首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 296 毫秒
1.
针对造纸废水好氧处理中钙离子(Ca2+)浓度过高影响生化过程和后续膜处理的问题,在实验室模拟废水曝气,研究Ca2+存在对COD去除效果的影响;对厌氧出水进行曝气实验,探究曝气量对钙去除效果的影响;分析表征造纸废水液相中Ca2+浓度和固相污泥中钙的形态,探究造纸废水曝气池中钙的迁移转化规律.结果发现:Ca2+的存在会影响活性污泥的活性,进而导致曝气过程中COD的去除率从71.76%降至36.94%;厌氧出水曝气初始阶段内曝气量越大,Ca2+的去除率越高;Ca2+浓度从厌氧出水到二沉池出水过程中逐渐下降,从游离态转变为CaCO3的结合态而除去.  相似文献   

2.
林可霉素生产废水的厌氧生物处理工艺   总被引:17,自引:2,他引:15  
采用单相中温升流式厌氧污泥床(UASB)反应器厌氧生物工艺处理含有有毒难降解有机物的林可霉素生产废水.当进水COD 8000~14000 mg/L,HRT约10h时,COD容积负荷可达20~35kg/(m3·d),COD去除率为50%~55%.适时调整并维持较高的表面水力负荷[0.2~0.4 m3/(m2·h)]、较高的进水有机基质浓度(COD为2000~3000mg/L)和污泥COD负荷[0.2~0.5 kg/(kg·d)],并适当延长启动驯化时间可培养出沉降性好、污泥活性较高的颗粒污泥.废水厌氧生物降解动力学符合Monod方程,动力学常数Vmax=1.3 d-1,Ks=8133mg/L.废水中不可生物降解物质占总COD的比例约为30%,这是废水COD去除率偏低的重要因素.  相似文献   

3.
短程硝化反硝化除磷颗粒污泥的同步驯化   总被引:1,自引:0,他引:1  
王文琪  李冬  高鑫  刘博  张杰 《环境科学》2021,42(6):2946-2956
本实验对3组同规格SBR反应器分别采用分阶段法(A/O-A/O/A)异步驯化、连续曝气A/OA同步驯化和间歇曝气A/O/A同步驯化的方式运行.以人工配水为进水基质,接种絮状污泥,通过水力选择压颗粒化,探讨了不同运行方式下短程硝化反硝化颗粒污泥的驯化及脱氮除磷特性.结果表明,在较短曝气时长(140 min)联合较低曝气强度[3.5 L·(h·L)-1]下,间歇曝气A/O/A同步驯化最具优势,后期稳定运行期间碳、氮、磷的平均去除率分别为90.74%、91.15%和95.66%,可实现同步去除.粒径为895μm,颗粒虽小但均匀致密,f值(MLVSS/MLSS)平稳保持在0.8~0.85,有较高的生物量,这是由于间歇曝气下好/缺氧的交替运行,使得缺氧异养菌作为颗粒的核心,有利于颗粒污泥结构的稳定.批次实验结果表明,间歇曝气A/O/A同步驯化下比氨氧化速率为3.38 mg·(g·h)-1,能利用NO2-为电子受体的反硝化聚磷菌(DPAOs)占比达65.46%,更有利于氨氧化菌(AOB)和NO2-型DPAOs的同步驯化及富集,保证稳定的处理效果.  相似文献   

4.
以SBR系统反硝化除磷污泥为对象,利用氧化还原电位、溶解氧和磷酸盐微电极定量研究了污泥聚集体内除磷菌的原位除磷活性及有机物浓度的影响.结果发现,厌氧初期污泥聚集体内最大净体积释磷速率为3.29mg·(cm3·h)-1,是缺氧初期最大净体积吸磷速率的3倍左右;厌氧末期释磷速率明显降低,最大净体积释磷速率仅为厌氧初期的一半.在缺氧末期,最大净体积吸磷速率降至0.14mg·(cm3·h)-1,且在1800 μm以下深层区域发生了"二次释磷"现象.随着COD浓度由350 mg·L-1降至250 mg·L-1和150 mg·L-1,反硝化除磷菌的最大净体积释磷速率由3.27 mg·(cm3·h)-1降至2.44 mg·(cm3·h)-1和2.01 mg·(cm3·h)-1,且快速吸磷区域整体向污泥聚集体表层收窄.  相似文献   

5.
全程自养颗粒污泥快速启动及混合营养型脱氮性能分析   总被引:2,自引:2,他引:0  
在连续流条件下,基于颗粒污泥全程自养脱氮(CANON)工艺的快速启动和混合营养条件下高效脱氮,是CANON工程应用的重要环节.本研究在气提内循环反应器(AIR)中,以老化的CANON颗粒污泥经机械破碎至0.3 mm作为种泥,实现混合营养型单级颗粒污泥同步脱氮除碳.启动26 d,通过控制DO,系统出现稳定的部分硝化,再缩短HRT提升氨氮负荷至5.65 kg ·(m3 ·d)-1,促进颗粒化和厌氧氨氧化;第68 d,总氮去除率达到58%之后,进水加入有机物,C/N从0提升到0.25和0.5,促进AOB、AMX和异养微生物的协同,氨氮去除率达95%,总氮去除率达85%,COD去除率达80%左右.COD浓度增加,能较好地抑制Nitrospira菌属等NOB的活性,q(NH4+-N)和q(TN)稳定在0.4 g ·(g ·h)-1和0.34 g ·(g ·h)-1,q(NO3--N)约为0.02 g ·(g ·h)-1.采用MiSeq高通量测序对微生物多样性分析,表明有机物对污泥中NitrosomomasCandidutus_Kuenenia丰度未产生显著影响,增加了Candidutus_Brocadia菌属以及具有反硝化功能Denitratisoma等菌属的丰度.这对于快速启动连续流CANON颗粒污泥工艺处理低C/N比废水提供思路.  相似文献   

6.
针对高浓度氯霉素(CAP)废水在实际厌氧生物处理过程中难降解、毒性大及对活性污泥产生的抑制问题,本文采用三维石墨烯气凝胶(GA)作为外源强化介质,通过批次试验探究了不同初始石墨烯气凝胶浓度、电子供体(蔗糖)浓度以及氯霉素浓度对氯霉素废水厌氧降解过程中氯霉素去除速率、有机物去除率以及甲烷产量等影响.结果表明:当初始石墨烯气凝胶浓度为0.5 g·L-1、初始电子供体浓度为8.8 mmol·L-1、初始氯霉素浓度为50 mg·L-1时,强化效果最为显著,当反应进行到18 h时,强化系统中氯霉素的去除率达到94%以上,COD的去除率稳定在26.6%~35.6%之间,强化系统比只加入污泥的生物系统氯霉素去除速率增加了48%~51.6%,COD去除率增加了10%左右.石墨烯气凝胶作为电子转移中间介体和微生物富集的载体,促进微生物种间进行直接电子转移,加速氯霉素的脱氯过程和甲烷的产生,为高浓度抗生素废水的厌氧生物处理提供了新的处理思路和参考.  相似文献   

7.
采用臭氧催化氧化-曝气生物滤池(BAF)组合工艺对抗生素废水二级生化处理出水进行深度处理,考察了组合工艺对废水污染物的去除效果,通过三维荧光光谱结合平行因子法(EEMs-PARAFAC)分析了废水中有机物的荧光变化特征,并利用Illumina MiSeq高通量测序技术对BAF中微生物菌群结构的变化进行研究.结果表明,在最佳运行条件下,抗生素废水COD平均值由232 mg·L-1降至46 mg·L-1,NH4+-N平均浓度由12 mg·L-1降至4.1 mg·L-1,出水水质可稳定达到《发酵类制药工业水污染物排放标准》(GB21903-2008).EEMs-PARAFAC从废水中解析出3类荧光组分,主要可归为腐殖酸(胡敏酸)、富里酸及其混合物,经组合工艺处理后荧光强度大幅下降甚至消失.Illumina MiSeq测序显示,污泥经抗生素废水驯化后微生物丰富度和均匀度明显降低,Proteobacteria(变形杆菌门)、Chloroflexi(绿屈挠菌门)和Firmicutes(厚壁菌门)是优势菌门,其中,Thiothrix(发硫菌属)、ThermomonasPseudoxanthomonas(假黄单胞菌属)和JG30_KF_CM45是降解抗生素类污染物的主要菌属.  相似文献   

8.
采用SBR反应器,在交替缺氧/好氧模式下处理低C/N生活污水,考察曝气量、盐度对短程硝化好氧颗粒污泥脱氮速率及粒径分布的影响.结果表明,在25 ℃、pH为7.5~8.0条件下,当进水NH4+-N为65 mg·L-1时,控制曝气量分别为8.75、12.50和16.25 L·h-1·L-1,在第35、24和23个周期时NH4+-N去除率分别高达95.49%、98.46%和98.54%,选取12.50 L·h-1·L-1为最佳曝气量.控制在最佳曝气量条件下,当盐度为0时,NH4+-N去除率及亚硝积累率分别为98.46%和90.42%;在盐度为5.0%时,NH4+-N去除率和亚硝积累率分别为98.34%和96.71%.当曝气量从8.75 L·h-1·L-1提升为16.25 L·h-1·L-1,颗粒污泥平均粒径由170 μm增大为231.5 μm;控制曝气量在12.5 L·h-1·L-1,增加盐度至5.0%,颗粒污泥平均粒径由231 μm下降至156 μm,其占比由40.50%增加到48.26%.  相似文献   

9.
为考察有机物对厌氧氨氧化生物膜反应器脱氮效能的影响,采用MPN(most probable number)法和高通量测序技术,结合处理效果数据,对比分析了有无有机物影响下生物膜中微生物群落差异.试验表明:在进水有机物(COD)为30和60 mg·L-1作用下,总氮去除率与进水COD为0 mg·L-1时的84.10%相比较分别提高了5.08%和10.41%;COD为90 mg·L-1时,总氮去除率降至89.05%.由MPN法和高通量测序结果可知,相对于无有机物,60 mg·L-1有机物使反应器中反硝化菌数量增加,浮霉菌门和变形菌门丰度明显提高,且微生物群落更加丰富.有机物能影响反应器中厌氧氨氧化、反硝化脱氮效能及微生物菌落丰度,适宜的有机物浓度可使厌氧氨氧化与反硝化作用有效耦合,提高反应器的脱氮效能.本研究可为厌氧氨氧化生物膜反应器处理含有机物的实际污水提供参考价值.  相似文献   

10.
乙酸钠为碳源时进水COD和总磷对生物除磷的影响   总被引:11,自引:4,他引:7  
阮文权  邹华  陈坚 《环境科学》2002,23(3):49-52
研究了乙酸钠为碳源时,乙酸盐和总磷浓度对循序间歇式生物除磷工艺运行效果的影响,以及含高浓度乙酸盐废水不能有效除磷的原因结果表明:COD<600mg·L-1时,随着COD/TP值的增大,总磷去除率提高,COD/TP<50时,磷的去除率提高显著,但当COD/TP>50时,磷的去除变化不大;进水乙酸盐浓度过高(COD>600mg·L-1)使除磷效率逐渐下降,COD>1000 mg·L-1会使生物除磷系统完全崩溃;研究发现除磷效率的下降是由于过多的乙酸盐从厌氧段进入了好氧段,引起丝状菌的增殖、污泥膨胀,导致聚磷菌被洗出.  相似文献   

11.
不同底物条件下UASB反应器中碳酸钙的沉淀   总被引:3,自引:0,他引:3  
以UASB反应器处理含钙的乙酸废水和葡萄糖、可溶性淀粉混合废水,在Ca2+浓度800 mg·L-1,COD容积负荷9 kg·(m3·d)-1条件下,研究了碳酸钙在反应器中的沉淀规律及其差异.结果表明,碳酸钙在发生大量沉淀前都要经历30 d左右的诱导期,此后反应器中碳酸钙的沉淀率因进水底物不同而出现显著差异.以乙酸为底物时,碳酸钙在污泥中的最大沉淀率可达到65%,然后稳定到25%;而在以葡萄糖和可溶性淀粉为底物的废水中,钙的沉淀率一直维持在7.5%左右.对于这2种废水,钙的沉淀在180 d内可以使污泥的灰分从大约10%分别升高到70%以上和30%左右.但是高的生物污泥灰分含量并没有明显影响废水处理的效果,两反应器的COD去除率始终维持在90%左右.扫描电镜分析发现两反应器内颗粒污泥微观结构存在较大差异,这可能是导致其中碳酸钙沉淀过程和沉淀量存在较大差异的原因.  相似文献   

12.
超低溶解氧条件下的EBPR系统除磷性能   总被引:1,自引:1,他引:0  
实验采用两个交替厌氧/好氧(An/O)模式运行的SBR反应器,对不同溶解氧(DO)浓度梯度下EBPR系统除磷效果及工艺性能进行了为期127 d的研究.在未控制DO的对照组反应器R1中,好氧段DO≥6 mg·L~(-1),运行的前65 d内工艺除磷性能稳定,除磷率95.9%,出水总磷0.5 mg·L~(-1),但由于系统长期处于过曝气状态,65 d后除磷性能逐渐恶化,直至97 d后系统彻底失效,整个运行阶段(1~127 d)出水总磷一级A达标率为39.4%.对于实验组反应器R2,控制好氧段DO浓度分别为2、1、0.5、0.2、0.1 mg·L~(-1),各工况初期除磷性能均有小幅波动,但除磷率迅速回升,继而反应器达到稳定运行.统计发现,实验组反应器R2在整个运行阶段出水总磷一级A的达标率为94.6%,127 d内仅有6 d不达标,工艺性能远优于R1.DO=2 mg·L~(-1)系统的比吸磷速率接近最大值,而低DO条件对比吸磷速率影响较大.实验还发现,尽管由超低DO(0.1 mg·L~(-1))引起的有机物降解速率低导致系统发生污泥微膨胀,但出水总磷仍能100%达标排放,微好氧EBPR的节能除磷具有可行性.  相似文献   

13.
Among the numerous parameters affecting the membrane bioreactor (MBR) performance, the aeration intensity is one of the most important factors. In the present investigation, an anoxic/aerobic-type (A/O-type) sequencing batch MBR system, added anoxic process as a pretreatment to improve the biodegradability of azo dye wastewater, was investigated under different aeration intensities and the impact of the aeration intensity on effluent quantity, sludge properties, extracellular polymeric substances (EPS) amount generated as well as the change of permeation flux were examined. Neither lower nor higher aeration intensities could improve A/O-type sequencing batch MBR performances. The results showed 0.15 m3·h−1 aeration intensity was promising for treatment of azo dye wastewater under the conditions examined. Under this aeration intensity, chemical oxygen demand (COD), ammonium nitrogen and color removal as well as membrane flux amounted to 97.8%, 96.5%, 98.7% and 6.21 L·m−2·h−1, respectively. The effluent quality, with 25.0 mg·L−1COD, 0.84 mg·L−1 ammonium nitrogen and 8 chroma, could directly meet the reuse standard in China. In the meantime, the sludge relative hydrophobicity, the bound EPS, soluble EPS and EPS amounts contained in the membrane fouling layer were 70.3%, 52.0 mg·g−1VSS, 38.8 mg·g−1VSS and 90.8 mg·g−1VSS, respectively, which showed close relationships to both pollutant removals and membrane flux.  相似文献   

14.
To improve the efficiency of nitrogen removal with lower energy consumption, the study of feedforward control was carried out on a pilot-scale anaerobic-anoxicoxic (AAO) plant for the treatment of municipal wastewater. The effluent qualities of the pilot plant under different control strategies were investigated. The results indicated that the change of external recycle was not a suitable approach to regulate the sludge concentration of plug-flow reactors; adjusting the aeration valve and dissolved oxygen set-point according to ammonia load could overcome the impact of influent fluctuation; and the denitrification potential could be estimated based on the transit time of anoxic zone and the relative content of carbon resource entering the anoxic zone. Simple feedforward control strategies for aeration and internal recycle were subsequently proposed and validated. The nitrogen removal was successfully improved in the pilot plant. The effluent total nitrogen had decreased by 29.9% and was steadily controlled below 15 mg·L−1. Furthermore, approximately 38% of the energy for aeration had been saved.  相似文献   

15.
好氧颗粒污泥处理制糖工业废水厌氧出水的除磷特性研究   总被引:2,自引:1,他引:1  
制糖工业废水经厌氧生物处理后,COD大幅下降,但是出水中N、P含量仍然较高,严重破坏水体生态平衡.利用好氧颗粒污泥对制糖工业废水的厌氧出水进行脱氮除磷处理,讨论了其除磷过程.经复合底物(乙酸盐、丙酸盐、丁酸盐)培养的好氧颗粒污泥直径1.7 mm,SVI为38.43 mL.g-1,TP去除率达90.9%,出水磷含量仅为1.3 mg.L-1,单位COD释磷率为0.571,厌氧条件下磷的释放速率达到5.73 mg.(g.h)-1,好氧颗粒污泥表现出较好的沉淀性能和较高的除磷活性.由于底物中丙酸盐、丁酸盐含量增加,使得聚磷菌在反硝化过程中NO3--N的利用率增加,即消耗单位质量的NO3--N可以吸收更多的磷.好氧颗粒污泥及其胞外聚合物中P元素的含量与其中Mg、Ca、Fe元素的含量表现出很高的相关性,胞外聚合物对P的吸附使得体系除磷能力进一步增强.通过对污泥反硝化除磷的研究发现,反硝化聚磷菌占总聚磷菌的61.9%,其吸磷量与消耗硝酸盐的比值[m(P)/m(NO3--N)]为1.14.  相似文献   

16.
为了解同步短程硝化内源反硝化除磷(SPNDPR)系统的脱氮除磷特性,以低C/N城市污水为处理对象,采用延时厌氧(180 min)/好氧运行的SBR反应器,通过联合调控曝气量和好氧时间,考察了该系统启动与优化运行特性.结果表明,当系统好氧段曝气量为0. 8 L·min~(-1),好氧时间为150 min时,出水PO_4~(3-)-P浓度约为1. 5 mg·L~(-1)左右,出水NH_4~+-N和NO_3~--N浓度由10. 28 mg·L~(-1)和8. 14 mg·L~(-1)逐渐降低至0 mg·L~(-1)和2. 27 mg·L~(-1),出水NO_2~--N浓度逐渐升高至1. 81 mg·L~(-1);当曝气量提高至1. 0 L·min~(-1)且好氧时间缩短至120min后,系统除磷、短程硝化性能逐渐增强,但总氮(TN)去除性能先降低后逐渐升高,最终出水PO_4~(3-)-P、NH_4~+-N分别稳定低于0. 5 mg·L~(-1)和1. 0 mg·L~(-1),好氧段亚硝积累率和SND率分别达98. 65%和44. 20%,TN去除率达79. 78%. SPNDPR系统内好氧段好氧吸磷、反硝化除磷、短程硝化、内源反硝化同时进行保证了低C/N污水的同步脱氮除磷.  相似文献   

17.
曝停时间比对间歇曝气SBR短程硝化的影响   总被引:9,自引:0,他引:9       下载免费PDF全文
常温条件下(20~25℃),以生活污水为研究对象,采用间歇曝气序批式反应器1#、2#、3#,研究了不同曝停时间比(3:1、3:2、3:3)对亚硝酸盐氮积累、亚硝化稳定性、污染物去除效果及污泥沉降性能的影响.结果表明,在一定范围内,单元停曝时间所占比例越大,即曝停时间比越小越有利于亚硝酸盐氮的积累,启动速度越快,三者分别经35,30,29d实现了亚硝化的启动;稳定运行阶段,三者的氨氮容积去除负荷分别为0.57,0.48,0.40d-1,曝停时间比越小,则氨氮去除负荷越小,COD去除效果没有明显区别;1#运行至第82d时,亚硝化率呈现逐渐下降的趋势,2#、3#仍能稳定运行,因此曝停时间比越小,越有利于抑制NOB的增殖,维持亚硝化的稳定,且污泥沉降性能越好,越有利于抑制丝状菌污泥膨胀.  相似文献   

18.
Two identical full-scale biogas-lift reactors treating brewery wastewater were inoculated with different types of sludge to compare their operational conditions, sludge characteristics, and kinetic models at a mesophilic temperature. One reactor (R1) started up with anaerobic granular sludge in 12 weeks and obtained a continuously average organic loading rate (OLR) of 7.4 kg chemical oxygen demand (COD)/(m3.day), COD removal efficiency of 80%, and effluent COD of 450 mg/L. The other reactor (R2) started up with residual activated sludge in 30 weeks and granulation accomplished when the reactor reached an average OLR of 8.3 kg COD/(m^3·day), COD removal efficiency of 90%, and effluent COD of 240 mg/L. Differences in sludge characteristics,biogas compositions, and biogas- lift processes may be accounted for the superior efficiency of the treatment performance of R2 over R1. Grau second-order and modified StoverKincannon models based on influent and effluent concentrations as well as hydraulic retention time were successfully used to develop kinetic parameters of the experimental data with high correlation coefficients (R2 〉 0.95), which further showed that R2 had higher treatment performance than R1. These results demonstrated that residual activated sludge could be used effectively instead of anaerobic granular sludge despite the need for a longer time.  相似文献   

19.
生活污水预沉淀-SNAD颗粒污泥工艺小试   总被引:1,自引:1,他引:0  
李冬  崔雅倩  赵世勋  刘志诚  张杰 《环境科学》2019,40(4):1871-1877
采用人工配水,在SBR反应器中启动同步短程硝化、厌氧氨氧化耦合反硝化(SNAD)颗粒污泥工艺,随后逐渐降低进水氨氮浓度,低氨氮稳定运行一段时间后通入预沉淀后生活污水,考察SNAD颗粒污泥工艺处理生活污水的脱氮性能及稳定性.结果表明,SNAD工艺启动成功后,氨氮去除率大于98%,总氮去除率在89%左右,随着进水氨氮浓度逐渐降低,亚硝酸盐氧化菌(NOB)活性升高,总氮去除率逐渐下降至75%左右.通入预沉淀生活污水(NH4+-N 52~63 mg·L-1,COD 99~123 mg·L-1)后,平均总氮去除率为73.2%,出水COD浓度在35 mg·L-1以下,最大出水氨氮和总氮浓度为0.7 mg·L-1和12.8 mg·L-1,连续30d以上出水氨氮和总氮浓度达到《城镇污水处理厂污染物排放标准》一级A排放标准,实现了生活污水碳氮同步高效去除的目的.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号