1.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

2.
A procedure for the determination of atmospheric acrylic acid in air at the microgram m-3 to mg m-3 level is described. Diffusion-based sampling, designed to discriminate gaseous analytes from their particulate counterparts, has been used. Acrylic acid is collected with an efficiency of > 98% in tubular denuders coated with sodium hydroxide-barium hydroxide-hydroquinone monomethyl ether, and analyzed by high performance liquid chromatography with UV absorbance detection. The detection limit is 2.9 micrograms m-3 at a flow rate of 0.5 L min-1 and 30 min sampling time. A precision (p = 0.95, n = 10) of 7.5% of the overall procedure was achieved at the 100 micrograms m-3 level. Results of laboratory studies concerning the effect of the coating reagent and the relative humidity on the sampling efficiency as well as possible interferences, in particular by ozone, and the elimination of these interferences are discussed. This method was developed to monitor workplace atmospheres as well as ambient air in industrial environments.  相似文献   

3.
A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.  相似文献   

4.
A denuder/filter system constructed for solvent-free personal exposure measurements was evaluated for separation of vapour and particulate 4,4'-methylenediphenyl diisocyanate (4,4'-MDI) generated from heated PUR-foam. The two different phases were collected in the denuder and on the filter, respectively, by chemosorption on a polydimethylsiloxane (SE-30)-dibutylamine (DBA) stationary phase. Both repeatability and the total mass concentration of 4,4'-MDI were similar to that obtained from the reference method, in this case an impinger/filter system. The penetration of particles through the denuder at 300 ml min(-1) was nearly 100% in the particle size range 25 to 700 nm, which fits well with the Gormley-Kennedy equation. Denuder/filter sampling of the 4,4'-MDI aerosol at 500 ml min(-1) yielded a phase distribution that was in accordance with the results from the reference method. The method limit of detection was 6 ng m(-3) and 4 ng m(-3) for the denuder and filter, respectively, when using an air sampling flow rate of 300 ml min(-1) and a sampling period of 15 min. This is well below the Swedish occupational exposure limit (OEL) of 50 and 100 microg m(-3) for an 8-hour working day and a 5-min period, respectively.  相似文献   

5.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

6.
The applicability of a low resolution (8 cm-1) Fourier transform infrared (FTIR) gas analyser with an absorption path length of 3 m was evaluated for the on-line monitoring of organic solvent mixture emissions in a flexographic ink manufacturing plant. The on-line monitoring revealed that the highest variations of solvent concentrations, up to three decades, occurred in the exhaust air. The FTIR analyser with a dynamic range of four decades covers well the concentration ranges typically found in the exhaust air and in the workroom air of ink manufacturing plants. The average emission rate of solvent mixture based on a sampling period of two days was 1.8 kg h-1 consisting of mainly ethanol (70%), ethyl acetate (15%) and propan-2-ol (11%). The detection limits of the analyser for the solvent compounds ranged from 0.3 to 4.3 mg m-3 and the measurement uncertainty was less than 10% in the concentration range of 8-15,000 mg m-3. These characteristics make the apparatus appropriate for most industrial hygiene applications. An FTIR spectrophotometer, equipped with an multipoint sampling unit, facilitates rapid identification of solvent components, real-time display of concentration data relevant to workroom air and environment monitoring as well as process control. Furthermore, the on-line concentration information enabled a rapid selection of representative sampling locations. The spectrophotometer is transportable, rugged and relatively simple to calibrate even in a hostile industrial environment.  相似文献   

7.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

8.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

9.
A simple and sensitive method to determine parts per billion (ppb) of atmospheric formaldehyde in situ, using chromotropic acid, is described. A colorimetric sensor, coupled to a droplet of 15.5 microL chromotropic acid, was constructed and used to sample and quantify formaldehyde. The sensor was set up with two optical fibers, a light emitting diode (LED) and two photodiodes. The reference and transmitted light were measured by a photodetection arrangement that converts the signals into units of absorbance. Air was sampled around the chromotropic acid droplet. A purple product was formed and measured after the sampling terminated (typically 7 min). The response is proportional to the sampling period, analyte concentration and sample flow rate. The detection limit is approximately 2 ppb and can be improved by using longer sampling times and/or a sampling flow rate higher than that used in this work, 200 mL min-1. The present technique affords a simple, inexpensive near real-time measurement with very little reagent consumption. The method is selective and highly sensitive. This sensor could be used either for outdoor or indoor atmospheres.  相似文献   

10.
An automatic monitor has been developed for measuring formaldehyde in air using a sensitive tape for formaldehyde. It is based on the color change of the tape on reaction with formaldehyde. The porous cellulose tape, containing silica gel as an absorbent and impregnated with the processing solution containing hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4.0, red-yellow), glycerin and methanol, was found to be a highly sensitive means of detecting formaldehyde and maintains a stable sensitivity. When the tape was exposed to a sample of air containing formaldehyde, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate, and it could be recorded by measuring the intensity of reflected light (555 nm). The tape could be used to detect down to 0.08 ppm (World Health Organization standard) of formaldehyde with a sampling time of 30 min and a flow rate of 100 mL min-1. Reproducibility tests showed that the relative standard deviation of response (n = 10) was 3.8% for 0.1 ppm formaldehyde. The monitor is simple, specific, capable of unattended operation and is recommended for both laboratory and field operation.  相似文献   

11.
The dialdehyde glyoxal (ethanedial) is an increasingly used industrial chemical with potential occupational health risks. This study describes the development of a personal sampling methodology for the determination of glyoxal in workroom air. Among the compounds evaluated as derivatizing agents; N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH), 1,2-phenylenediamine (OPDA), 1-dimethylaminonaphthalene-5-sulfonylhydrazine (dansylhydrazine, DNSH) and 2,4-dinitrophenylhydrazine (DNPH), DNPH was the only reagent that was suitable. Several different samplers were evaluated for sampling efficiency of glyoxal in workroom air using DNPH as derivatizing agent; in-house DNPH coated silica particles packed in two different types of glass tubes, impingers containing acidified DNPH solution, filter cassettes containing glass fibre filters coated with DNPH, a commercially available solid phase cartridge sampler originally developed for formaldehyde sampling (Waters Sep-Pak DNPH-silica cartridge), and the commercially available SKC UMEx 100 passive sampler originally developed for formaldehyde sampling. Aldehyde atmospheres for sampler evaluation were generated with an in-house made vapour atmosphere generator coupled to a sampling unit, with the possibility of parallel sampling. The resulting glyoxal-DNPH derivative was determined using both LC-UV and LC-APCI-MS with negative ionization. By far, the highest recovery of glyoxal was obtained employing one of the in-house DNPH coated silica samplers (93%, RSD = 3.6%, n = 12).  相似文献   

12.
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.  相似文献   

13.
A simple assay for some proteolytic enzymes has been developed which can be performed directly on the surface of a cellulose nitrate filter used to capture the analyte during workplace monitoring for health and safety purposes. Following air sampling the analysis is performed on the filter which is retained within the air sampler. This involves two steps: first, a 15 min incubation in which the captured enzyme is dissolved and then digests an alkaline-phosphatase-labelled antibody immobilised as a small dot on the surface of the filter; and second, is a 10 min incubation with substrate solution, which follows an in situ wash under a vacuum. During the incubation colour develops on the spot at the location of the immobilised enzyme antibody conjugate. The intensity of the spot can be assessed visually within the sampler to ascertain the presence or absence of captured enzyme, or alternatively quantitative results can be obtained using an optical scanner. The limit of detection is 5 ng per filter for subtilisin (20 ng for visual discrimination between this standard and the zero). The assay is stable to the effects of ambient air sampling at 31 min(-1) for 18 h.  相似文献   

14.
Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent from the filter surface. In this paper, this drawback has been overcome by changing the filter material to the less polar polystyrene divinyl benzene (SDB). A series of experiments was performed to compare the analyte uptake on the two filter materials for different sampling periods and analyte concentrations at both low and high RH conditions. Additionally, the materials were investigated as well for passive sampling of ethyl (EIC) and phenyl isocyanate (PhIC) with NBDPZ and 1-(2-methoxyphenyl) piperazine (2-MP) as an alternative derivatising agent. Using 2-MP, the mean GF/SDB response ratios were determined to be 1.02 for MIC (RSD: 6.1%) and 1.03 for EIC (RSD: 6.8%), whereas PhIC could only be determined on SDB filters. Using NBDPZ as reagent, the negative influence of high humidity disappeared when SDB filters were used instead of GF filters. Even at low RH conditions, sampling with SDB material generally resulted in a higher analyte uptake than with GF filters. The GF/SDB response ratios were independent of sampling time or analyte concentration and were determined to be 0.70 (RSD: 4.7%) for MIC, 0.84 (RSD: 4.5%) for EIC and 0.95 (RSD 5.4%) for PhIC, meaning that the NBDPZ diffusive sampler based on SDB can be used at all humidity conditions without any restrictions.  相似文献   

15.
A method is presented for the determination of isocyanic acid (ICA), HNCO, in air samples as a di-n-butylamine (DBA) derivative. The method is based on sampling in midget impinger flasks containing 10 ml of 0.01 mol l-1 DBA in toluene. Quantification was made using liquid chromatography (LC) and electrospray mass spectrometry (MS) monitoring positive ions. The instrumental detection limit for the LC-MS was 10 fmol of ICA-DBA. ICA was generated by thermal decomposition of urea. A standard solution containing the DBA derivatives of ICA was prepared by collecting the emitted ICA in an impinger flask containing DBA. ICA in the reference solution was characterised by LC and time-of-flight (TOF) MS and quantified by LC chemiluminescent nitrogen detection (LC-CLND). The instrumental detection limit for the LC-CLND was 1 ng of nitrogen. ICA was emitted during thermal degradation of PFU resins and polyurethane (PUR) lacquers, from car metal sheets. ICA was the most dominant isocyanate and in PUR coating up to 8% of the total weight was emitted as ICA and for PFU resins up to 14% was emitted as ICA. When air samples were collected in an iron foundry during casting in sand moulds with furan resins, concentrations of ICA in the range 50-700 micrograms m-3 were found in the working atmosphere.  相似文献   

16.
A sensitive spectrofluorimetric-FIA (flow injection analysis) method for formaldehyde (HCHO) determination was improved with the aim of analysing seawater samples.The fluorescence emission versus HCHO concentration shows a linear pattern from sub microg L(-1) to about 1000 microg L(-1). The reproducibility at 15 ppb level is about 2%. Interferences from other aldehydes were checked; only glyoxal shows a significative interference, but only when its concentration is about 6000 times higher than that of formaldehyde. Superficial (microlayer, just sub-pack or sea-ice free sea surface) and deep (along the water column, sub-pack or in sea-ice free areas) seawater samples were collected near the coast at Terra Nova Bay (Ross Sea, Antarctica) during the 1998/1999 and 2001/2002 Italian Antarctic Expedition. We report here the preliminary results of the spectrofluorimetric-FIA determination of the HCHO content. The mean seawater superficial formaldehyde concentration was 15 microg L(-1); the concentration along the water column ranged between 4.5 to over 40 microg L(-1)(20 microg L(-1) mean concentration), usually with a maximum value for the 30 m depth, corresponding to a fluorescence maximum. The sampling was repeated 7 times in the austral summer in order to evaluate seasonal changes in the formaldehyde concentration/seawater depth profiles. The results show changes in the formaldehyde concentration at different depths.  相似文献   

17.
Accurate measurement of bacterial and viral abundance in coastal marine environments is important to understand the dynamics of microbial communities in these ecosystems. In this study, the effect of formaldehyde preservation on the abundance of bacteria and viruses in water samples from Cochin Backwater was determined by SYBR Green I staining and epifluorescence microscopy. The counts were determined for 45 days in samples fixed with 1?C6% formaldehyde. The results suggest rapid decline in counts of bacteria and viruses in samples preserved in formaldehyde, and the decline increased with increase in the final concentration of formaldehyde in the sample. The initial bacterial and viral counts in the sampling site were 5.2 × 106/ml and 3.9 × 107/ml, respectively. The bacterial count dropped by 5.1%, 53.3%, 55.7%, and 85% after 1, 7, 15, and 45 days, respectively, in sample fixed with 1% formaldehyde. The decline in viral counts was higher, being 32.4%, 47.9%, 68.1%, and 93% after 1, 7, 15, and 45 days, respectively. Storage of fixed samples at ??20°C did not halt the decline in microbial counts, suggesting that, irrespective of storage temperature, formaldehyde-fixed samples lead to underestimation of microbial counts.  相似文献   

18.
采用固体进样原子吸收法直接测定土壤中的镉,可以避免传统酸消解预处理过程耗时长、试剂消耗大、操作步骤繁琐等缺点,提升镉的检测效率。通过优化测镉仪的仪器参数,确定了固体进样-电热蒸发-原子吸收法的优化仪器条件。采用优化条件测定了不同浓度的土壤样品,研究了该方法的检出限、正确度、精密度。研究结果表明:镉质量范围为0~200 ng时与峰面积的线性相关系数优于0.999 5,空气流下优化的灰化温度和热解温度均为800 ℃,优化的热解气体氢气流量为300 mL/min,当样品进样量为0.1 g时,检出限为0.009 mg/kg,7次连续测定相对标准偏差为1.4%~5.0%,加标回收率为96.2%~102.1%,分析时间小于4 min。该方法操作简便,用时短,无需高压气源,可以用于土壤中镉的高效检测。  相似文献   

19.
An air sampling method for simultaneous determination of organic acid anhydrides and isocyanates is presented. Air samples are collected in impinger flasks filled with 0.01 M di-n-butylamine (DBA) in a mixture of toluene-acetonitrile (7:3, v/v) with a 13 millimetre glass fibre filter in series. The amount of anhydrides and isocyanates are determined as their amide and urea derivatives using LC-MS. Four anhydrides, maleic anhydride (MA), phthalic anhydride (PA), tetrahydrophthalic anhydride (TA) and cis-hexahydrophthalic anhydride (HA) and 11 isocyanates could be separated in 9 minutes using gradient elution. Anhydride-DBA derivatives in standard solutions were quantified using LC with chemiluminescent nitrogen detection (CLND). Anhydride-DBA derivatives were found to be stable for at least two months when stored in acetonitrile or toluene in the freezer. The yield of DBA derivatives of anhydrides in the 0.01 M DBA in toluene-acetonitrile (7:3, v/v) was in the range of 70->95%. Using MS and negative electrospray ionisation (ES-) linear calibrations curves were obtained for the anhydrides with correlation coefficients ranging from 0.9970-0.9997. The instrumental detection limit for the anhydrides ranged from 10-30 fmol, based on a signal to noise root mean square (RMS) ratio of 3. Monitoring positive and negative ions simultaneously, both isocyanates and anhydrides could be determined as their DBA derivatives in the same chromatographic run. When air samples were collected during thermal degradation of different coated metal sheets both anhydrides and isocyanates were present in the same samples and all the studied anhydrides were found.  相似文献   

20.
根据PM2.5中重金属监测国标分析方法,从PM2.5采样方法、采样保存条件、滤膜材质性能等方面说明利用空气自动采样滤膜监测PM2.5中铅和镉是可行的;对手工采样(石英滤膜)和Beta射线法自动采样(自动采样滤膜)2种方法,对PM2.5实际样品中铅和镉的结果进行比较,结果显示:自动采样滤膜的空白检出和检出限均满足铅和镉的监测需求,铅和镉的回收率分别为95.2%~107%和91.8%~105%,与手工采样方法相比测得铅和镉的相对误差分别为3.6%~8.4%和1.3%~10.8%,从实践角度进一步证明了利用自动采样滤膜对PM2.5中铅和镉进行监测是可行的。  相似文献   