This paper describes a methodology used for designing louvered fins. Louvered fins are commonly used in many compact heat exchangers to increase the surface area and initiate new boundary layer growth. Detailed measurements can be accomplished with computational models of these louvered fins to gain a better understanding of the flow field and heat distribution. The particular louver geometry studies for this work have a louver angle of 23° and fin count of 17 fpi.

The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with louvered fins are analyzed numerically. A three-dimensional model is developed to investigate flow and conjugate heat transfer in the copper-based car radiator. The model was produced with the commercial program FLUENT. The theoretical model has been developed and validated by comparing the predictions of the model with available experimental data. The thermal performance and temperature distribution for the louvered fins were analyzed and a procedure for optimizing the geometrical design parameter is presented.

One fin specification among the various flat tube exchangers is recommended by first considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected radiator are investigated also. The results will be used as fundamental data for tube design by suggesting specifications for car radiator tubes.  相似文献   

2.
Energy, cost, and environmental concerns play a vital role in understanding governing parameters of distributor design in falling film evaporators. Distributor design is a hidden parameter in many experimental papers. The uniform distribution of liquid refrigerant over the tube bundle mostly depends on two-phase liquid refrigerant and vapor refrigerant. This work conducted experiments with two distribution systems with and without separation of liquid-vapor refrigerant after expansion valve for the same evaporator capacity with R134a as a refrigerant. Results reveal that; separating vapor refrigerant has a positive impact on the approach of the evaporator with an open system distributor arrangement. The highest delta T and lowest practice are found at a heat flux of 13.97 kW/m2 with an available system distributor compared to a closed system with a heat flux of 14.25 kW/m2. The open system arrangement in the distributor is the novel parameter for distributor design, ensuring uniform distribution with minimum pressure drop and dry suction. An open system distributor has an average 16.1% capacity increase over a closed system. The experimental analysis helps to understand different parameters for the design of distributors in falling film evaporators for uniform distribution.  相似文献   

3.
Conventional solar photovoltaic (PV) module converts the light component of solar radiation into electrical power, and heat part is absorbed by module increasing its operating temperature. Combined PV module and heat exchanger generating both electrical and thermal powers is called as hybrid photovoltaic/thermal (PV/T) solar system. The paper presents the design of a PV/T collector, made with thin film PV technology and a spiral flow absorber, and a simulation model, developed through the system of several mathematical equations, to evaluate the performance of PV/T water collectors. The effect of various parameters on the thermal and electrical efficiency has been investigated to obtain optimum combination of parameters. Finally, a numerical simulation has been carried out for the daily and annual yield of the proposed PV/T collector, and comparison with a standard PV module is discussed.  相似文献   

4.
The condenser is a piece of equipment used to effectively transfer heat from water to the environment. The fin and tube condenser is the most commonly used in commercial applications. The improved performance of heat transfer in the fin and tube condenser is a significant area of study all over the world because optimizing the efficiency of heat transfer in the condenser will contribute to enhancing the effectiveness of system performance. The vapor deposition, plasma spray, and thermal spray techniques are being used, and it is determined that a heat transfer enhancing coating improves condenser performance. This review discusses the nanomaterial coating over the fin and tube condenser in detail. The various nanomaterial coatings with various propositions and coating methods had been discussed with the evidence of previous researchers. At a 50-degree inclination angle on the condensate plate, the condensate over the coating surface increases by more than 30%. The thermal properties of the working fluid are improved over the condenser, and the overall effectiveness of the condenser is increased by approximately 40% over the non-coated condenser. A 1% volumetric concentration of Nanoparticles in the coated material achieves a maximum efficiency increase of 78.7%.  相似文献   

5.
A model is developed to predict the evaporative heat transfer coefficient in a horizontal tube-falling evaporator and has been applied to evaluate overall performance of a desalination unit. Performance variation with different parameters like operation temperature, type of water distribution system, mass flow rate of distilled water inside the exchanger are analyzed. It has been observed that the model is able to predict the trends of heat transfer characteristics of the evaporator reasonably well. However, at low liquid film flow rate conditions, the model overpredicts the heat transfer characteristics marginally. In order to improve the evaporative exchanger performance, it is observed that preheating of the liquid film before injection into the evaporator is desirable. Calculations are also performed to estimate the value of overall heat transfer coefficient for a typical desalination unit.  相似文献   

6.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   

7.
ABSTRACT

Aquaculture raceway temperature has a direct impact on the aquatic specie being reared. In regions that undergo significant seasonal temperature variations, the thermal management of the raceway temperature becomes a challenge, directly impacting the production yield. This study investigates a novel approach to regulate the raceway temperature in a sustainable way by utilizing geothermal energy. A numerical energy model was developed to simulate heat transfer in a geothermal system encompassing both the individual borehole heat exchangers and their thermal interactions. Simulations were conducted for different configurations of the geothermal system over a complete seasonal cycle. Results show that flow rate, number of boreholes and the borehole spacing influence the temperature of the fluid at the raceway inlet. An increase in the number of boreholes provided better thermal regulation but an increase in the flow rate through the boreholes provided less thermal regulation. A borehole spacing of 6 m was found to be appropriate to reduce thermal interference. It was also observed that an increase in the fraction of the fluid passed through the geothermal system enhances the overall thermal regulation, with higher thermal regulation at lower flow rates. Results show that when 100% of the fluid passed through a 64 boreholes geothermal system, the average regulated raceway inlet temperature was 23% higher in winter months and 16% lower in summer months at the flow rate of 21.5 L/s compared to than at 43 L/s.  相似文献   

8.
Abstract: The summertime heating of runoff in urban areas is recognized as a common and consistent urban climatological phenomenon. In this study, a simple thermal urban runoff model (TURM) is presented for the net energy flux at the impervious surfaces of urban areas to account for the heat transferred to runoff. The first step in developing TURM consists of calculating the various factors that control how urban impervious areas absorb heat and transfer it to moving water on the surface. The runoff temperature is determined based on the interactions of the physical characteristics of the impervious areas, the weather, and the heat transfer between the moving film of runoff and the impervious surface common in urban areas. Key surface and weather factors that affect runoff temperature predictions are type of impervious surface, air temperature, humidity, solar radiation before and during rain, rainfall intensity, and rainfall temperature. Runoff from pervious areas is considered separately and estimated using the Green‐Ampt Mein‐Larson rainfall excess method. Pervious runoff temperature is estimated as the rainfall temperature. Field measurements indicate that wet bulb temperature can be used as a surrogate for rainfall temperature and that runoff temperatures from sod average just 2°C higher than rainfall temperatures. Differences between measured and predicted impervious runoff temperature average approximately 2°C, indicating that TURM is a useful tool for determining runoff temperatures for typical urban areas.  相似文献   

9.
Abstract: A numerical model has been developed to simulate the hydraulic and heat transfer properties of a stormwater detention pond, as part of a simulation tool to evaluate thermal pollution of coldwater streams from stormwater runoff. The model is dynamic (unsteady) and based on principles of fluid mechanics and heat transfer. It is driven by hourly weather data, and specified inflow rates and temperatures. To calibrate and validate the pond model field data were collected on a commercial site in Woodbury, Minnesota. The relationship between pond inflow and outflow rates to precipitation was effectively calibrated using continuously recorded pond levels. Algorithms developed for surface heat transfer in lakes were found to be applicable to the pond with some modification, resulting in agreement of simulated and observed pond surface temperature within 1.0°C root mean square error. The use of an unshaded pond for thermal mitigation of runoff from paved surfaces was evaluated using the pond model combined with simulated runoff from an asphalt parking lot for six years of observed rainfall events. On average, pond outflow temperature was 1.2°C higher than inflow temperature, but with significant event‐to‐event variation. On average, the pond added heat energy to runoff from an asphalt parking lot. Although the pond added total heat energy to runoff, it did reduce the rate of heat outflow from the pond by an order of magnitude due to reductions in volumetric outflow rate compared with the inflow rate. By reducing the rate of heat flow, the magnitude of temperature impacts in a receiving stream were also reduced, but the duration of impacts was increased.  相似文献   

10.
The paper presents the novel design of double glazing helical coil solar cavity receiver for solar thermal applications. Performance model has been developed for the experimental setup based on energy balance equations. The results obtained were compared with horizontal tube receiver for the same experimental setup. The result shows that the 87.96% improvement in the convective heat transfer coefficient for the double glazing helical coil solar cavity receiver. Maximum conversion efficiency achieved is 21% more than that would be obtained for horizontal tube receiver. This paper also investigates how the quality of vacuum degraded with the temperature of the glass cover.  相似文献   

11.
This paper aims to reveal the heat transfer mechanism of low-temperature phase change material (PCM) and design PCM heat storage device in building heating environment. Firstly, low-temperature binary PCMs of lauric acid and stearic acid are prepared, and their thermal properties are investigated by DSC. Then, shell and tube latent heat thermal energy storage units are conducted, and heat transfer experiments are carried out to analyze the heat transfer mechanism of PCM. The results demonstrate that natural convection plays an important role in heat transfer process, and the heat storage efficiency of PCMs can be significantly enhanced by increasing the fin width and improving the inlet heat transfer fluid (HTF) temperature. Furthermore, some proposals are put forward to guide the design of PCM storage device in building heating environment.  相似文献   

12.
Understanding variation in stream thermal regimes becomes increasingly important as the climate changes and aquatic biota approach their thermal limits. We used data from paired air and water temperature loggers to develop region-scale and stream-specific models of average daily water temperature and to explore thermal sensitivities, the slopes of air–water temperature regressions, of mostly forested streams across Maryland, USA. The region-scale stream temperature model explained nearly 90 % of the variation (root mean square error = 0.957 °C), with the mostly flat coastal plain streams having significantly higher thermal sensitivities than the steeper highlands streams with piedmont streams intermediate. Model R 2 for stream-specific models was positively related to a stream’s thermal sensitivity. Both the regional and the stream-specific air–water temperature regression models benefited from including mean daily discharge from regional gaging stations, but the degree of improvement declined as a stream’s thermal sensitivity increased. Although catchment size had no relationship to thermal sensitivity, steeper streams or those with greater amounts of forest in their upstream watershed were less thermally sensitive. The subset of streams with three or more summers of temperature data exhibited a wide range of annual variation in thermal sensitivity at a site, with the variation not attributable to discharge, precipitation patterns, or physical attributes of streams or their watersheds. Our findings are a useful starting point to better understand patterns in stream thermal regimes. However, a more spatially and temporally comprehensive monitoring network should increase understanding of stream temperature variation and its controls as climatic patterns change.  相似文献   

13.
With the trend towards increasing the speed of processors in smaller sized of computers, there has been considerable interest in heat sink technologies with higher levels of performance and further miniaturization. This work addresses the fundamental heat transfer augmentation question of how to design a copper-based heat sink, when the overall dimensions of the bottom plate or fan are specified. A three-dimensional finite-volume model has been developed and applied to investigate flow and conjugate heat transfer in the copper-based heat sink. The model was produced with the commercial program FLUENT, which allows this nonlinear, highly turbulent problem to be simulated using the k-ε turbulence model. The theoretical model developed is validated by comparing the model predictions with available experimental data. The thermal performance and temperature distribution for the heat sink were analyzed and a procedure for optimizing the geometrical design parameters based on less space occupation and more efficient heat transfer coefficient is presented. Several design examples with different types of cooling methods and manufacturing processes have been analyzed. The reliability and effectiveness in heat spreading of those has been compared. It has been shown that the copper-based heat sink with louvered fins (case No.3) has an optimum design configuration.  相似文献   

14.
ABSTRACT: Water surface temperatures can be obtained from satellite thermal remote sensing. Landsat and other satellites sense emitted thermal infrared radiation on a regular basis over much of the earth's surface. Evaporation is accomplished by the net transport of mass from the water surface to the atmosphere. The evaporative transfer predominantly determines the water surface temperature. Hence, there should be good correlations between evaporation and surface temperatures. Previous investigations on Utah Lake with satellite-derived temperatures and pan- and model-derived evaporation values have produced good correlations. However, more study was required with additional satellite data and evaporation measurements for saltwater conditions. The applicability of this method for estimating evaporation on Utah's Great Salt Lake was of particular interest at this time because of the unprecedented rise of this terminal lake. Satellite thermal data and evaporation data from four different years were obtained for the Great Salt Lake and the surrounding region. More than 350 correlation and linear regression analyses were performed on the temperature and evaporation data. The lake salt concentrations were also factored into the analyses in several different ways. The correlation results were generally very good and a methodology for using satellite-derived water surface temperatures along with salt concentrations was developed to estimate evaporation.  相似文献   

15.
16.
An experimental study has been carried out to analyze the effect of inclined ribs used as roughness element on heat transfer along its friction characteristics. The roughness parameters include relative roughness pitch (P/e) ranges from 4–16, relative roughness height (e/Dh) ranges from 0.021–0.043 and angle of attack (α) ranges from 30° to 75°. The Reynolds number (Re) lies in the range of 4500–28000. The heat transfer and friction factor data obtained from the experiment and it is compared with the data obtained from smooth duct under the same conditions. Considerable augmentation was observed in heat transfer and friction over the smooth duct. Correlation was also developed for Nusselt number (Nu) and friction factor (f) as a function of roughness and flow parameter.  相似文献   

17.
ABSTRACT: Thermal energy storage involves the capture and storage of thermal energy (either heat or chill) during one time period for use at a later period. Storage of thermal energy in aquifers on a seasonal basis is one promising application of the technology that has been implemented in several foreign countries and is currently undergoing field testing in the U.S. Potential developers of aquifer thermal energy storage projects will face a number of regulatory requirements at the federal, state, and local level of government. These can include meeting: (1) surface land and ground water use restrictions, (2) regulations relating to withdrawal of ground water, and (3) requirements for reinjecting thermally altered ground waters. Separate permits for ground water withdrawal and reinjection may be required. The permit process is likely to involve opportunities for public comment and may involve contested proceedings.  相似文献   

18.
By establishing wind tunnel and employing electrical heating method, the heat transfer characteristics of flat plate were investigated under environmental wind condition. Both the uniform and linear heat flux boundary conditions were adopted for comparison purpose. Besides, the impacts of heat flux qwm, tilt angle α and wind incidence angle θ on heat transfer were explored in cases of windward and leeward facing positions. The local convection heat transfer coefficient hcx and average convection Nusselt number Nucm were obtained. The results show that, when α is small, there are two maximum values of hcx under linear heat flux boundary condition. As for Nucm, differences between the two boundary conditions seem indistinctive. At windward orientation, Nucm is not sensitive to α. While for leeward orientation, Nucm has a rapid decline progress with the increasing α, which indicates the tilt angle α is an important parameter to affect the heat transfer of plate. Finally, new correlations of Nucm have been developed, which were proven effective in engineering applications.  相似文献   

19.
Artificially roughened solar air heater has been topic in research for the last 30 years. Prediction of heat transfer and fluid flow processes of an artificially roughened solar air heater can be obtained by three approaches: theoretical, experimental, and computational fluid dynamics (CFD). This article provides a comprehensive review of the published literature on the investigations of artificially roughened solar air heater. In the present article, an attempt has been made to present holistic view of various roughness geometries used for creating artificial roughness in solar air heater for heat transfer enhancement. This extensive review reveals that quite a lot of work has been reported on design of artificially roughened solar air heater by experimental approach but only a few studies have been done by theoretical and CFD approaches. Finally this article presents a comparative study of thermo-hydraulic performance of 21 different types of artificial roughness geometries attached on the absorber plate of solar air heater in terms of thermo-hydraulic performance parameter. Heat transfer and friction factor correlations developed by various investigators for different types of artificially roughened solar air heaters have also been reported in this article.  相似文献   

20.
In this study, an innovative heat and mass transfer core is proposed to provide thermal comfort and humidity control using a hollow fiber contactor with multiple bundles of micro-porous hollow fibers. The hollow fiber-based core utilizes 12 bundles aligned vertically, each with 1,000 packed polypropylene hollow fibers. The proposed core was developed and tested under various operating and ambient conditions as a cooling core for a compact evaporative cooling unit and a dehumidification core for a liquid desiccant dehumidification unit. As a cooling core, the fiber-based evaporative cooler provides a maximum cooling capacity of 502 W with a wet bulb effectiveness of 85%. As a dehumidification core and employing potassium formate as a liquid desiccant, the dehumidifier is capable of reducing the air relative humidity by 17% with an overall dehumidification capacity of 733 W and humidity effectiveness of 47%. Being cheap and simple to design with their attractive heat and mass transfer characteristics and the corresponding large surface area-to-volume ratio, hollow fiber membrane contactors provide a promising alternative for cooling and dehumidification applications.  相似文献   