共查询到20条相似文献,搜索用时 15 毫秒
1.
Mass balance and long-term fate of PCDD/Fs in a lagoon sediment and paddy soil, Niigata, Japan 总被引:1,自引:0,他引:1
Sakai M Seike N Kobayashi J Kajihara H Takahashi Y 《Environmental pollution (Barking, Essex : 1987)》2008,156(3):760-768
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in a sediment core and in samples of surface sediment and paddy soil collected from the Toyano lagoon and Kameda basin in Niigata, Japan, were analyzed to elucidate the temporal trends of their concentrations in the lagoon sediment and the relationship between the sediment and the paddy soil. The mass balance of these pollutants was also estimated to determine their long-term fate in surface waters. An analysis by chemical mass balance identified the agrochemicals pentachlorophenol and 2,4,6-trichlorophenyl 4-nitrophenyl ether as the major sources of PCDD/Fs. On the basis of the findings regarding the mass balance in the Kameda basin over the last 40 years, we estimate that more than half the input of PCDD/Fs to the Kameda basin has disappeared. We suggest that the PCDD/Fs that flowed out from the paddy fields have been transferred to the lower basin. 相似文献
2.
Primitive e-waste dismantling activities have been of increasing concern due to serious environmental and human health problems, and therefore authorities in China have strengthened the regulations on illegal e-waste recycling activities. In this work, we used rice hull as a passive sampler and investigated temporal trends of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) in areas near e-waste recycling sites after the stricter regulations. Furthermore, the distribution patterns and composition profiles of these contaminants were also discussed. The average concentrations of the three groups of persistent organic pollutants (POPs) in rice hulls have markedly decreased during the period of 2005-2009. Specifically, from 12.9 (average value in 2005) to 0.37 pg WHO-TEQ/g (dry weight, dw) (in 2009) for PCDD/Fs, 47.6 (2005) to 7.10 ng g−1 dw (2009) for PCBs, and 2.51 (2005) to 0.89 ng g−1, dw (2009) for PBDEs. The significant decrease of combustion markers 2,3,4,7,8-PeCDF, 1,2,3,6,7,8HxCDF and PCB126, and the PCDD/PCDF ratio from 1:9 (2005) to 7:3 (2009) is likely a result of stricter regulations on open combustion activities. This study suggests that stricter control measures, strengthened laws and regulations and more environmental friendly techniques could be effective measures in reducing the release and formation of related POPs in typical e-waste dismantling sites, and these measures could further improve the quality of the environment and health of the local inhabitants. 相似文献
3.
应用高分辨气相色谱/高分辨质谱(HRGC/HRMS)对珠江三角洲地区土壤中二噁英(PCDD/Fs)的浓度及其分布特征进行了研究。结果表明,土壤样品中PCDD/Fs为118~2 304pg/g,平均值为743pg/g;WHO2005-TEQ为1.09~5.56pg/g,平均值为3.25pg/g。珠江三角洲地区土壤中PCDD/Fs浓度较往年相比稍有下降,且大部分地区土壤中PCDD/Fs污染并不严重。土壤中PCDD/Fs同系物分布以OCDD为主要的特征单体,毒性单体贡献最大的是1,2,3,7,8-PeCDD和2,3,4,7,8-PeCDF,平均占总毒性当量的28.9%和16.3%。对珠江三角洲地区土壤中PCDD/Fs的源分析表明,土壤中PCDD/Fs受污染源影响较小,可能主要来自大气沉降。 相似文献
4.
环境中存在的二噁是一类严重影响食品安全和人类健康的强毒性有机污染物,为了能正确评价这类化合物的来源与环境中分布情况,二噁的分析检测引起了人们强烈的关注。本文介绍了样品检测前处理纯化过程中所用的各种传统的吸附剂(硅酸盐、佛罗里土和活性炭等)和新发展的几种主要吸附剂(2(1芘基)乙基二甲基硅烷化硅胶(PYE)、炭纳米管和多孔石墨炭等)的性能、在样品前处理过程中所起的作用及存在的问题和发展趋势,并在概括样品制备的基础上,阐述了二纯化技术及其检测方法(包括化学分析法和生物分析法)的进展。 相似文献
5.
Seasonal and particle size-dependent variations in gas/particle partitioning of PCDD/Fs 总被引:1,自引:0,他引:1
Lee SJ Ale D Chang YS Oh JE Shin SK 《Environmental pollution (Barking, Essex : 1987)》2008,153(1):215-222
This study monitored particle size-dependent variations in atmospheric polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Two gas/particle partitioning models, the subcooled liquid vapor pressure (P(L)(0)) and the octanol-air partition coefficient (K(OA)) model, were applied to each particle sizes. The regression coefficients of each fraction against the gas/particle partition coefficient (K(P)) were similar for separated particles within the same sample set but differed for particles collected during different periods. Gas/particle partitioning calculated from the integral of fractions was similar to that of size-segregated particles and previously measured bulk values. Despite the different behaviors and production mechanisms of atmospheric particles of different sizes, PCDD/F partitioning of each size range was controlled by meteorological conditions such as atmospheric temperature, O(3) and UV, which reflects no source related with certain particle size ranges but mixed urban sources within this city. Our observations emphasize that when assessing environmental and health effects, the movement of PCDD/Fs in air should be considered in conjunction with particle size in addition to the bulk aerosol. 相似文献
6.
Haitao Shen Cun Yu Ying Ying Yunfeng Zhao Yongning Wu Jianlong Han Qingyuan Xu 《Chemosphere》2009,77(9):1206-1211
A nationwide investigation into polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) in market seafood was conducted for the first time in this study. Total PCDD/F concentrations in fatty fish ranged from 0.13 to 8.64 pg g−1 wet weight (mean 2.05 pg g−1 wet weight), total PCB concentrations ranged from 38.9 to 3514 pg g−1 wet weight (mean 1133 pg g−1 wet weight), and total PBDE concentrations ranged from 42.8 to 913 pg g−1 wet weight (mean 322 pg g−1 wet weight). Corresponding mean toxicity equivalent (TEQ) values for total PCDD/F and dioxin-like PCB were 0.25 pg g−1 wet weight (WHO 98-TEQ) and 0.32 pg g−1 wet weight (WHO 98-TEQ), respectively. OCDD, PCB-138 and PBDE-47 were the dominant compounds according to their respective congeners. WHO 98-TEQ PCDD/PCDF/PCB for fatty fish and shell fish were 0.60 and 0.070 pg g−1 wet weight, respectively, lower than the standard set by the European Commission. The contamination levels and profiles were compared with those documented in previous publications. 相似文献
7.
电子垃圾焚烧排放的二噁英对周围大气环境的影响 总被引:3,自引:0,他引:3
为了研究电子垃圾焚烧产生的二噁英对周围环境的影响,同时在E1和E2采样点分别采集9个大气样品.E1周围分布大量的电子垃圾焚烧点,E2则位于E1南9 km处,周围无其他明显的二噁英排放源.所采样品用同位素稀释法进行分析测定,结果表明,E1和E2大气样品中二噁英的平均质量浓度分别为127.37、22.37 pg/m3,平均毒性当量浓度分别为8.777、1.305 pg I-TEQ/m3.八氯代二苯并呋喃(OCDF)、八氯代二苯并二噁英(OCDD)、七氯代二苯并呋喃(1,2,3,4,6,7,8-HpCDF)和七氯代二苯并二噁英(1,2,3,4,6,7,8-HpCDD)对2,3,7,8位氯代的二噁英的总浓度贡献较大,而五氯代二苯并呋喃(2,3,4,7,8-PeCDF)则对总毒性当量浓度贡献最大,其贡献率超过40%.在E1和E2两个采样点,二噁英在气相中的比例均随着氯原子取代数的增加而降低.两采样点相似的二噁英分布模式和气固分配,说明E2大气中二噁英主要来自于E1电子垃圾焚烧产生的二噁英. 相似文献
8.
Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/N m3 while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/N m3. The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/N m3 and the TEQ concentration was 0.14 ng I-TEQ/N m3. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60–70%) at both EAFs investigated. 相似文献
9.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) were measured in ambient air samples collected from different parts of South Korea in 2008, and the measured levels were used for assessing the spatial and temporal distribution of atmospheric PCDDFs and DL-PCBs in South Korea. The average concentrations of atmospheric PCDD/Fs and DL-PCBs among the 37 sites were 28 fg I-TEQ m−3 (ND ∼ 617) and 1 fg WHO-TEQ m−3 (ND ∼ 0.016). Elevated atmospheric levels of PCDD/Fs and DL-PCBs observed at residential/industrial sites and in the north-west of Korea, indicated a potential contribution and impacts of anthropogenic sources of PCDD/Fs and DL-PCBs. These levels were similar or lower than those previously reported in other ambient air surveys. Average concentrations of PCDD/Fs showed small seasonal variations (ANOVA analysis, p = 0.144). The highest concentrations of PCDD/Fs were observed during winter, followed by spring, autumn and summer. Atmospheric PCDD/Fs and DL-PCBs in South Korea rapidly decreased during the last 10 years (1998-2008), demonstrating the efficiency of stricter regulations and the application of best available technologies/best environmental practices at emission sources. Comparison of the congener profiles and principal component analysis showed that current atmospheric PCDD/Fs are mostly influenced by industrial sources and PCBs from old commercial PCB uses. Nationwide POPs monitoring will continue and allows an effective evaluation of the implementation of the Stockholm Convention on POPs. 相似文献
10.
PCDD/Fs and dioxin-like PCBs in sediment and biota from the Mondego estuary (Portugal) 总被引:1,自引:0,他引:1
The concentrations of 17 polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), and 12 dioxin-like polychlorinated biphenyls (dl-PCBs) were measured in sediment and key species as an initial investigation on PCDD/Fs and dl-PCBs contamination in the Mondego estuary (Portugal). The results demonstrated that the values of the total PCDD/Fs (∑PCDD/Fs) concentrations were considerably lower than those of the sum of dl-PCBs (∑dl-PCBs) in all the studied samples. Regarding the contribution of individual congeners, OCDD was the predominant PCDD/F and the mono-ortho PCB 118 and PCB 105 were the dominant PCBs in the majority of the samples. Our results suggest that PCDD/Fs and PCBs behave quite differently along the aquatic food web: ∑PCDD/Fs concentrations were lower in higher trophic-level organisms with fish presenting a distinct PCDD/Fs congeners profile; on the contrary, the higher ∑dl-PCBs values were found in upper-level biota, although not exclusively, and quite similar dl-PCBs congener profiles were observed in nearly all the studied species. 相似文献
11.
Baseline levels of PCDD/Fs in soil and herbage samples collected in the vicinity of a new hazardous waste incinerator in Catalonia,Spain 总被引:5,自引:0,他引:5
Schuhmacher M Agramunt MC Rodriguez-Larena MC Díaz-ferrero J Domingo JL 《Chemosphere》2002,46(9-10):1343-1350
The construction in Constantí (Catalonia, Spain) of a new hazardous waste incinerator (HWI), which is the first one in Spain, finished in 1999. In order to determine the temporal variation (1996–1998) in the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in the vicinity of the new HWI, 40 soil and 40 herbage samples were collected (1998) at the same sampling points in which samples had been taken two years before (1996). Each sample was analyzed for PCDDs and PCDFs by high resolution gas chromatography/high resolution mass spectrometry. In the 1996 survey, PCDD/F concentrations in soils ranged from 0.13 to 24.20 ng I-TEQ/kg (d.m.), with median and mean values of 0.67 and 1.68 ng I-TEQ/kg (d.m.), respectively. In the present study, PCDD/F concentrations ranged from 0.12 to 17.20 ng I-TEQ/kg (d.m.), with a median value of 0.75 ng I-TEQ/kg (d.m.) and a mean value of 1.59 ng I-TEQ/kg (d.m.). In turn, in the present study PCDD/F concentrations in vegetation ranged from 0.14 to 2.01 ng I-TEQ/kg (d.m.) (median and mean values: 0.23 and 0.31 ng I-TEQ/kg, respectively), while in the 1996 survey PCDD/F concentrations ranged from 0.24 to 1.22 ng I-TEQ/kg (d.m.) (median and mean values: 0.53 and 0.61 ng I-TEQ/kg, respectively). According to the present (1998) and the previous (1996) levels of PCDD/Fs found in soils and vegetation, the area under potential influence of the new facility shows a rather low contamination by these compounds. The current results should be useful to establish the environmental impact of the HWI. 相似文献
12.
Grosso M Biganzoli L Rigamonti L Cernuschi S Giugliano M Poluzzi V Biancolini V 《Chemosphere》2012,86(3):293-299
The behaviour of waste incineration plants with respect to organic toxic trace contaminants such as PCDDs, PCDFs and, to a minor extent, PCBs, is still a matter of concern for the public opinion and the decision makers. It is therefore very important, first, to evaluate the release of these organic toxic trace contaminants in the environment during waste incineration, not only through the stack gas emission but also with the solid and liquid residues, and then to compare the total release with the input through the treated waste in order to assess the plant behaviour as a “sink” rather than a “source” of organic toxic trace contaminants. The experimental investigation carried out on an Italian full scale incineration plant has shown a total 17 PCDD/Fs and 12 dioxin-like PCBs release of 5.5-27 μg WHO-TEQ per tonne of treated waste and an input flux of 1.6-44 μg WHO-TEQ per tonne of waste, with the difference between the input and the output fluxes rather small and the plant behaviour toward organic trace toxic contaminants in average neutral. Results are compared with similar evaluations conducted in the last decade on a number of waste-to-energy (WTE) plants operating in Italy. 相似文献
13.
The presence of polychlorinated dibenzo-p-dioxins and furan (PCDD/Fs) and brominated flame retardants (BFRs) in sludge generated at municipal wastewater treatment plants (MWTPs) and industrial wastewater treatment plants (IWTPs) was investigated. The concentrations of these pollutants were in the following ranges: 5.38-7947 ng kg−1 dw (0.02-49.9 ng WHO-TEQ kg−1 dw) for 17 PCDD/Fs, 17.5-66 761 μg kg−1 dw for 27 polybrominated diphenyl ethers (PBDEs), 1.55-29 604 μg kg−1 dw for hexabromocyclododecanes (HBCDs) (α-, β-, and γ-diastereomers), and 4.01-618 μg kg−1 dw for tetrabromobisphenol A (TBBPA). Generally, the levels of each compound in the sewage-sludge samples were higher than those in the industrial-sludge samples with some exceptions. The characteristic distribution profiles of target compounds were observed for different types of sludge and different sources of wastewater. High-chlorinated PCDD/Fs were dominant in all samples except those from the textile industry. The distribution of the BFRs in industrial-sludge samples varied, whereas that of the BFRs in sewage-sludge samples was consistent. The proportion of penta-BDEs in sewage sludge was higher than that in industrial sludge, even though BDE-209 was the most dominant congener in all the samples. For HBCDs, the distribution of diastereomers (α-, β-, and γ-HBCD) was similar across sludge samples that had the same source of wastewater and treatment processes. 相似文献
14.
Evaluation of atmospheric sources of PCDD/Fs, PCBs and PBDEs around a steel industrial complex in northeast China using passive air samplers 总被引:4,自引:0,他引:4
The concern about emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) from steel industrial parks has increased in the past decades. In this study, polyurethane foam (PUF)-disk based passive air samples were collected in and around a big steel industrial park of Anshan, Northeast China from June 2008 to March 2009. The levels, seasonal variations and potential sources of PCDD/Fs, PCBs and PBDEs in the atmosphere around the steel industrial complex were investigated, and potential contribution of these three groups of persistent organic pollutants (POPs) from iron and steel production was also assessed. The air concentrations of ∑17PCDD/Fs (summer: 0.02-2.77 pg m−3; winter: 0.20-9.79 pg m−3), ∑19PCBs (summer: 23.5-155.8 pg m−3; winter: 14.6-81.3 pg m−3) and ∑13PBDEs (summer: 2.91-10.7 pg m−3; winter: 1.10-3.89 pg m−3) in this targeted industrial park were relatively low in comparison to other studies, which implied that the industrial activities of iron and steel had not resulted in serious contamination to the ambient air in this area. On the whole, the air concentrations of PCDD/Fs in winter were higher than those of summer, whereas the concentrations of PCBs and PBDEs showed opposite trends. The result from principal component analysis indicated that coal combustion might be the main contributor of PCDD/F sources in this area. 相似文献
15.
Estimation and characterization of PCDD/Fs and dioxin-like PCBs from Chinese iron foundries 总被引:5,自引:0,他引:5
The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper.In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupolas. When iron ore lump and sinter were used as raw material, the emission factors were about 250 ng TEQ t−1 of product. However, if the raw material was scrap, the emission factors varied owing to the different contents of organic materials in the raw materials. It was found that the mean WHO-TEQ values of PCDD/Fs and DL-PCBs were 144 and 34.2 pg Nm−3 in stack gas and 20.0 and 1.58 pg g−1 in fly ash. In multiple tests, it was estimated that the mean emission factors of PCDD/Fs and DL-PCBs were 365 and 10.9 ng WHO-TEQ t−1 released to residue and 2719 and 555 ng TEQ t−1 released to air. The total emission amounts of PCDD/Fs and DL-PCBs from Chinese iron foundries with cupola furnaces released to residue and air were 16.8 and 146 g WHO-TEQ in 2008, respectively. 相似文献
16.
A design of two simple models to predict PCDD/F concentrations in vegetation and soils 总被引:4,自引:0,他引:4
The vegetation and soil levels of the 17 polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/F) toxic congeners were calculated by means of a vegetation and a soil model, respectively. Both models predicted the levels of the 17 PCDD/F congeners in quite good agreement with the observed results although the soil model was more accurate than the vegetation model. Four different pathways of contribution to the vegetation concentrations were taken into account: vapour-phase absorption, dry particle deposition, wet particle deposition and uptake by root. The most important pathway was the vapour-phase absorption and the less was the uptake by root. In the soils model four pathways were considered: background soil concentration, dry particle deposition, wet particle deposition and uptake by root. After the background concentration, the most important pathway was the wet deposition. 相似文献
17.
选取广州某地大气环境作为研究对象,采用高分辨气质联用色谱对气相、颗粒相中17种二噁英(PCDD/Fs)单体进行分析。结果表明,研究区域大气PCDD/Fs主要集中于颗粒相,且气相和颗粒相中PCDD/Fs均表现出"源"特征。颗粒相中PCDD/Fs单体以OCDD、1,2,3,4,6,7,8-HpCDF、OCDF、1,2,3,4,6,7,8-HpCDD为主;气相中PCDD/Fs单体以1,2,3,7,8-PeCDF、2,3,4,7,8-PeCDF、1,2,3,4,7,8-HxCDF、1,2,3,4,6,7,8-HpCDF为主。颗粒相中PCDD/Fs浓度随着氯原子数的增加而增加,气相中PCDD/Fs随着氯原子数的增加而减少。气相中主要毒性贡献单体为2,3,4,7,8-PeCDF,其与气相总毒性当量浓度的相关系数为0.908;颗粒相中主要毒性贡献单体为2,3,4,7,8-PeCDF、2,3,4,6,7,8-HxCDF,与颗粒相总毒性当量浓度的相关系数分别为0.851、0.883。主成分分析结果表明,颗粒相和气相的毒性当量浓度具有相似的分布特征。 相似文献
18.
A novel cost-effective thermal treatment technology has been proposed for the removal of PCDD/Fs from contaminated sediment and released effluent gas using charcoal as both an adsorbent and a thermal source. When a reactor was used for thermal treatment, the PCDD/Fs removal efficiency exceeded 98% from the sediment at the three different air superficial velocities employed in this study. The total PCDD/F international toxic equivalent (I-TEQ) contents, both in the treated sediments and effluent gas, were below the Japanese emission standard limit. Analysis of the PCDD/F contents in different fractions showed that large quantities of PCDDs but not PCDFs were evaporated from the sediment and adsorbed in the moist sediment column. This difference was attributed to the formation of PCDDs from pentachlorophenol (PCP) during the cooling process following the thermal treatment process in the reactor. This proposed thermal process provides a promising alternative to the conventional methods. 相似文献
19.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are ubiquitous contaminants, mainly released into the environment during combustion processes (point sources), but also from other sources (traffic, uncontrolled combustion).This study aims at investigating the contribution of a steel plant in NW Italy (700 000 tons of steel year−1) to the air concentrations of PCDDs/PCDFs at local level, through the analysis of measured, modelled and literature data. The study was carried out in an area of 600 km2, using air quality data measured by the institutional monitoring network, data obtained from AERMOD simulations and literature data.The measured air concentrations were consistent with literature values for similar areas, and both the homologue profiles and PCA analyses showed a clear distinction between the monitoring stations and the source profiles.All the previous results were confirmed by the air dispersion model (AERMOD), that predicted PCDD/F air concentrations due to the steel plant from four to two orders of magnitude lower than those measured in the monitoring stations, highlighting the presence of other sources.This study outlines the limited influence of the source in the local PCDD/F air concentrations and at the same time the usefulness of a joint analysis of measured, literature and calculated data to correctly evaluate the role of a source to the local pollution. The study also highlights the usefulness of AERMOD as a complementary tool to define the correct placement of monitoring stations and to locate those areas expected to have the highest air concentrations deriving from a source. 相似文献
20.
Baseline soil levels of PCDD/Fs established prior to the construction of municipal solid waste incinerators in China 总被引:1,自引:0,他引:1
In order to determine the baseline contamination by polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in different areas in China, prior to the construction of municipal solid waste incinerators (MSWIs), a total of 32 representative soil samples was collected near 16 incinerators and analyzed for their PCDD/F concentrations. The PCDD/F baseline concentrations in the soil samples ranged from 0.32 to 11.4 ng I-TEQ kg−1 (dry matter), with average and median value of 2.73 and 2.24 ng I-TEQ kg−1 (dry matter), respectively, and a span between maximum and minimum recorded value of 36. The PCDD homologues predominated in 26 out of 32 soil samples, with the ratio (PCDDs)/(PCDFs) ranging from 1.1 to 164; however in the other 6 samples, PCDF homologues were larger, with the same ratio varying from 0.04 to 0.8. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) were used to examine PCDD/F amount and profile in these soil samples, and their possible associations with known emission sources: in this process 6 really distinct isomer fingerprints were identified. Background PCDD/F levels and profiles were comparable to those found in soils from China and other countries and indicate a rather low baseline PCDD/F contamination of soils. The present data provide the tools for future assessment of a possible impact of these MSWIs. 相似文献