首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
铁屑微电解法处理农药废水的研究   总被引:20,自引:1,他引:20  
铁屑微电解法能有效作农药(三唑磷、田安、杀虫双和单杀虫)生产废水中的CODcr、色度、As、氨氮、有机磷和总磷。去除率分别可达76.2%、80%、69.2%、55.7%、82.7%和62.8%;与铁盐混凝法相比,微电解法能更有效地去除污染物,提高废水的可生化性。  相似文献   

2.
采用微电解生物法组合工艺处理含铬电镀废水,在实验过程中,电镀废水中的重金属离子通过微电解法预处理可去除90%以上,剩余部分被后续工艺的微生物功能菌去除。实验结果表明对Cr6+含量为50mg/L,Cu2+含量为15mg/L,Ni2+含量为10mg/L的废水,经处理后,重金属离子的净化率达999%,且无二次污染。  相似文献   

3.
铁碳微电解/H_2O_2耦合类Fenton法深度处理制药废水   总被引:3,自引:0,他引:3  
采用铁碳微电解/H2O2耦合类Fenton法深度处理制药废水,考察不同铁碳比、H2O2投加量、溶液p H及反应时间对COD去除效果的影响,通过单因素实验和正交实验确定最优条件并与铁碳微电解法的去除效果进行对比。结果表明,各因素对COD的去除效果均呈现先增加后降低或趋于稳定的趋势,且对去除效果的影响顺序为:Fe/CH2O2投加量溶液p H反应时间;在固液比为1∶10的条件下,Fe/C(质量比)为1∶1,溶液p H为2.5,反应时间为60 min,H2O2(30%)投加量为12.24 mmol/L时对COD的去除效率最高,可达71.56%;H2O2对铁碳微电解法有显著的加强作用。  相似文献   

4.
强化微电解法预处理难降解农药废水   总被引:1,自引:0,他引:1  
为了更好地发挥微电解法预处理难降解农药废水的效能,对其进行强化研究。针对某难降解农药废水,考察了Cu/Fe双金属体系、Ni/Fe双金属体系、添加MnO2催化剂及超声波、电解与铁炭分别结合这5种强化途径去除COD的效果。结果表明,这5种强化途径对污染物的去除率分别为72.3%、68.0%、67.8%、70.0%和76.8%,相比于单独微电解,COD去除率均有较大提高。结合经济成本的考虑,镀Cu双金属微电解体系能够实现经济高效地预处理农药废水。  相似文献   

5.
微电解-生物法处理含铬电镀废水的研究   总被引:10,自引:0,他引:10  
采用微电解-生物法组合工艺处理含铬电镀废水,在实验过程中,电镀废水中的重金属离子通过微电解法预处理可去除90%以上,剩余部分被后续工艺的微生物功能菌去除。实验结果表明:对Cr^6 含量为50mg/L,Cu^2 含量为15mg/L,Ni^2 含量为10mg/L的废水,经处理后,重金属离子的净化率达99.9%,且无二次污染。  相似文献   

6.
微电解法强化生物脱氮的实验及反应特征分析   总被引:1,自引:1,他引:0  
通过铁炭微电解法强化SBR工艺脱氮效果的试验研究了解到,在进水中氨氮浓度分别为30、60和100 mg/L时,微电解-SBR工艺对氨氮的去除效果比独立的SBR工艺有明显的优势,去除率可以维持在95%左右.在进水中总氮浓度分别为30和60 mg/L时,微电解-SBR工艺对总氮的去除率比SBR工艺提高了20%~30%,利用DO-微小电极对铁污泥絮体及同样条件下的活性污泥内部物质变化进行测试,结果表明,微电解-SBR工艺所以能强化脱氮效果是微电解物化作用及后续铁污泥系统发生好氧同步硝化反硝化脱氮作用的共同结果.  相似文献   

7.
靛蓝牛仔布印染废水组分复杂,浓度高、水量大,属于难处理的工业废水,为了有效降低后续生物处理单元的负荷,采用铁炭微电解工艺对该废水进行预处理;通过正交实验考察pH、反应时间及铁炭比处理效果的影响规律及COD去除反应动力学,并对各因素作了单因素影响实验,确定了最佳工艺条件.结果表明,铁炭微电解法是预处理靛蓝牛仔布印染废水的一种有效方法,在Fe/C为2:1、pH为3的条件下反应90 min,铁炭微电解出水COD的去除率在49.2%,色度去除率达到80%,该印染废水经微电解处理后,BOD5/COD比值可从原来的0.248上升至0.436,可生化性明显提高.此外,微电解预处理靛蓝牛仔布印染废水中COD的去除反应符合二级反应动力学规律.  相似文献   

8.
TAIC(三烯丙基异氰脲酸酯)作为过氧化物交联或自由基反应交联的助交联剂被广泛应用。由于TAIC性质稳定难于生物降解,采用铁炭微电解法处理TAIC生产废水,并考察了铁炭比、进水pH值、反应时间对处理效果的影响,以及TAIC降解机理和反应动力学过程。结果表明,影响微电解工艺的因素主次关系为:pH>Fe/C质量比>反应时间;在最佳条件进水pH值为5,铁炭质量比为2:1,反应时间为135 min时,COD的去除率达到46%以上,TAIC的去除率达到48%以上。TAIC去除机理研究表明,微电解对TAIC废水的作用主要通过·H的还原和铁离子的絮凝作用,其中·H的还原作用是TAIC降解的主要原因。反应动力学分析表明,铁炭微电解法处理TAIC的降解过程基本符合二级反应动力学规律,通过建立模型并拟合出了TAIC降解的二级反应动力学方程。  相似文献   

9.
各种影响因子对电解法预处理医药废水的影响研究   总被引:2,自引:0,他引:2  
探讨了电解法预处理医药废水时停留时间、电解电压、废水初始浓度、温度和废水pH值等影响因子对去除色度、COD和提高废水可生化性等处理效果的影响,并考察了其应用于工业实际废水处理的可行性。实验结果表明:电解法更适合高浓度医药废水的处理,色度的去除率可达到90%以上;电解时间宜控制在40-60min;电解电压越高,废水COD和色度去除效果越好;在实验温度范围内,温度对色度和COD去除率的影响不大;废水pH值为7.5时电解效果最佳,工程运用宜控制在6—9之间。  相似文献   

10.
探讨了电解法预处理医药废水时停留时间、电解电压、废水初始浓度、温度和废水pH值等影响因子对去除色度、COD和提高废水可生化性等处理效果的影响,并考察了其应用于工业实际废水处理的可行性.实验结果表明:电解法更适合高浓度医药废水的处理,色度的去除率可达到90%以上;电解时间宜控制在40~60 min;电解电压越高,废水COD和色度去除效果越好;在实验温度范围内,温度对色度和COD去除率的影响不大;废水pH值为7.5时电解效果最佳,工程运用宜控制在6~9之间.  相似文献   

11.
污泥回流比对厌氧/好氧工艺除磷效果影响的研究   总被引:1,自引:0,他引:1  
以长距离输送的合流制污水为进水,考察不同污泥回流比下厌氧/好氧(A/O)工艺对COD、N、P的去除效果,深入研究污泥回流比对生物除P代谢过程的影响.结果表明,污泥回流比对COD及NH+4-N的去除没有明显影响,但对TN、TP、PO3-4-P的去除影响较大.随着污泥回流比的增大,聚磷菌(PAO)的厌氧释P量逐渐减小,P的去除率逐渐降低.减小污泥回流比,可延长A/O工艺厌氧池实际HRT,增加PAO在厌氧池可有效利用的碳源,使PAO在厌氧池充分释P,从而提高除P效率.  相似文献   

12.
The performance of the electrochemical oxidation process for efficient treatment of domestic wastewater loaded with organic matter was studied. The process was firstly evaluated in terms of its capability of producing an oxidant agent (H2O2) using amorphous carbon (or carbon felt) as cathode, whereas Ti/BDD electrode was used as anode. Relatively high concentrations of H2O2 (0.064 mM) was produced after 90 min of electrolysis time, at 4.0 A of current intensity and using amorphous carbon at the cathode. Factorial design and central composite design methodologies were successively used to define the optimal operating conditions to reach maximum removal of chemical oxygen demand (COD) and color. Current intensity and electrolysis time were found to influence the removal of COD and color. The contribution of current intensity on the removal of COD and color was around 59.1 and 58.8 %, respectively, whereas the contribution of treatment time on the removal of COD and color was around 23.2 and 22.9 %, respectively. The electrochemical treatment applied under 3.0 A of current intensity, during 120 min of electrolysis time and using Ti/BDD as anode, was found to be the optimal operating condition in terms of cost/effectiveness. Under these optimal conditions, the average removal rates of COD and color were 78.9?±?2 and 85.5?±?2 %, whereas 70 % of total organic carbon removal was achieved.  相似文献   

13.
针对垃圾渗滤液污染物浓度高、可生化性差等特点,采用准好氧矿化垃圾反应床+超声/芬顿联用技术对垃圾渗滤液进行预处理。准好氧矿化垃圾床处理后渗滤液中COD、氨氮、总磷、色度的去除率分别为80%、85%、92%和85%。通过单因素实验和正交实验,确定了超声/Fenton法最佳工艺条件。经该组合工艺后,渗滤液中COD、氨氮、总磷和色度的最高去除率分别可达96%、86%、94%和95%,且出水无臭,颜色为淡黄色,BOD5/COD从0.16增至0.35左右,可生化性基本满足后续生物处理需要,且COD、总磷这2个指标达到《生活垃圾填埋场污染控制标准》(GB16889—2008)规定的排放标准。  相似文献   

14.
提出以二级矿化垃圾床为预处理单元,串联三维电极/电Fenton处理老龄垃圾渗滤液的组合工艺。矿化垃圾床处理后渗滤液中COD、氨氮、总磷、色度的去除率分别为80.55%、88.47%、98.32%和87.53%。通过单因素实验和正交实验,确定了三维电极/电Fenton法最佳工艺条件。经该组合工艺后,渗滤液中COD、氨氮、总磷和色度的最高去除率分别可达97.08%、95.24%、99.55%和96.92%,其中COD、总磷、色度这3个指标低于《生活垃圾填埋场污染控制标准》(GB16889.2008)表2规定的排放标准,为该组合工艺在实际中的应用提供重要理论依据。  相似文献   

15.
针对Et处理量为1500m3的高校中水处理设施,论述了缺氧/好氧-MBR(A/O—MBR)处理工艺运行特性,完成了长效监测及经济性评价。系统MBR池污泥浓度(MLSS)控制在8~12g/L,缺氧池和好氧池水力停留时间(HRT)分别为3h和7h,污泥回流比为200%~300%。当进水COD、总氮、氨氮平均浓度分别为481.3、75.1和65.8mg/L时,出水COD、总氮、氨氮平均浓度分别为16.5、13.4和0.7mg/L,平均去除率分别为96.4%、81.9%和99.0%。在进行化学除磷的情况下,出水总磷的平均浓度为0.8mg/L,平均去除率86.5%。出水水质优于《城市污水再生利用城市杂用水水质》(GB/T18920—2002)中的相应水质指标要求。经济性分析结果显示,该中水站的电耗为0.58kWh/m3。  相似文献   

16.
铁炭微电解法处理拉开粉废水的研究   总被引:3,自引:0,他引:3  
就铁炭微电解法处理拉开粉废水的工艺参数及其处理效果进行了试验研究 ,采用絮凝沉淀 酸化微电解 中和沉淀流程 ,拉开粉和CODCr的总去除率可分别达到 87.7%和 83.4 %。  相似文献   

17.
试验研究了水性油墨废水的铁屑微电解法处理。研究结果表明,微电解条件控制在pH 4 0、铁屑投加量10%、反应时间60min、焦炭含量为16. 67%,水性油墨废水的处理效果较好,色度去除率可达90%以上,COD去除率在50%左右。  相似文献   

18.
水深对表面流人工湿地污染河水处理系统运行效果的影响   总被引:4,自引:0,他引:4  
基于中试系统一年的连续运行监测,研究了水深对芦苇表面流人工湿地污染河水处理系统的影响。结果表明,水深对表面流人工湿地污染河水处理系统运行效果有很大影响,在进水COD、氨氮、总氮和总磷等分别为36±4.46、0.92±0.47、6.27±2.01和0.13±0.05 mg/L条件下,水深50 cm时处理效果最好,COD、氨氮、总氮和总磷去除率分别达到42.75%、58.42%、56.94%和43.24%。综合污染物去除效果和人工湿地建设工程量,芦苇表面流人工湿地的水深宜采用50 cm。人工湿地系统中植物光合生理和溶解氧等研究表明,水深主要通过影响植物生长和溶解氧等而影响人工湿地的水质净化效果。  相似文献   

19.
两级混合稳定表流湿地处理生活污水   总被引:1,自引:1,他引:0  
为了提高一级稳定表流湿地(stable surface flow wetland,SSFW)的出水水质,在单级稳定表流湿地后串联一级潜流人工湿地,构成两级混合稳定表流湿地(two steps hybrid stable surface flow wetland,TSHSSFW),研究气候变化对其净化效果的影响,并同一级潜流人工湿地(one step subsurface flow wetland,OSSFW)进行对比。研究表明,气候变化对TSHSSFW的COD和总磷去除率影响较小,去除率均在80%左右;而对氨氮和总氮的去除率影响比较大,夏季TSHSSFW的氨氮和总氮去除率分别为87.77%和77.74%,而冬季氨氮和总氮的去除率分别为54.07%和48.84%。相比单级潜流人工湿地(OSSFW),有SSFW作为前处理的潜流人工湿地对氨氮和总氮的去除率较高。  相似文献   

20.
以人工配水为研究对象,采用厌氧/好氧/缺氧/好氧交替运行的序批式反应器,研究了(AO)2SBR系统同步脱氮除磷的效果,并结合批式实验讨论了同步脱氮除磷的反应机理。研究结果表明,该系统以厌氧1.5 h、好氧1 h、缺氧3h、好氧0.5 h的方式运行,在DO=2.5 mg/L,SRT=15 d的条件下,具有良好的脱氮除磷效果,配水中的总氮、总磷、COD和总有机碳的去除率分别为96.26%、99.87%、90.46%和85.57%。批式实验表明,合成的内碳源越多,氨氮的硝化越充分,反硝化除磷越多。  相似文献   