processes was investigated by optimizing operational parameters, such as the anaerobic/anoxic/oxic volumes, internal recycle ratios, and sludge retention times, for removal of chemical oxygen demanding (COD), nitrogen, and phosphorus. Results showed high removal efficiencies of COD of (85.0±1.7)%, ammonium of (99.7±0.2)%, total nitrogen (TN) of (85.5±1.7)%, phosphorus of (95.1±3.3)%, as well as excellent sludge settleability with average sludge volume index of (83.7±9.5) L·mg-1 in the modified UCT process. Moreover, (61.5±6.0)% of influent COD was efficiently involved in denitrification or phosphorus release process. As much as 35.3% of TN was eliminated through simultaneous nitrification and denitrification process in aerobic zones. In addition, the presence of denitrifying phosphorus accumulating organisms (DNPAOs), accounting for approximately 39.2% of PAOs, was also greatly beneficial to the nitrogen and phosphorus removal. Consequently, the modified UCT step feed process was more attractive for the wastewater treatment plant, because it had extremely competitive advantages such as higher nutrient removal efficiencies, lower energy and dosages consumption, excellent settling sludge and operational assurance.  相似文献   

7.
A pilot-scale anaerobic ammonia oxidation (ANAMMOX) reactor was used to treat mixed wastewater resulting from a chlortetracycline and starch production process. The results, collected over the course of 272 days, show that the ratio of influent ammonium to nitrite, pH, and temperature can all affect the efficiency of nitrogen removal. The ratio of influent ammonium to nitrite was maintained at about 1:1 at a concentration below 200 mg·L-1 for both influent ammonium and nitrite. The total nitrogen (TN) loading rate was 0.15–0.30 kgN·m-3·d-1, pH remained at 7.8–8.5, and temperature was recorded at 33±1°C. The rate of removal of ammonia, nitrite, and TN were over 90%, 90%, and 80%, and the effluent ammonium, nitrite and TN concentrations were below 50, 30, and 100 mg·L-1.  相似文献   

8.
A low pH, ethanol-type fermentation process was evaluated for wastewater treatment and bio-hydrogen production from acidic beet sugar factory wastewater in a continuous stirred tank reactor (CSTR) with an effective volume of 9.6 L by anaerobic mixed cultures in this present study. After inoculating with aerobic activated sludge and operating at organic loading rate (OLR) of 12 kgCOD?m-3·d-1, HRT of 8h, and temperature of 35°C for 28 days, the CSTR achieved stable ethanol-type fermentation. When OLR was further increased to 18 kgCOD?m-3·d-1 on the 53rd day, ethanol-type fermentation dominant microflora was enhanced. The liquid fermentation products, including volatile fatty acids (VFAs) and ethanol, stabilized at 1493 mg·L-1 in the bioreactor. Effluent pH, oxidation-reduction potential (ORP), and alkalinity ranged at 4.1–4.5, -250–(-290) mV, and 230–260 mgCaCO3?L-1. The specific hydrogen production rate of anaerobic activated sludge was 0.1 L?gMLVSS-1·d-1 and the COD removal efficiency was 45%. The experimental results showed that the CSTR system had good operation stability and microbial activity, which led to high substrate conversion rate and hydrogen production ability.  相似文献   

9.
低碳氮比(C/N)废水处理是含氮废水处理中的难题之一.本实验在C/N为4:1和2:1(COD和NH4+-N浓度分别为400 mg·L-1和100 mg·L-1,400 mg·L-1和200 mg·L-1)条件下,考察好氧颗粒污泥系统对低碳氮比废水的处理效果、长期运行稳定性,研究C/N对好氧颗粒微生物结构变化的影响.研究结果表明,在C/N为4:1的废水中接种活性污泥培养好氧颗粒污泥,形成的颗粒沉降性能良好,MLSS为4.94 g·L-1,SVI30为40 mL·g-1,COD去除率90%以上,氨氮去除率接近100%.降低碳氮比,即C/N为2:1后,好氧颗粒的物理及硝化性能无明显变化,MLSS为11.38 g·L-1,SVI30/SVI5维持在1左右,COD去除率大于85%,氨氮去除率98%.碳氮比降低使颗粒微生物多样性减少,其中陶厄氏菌受影响较小,而硝化功能菌出现更替:噬氢菌、食酸菌、里德拜特氏菌消失,鞘氨醇单胞菌、束缚杆菌等成为优势菌种.实验表明,该低碳氮比条件下好氧颗粒污泥系统能够稳定运行,且具有优良的处理性能.  相似文献   

10.
The unexpected emergent discharge of high-arsenic wastewater into water environments results in significantly increased levels of arsenic in water; however, the species distribution of arsenic in sediments has never been reported before for such cases. This study focuses on an As pollution accident in the Dasha River, and uses sequential extraction procedures with deionized water, 1?mol·L-1 MgCl2 at pH= 8, 1?mol·L-1 NaH2PO4 at pH= 5, and 1?mol·L-1 HCl to investigate four binding phases of arsenic (i.e., water soluble, ion-exchangeable, strongly-bound, and precipitates) in sediments at different layers in different cross-sections along the river. The average ratio of arsenite (As(III)) to arsenate (As(V)) was found to decrease from 0.74:1 in river water to 0.48:1 in sediment, owing to its higher affinity toward As(V) than As(III). The content of arsenic in the sediments was relatively low and the maximum content was observed to be 36.3?mg·kg-1 for As(III) and 97.5?mg·kg-1 for As(V). As(III) and As(V) showed different binding phases in sediments, and the average fractions of these four species were determined to be 0.09, 0.11, 0.17, and 0.63 for As(III) and 0.03, 0.14, 0.63, and 0.20 for As(V), respectively. For all the sediment samples, the content of arsenic showed no relationship with the characteristics of the sediments such as the particle diameter, the content of organic carbon, Fe, and Mn, although a negative correlation with particle diameter was observed for the sediments in the uppermost 2-cm layer. The unexpected emergent As incident results in the high content of total arsenic in the surface sediment, which may be potential secondary source to the elevated As levels in surface water.  相似文献   

11.
封羽涛  吴为中 《生态环境》2011,(6):1127-1132
为了解决低有机污染高氮素水中由于低碳氮比而造成的后续脱氮问题,通过设反应填充床,外加固相碳源,对比了2种可降解聚合物PBS和PCL的反硝化效果。结果表明,(1)在进水TN质量浓度维持在14.33~18.31 mg.L-1,HRT为15.6 min时,PBS填充床平均TN去除率为94.93%,高于PCL填充床。(2)PBS填充床平均反硝化速率为13.55 mg.L-1.h-1(以N计),高于PCL填充床的9.07 mg.L-1.h-(1以N计)。(3)PBS填充床NO3-N、NO2-N、NH3-N的出水质量浓度分别维持在0.37~0.87、0~0.20、0.01~0.07 mg.L-1,优于PCL填充床。(4)PBS和PCL颗粒表面附着的微生物以杆菌为主,伴有少量的弧菌。该研究为日后新型固相碳源的开发提供了科学依据。  相似文献   

12.
在接种了反硝化菌的剩余污泥中投加硝酸钙药剂,利用反硝化菌消耗NO3-进行反硝化作用去除污泥中易生物降解的有机物,利用Ca2+的中和、架桥作用,改善污泥的脱水性能.固定NO;总投加浓度为100 mg?g-1 TS,在6d的时间内,按1次、2次、3次、6次的投加频次向污泥中投加硝酸钙.结果表明,1次投加对污泥脱水性能的提升...  相似文献   

13.
王滢  邓阳  陈男  胡伟武  冯传平 《环境化学》2022,41(1):365-375
作为一种典型的硝酸盐污水,低碳氮比硝酸盐污水的存在具有广泛性,且对生态环境和居民健康带来的危害日益突出.本研究构建了复合硫自养反硝化(CSAD)体系,基于硫-碳酸钙型复合材料与微生物,进行低碳氮比硝酸盐污水的深度处理,分析了材料投加量、粒径以及进水硝酸盐浓度对CSAD的影响,并探究了硝酸盐去除的动力学行为.结果 表明,...  相似文献   

14.
As the bioelectrochemical system, the microbial fuel cell (MFC) and the microbial electrolysis cell (MEC) were developed to selectively recover Cu2+ and Ni2+ ions from wastewater. The wastewater was treated in the cathode chambers of the system, in which Cu2+ and Ni2+ ions were removed by using the MFC and the MEC, respectively. At an initial Cu2+ concentration of 500 mg·L-1, removal efficiencies of Cu2+ increased from 97.0%±1.8% to 99.0%±0.3% with the initial Ni2+ concentrations from 250 to 1000 mg·L-1, and maximum power densities increased from 3.1±0.5 to 5.4±0.6 W·m-3. The Ni2+ removal mass in the MEC increased from 6.8±0.2 to 20.5±1.5 mg with the increase of Ni2+ concentrations. At an initial Ni2+ concentration of 500 mg·L-1, Cu2+ removal efficiencies decreased from 99.1%±0.3% to 74.2%±3.8% with the initial Cu2+ concentrations from 250 to 1000 mg·L-1, and maximum power densities increased from 3.0±0.1 to 6.3±1.2 W·m-3. Subsequently, the Ni2+ removal efficiencies decreased from 96.9%±3.1% to 73.3%±5.4%. The results clearly demonstrated the feasibility of selective recovery of Cu2+ and Ni2+ from the wastewater using the bioelectrochemical system.  相似文献   

15.
Metabolites of algae such as geosmin, 2-methylisoborneol etc. are reported to induce pungent odors into drinking water and attract additional scientific attention. Recently, in China, taste and odor outbreaks in drinking water supply have become increasingly common. In source water affected by eutrophication, dimethyl trisulfide, speculated to be produced by decayed algae, was found to be the source of taste and odor issues and can be removed effectively by usual oxidation agents. In this experimental study, batch scale tests were carried out focusing on the removal of dimethyl trisulfide. Reaction kinetics of dimethyl trisulfide oxidized by potassium permanganate in water had been studied; influence factors such as pH, organic substrate, other existed taste, and odor contaminant in equivalent concentration were also discussed. Results showed that dimethyl trisulfide can be removed by potassium permanganate efficiently; the ratio can reach more than 70% with oxidant dosage of 4 mg·L-1 and contact time prolonged to 120 min. The dimethyl trisulfide decomposition followed a second-order kinetics pattern with a rate constant k = 0.00213 L·(min·mg)-1. Typically, the degradation rate of dimethyl trisulfide was increased with the increasing KMnO4 dosage, but dramatically dropped with the increasing levels of humic acid (1.8–4.5 mg·L-1) and other odor-causing compounds (e.g. β-cyclocitral, 0–1886.0 μg·L-1). Solution pH (5.2–9.0) and initial dimethyl trisulfide concentration did not significantly affected the degradation. This study demonstrates that KMnO4 oxidation is an effective option to remove dimethyl trisulfide from water.  相似文献   

16.
In this study two types of biological contact oxidation processes (BCOP), a step-feed (SBCOP) unit and an inter-recycle (IBCOP) unit, were designed to investigate the treatment of heavily polluted river water. The Daqing River, which is the largest pollutant contributor to the Dianchi Lake, one of the most eutrophic freshwater lakes in China, was taken for the case study. It was found that the SBCOP had higher adaptability and better performance in the reduction of COD, TN, and TP, which made it applicable for the treatment of polluted river water entering the Dianchi Lake. Nitrification rate was observed to be greatly affected by the influent temperature. During each season, the nitrification in the SBCOP was higher than that in the IBCOP. TN removal efficiency in the SBCOP was higher than that in the IBCOP during the winter and spring but poorer during the summer, possibly due to the inhibition of denitrification by higher dissolved oxygen level in the summer. Moreover, symbiotic algaebacteria growth may be conducive to the removal of pollutants.  相似文献   

17.
The efficient removal of phosphorous from water is an important but challenging task. In this study, we validated the applicability of a new commercially available nanocomposite adsorbent, i.e., a polymer-based hydrated ferric oxide nanocomposite (HFO-201), for the further removal of phosphorous from the bioeffluent discharged from a municipal wastewater treatment plant, and the operating parameters such as the flow rate, temperature and composition of the regenerants were optimized. Laboratory-scale results indicate that phosphorous in real bioeffluent can be effectively removed from 0.92 mg·L-1 to<0.5 mg·L-1 (or even<0.1 mg·L-1 as desired) by the new adsorbent at a flow rate of 50 bed volume (BV) per hour and treatable volume of 3500–4000 BV per run. Phosphorous removal is independent of the ambient temperature in the range of 15°C–40°C. Moreover, the exhausted HFO-201 can be regenerated by a 2% NaOH+ 5% NaCl binary solution for repeated use without significant capacity loss. A scaled-up study further indicated that even though the initial total phosphorus (TP) was as high as 2 mg·L-1, it could be reduced to<0.5 mg·L-1, with a working capacity of 4.4–4.8 g·L-1 HFO-201. In general, HFO-201 adsorption is a choice method for the efficient removal of phosphate from biotreated waste effluent.  相似文献   

18.
The objective of this study is to investigate the occurrence of haloacetic acids (HAAs), a group of disinfection byproducts, in swimming pool and spa water. The samples were collected from six indoor pools, six outdoor pools and three spas in Pennsylvania, the United States, and from five outdoor pools and nine indoor pools in Beijing, China. Five HAAs (HAA5), including monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, and dibromoacetic acid were analyzed. Total chlorine, pH and total organic carbon concentration were analyzed as well. Results indicated that the levels of HAA5 in swimming pools and spas in the United States ranged from 70 to 3980μg·L^-1, with an arithmetic average at 1440μg·L^-1 and a median level at 1150μg·L^-1. These levels are much higher than the levels reported in chlorinated drinking water and are likely due to organic matters released from swimmers' bodies. The levels of HAA5 in swimming pools in China ranged from 13 to 332μg·L^-1, with an arithmetic average at 117μg·L^-1 and a median level at 114μg·L^-1. The lower HAA levels in swimming pools in China were due to the lower chlorine residuals. Results from this study can help water professionals to better understand the formation and stability of HAAs in chlorinated water and assess risks associated with exposures to HAAs in swimming pools and spas.  相似文献   

19.
The occurrence and removal of 13 antibiotics were investigated in five wastewater treatment plants (WWTPs) with advanced wastewater treatment processes in Beijing, China. Most of the target antibiotics were detected in the secondary and tertiary effluents, with the concentrations of 4.8-1106.0 and 0.3-505.0ng·L^-1. Fluoroquinolone antibiotics showed relatively high concentrations in all samples (782-1814ng·L^-1). Different tertiary treatment processes showed discrepant antibiotics removal performances. Ozonation process was found more effective in removing target antibiotics compared to the coagulation-flocculation-sedimentation process and sand filtration process. Investigation of the target antibiotics in three typical urban rivers in Beijing was carried out to understand antibiotics occurrence in surface water environment. Eight antibiotics were detected in the studied rivers, with highest concentration of antibiotics in the fiver which was mainly replenished by reclaimed water. This study showed the necessity of employing more effective advanced treatment facilities to further reduce the discharge amount of antibiotics.  相似文献   

20.
新型溴系阻燃剂(NBFRs,novel brominated flame retardants)作为传统溴系阻燃剂的替代品已广泛应用于电子产品、纺织品、家具等商品中,随着这些商品的生产、使用和处置,NBFRs不可避免地释放到环境中,给环境和人体带来潜在的危害.部分NBFRs可通过摄食和呼吸作用进入人体对人体产生一定危害...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号