 共查询到20条相似文献,搜索用时 15 毫秒
1.
The relationship between the odor strength of total air samples and the odor strengths of the constituents was investigated in three field experiments in an office building and a new preschool. The odor strength was scaled by magnitude estimation according to a master scale principle which results in comparable values for the total and the constituent odors. Between 60 and 120 chemical components were detected by GC/FID in the indoor air samples (N = 66). Most (81%) of the detected components in an air sample were odorous, even though most of them were of the low concentrations. By a method of pattern analysis, chemical as well as odor patterns of indoor air were found to be characteristics of different buildings. From the odor patterns (POG), the “odor print” of the outdoor air associated with the buildings was also recognized in the indoor air. Thus, the “odor print” of an air sample is different from its “chemical print”. A model was found that predicts the overall odor strength of an air sample from the number of FID-detected components most frequently reported to have a strong odor.  相似文献   

2.
In a 30-m3 test chamber the air pollutants caused by man were measured. Variables were the number of persons and the rate of air change. During 2-h test sessions the temperature, relative humidity, carbon dioxide, and intensity of odors were measured. The relationship between the perceived odor intensities and the concentrations of carbon dioxide-independent of the number of persons and the air change rate—was observed. At air change rates of 12–15 m3/person/h, the carbon dioxide concentration was not higher than 0.15% and the odor intensity was evaluated only as a “slight annoyance.” Higher ventilation rates are necessary if smoking and increased physical activities are done in the rooms.  相似文献   

3.
Ventilation requirements in occupied spaces have traditionally derived largely from odor control. The requirements have rested on the notion that an environment that seems subjectively acceptable to a visitor will in fact be healthful and comfortable for both visitor and occupant alike. Ventilation requirements have derived secondarily from criterion concentrations of notable contaminants (e.g., carbon dioxide). The present investigation looked again at both sensory (odor, irritation) and physical criteria of acceptability, paying particular attention to the difference between smoking and nonsmoking occupancy in a well-controlled environmental chamber. More than 200 persons (visitors) made judgments of odor intensity and acceptability under various conditions of occupancy (up to 12 nonsmoking occupants; a temperature of up to 25.5°C; up to 16 cigarettes smoked per hour). The results implied that under nonsmoking conditions and moderate humidity only about 7.5 cfm (3.8 L sec−1) of fresh air per occupant sufficed to satisfy visitors, but that under smoking conditions at least 5 times as much fresh air is necessary. Our estimate of ventilation requirements for smoking were derived in part from measurements of carbon monoxide and total suspended particulate (TSP) mass concentration. Levels of TSP achieved during realistic smoking and ventilation rates exceeded levels deemed acceptable outdoors. Surfaces in the chamber played an important role in the elimination of particles, presumably via adsorption. Use of an electrostatic precipitator could keep TSP levels under control. Nevertheless, it remains to be seen whether control of TSP will eliminate the need for enormous ventilation for odor control during smoking occupancy.  相似文献   

4.
The air quality in a newly built preschool was investigated in a longitudinal study. Typical air contaminants emanating from building materials were determined, their variation over time (0–18 months) was measured, and the influence of the ventilation system (81%–91% recirculation of return air) on contaminant concentrations was studied. Volatile organic compounds were sampled by adsorption on porous polymer, analysed by a GC/FID system, and identified by MS. A spatial build-up in concentration (ppb or μg/m3 levels) is evident for all the organic compounds, as well as for CO2, from the outdoor air, through the ventilation system, and through the rooms to the exhaust air. The longitudinal comparison over time shows that all the organic compounds decline in concentration mainly within the first 6 months of occupancy: 1-butanol 4–14 times, toluene and pentanal + hexanal 2–4 times, while formaldehyde remained at a constant low level of 90 ppb (110 μg/m3). It is difficult to believe that the problems of poor air quality in 100 preschools in Stockholm are caused by the organic compounds alone unless interactions occur. A preschool building needs to be gassed off during the first 6 months after its construction with no recirculation of return air allowed (outdoor air rate approx 4–5 ach). During at least 1–2 additional years, it is desired that the recirculation rate of return air is restricted, perhaps to 50%.  相似文献   

5.
In this paper, the climate effect on the atmospheric radiocarbon concentration is estimated using the data, derived by using dendrochronologically dated tree ring samples, on sunspot number and global surface temperature during 1650–1800 A.D.; however, in order to use the data as a record of changes in radiocarbon production rate or cosmic ray intensity, the variations due to the geochemical process must be eliminated. The estimated influence of climate on the atmospheric radiocarbon concentration is 3–5 times greater than the direct contribution of the change of radiocarbon concentration through a Maunder minimum. The influence of climate on the atmospheric radiocarbon concentration through a transfer rate of CO2 between atmosphere and ocean was estimated at a rate of −13% per degree.The elimination of variations caused by climate and sunspot activities from the variations in atmospheric radiocarbon concentration gives a long time scale trend having a minimum and maximum which occur in about the seventh century A.D. and the sixth millennium suggesting a good correlation between this trend of variation and paleogeomagnetic data.  相似文献   

6.
The Akosombo dam was constructed on the Volta river primarily for the generation of hydropower. The resultant Volta lake which was formed between 1962 and 1966 in Ghana will probably long be one of the greatest man-made lakes. It produces 912MW of electricity at its maximum operating capacity. The Akosombo hydroelectric project (HEP) was meant among others to open up Ghana to rapid industrialization and hence modern development. Other positive impacts of the HEP include fishing, farming, transportation and tourism. However, there are equally negative impacts, some of which the project did not envisage and these are felt on the physical, biological and human subsystems within the immediate project environments and places much more distant from them. Recently, there have been declines in the lake levels resulting most probably from inadequate rainfall and/or runoff from the river catchments that feed the lake, and also from the observed rising temperatures. Comparisons of the runoff from two most important tributaries of the Volta (White Volta and Oti) for two time periods of 1951–1970 and 1971–1990 showed reductions in mean streamflows of 23.1% on the White Volta and 32.5% on the Oti. Similarly, a plot of the mean annual temperatures for the upper Volta basin indicated a 1^C rise in temperature from 1945–1993.  相似文献   

7.
Monitoring of 239,240Pu in surface air of Prague started in 1986 in connection with the Chernobyl accident. Measurable activities of 10–28 μBq m−3 were found from 29 April 1986 to 5 May 1986. In the most of the monitoring periods of 1987–1996, activities of 239,240Pu in air were not measurable. Positive values for 239,240Pu and 238Pu in air could be obtained after installation of an aerosol sampler with higher flow-rate in 1997. Activity concentrations of 239,240Pu and 238Pu in Prague air in the most of quarters of 1997–2006 were in the range 0.53–5.06 and <0.16–1.10 nBq m−3, respectively. Seasonal fluctuations can be found in content of 239,240Pu in air. Activity ratios of 238Pu/239,240Pu in air are higher than those in top soil, so it can be supposed that 238Pu is coming to air of Prague also from other sources than resuspension of fallout from atmospheric nuclear tests.  相似文献   

8.
Using miniature perfluorocarbon tracer (PFT) sources and miniature passive samplers, both about the size of a cigarette, tests conducted in the laboratory and in a typical home successfully demonstrated the utility of the PFT kit as a means for implementing wide-scale infiltration measurements in homes. The PFT diffusion plug source, an elastomer containing a dissolved perfluorocarbon compound, was shown to emit vapors at the rate of about 0.1 to 5 nL/min, providing steady-state concentrations in a home of about 1 to 10 pL/L, i.e., parts per trillion by volume, when one source is deployed for each 300–500 ft2 (28–46 m2) of living space. The emission rate from the diffusion source was predictable, but its dependence on both temperature and time suggested the development of alternative approaches. One such alternative, a liquid PFT permeation source, had emission rates which could be tailored over the range 10–20 nL/min, were independent of age for as long as the liquid remained ( 5 yr), and had significantly lower temperature dependence. A number of passive adsorption tube samplers performed reproducibly and identically (to within ±2%–3%) in laboratory tests. Together with a programmable tracer sampler, the miniature diffusion sources and samplers were deployed in a typical home; six PFT sources were uniformly deployed, three on each level of a two-story house. Multiple location sampling, as well as sampling in rooms with and without a miniature source, demonstrated that even in a house without forced-air circulation, a well-mixed modeling approach is justified. Analyses of the tracer samplers were performed back in the laboratory with an automatic electron-capture gas-chromatography system. The effects of the inside/outside temperature differential, as well as that of an open fireplace compared with a wood-burning stove, on the measured air infiltration rates were clearly demonstrated. Comparisons of the PFT tracer method with that of the SF6 tracer decay approach showed the results of the two methods to be identical within experimental precision. With this miniature source and sampling tracer kit, infiltration rates in the range 0.2–5 air changes per hour can be measured over time-averaged periods of as little as 1 day up to several years.  相似文献   

9.
The distribution of the anthozoan Metridium senile fibriatum on the rocky sublittoral of the Rimsky-Korsakov Islands at depths of 2–15 m has been investigated in relation to abiotic environmental factors. Together with the bivalve Crenomytilus grayanus, M. senile fibriatum dominates on rocky grounds in the upper sublittoral zone of open seaward coasts in the southern part of Peter the Great Bay. There is a significant dependence of its distribution on the intensity of water exchange and the bottom slope. The largest aggregations of M. senile fibriatum are found at depths over 10 m on vertical walls located at an acute angle or parallel to the prevailing directions of wave flows and in shallow gaping crevices with a stable direction of water flows. Anthozoans are absent from the rough rocky surface of the upper 5-m horizon and from relatively smooth walls exposed to wind waves at depths of less than 2 m. On the surfaces located at right angles to oncoming waves, the abundance of anthozoans drastically decreases.  相似文献   

10.
A new particle collection technique is analyzed and presented for its potential application in a high temperature, high pressure gas cleaning system. The technique is based on the collision and the aglomeration phenomena among the coal-ash particles when the cyclone is operated near the coal-ash fusion temperature. The percent increase of agglomeration rate is estimated by mathematical modeling for particles smaller than five microns in diameter. Particulate collection efficiency with or without agglomeration is presented. Experimental results in a high temperature cyclone are presented. The output dust loading varied from 0.025 to 5 grains per cubic foot (0.057–11 g/m3) as the input dust loading is increased from 4 to 35 grains per cubic foot (9.2–80g/m3) of gas flow.  相似文献   

11.
The effects of probable climate change—an increase in atmospheric CO2(by two times), air temperature, precipitation—on CO2exchange and temperature dependence of net photosynthesis in the larch and Siberian stone pine undergrowth formed in the light larch forests of West Siberia were studied in chambers with an artificial climate. The change of the aforementioned ecological factors caused an increase in the temperature optima of photosynthesis and the range of optimum temperatures (in the case of Siberian stone pine, to a slightly greater degree). Therefore, the ranges of both species may broaden, and the Siberian stone pine can expand to the north, displacing larch tree stands.  相似文献   

12.
A subcommittee of the Nordic Committee for Building Codes has released guidelines for building regulations regarding indoor air quality, especially concerning ventilation. The main features of the guidelines, such as acceptable outdoor air quality for ventilation and minimum outdoor air flows for dwellings and offices, are presented and discussed. Mechanical ventilation is, in principle, required in all buildings including dwellings, due to the requirement of a minimum outdoor air change of 0.5 h−1 and the normal highly airtight nature of new buildings. The guidelines are a basis for designing energy-efficient buildings while maintaining an indoor air quality which provides acceptable comfort and does not impair health.  相似文献   

13.
The results of long-term studies on plutonium distribution in the atmospheric air and plants in the area surrounding the Mayak Production Association in the years 1976–1995 are summarized. Data are presented on the changes in plutonium concentration in the air overtime at some points located in the survey zone and the impact zone of the industrial enterprise as compared to those in the control region. In addition, data on the changes in air plutonium concentration depending on the season and direction of wind are presented; the ratios between plutonium concentrations in the air and the fallout are analyzed.Translated from Ekologiya, No. 1, 2005, pp. 20–25.Original Russian Text Copyright © 2005 by Chudin, Shcherbakova, Maslovskii, Kocheva, Iovlev, Denisenko, Demin, Mamin, Chebotina.  相似文献   

14.
A standardized questionnaire was used in a two-year follow-up study to test the effectiveness of non-regulatory recommendations to improve indoor air quality of 103 ice arenas in Finland. In addition, the performance of a state-of-the-art emission control technology (ECT) on propane-fueled resurfacers was evaluated by measuring the one-week average nitrogen dioxide (NO2) concentration in a small sample of arenas. The number of retrofitted ECT on propane-fueled resurfacers increased from 6 to 37 (8% to 37% of ice arenas) and the number of electric resurfacers from 7 to 9 (both 9% of arenas) in 1994–1996. At the same time, the prevalence of inadequate ventilation increased among the most susceptible small arenas (volume <30 000 m3) from 11 (31%) to 19 (38%). Combustion-powered resurfacers (88%) and inadequate ventilation (24%) were prevalent also among the 17 new arenas built in 1994–1996. ECT resurfacers significantly decreased the mean indoor NO2 concentration of eleven arenas from 650 μg/m3 to 147 μg/m3. Thus, retrofitting resurfacers with ECT seems to be a feasible mitigation option to improve indoor air quality in ice arenas, but the ultimate solution is an electric ice resurfacer. Non-regulatory recommendations seem to be partially effective in abatement against the air quality problems, but additional regulatory measures are needed for full compliance in all arenas.  相似文献   

15.
Trihalomethanes (THMs) (chloroform, bromoform, dibromochloromethane, and bromodichloromethane) are the most abundant by-products of chlorination. People are exposed to THMs through ingestion, dermal contact and inhalation. The objective of this study was to compare two methods for assessing THM inhalation: a direct method with personal monitors assessing continuous exposure and an indirect one with microenvironmental sampling and collection of time–activity data during the main event exposures: bathing, showering and swimming. This comparison was conducted to help plan a future epidemiologic study of the effects of THMs on the upper airways of children. 30 children aged from 4 to 10 years were included. They wore a 3M 3520 organic vapor monitor for 7 days. We sampled air in their bathrooms (during baths or showers) and in the indoor swimming pools they visited and recorded their time–activity patterns. We used stainless steel tubes full of Tenax® to collect air samples. All analyses were performed with Gas Chromatography and Mass Spectrometry (GC-MS). Chloroform was the THM with the highest concentrations in the air of both bathrooms and indoor swimming pools. Its continuous and event exposure measurements were significantly correlated (rs = 0.69 p < 0.001). Continuous exposures were higher than event exposures, suggesting that the event exposure method does not take into account some influential microenvironments. In an epidemiologic study, this might lead to random exposure misclassification, thus underestimation of the risk, and reduced statistical power. The continuous exposure method was difficult to implement because of its poor acceptability and the fragility of the personal monitors. These two points may also reduce the statistical power of an epidemiologic study. It would be useful to test the advantages and disadvantages of a second sample in the home or of modeling the baseline concentration of THM in the home to improve the event exposure method.  相似文献   

16.
Management of an Agroecosystem   总被引:4,自引:0,他引:4  
Agroecosystems (AESs) are autotrophic ecosystems managed by man. The goal of the management is to obtain the maximum possible amount of high-quality agricultural products while preserving agricultural resources, primarily the soils and biodiversity. The main components of the management of AES structures and functions, including primary and secondary biological production, the ratio between the energy flows in the plant–man and plant–livestock–man food chains, the efficiency of energy transfer in the plant–livestock link, and conservation of agricultural resources, are considered.  相似文献   

17.
The state of gonads was analyzed in sea urchins Strongylocentrotus intermediuscollected in Amur Bay (Peter the Great Bay, the Sea of Japan) in August 1984, 1985, 1989, and 1997 at five stations: Skrebtsov Island (1), Sportivnaya Harbor (2), Cape Tokarevskii (3), Alekseev Bay on Popov Island (4), and Verkhovskii Islands (5). The first three stations were in the polluted inshore zone of Vladivostok; stations 4 and 5 were in the open (insular) part of the bay, remote from the main sources of pollution. The state of gonads of sea urchins collected in different years and areas strongly varied with respect to gonad index (GI), gonad maturity index, and indices of pathological changes in gonads. As compared with the data obtained in 1984, 1985, and 1989, the values of GI increased in sea urchins from stations 1–3 and decreased in sea urchins from stations 4 and 5. Although GI values were high, the indices of gonad maturity in animals from the coastal zone were very low. In general gonad maturity in sea urchins from the Amur Bay was lower in 1997 than in the previous years. The correlation analysis of long-term data revealed no positive correlation between the values of GI and gonad maturity index in sea urchins from stations 1–4. Histopathological changes were more serious in sea urchins from stations 1–3. In 1997, the indices of pathological changes in the gonads of sea urchins from the insular zone (stations 4 and 5) were higher than in the previous period (1984–1989). The influence of various ecological factors—temperature, salinity, environmental pollution, and food supply—on gametogenesis in sea urchins is discussed.  相似文献   

18.
The present field study addressed the need for a procedure that provides a defined unit of measurement of perceived annoyance from environmental odors, calibrating the estimates for individual scaling behavior and context effects. In including 25 subjects, the purpose was to demonstrate the applicability of the master-scale procedure with magnitude estimation to perform such a calibration of odor-annoyance estimates for target stimuli such as road-traffic combustion exhausts (13 000 vehicles/d; averaging 47 μg/m3 over the day/night with peaks exceeding 100 μg/m3 of nitrogen dioxide; NO2). For comparison, calibrated estimates were also obtained for a backyard expected to be considerably less polluted (comparable with 18 μg/m3 of NO2) and for blank stimuli presented indoors. The data transformation for the calibration procedure with which annoyance is expressed in either master-scale units or pyridine equivalents requires estimates of a reference stimulus for which seven concentrations of pyridine were used. The results provide an illustration of master scaling of odor annoyance, and imply that use of a modulus (standard stimulus with a predefined annoyance magnitude), in contrast to master scaling, is not sufficient for calibration for individual scaling behavior and context effects.  相似文献   

19.
The effect of tropopause height on the content of 137Cs and total beta activity in surface atmosphere was considered for the period of intensive nuclear weapon tests, from 1968–1971. The activity of 137Cs in monthly air filter samples was measured by gamma spectrometry and total beta activity was determined by 2π proportional counters. The results were correlated with data on tropopause height. The results indicate that the movement of radioactive debris from the stratosphere into the troposphere occurs simultaneously with the changes in tropopause height. The content of long lived radionuclides in the troposphere follows the changes with a certain delay due to meteorological conditions in surface air and due to the location of sampling.  相似文献   

20.
The thermal performances of an evacuated tube collector (ETC) and flat-plate solar air collector (FPC) are experimentally investigated at different air flow rates. To investigate the performance of the ETC and FPC, experimental set-ups were fabricated. Air was used as a working fluid and tested at the same climatic conditions. The ETC had 15 evacuated tubes with a surface area of 1.66 m2. The experimental set-up consisted of a header with a hollow pipe (square pipe) in the centre through which the air flowed. The flat-plate collector had a surface area of 1.35 m2. The FPC had a black painted absorber sheet which divides the collector into two sections. The air flowed through the upper and the lower sections parallel to the collector to minimize the overall heat loss. The temperature of the outlet air depends on several factors along with the airflow rate and the intensity of the solar radiation. It was found that during the day at high flow rates, the efficiency of the ETC varies from 0.12 to 0.5, and for the flat plate it was from 0.29 to 0.68. The maximum temperature of the air was 56.7°C for the ETC and 25.7°C for the FPC.  相似文献   